Potential of module arrangements to enhance convective cooling in solar photovoltaic arrays
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Regulating the temperature of building integrated photovoltaics (BIPV) using phase change materials (PCMs) reduces the loss of temperature dependent photovoltaic (PV) efficiency. Five PCMs were selected for evaluation all with melting temperatures {proportional_to}25 {+-} 4 C and heat of fusion between 140 and 213 kJ/kg. Experiments were conducted at three insolation intensities to evaluate the performance of each PCM in four different PV/PCM systems. The effect on thermal regulation of PV was determined by changing the (i) mass of PCM and (ii) thermal conductivities of the PCM and PV/PCM system. A maximum temperature reduction of 18 C was achieved for 30 min while 10 C temperature reduction was maintained for 5 h at -1000 W/m{sup 2} insolation. (author)
We investigate the problem of characterizing the economic value of energy storage capacity to a wind power producer (WPP) that sells its energy in a conventional two-settlement electricity market. The WPP can offer a forward contract to supply power in the day-ahead market, subject to financial penalties for imbalances between the contracted power and the power that is delivered in real-time. We consider the setting in which the WPP has access to a co-located energy storage system, and can thus reshape its wind power production subject to its storage capacity constraints. Modeling wind power as a random process, we show that the problem of determining optimal forward contract offerings—given recourse with storage—is convex. We further establish that the maximum expected profit is concave and non-decreasing in the energy storage capacity, which reveals that the greatest marginal benefit from energy storage is derived from initial investment in small storage capacity. We provide a characterization of the marginal value of small energy storage capacity to the WPP. The formulae we derive shed light on the relationship between the value of storage and certain statistical measures of variability in the underlying wind power process.
We present a study on the electrochemical behavior of magnesium hydroxide (MgOH + ) reduction on a tungsten (W) cathode in molten chloride salt (MgCl 2 -KCl-NaCl) across the temperature range of 475 °C–525 °C. MgOH + , which forms within the salt upon exposure to moisture, is a leading cause of corrosion. Corrosion is a major barrier to deployment of chloride salts across a number of applications, including concentrating solar power plants and nuclear power plants. While pre-purification protocols have been developed to ensure MgOH + is removed from molten chloride salts prior to deployment, MgOH + forms in situ during operation of chloride-salt based plants. Thus, methods for continuous purification during plant operation are needed. Continuous electrochemical purification via electrolysis using a Mg anode and W cathode has been proposed, but little has been done to assess scalability. Here, we assess fundamental properties of electrochemical removal of MgOH + to enable future scale up of this method.
FRAMES is a a set of Excel metadata files and package-level descriptive metadata that are designed to facilitate and improve capture of desired metadata for ecohydrological observations. The metadata are bundled with data files into a data package and submitted to a data repository (e.g. the NGEE Tropics Data Repository) via a web form. FRAMES standardizes reporting of diverse ecohydrological and biogeochemical data for synthesis across a range of spatiotemporal scales and incorporates many best data science practices. This version of FRAMES supports observations for primarily automated measurements collected by permanently located sensors, including sap flow (tree water use), leaf surface temperature, soil water content, dendrometry (stem diameter growth increment), and solar radiation. Version 1.1 extend the controlled vocabulary and incorporates functionality to facilitate programmatic use of data and FRAMES metadata (R code available at NGEE Tropics Data Repository).
Arizona Public Service Company (APS) expects that by 2027, renewable energy will account for 6,590 GWh in energy consumption by its customers. While much of this future energy will come from large centrally-located power plants, distributed renewable energy, sited at the point of end-use will also play an important role in meeting the needs of APS customers and is expected to provide 1,734 GWh.
