Search NASA⌕ Search

SEARCH · Search NASA

Results for “System analysis.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

A new form of the Saint-Venant equations for variable topography

The solution stability of river models using the one-dimensional (1D) Saint-Venant equations can be easily undermined when source terms in the discrete equations do not satisfy the Lipschitz smoothness condition for partial differential equations. Although instability issues have been previously noted, they are typically treated as model implementation issues rather than as underlying problems associated with the form of the governing equations. This study proposes a new reference slope form of the Saint-Venant equations to ensure smooth slope source terms and eliminate one source of potential numerical oscillations. It is shown that a simple algebraic transformation of channel geometry provides a smooth reference slope while preserving the correct cross-section flow area and the total Piezometric pressure gradient that drives the flow. The reference slope method ensures the slope source term in the governing equations is Lipschitz continuous while maintaining all the underlying complexity of the real-world geometry. The validity of the mathematical concept is demonstrated with the open-source Simulation Program for River Networks (SPRNT) model in a series of artificial test cases and a simulation of a small urban creek. Validation comparisons are made with analytical solutions and the Hydrologic Engineering Center's River Analysis System (HEC-RAS) model. The new method reduces numerical oscillations and instabilities without requiring ad hoc smoothing algorithms.

54 ENVIRONMENTAL SCIENCES↗

MDSplus Yesterday, Today and Tomorrow

MDSplus is a data acquisition and analysis system used worldwide predominantly in the fusion research community. Development began 31 years ago by a collaboration of software developers who were charged with providing a data acquisition system for three new fusion experiments under construction: CMOD at MIT, ZTH at LANL and RFX at Padova, Italy. The design of MDSplus combined the functionality of MDS (MIT/Model Data System developed at MIT for the Alcator and Tara fusion experiments) with new features suggested by the developers from the other laboratories. The development of MDSplus used a RAD (rapid application development) approach before RAD became a mainstream methodology. MDSplus was implemented and ready for the initial operation of CMOD in 1991. Since that time, many other fusion facilities started using MDSplus for data acquisition and/or for exporting their data to other sites. Today MDSplus is still used around the world for fusion energy research, space exploration and other fields of science and technology. Work on MDSplus continues to enhance its capabilities, support more platforms, and improve its reliability. It is anticipated that MDSplus will continue to provide valuable tools for the fusion energy research community. This paper describes some of the history of the MDSplus software, the work that is currently underway, and the plans to enable MDSplus to continue to be available and supported long into the future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microelectromechanical pump utilizing porous silicon

A microelectromechanical (MEM) pump is disclosed which includes a porous silicon region sandwiched between an inlet chamber and an outlet chamber. The porous silicon region is formed in a silicon substrate and contains a number of pores extending between the inlet and outlet chambers, with each pore having a cross-section dimension about equal to or smaller than a mean free path of a gas being pumped. A thermal gradient is provided along the length of each pore by a heat source which can be an electrical resistance heater or an integrated circuit (IC). A channel can be formed through the silicon substrate so that inlet and outlet ports can be formed on the same side of the substrate, or so that multiple MEM pumps can be connected in series to form a multi-stage MEM pump. The MEM pump has applications for use in gas-phase MEM chemical analysis systems, and can also be used for passive cooling of ICs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ultra-Fast Sample Preparation for High-Throughput Proteomics

Sample preparation oftentimes can be the Achilles Heel of any analytical process and in the field of proteomics, preparing samples for mass spectrometric analysis is no exception. Current goals, concerning proteomic sample preparation on a large scale, include efforts toward improving reproducibility, reducing the time of processing and ultimately the automation of the entire workflow. This chapter reviews an array of recent approaches applied to bottom-up proteomics sample preparation to reduce the processing time down from hours to minutes. The current state-of-the-art in the field uses different energy inputs like microwave, ultrasound or pressure to perform the four basic steps in sample preparation: protein extraction, denaturation, reduction and alkylation, and digestion. No single energy input for enhancement of proteome sample preparation has become the universal gold standard. Instead, a combination of different energy inputs tend to produce the best results. This chapter further describes the future trends in the field such as the hyphenation of sample preparation with downstream detection and analysis systems. Finally, a detailed protocol describing the combined use of both pressure cycling technology and ultrasonic energy inputs to hasten proteomic sample preparation is presented.

59 BASIC BIOLOGICAL SCIENCES↗

LESSONS LEARNED IN AEROSOL MONITORING WITH THE RASA

The Radionuclide Aerosol Sampler/Analyzer (RASA) is an automated aerosol collection and analysis system designed by Pacific Northwest National Laboratory (PNNL) in the 1990's and is deployed in several locations around the world as part of the International Monitoring System (IMS) required under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The RASA operates unattended, save for regularly scheduled maintenance, iterating samples through a three-step process on a 24-hour interval. In its 15-year history, much has been learned from the operation and maintenance of the RASA that can benefit engineering updates or future aerosol systems. On 11 March 2011, a 9.0 magnitude earthquake and tsunami rocked the eastern coast of Japan, resulting in power loss and cooling failures at the Daiichi nuclear power plants in Fukushima Prefecture. Aerosol collections were conducted with the RASA in Richland, WA. We present a summary of the lessons learned over the history of the RASA, including lessons taken from the Fukushima incident, regarding the RASA IMS stations operated by the United States.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Distributed Online Conditions Database of the BaBar Experiment

This paper presents CDB - The distributed Conditions Database of the BaBar Experiment. CDB is the second major iteration of the database deployed in BaBar for production use as of October 2002. It replaced the original version of the database used through the first three years of the data taking. The new design and its implementation aims to improve the performance and scalability of the original database and addresses the emerging challenges of the distributed data production and analysis system of the Experiment.

