Search NASA⌕ Search

SEARCH · Search NASA

Results for “Smoothing methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Analysis of Dust Samples Collected from an In-Service Interim Storage System at the Maine Yankee Nuclear Site.

In July, 2016, the Electric Power Research Institute and industry partners performed a field test at the Maine Yankee Nuclear Site, located near Wiscasset, Maine. The primary goal of the field test was to evaluate the use of robots in surveying the surface of an in-service interim storage canister within an overpack; however, as part of the demonstration, dust and soluble salt samples were collected from horizontal surfaces within the interim storage system. The storage system is a vertical system made by NAC International, consisting of a steel-lined concrete overpack containing a 304 stainless steel (SS) welded storage canister. The canister did not contain spent fuel but rather greater-than-class-C waste, which did not generate significant heat, limiting airflow through the storage system. The surfaces that were sampled for deposits included the top of the shield plug, the side of the canister, and a shelf at the bottom of the overpack, just below the level of the pillar on which the canister sits. The samples were sent to Sandia National Laboratories for analysis. This report summarizes the results of those analyses. Because the primary goal of the field test was to evaluate the use of robots in surveying the surface of the canister within the overpack, collection of dust samples was carried out in a qualitative fashion, using paper filters and sponges as the sampling media. The sampling focused mostly on determining the composition of soluble salts present in the dust. It was anticipated that a wet substrate would more effectively extract soluble salts from the surface that was sampled, so both the sponges and the filter paper were wetted prior to being applied to the surface of the metal. Sampling was accomplished by simply pressing the damp substrate against the metal surface for two minutes, and then removing it. It is unlikely that the sampling method quantitatively collected dust or salts from the metal surface; however, both substrates did extract a significant amount of material. The paper filters collected both particles, trapped within the cellulose fibers of the filter, and salts, while the sponges collected only the soluble salts, with very few particles. Upon delivery to Sandia, both collection media were analyzed using the same methods. The soluble salts were leached from the substrates and analyzed via ion chromatography, and insoluble minerals were analyzed by scanning electron microscopy and energy dispersive X-ray spectroscopy. The insoluble minerals were found to consist largely of terrestrially-derived mineral fragments, dominantly quartz and biotite. Large (mm-sized) aggregates of calcium carbonate, calcium silicate, and calcium aluminum silicate were also present. The aggregates had one flat, smooth surface and one well crystallized surface, and were interpreted to be efflorescence on the inside of the overpack and in the vent, formed by seepage of cement pore fluids through joints in the steel liner of the overpack. Such efflorescence was commonly observed during the boroscope inspection of the storage system at the site. The material may have flaked off and fallen to the point where the dust was collected, or may have brushed off onto the sponges when the robot was retrieved through the inlet vent. Chemical analysis showed that the soluble salts on the shield plug were Ca- and Na-rich, with lesser K and minor Mg; the anionic component was dominated by SO 4 and Cl, with minor amounts of NO 3 . The cation composition of the soluble salts from the overpack shelf and the canister surface was similar to the filter samples, but the anions differed significantly, being dominantly NO 3 with lesser Cl and only trace SO 4 . The salts appear to represent a mixture of sea-salts (probably partially converted to nitrates and sulfates by particle-gas conversion reactions) and continental salt aerosols. Ammonium, a common component in continental aerosols, was not observed and may have been lost by degassing from the canister surface or after collection during sample storage and transportation. The demonstration at Maine Yankee has shown that the robot and sampling method used for the test can successfully be used to collect soluble salts from metal surfaces within an interim storage system overpack. The results were consistent from sample to sample, suggesting that a representative sample of the soluble salts was being collected. However, it is unlikely that the salt samples collected here represent quantitative sampling of the salts on the surfaces evaluated; for that reason, chloride densities per unit area are not presented here. It should also be noted that the relevance to storage systems at the site that contain SNF may be limited, because a heat- generating canister will result in greater airflow through the overpack, affecting dust deposition rates and possibly salt compositions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison between Lagrangian and mesoscopic Eulerian modelling approaches for inertial particles suspended in decaying isotropic turbulence