To help the United States develop a modern electricity grid that provides reliable power from multiple resources as well as resiliency under extreme conditions, the U.S. Department of Energy (DOE) is leading the Grid Modernization Initiative (GMI) to help shape the future of the nation's grid. Under the GMI, DOE funded the Vermont Regional Initiative project to provide the technical support and analysis to utilities that need to mitigate possible impacts of increasing renewable generation required by statewide goals. Advanced control of distributed energy resources (DER) can both support higher penetrations of renewable energy by balancing controllable loads to wind and photovoltaic (PV) solar generation and reduce peak demand by shedding noncritical loads. This work focuses on the latter. This document reports on an experiment that evaluated and quantified the potential benefits and impacts of reducing the peak load through demand response (DR) using centrally controllable electric water heaters (EWHs) and batteries on two Green Mountain Power (GMP) feeders. The experiment simulated various hypothetical scenarios that varied the number of controllable EWHs, the amount of distributed PV systems, and the number of distributed residential batteries. The control schemes were designed with several objectives. For the first objective, the primary simulations focused on reducing the load during the independent system operator (ISO) peak when capacity charges were the primary concern. The second objective was to mitigate DR rebound to avoid new peak loads and high ramp rates. The final objective was to minimize customers' discomfort, which is defined by the lack of hot water when it is needed. We performed the simulations using the National Renewable Energy Laboratory's (NREL's) Integrated Energy System Model (IESM) because it can simulate both electric power distribution feeder and appliance end use performance and it includes the ability to simulate multiple control strategies.
Interconnect, solder, and metallization-related failures are the primary reason for premature Si-based photovoltaic panel failure [1, 2] and can lead to a cascade of other failures, including thermal events. This combination of high severity and high occurrence means that understanding interconnect-related failures is key to the long-term health of the photovoltaic industry, and it is crucial that the industry adopt efficient and effective tests that aid in design-for-reliability and manufacturing quality control.
Effect of solar ultraviolet radiation on spacecraft thermal control surfaces with low absorptance/emittance ratio
Digital computer simulation of solar pressure effect on spacecraft attitude control after gas system depletion
Spacecraft attitude sensor types, principles and future development
Soldering or epoxy bonding of cadmium sulfide thin film solar cells into modules and quality control testing
Attachment methods for thermal control composite system comprised of optical solar reflectors and multilayer insulation to minimize heating from incident solar energy
Design and characteristics of device for sensing solar radiation and providing spacecraft attitude control to maintain direction with respect to incident radiation
Radiation was found not to be an operational problem during the Apollo program. Doses received by the crewmen of Apollo missions 7 through 17 were small because no major solar-particle events occurred during those missions. One small event was detected by a radiation sensor outside the Apollo 12 spacecraft, but no increase in radiation dose to the crewmen inside the spacecraft was detected. Radiation protection for the Apollo program was focused on both the peculiarities of the natural space radiation environment and the increased prevalence of manmade radiation sources on the ground and onboard the spacecraft. Radiation-exposure risks to crewmen were assessed and balanced against mission gain to determine mission constraints. Operational radiation evaluation required specially designed radiation detection systems onboard the spacecraft in addition to the use of satellite data, solar observatory support, and other liaison. Control and management of radioactive sources and radiation-generating equipment was important in minimizing radiation exposure of ground-support personnel, researchers, and the Apollo flight and backup crewmen.
Future tracking requirements and advantages over earth based stations justify the design of an orbiting, free flying very long base interferometry system to provide high resolution maps of celestial radio sources. Moderate technology development is required for the following: 30 meter to 60 meter diameter deployable parabolic antennas with less than 2 millimeters surface tolerance; a momentum wheel attitude control system with few arc/second accuracy; solar power design; a hydrogen maser atomic frequency standard; and the cryogenic receivers. The system must meet current Deep Space tracking capabilities as a minimum, and the technology must be compatible with system performance growth in the future. System lifetime must be ten years without major refurbishing.
Partial space heating for 97,000 square foot plant is supplied by 360 flat plate solar collectors; energy is sorted as heat in indoor 20,000 gallon water tank. System includes all necessary control electronics for year round operation. During December 1978, solar energy supplied 24.4 percent of building's space heating load.