99 GENERAL AND MISCELLANEOUS↗

Nuclear Proliferation and Grand Challenges

Nuclear engineer Dr. Kathy McCarthy leads systems analysis. She talks about proliferation and the grand challenges of nuclear R&D. For more information about INL energy research, visit http://www.facebook.com/idahonationallaboratory.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Method and apparatus for concentrating vapors for analysis

A pre-concentration device and a method are disclosed for concentrating gaseous vapors for analysis. Vapors sorbed and concentrated within the bed of the pre-concentration device are thermally desorbed, achieving at least partial separation of the vapor mixtures. The pre-concentration device is suitable, e.g., for pre-concentration and sample injection, and provides greater resolution of peaks for vapors within vapor mixtures, yielding detection levels that are 10-10,000 times better than direct sampling and analysis systems. Features are particularly useful for continuous unattended monitoring applications. The invention finds application in conjunction with, e.g., analytical instruments where low detection limits for gaseous vapors are desirable.

47 OTHER INSTRUMENTATION↗

A one-dimensional transient model of a single-stage, downward-firing entrained-flow gasifier

The integrated gasification combined cycle (IGCC) technology has emerged as an attractive alternative to conventional coal-fired power plant technology due to its higher efficiency and cleaner environmental performance especially with the option of CO{sub 2} capture and sequestration. The core unit of this technology is the gasifier whose optimal performance must be understood for efficient operation of IGCC power plants. This need has led a number of researchers to develop gasifier models of varying complexities. Whereas high-fidelity CFD models can accurately predict most key aspects of gasifier performance, they are computationally expensive and typically take hours to days to execute on high-performance computers. Therefore, faster one-dimensional (1D) partial differential equation (PDE)-based models are required for use in dynamic simulation studies, control system analysis, and training applications. A number of 1D gasifier models can be found in the literature, but most are steady-state and have limited application in the practical operation of the gasifier. As a result, 1D PDE-based dynamic models are needed to further study and predict gasifier performance under a wide variety of process conditions and disturbances. In the present study, a 1D transient model of a single-stage downward flow GE/Texaco-type gasifier has been developed. The model comprises mass, momentum and energy balances for the gas and solid phases. The model considers the initial gasification processes of water evaporation and coal devolatilization. In addition, the key heterogeneous and homogeneous chemical reactions have been modeled. The resulting time-dependent PDE model is solved using the well-known method of lines approach in Aspen Custom Modeler®, whereby the PDEs are discretized in the spatial domain and the resulting differential algebraic equations (DAEs) are then solved to obtain the transient response. The transient response of various gasifier performance parameters to certain disturbances commonly encountered in the real world operation of commercial IGCC plants will be presented. These disturbances include ramp and step changes in input variables such as coal flow rate, oxygen-to-coal ratio and water-to-coal ratio, among others. Comparison of gasifier model predictions to available dynamic data will also be discussed.

97 MATHEMATICS AND COMPUTING↗

Phosphor Thermometry Signal Analysis and Interpretation

Since the last International Temperature Symposium, phosphor thermometry has continued to mature with considerable attention given to combustion and turbine engine applications. More recently the utility to problems on the micro- and nano-scales has appreciated, particularly in regard to biological and biomedical situations. The method is therefore used for a wide range of situations. Signal interpretation is important and experience teaches that without sufficient care phosphor signals can be misleading. In order to advance the method, signal analysis investigations should prove fruitful. The specific aspect addressed here is the question of waveform sampling. A simple phenomenological approach is described that explores how the number of points digitized per waveform affects the measurement repeatability and accuracy. This is demonstrated for single shot signals and the average of 512 sequential waveforms. A bright temperature-independent luminescence signal from YVO4:Eu is sampled every 800 ps for a highly sampled condition and every 8 microseconds for a low sampled condition. When the average of 512 waveforms are compared for the two sampling conditions, they differ by only 0.4%. For the highly sampled case, a noisy single shot waveform compared to the averaged waveform differed by 1.8%. Future efforts on this subject will address intermediate and lower sampling rates. Also, variable window techniques should be explored that are especially important for non-log-linear signals. Investigations, such as this, give the developer the requisite information for designing analysis systems appropriate for the intended application in terms of precision, accuracy, and response time.