The purpose of this paper is to evaluate the accuracy of the mesoscopic approach proposed by Fevrier et al. [P. Fevrier, O. Simonin, K.D. Squires, Partitioning of particle velocities in gas-solid turbulent flows into a continuous field and a spatially uncorrelated random distribution: theoretical formalism and numerical study, J. Fluid Mech. 533 (2005) 1-46] by comparison against the Lagrangian approach for the simulation of an ensemble of non-colliding particles suspended in a decaying homogeneous isotropic turbulence given by DNS. The mesoscopic Eulerian approach involves to solve equations for a few particle PDF moments: number density, mesoscopic velocity, and random uncorrelated kinetic energy (RUE), derived from particle flow ensemble averaging conditioned by the turbulent fluid flow realization. In addition, viscosity and diffusivity closure assumptions are used to compute the unknown higher order moments which represent the mesoscopic velocity and RUE transport by the uncorrelated velocity component. A detailed comparison between the two approaches is carried out for two different values of the Stokes number based on the initial fluid Kolmogorov time scale, St{sub K}=0.17and2.2. In order to perform reliable comparisons for the RUE local instantaneous distribution and for the mesoscopic kinetic energy spectrum, the error due to the computation method of mesoscopic quantities from Lagrangian simulation results is evaluated and minimized. A very good agreement is found between the mesoscopic Eulerian and Lagrangian predictions for the small particle Stokes number case corresponding to the smallest particle inertia. For larger particle inertia, a bulk viscous term is included in the mesoscopic velocity governing equation to avoid spurious spatial oscillation that may arise due to the inability of the numerical scheme to resolve sharp number density gradients. As a consequence, for St{sub K}=2.2, particle number density and RUE spatial distribution predicted by the mesoscopic Eulerian approach are more smooth with respect to the ones measured from the Lagrangian simulations results. Similarly, the Eulerian approach underestimates the mesoscopic kinetic energy for the high wavenumber modes while the agreement remains very good for the low wavenumber modes. For both cases, the mesoscopic Eulerian approach provides a good prediction of the time dependent particle and fluid-particle velocity correlations measured by spatial averaging in the whole computational domain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Towards a unified nonlocal, peridynamics framework for the coarse-graining of molecular dynamics data with fractures

Molecular dynamics (MD) has served as a powerful tool for designing materials with reduced reliance on laboratory testing. However, the use of MD directly to treat the deformation and failure of materials at the mesoscale is still largely beyond reach. In this work, we propose a learning framework to extract a peridynamics model as a mesoscale continuum surrogate from MD simulated material fracture data sets. Firstly, we develop a novel coarse-graining method, to automatically handle the material fracture and its corresponding discontinuities in the MD displacement data sets. Inspired by the weighted essentially non-oscillatory (WENO) scheme, the key idea lies at an adaptive procedure to automatically choose the locally smoothest stencil, then reconstruct the coarse-grained material displacement field as the piecewise smooth solutions containing discontinuities. Then, based on the coarse-grained MD data, a two-phase optimization-based learning approach is proposed to infer the optimal peridynamics model with damage criterion. In the first phase, we identify the optimal nonlocal kernel function from the data sets without material damage to capture the material stiffness properties. Then, in the second phase, the material damage criterion is learnt as a smoothed step function from the data with fractures. As a result, a peridynamics surrogate is obtained. As a continuum model, our peridynamics surrogate model can be employed in further prediction tasks with different grid resolutions from training, and hence allows for substantial reductions in computational cost compared with MD. We illustrate the efficacy of the proposed approach with several numerical tests for the dynamic crack propagation problem in a single-layer graphene. Our tests show that the proposed data-driven model is robust and generalizable, in the sense that it is capable of modeling the initialization and growth of fractures under discretization and loading settings that are different from the ones used during training.

97 MATHEMATICS AND COMPUTING↗

Effect of helical micro-fins on two-phase flow behavior of R410A evaporating in horizontal round tubes obtained through visualization

This paper presents a new approach in visualization of the evaporation mechanism and the two phase flow. The visualization test section is a transparent micro-fin tube made by 3D printing. The 3D printing technology helps reproduce the real geometry in commercial metal micro-fin tubes. Even though the wall material is different from the real metal, this new method provides a more complete understanding of the mechanisms of flow boiling and the heat transfer enhancement due to micro-fin geometry. To investigate the effect of micro-fin geometries on two-phase flow behavior, R410A flow boiling experiments are conducted at 1°C saturation temperature and visualized through a clear smooth tube and micro-fin tubes of 0°, 10° and 18° helix angles. The results showed that the annular flow pattern in the helical micro-fin tube occurred at a lower vapor quality than the smooth and axial micro-fin tubes. Helix angle affects the transition boundary of stratified wavy flow to wavy annular flow, which shifts downward (to lower mass flux and vapor quality conditions) as the helix angle increases. Other transitions are not significantly affected by the helix angle. Helical micro-fin tubes with different groove directions were made to understand the flow behavior on the upward side and downward side of the tube.

3D printing↗

Tile-and-trim micro-resonator array fabrication optimized for high multiplexing factors

We present a superconducting micro-resonator array fabrication method that is scalable and reconfigurable and has been optimized for high multiplexing factors. The method uses uniformly sized tiles patterned on stepper photolithography reticles as the building blocks of an array. We exhibit this technique on a 101-element microwave kinetic inductance detector (MKID) array made from a titanium-nitride superconducting film. Characterization reveals 1.5% maximum fractional frequency spacing deviations caused primarily by material parameters that vary smoothly across the wafer. Yet, local deviations demonstrate a Gaussian distribution in fractional frequency spacing with a standard deviation of 2.7 × 10 -3 . We exploit this finding to increase the yield of the BLAST-TNG 250 μm production wafer by placing resonators in the array close in both physical and frequency space. This array consists of 1836 polarization-sensitive MKIDs wired in three multiplexing groups. We present the array design and show that the achieved yield is consistent with our model of frequency collisions and is comparable to what has been achieved in other low temperature detector technologies.

36 MATERIALS SCIENCE↗

Quantitative estimates in Beurling-Helson type theorems

We consider the spaces A{sub p}(T) of functions f on the circle T such that the sequence of Fourier coefficients f-hat={l_brace}f-hat(k), k element of Z{r_brace} belongs to l{sup p}, 1{<=}p<2. The norm in A{sub p}(T) is defined by ||f||{sub A{sub p}}=||f-hat||{sub l}{sup P}. We study the rate of growth of the norms ||e{sup i{lambda}{phi}|}|{sub A{sub p}} as |{lambda}|{yields}{infinity}, {lambda} element of R, for C{sup 1}-smooth real functions {phi} on T. The results have natural applications to the problem of changes of variable in the spaces A{sub p}(T). Bibliography: 17 titles.

97 MATHEMATICS AND COMPUTING↗

FOLD LENS FLUX ANOMALIES: A GEOMETRIC APPROACH

We develop a new approach for studying flux anomalies in quadruply imaged fold lens systems. We show that in the absence of substructure, microlensing, or differential absorption, the expected flux ratios of a fold pair can be tightly constrained using only geometric arguments. We apply this technique to 11 known quadruple lens systems in the radio and infrared and compare our estimates to the Monte Carlo based results of Keeton et al. We show that a robust estimate for a flux ratio from a smoothly varying potential can be found, and at long wavelengths those lenses deviating from this ratio almost certainly contain significant substructure.

79 ASTRONOMY AND ASTROPHYSICS↗

Calculation of the shear viscosity in SU(3) gluodynamics

We perform a lattice Monte Carlo calculation of the two-point functions of the energy-momentum tensor at finite temperature in the SU(3) gauge theory. Unprecedented precision is obtained thanks to a multilevel algorithm. The lattice operators are renormalized nonperturbatively and the classical discretization errors affecting the correlators are corrected for. A conservative upper bound for the shear viscosity to entropy density ratio is derived, {eta}/s<1.0, and our best estimate is {eta}/s=0.134(33) at T=1.65T{sub c} under the assumption of smoothness of the spectral function in the low-frequency region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Polymer thin films as universal substrates for extreme ultraviolet absorption spectroscopy of molecular transition metal complexes

Polystyrene and polyvinyl chloride thin films are explored as sample supports for extreme ultraviolet (XUV) spectroscopy of molecular transition metal complexes. Thin polymer films prepared by slip-coating are flat and smooth, and transmit much more XUV light than silicon nitride windows. Analytes can be directly cast onto the polymer surface or co-deposited within it. The M-edge XANES spectra (40–90 eV) of eight archetypal transition metal complexes (M = Mn, Fe, Co, Ni) are presented to demonstrate the versatility of this method. The films are suitable for pump/probe transient absorption spectroscopy, as shown by the excited-state spectra of Fe(bpy) 3 2+ in two different polymer supports.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of thermodynamic fluctuations and pattern size on the nucleation behavior during area selective deposition