Fluorescence thermometry↗

Dynamic modeling of a single-stage downward firing, entrained flow gasifier

The gasifier is the heart of the integrated gasification combined cycle (IGCC), a technology that has emerged as an attractive alternative to conventional coal-fired power plant technology due to its higher efficiency and cleaner environmental performance especially with the option of CO{sub 2} capture and sequestration. Understanding the optimal performance of the gasifier is therefore paramount for the efficient operation of IGCC power plants. Numerous gasifier models of varying complexity have been developed to study the various aspects of gasifier performance. These range from simple one-dimensional (1D) process-type models to rigorous higher order 2-3D models based on computational fluid dynamics (CFD). Whereas high-fidelity CFD models can accurately predict most key aspects of gasifier performance, they are computationally expensive and typically take hours to days to execute on high-performance computers. Therefore, faster 1D partial differential equation (PDE)-based models are required for use in dynamic simulation studies, control system analysis, and training applications. A number of 1D gasifier models can be found in the literature, but most are steady-state models that have limited application in the practical operation of the gasifier. As a result, 1D PDE-based dynamic models are needed to further study and predict gasifier performance under a wide variety of process conditions and disturbances. In the current study, a 1D transient model of a single-stage downward-fired GE/Texaco-type entrained-flow gasifier has been developed. The model comprises mass, momentum and energy balances for the gas and solid phases. The model considers the initial gasification processes of water evaporation and coal devolatilization. In addition, the key heterogeneous and homogeneous chemical reactions have been modeled. The resulting time-dependent PDE model is solved using the well-known method of lines approach in Aspen Custom Modeler®, whereby the PDEs in the spatial domain are discretized and the resulting differential algebraic equations (DAEs) are then integrated over time using a dynamic integrator. The dynamic response results of the gasifier performance parameters to certain disturbances commonly encountered during practical operation are presented. These disturbances include ramp and step changes to input variables such as coal flow rate, oxygen-to-coal ratio and water-to-coal ratio among others. Comparison of model predictions to available dynamic data will also be discussed.

01 COAL, LIGNITE, AND PEAT↗

ECoG Cluster Flow v1.0

ECoG ClusterFlow is a novel multi-scale visual analysis system for the detailed exploration of dynamic functional connectivity graphs obtained through electrocorticography.

MURUGESAN, SUGEERTH↗

SINGLE PHASE ANALYTICAL MODELS FOR TERRY TURBINE NOZZLE

All BWR RCIC (Reactor Core Isolation Cooling) systems and PWR AFW (Auxiliary Feed Water) systems use Terry turbine, which is composed of the wheel with turbine buckets and several groups of fixed nozzles and reversing chambers inside the turbine casing. The inlet steam is accelerated through the turbine nozzle and impacts on the wheel buckets, generating work to drive the RCIC pump. As part of the efforts to understand the unexpected “self-regulating” mode of the RCIC systems in Fukushima accidents and extend BWR RCIC and PWR AFW operational range and flexibility, mechanistic models for the Terry turbine, based on Sandia National Laboratories’ original work, has been developed and implemented in the RELAP-7 code to simulate the RCIC system. RELAP-7 is a new reactor system code currently under development with the funding support from U.S. Department of Energy. The RELAP-7 code is a fully implicit code and the preconditioned Jacobian-free Newton-Krylov (JFNK) method is used to solve the discretized nonlinear system. This paper presents a set of analytical models for simulating the flow through the Terry turbine nozzles when inlet fluid is pure steam. The implementation of the models into RELAP-7 will be briefly discussed. In the Sandia model, the turbine bucket inlet velocity is provided according to a reduced-order model, which was obtained from a large number of CFD simulations. In this work, we propose an alternative method, using an under-expanded jet model to obtain the velocity and thermodynamic conditions for the turbine bucket inlet. The models include both adiabatic expansion process inside the nozzle and free expansion process out of the nozzle to reach the ambient pressure. The combined models are able to predict the steam mass flow rate and supersonic velocity to the Terry turbine bucket entrance, which are the necessary input conditions for the Terry Turbine rotor model. The nozzle analytical models were validated with experimental data and benchmarked with CFD simulations. The analytical models generally agree well with the experimental data and CFD simulations. The analytical models are suitable for implementation into a reactor system analysis code or severe accident code as part of mechanistic and dynamical models to understand the RCIC behaviors. The cases with two-phase flow at the turbine inlet will be pursued in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PLEXOS Input Data Generator

The PLEXOS Input Data Generator (PIDG) is a tool that enables PLEXOS users to better version their data, automate data processing, collaborate in developing inputs, and transfer data between different production cost modeling and other power systems analysis software. PIDG can process data that is in a generalized format from multiple input sources, including CSV files, PostgreSQL databases, and PSS/E .raw files and write it to an Excel file that can be imported into PLEXOS with only limited manual intervention.

Source record↗

Residential Energy Efficiency Potential: Alabama

Energy used by Alabama single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Energy Efficiency Potential: Arkansas

Energy used by Arkansas single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Energy Efficiency Potential: Florida

Energy used by Florida single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