In this work, the authors explore the impact that thermodynamic fluctuations have on the spontaneous appearance of defects during area selective deposition on patterned surfaces that are fully covered by adsorbates under local thermodynamic equilibrium, such as self-assembled monolayers. By using a simple lattice gas model for the adsorbed monolayer, the authors were able to track the spontaneous formation of defects in the monolayer as a function of the pattern width. The results indicate that, for pattern widths of the order of tens of nanometers, roughening effects at the pattern edge can be the leading source for the spontaneous appearance of nucleation defects. This leads to an enhancement of the density of defects that can be up to three orders of magnitude higher than those expected in uniform (not patterned) surfaces. The model also predicts a density of defects that is inversely proportional to the pattern width. Finally, if the dynamic nucleation of defects during area selective deposition is driven by thermodynamic fluctuations, the model predicts that the nucleation rate should be proportional to the total precursor fluency and independent of purge times. Moreover, a tight confinement of the monolayer through a high quality smooth interface in the patterned substrate and strong cohesive interactions between adsorbates should each contribute to a reduction of the overall defect density.

36 MATERIALS SCIENCE↗

TU-F-CAMPUS-I-04: A Novel Phantom to Evaluate Longitudinal and Angular Automatic Tube Current Modulation (ATCM) in CT

Purpose: To manufacture a phantom specifically designed for the purpose of evaluating the performance of the longitudinal and angular automatic tube current modulation (ATCM) on modern CT scanners. Methods: In order to evaluate angular ATCM, the phantom has an elliptical cross section (aspect ratio 3:2). To evaluate longitudinal ATCM, the phantom consists of 3 sections, with different major axes (25 cm, 30 cm and 35 cm). Each section is 15 cm long in the longitudinal direction. Between each section is a smooth transition. The phantom was milled from a solid block of PMMA. ATCM performance is evaluated by 1) analyzing the applied tube current for each slice of the phantom and 2) analyzing the distribution of image noise (σ) along the scan direction at different positions in the phantom. A demonstration of the ATCM performance evaluation is given by investigating the effects of miscentering during a CT scan. Results: The developed phantom has proven useful for evaluating both the longitudinal and angular ATCM on modern CT scanners (spiral collimations ≥ 4 cm). Further benefits are the smooth transitions between the sections that prevent abnormal responses in the ATCM and the invariant sections that provide a means for investigating the stability of image noise. The homogeneity of the phantom makes image noise at different positions along the scan direction easy to quantify, which is crucial to understand how well the applied ATCM can produce a desired image quality. Conclusion: It is important to understand how the ATCM functions on CT scanners as it can directly affect dose and image quality. The phantom that has been developed is a most valuable tool to understand how different variables during a scan can affect the outcome of the longitudinal and angular ATCM.

60 APPLIED LIFE SCIENCES↗

On a Technique of Studying the Interface Kinetics and Anisotropy of Specific Interfacial Energy Based on Experiments on Migration of Liquid Cylindrical Inclusions in a Crystal under Stationary Thermal Conditions

A method for processing experimental data on the migration of liquid cylindrical inclusions in a crystal under a temperature gradient has been considered on the assumption that the experimental thermal conditions are stationary. Formulas are derived to calculate the degree of interfacial energy anisotropy and relative hindrance of the crystallization and dissolution processes at atomically smooth interface areas based on the shapes of cross sections of cylindrical inclusions migrated perpendicular to the close-packed crystal planes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms. Point spread function (PSF) correction and TOF reconstruction in general reduce background variability and noise and increase recovered concentration. Results for patient data indicated a good correlation between the expected and PET reconstructed activities. A linear relationship between the expected and the measured activities in the organ of interest was observed for all reconstruction method used: a linearity coefficient of 0.89 ± 0.05 for the Biograph mCT and 0.81 ± 0.05 for the Biograph TruePoint. Conclusions: Due to the low counts and high random fraction, accurate image quantification of {sup 90}Y during selective internal radionuclide therapy is affected by random coincidence estimation, scatter correction, and any positivity constraint of the algorithm. Nevertheless, phantom and patient studies showed that the impact of number of true and random coincidences on quantitative results was found to be limited as long as ordinary Poisson ordered subsets expectation maximization reconstruction algorithms with random smoothing are used. Adding PSF correction and TOF information to the reconstruction greatly improves the image quality in terms of bias, variability, noise reduction, and detectability. On the patient studies, the total activity in the field of view is in general accurately measured by Biograph mCT and slightly overestimated by the Biograph TruePoint.

60 APPLIED LIFE SCIENCES↗

Noise-resolution tradeoffs in x-ray CT imaging: A comparison of penalized alternating minimization and filtered backprojection algorithms

Purpose: In comparison with conventional filtered backprojection (FBP) algorithms for x-ray computed tomography (CT) image reconstruction, statistical algorithms directly incorporate the random nature of the data and do not assume CT data are linear, noiseless functions of the attenuation line integral. Thus, it has been hypothesized that statistical image reconstruction may support a more favorable tradeoff than FBP between image noise and spatial resolution in dose-limited applications. The purpose of this study is to evaluate the noise-resolution tradeoff for the alternating minimization (AM) algorithm regularized using a nonquadratic penalty function. Methods: Idealized monoenergetic CT projection data with Poisson noise were simulated for two phantoms with inserts of varying contrast (7%-238%) and distance from the field-of-view (FOV) center (2-6.5 cm). Images were reconstructed for the simulated projection data by the FBP algorithm and two penalty function parameter values of the penalized AM algorithm. Each algorithm was run with a range of smoothing strengths to allow quantification of the noise-resolution tradeoff curve. Image noise is quantified as the standard deviation in the water background around each contrast insert. Modulation transfer functions (MTFs) were calculated from six-parameter model fits to oversampled edge-spread functions defined by the circular contrast-insert edges as a metric of local resolution. The integral of the MTF up to 0.5 lp/mm was adopted as a single-parameter measure of local spatial resolution. Results: The penalized AM algorithm noise-resolution tradeoff curve was always more favorable than that of the FBP algorithm. While resolution and noise are found to vary as a function of distance from the FOV center differently for the two algorithms, the ratio of noises when matching the resolution metric is relatively uniform over the image. The ratio of AM-to-FBP image variances, a predictor of dose-reduction potential, was strongly dependent on the shape of the AM's nonquadratic penalty function and was also strongly influenced by the contrast of the insert for which resolution is quantified. Dose-reduction potential, reported here as the fraction (%) of FBP dose necessary for AM to reconstruct an image with comparable noise and resolution, for one penalty parameter value of the AM algorithm was found to vary from 70% to 50% for low-contrast and high-contrast structures, respectively, and from 70% to 10% for the second AM penalty parameter value. However, the second penalty, AM-700, was found to suffer from poor low-contrast resolution when matching the high-contrast resolution metric with FBP. Conclusions: The results of this simulation study imply that penalized AM has the potential to reconstruct images with similar noise and resolution using a fraction (10%-70%) of the FBP dose. However, this dose-reduction potential depends strongly on the AM penalty parameter and the contrast magnitude of the structures of interest. In addition, the authors' results imply that the advantage of AM can be maximized by optimizing the nonquadratic penalty function to the specific imaging task of interest. Future work will extend the methods used here to quantify noise and resolution in images reconstructed from real CT data.

60 APPLIED LIFE SCIENCES↗

Flow and Arching of Biomass Particles in Wedge-Shaped Hoppers

Poor understanding of the flow behavior of granular biomass material poses great challenges for the bioenergy industry, as the equipment functioning time is significantly reduced by handling issues like screw feeder clogging and hopper arching. In this work, the flow behavior of loblolly pine chips, including the mass flow rate and the critical outlet width, in a wedge-shaped hopper is investigated by combining physical experiments and numerical simulations. Comprehensive characterization of the flow response affected by the two material attributes (initial packing, particle density) and the three operational parameters (hopper outlet width, hopper inclination, and surcharge) is conducted. The results show that the hopper outlet width linearly controls the mass flow rate while the hopper inclination angle controls the critical outlet size. The packing determines whether the flow is smooth or surging, and the surcharge-induced compaction creates flow impedance. The magnitude of these influences varies from a slender hopper with a low inclination angle to a flat-bottom silo. These findings provide guidance for hopper operation in the material handling industry and shed light on the construction of a novel design method for material handling equipment in biorefineries.

09 BIOMASS FUELS↗

A surface work function measurement technique utilizing constant deflected grazing electron trajectories: Oxygen uptake on Cu(001)

We report on the application of a novel nondestructive in-vacuum technique for relative work function measurements, employing a grazing incidence electron deflection above a sample with a planar surface. Two deflected electron beam detectors are used as a position sensitive detector to control feedback to the sample potential as the sample work function changes. With feedback the sample potential exactly follows the surface sample-size averaged work function variation, so that the deflected beam trajectory remains stable. We also discuss methods to optimize the initial electron trajectories for this method, so as to minimize unwanted effects such as from uncontrolled external magnetic fields. As the electron beam does not impinge on the surface in this new technique electron induced desorption, ionization, dissociation, and/or decomposition is not induced at the interface. Importantly also the technique allows for free access to the surfaces enabling simultaneous deposition/evaporation and/or application of other surface characterization methods. We demonstrate its application in concurrent measurements of helium atom reflectivity and work function changes taking place during molecular oxygen exposure of a Cu(001) surface. A work function measurement sensitivity and stability is demonstrated at {approx}10 mV at a sampling rate of 1 Hz and after application of an {approx}7 s smoothing routine. In comparison to the helium atom reflectivity measurements, the work function measurements are more sensitive to the initial O uptake, and less so to the final coverage variations and possible surface reordering at higher O coverages.

43 PARTICLE ACCELERATORS↗

AN ALTERNATIVE APPROACH TO MEASURING REVERBERATION LAGS IN ACTIVE GALACTIC NUCLEI

Motivated by recent progress in the statistical modeling of quasar variability, we develop a new approach to measuring emission-line reverberation lags to estimate the size of broad-line regions (BLRs) in active galactic nuclei. Assuming that all emission-line light curves are scaled, smoothed, and displaced versions of the continuum, this alternative approach fits the light curves directly using a damped random walk model and aligns them to recover the time lag and its statistical confidence limits. We introduce the mathematical formalism of this approach and demonstrate its ability to cope with some of the problems for traditional methods, such as irregular sampling, correlated errors, and seasonal gaps. We redetermine the lags for 87 emission lines in 31 quasars and reassess the BLR size-luminosity relationship using 60 H{beta} lags. We confirm the general results from the traditional cross-correlation methods, with a few exceptions. Our method, however, also supports a broad range of extensions. In particular, it can simultaneously fit multiple lines and continuum light curves which improves the lag estimate for the lines and provides estimates of the error correlations between them. Determining these correlations is of particular importance for interpreting emission-line velocity-delay maps. We can also include parameters for luminosity-dependent lags or line responses. We use this to detect the scaling of the BLR size with continuum luminosity in NGC 5548.

79 ASTRONOMY AND ASTROPHYSICS↗

A COMPARATIVE STUDY OF DENSITY FIELD ESTIMATION FOR GALAXIES: NEW INSIGHTS INTO THE EVOLUTION OF GALAXIES WITH ENVIRONMENT IN COSMOS OUT TO z ∼ 3

It is well-known that a galaxy’s environment has a fundamental influence in shaping its properties. We study the environmental effects on galaxy evolution, with an emphasis on the environment defined as the local number density of galaxies. The density field is estimated with different estimators (weighted adaptive kernel smoothing, 10th and 5th nearest neighbors, Voronoi and Delaunay tessellation) for a K{sub s} < 24 sample of ∼190,000 galaxies in the COSMOS field at 0.1 < z < 3.1. The performance of each estimator is evaluated with extensive simulations. We show that overall there is a good agreement between the estimated density fields using different methods over ∼2 dex in overdensity values. However, our simulations show that adaptive kernel and Voronoi tessellation outperform other methods. Using the Voronoi tessellation method, we assign surface densities to a mass complete sample of quiescent and star-forming galaxies out to z ∼ 3. We show that at a fixed stellar mass, the median color of quiescent galaxies does not depend on their host environment out to z ∼ 3. We find that the number and stellar mass density of massive (>10{sup 11} M{sub ⊙}) star-forming galaxies have not significantly changed since z ∼ 3, regardless of their environment. However, for massive quiescent systems at lower redshifts (z ≲ 1.3), we find a significant evolution in the number and stellar mass densities in denser environments compared to lower density regions. Our results suggest that the relation between stellar mass and local density is more fundamental than the color–density relation and that environment plays a significant role in quenching star-formation activity in galaxies at z ≲ 1.

79 ASTRONOMY AND ASTROPHYSICS↗