Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Systems and methods for power management using adaptive power split ratio

Methods and systems of power management in a hybrid vehicle are disclosed. A control system of the hybrid vehicle obtains battery temperature and catalyst temperature. The control system determines (a) whether the battery temperature is within an optimal battery temperature range and (b) whether the catalyst temperature is within an optimal catalyst temperature range. The control system determines a power split ratio (PSR) based on the determination of (a) and (b). The control system controls the engine and the motor-generator based on the determined PSR.

Ramakrishnan, Kesavan↗

Characterisation of strain-induced precipitation behaviour in microalloyed steels during thermomechanical controlled processing

The temperature at which thermomechanical controlled processing is undertaken strongly influences strain-induced precipitation (SIP) in microalloyed steels. In this study, the recrystallisation-precipitation-time-temperature curve was simulated to determine the full recrystallisation temperature, recrystallisation-stop temperature and the temperature where precipitation would occur at the shortest time. The calculated temperatures were verified by experimental testing for rolling between 1100 °C and 850 °C. On the basis of this a finishing deformation of 850 °C was chosen in order to maximise the precipitate number density formed in a fully unrecrystallised austenite. The orientation relationship between the SIP in austenite, and subsequent transformation to ferrite was identified by calculation from the coordinate transformation matrix, and by electron diffraction in the transmission electron microscope. The NbC formed as coherent/semi-coherent precipitates in the austenite, and remained coherent/semi-coherent in the ferrite, indicating a Kurdjumov-Sachs orientation relationship between the austenite and ferrite on transformation. - Highlights: •The austenite deformation temperature will influence strain-induced precipitation. •Precipitates are NbC, exhibiting an NaCl structure and lattice parameter 0.447 nm. •Fine NbC (< 10 nm) formed in austenite as coherent or semi-coherent precipitates. •Confirmed cube-on-cube orientation relationship between the NbC, the austenite and the ferrite.

36 MATERIALS SCIENCE↗

Optimal control of the electron temperature profile in DIII-D using machine learning surrogate models

The viability of the tokamak as a potential fusion reactor depends on the ability to keep the plasma in a stable regime while achieving temperatures, densities, and confinement times that are as high as possible. Tokamak scenario development attempts to find plasma regimes that achieve all of these conditions and are accessible with a given set of hardware constraints. This requires the ability to control plasma properties such as the normalized beta, the internal inductance, safety factor, rotation, etc. One property that has received less attention than some of the others, but is no less critical to achieving high performance, is the electron temperature (T e ) profile. In this work, Linear Quadratic Integral (LQI) control is used to develop a controller for the electron temperature profile in DIII-D. The controller is based on a linearized model derived from the transport equation that describes the evolution of the electron temperature, and includes contributions from the neural network surrogate models NubeamNet and MMMnet. Furthermore, the controller is tested in simulation using COTSIM, and is proven capable of tracking a target T e profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of Chemical Disorder in High Temperature Dislocation Glide in Refractory Multi-principal Element Alloys

Refractory multi-principal element alloys (RMPEAs) combine a chemically disordered lattice with a structurally ordered, single‐phase body‐centered cubic (bcc) crystal structure. Chemical fluctuations in these alloys give rise to significant energy barriers that impede dislocation motion. In this study, we use phase field dislocation dynamics to examine how spatial temperature fluctuations compete with randomness in energy barriers to affect the motion of long screw dislocations in three equi-atomic MoNbTa‐based RMPEAs: MoNbTa, MoNbTaW, and MoNbTaVW. Over a wide range of homologous temperatures (T h ≈ 0–0.6), we determined a screw dislocation ‘flow stress’ as the minimum applied stress to sustain continuous motion over a long excursion distance within a fixed timeframe. All three RMPEAs exhibit temperature dependent flow stress with three characteristic glide regimes: at low homologous temperatures, flow stress drops sharply, and screw glide remains planar and rectilinear; at intermediate homologous temperatures, the flow stress levels off as glide becomes planar but wavy; and at high homologous temperatures, flow stress plateaus as screws exhibit nonplanar, three‐dimensional motion. Glide kinetics and transition temperatures are controlled by the chemically induced fluctuations in the energy landscape. The rectilinear to wavy transition temperature is controlled by statistically weakest local barriers in the glide plane, whereas the wavy to 3D transition temperature is governed by statistically strongest local barriers. At low and intermediate homologous temperatures, the relative spread in energy barriers governs glide behavior by controlling the local kinetics of kink pair formation and kink pinning. At high homologous temperatures, the average barrier height governs the glide behavior by controlling the number of out-of-plane excursions during 3D glide. These findings reveal how random chemical fluctuations determine screw‐driven plasticity in RMPEAs, providing critical insight for the design of high temperature structural alloys.

Defects↗

Data Assimilation Experiments using Quality Controlled AIRS Version 5 Temperature Soundings

The AIRS Science Team Version 5 retrieval algorithm has been finalized and is now operational at the Goddard DAAC in the processing (and reprocessing) of all AIRS data. The AIRS Science Team Version 5 retrieval algorithm contains two significant improvements over Version 4: 1) Improved physics allows for use of AIRS observations in the entire 4.3 pm C02 absorption band in the retrieval of temperature profile T(p) during both day and night. Tropospheric sounding 15 pm C02 observations are now used primarily in the generation of cloud cleared radiances Ri. This approach allows for the generation of accurate values of Ri and T(p) under most cloud conditions. 2) Another very significant improvement in Version 5 is the ability to generate accurate case-by-case, level-by-level error estimates for the atmospheric temperature profile, as well as for channel-by- channel error estimates for Ri. These error estimates are used for quality control of the retrieved products. We have conducted forecast impact experiments assimilating AIRS temperature profiles with different levels of quality control using the NASA GEOS-5 data assimilation system. Assimilation of quality controlled T(p) resulted in significantly improved forecast skill compared to that obtained from analyses obtained when all data used operationally by NCEP, except for AIRS data, is assimilated. We also conducted an experiment assimilating AIRS radiances uncontaminated by clouds, as done Operationally by ECMWF and NCEP. Forecasts resulting from assimilated AIRS radiances were of poorer quality than those obtained assimilating AIRS temperatures.

SUsskind, Joel↗

Dynamic Simulation Modeling and Control of a Desiccant Assisted Direct-expansion Air Handling Unit

Desirable built environments demand simultaneous regulation of thermal comfort and indoor air quality (IAQ) with energy-efficient operation of heating, ventilation and air conditioning (HV AC) systems, which involves controls of temperature, humidity and airborne contaminants simultaneously. This paper presents the efforts of dynamic modeling and initial development control strategy for a desiccant-assisted multi-functional air handling unit (AHU) coupled with a direct-expansion rooftop unit (RTU) system, which aims to achieve multiple functions for indoor environment conditioning with energy efficient control. The RTU-AHU system includes a desiccant wheel for dehumidification and a conceptual direct air capture (DAC) filtering device for CO2 regulation. A Modelica-based dynamic model is developed for this conceptual system, and a simple decentralized control strategy is designed, which combines a differential-enthalpy based AHU return-air ratio control, a demand-controlled ventilation, and supply-air temperature humidity control via the RTU and DW controls. The proposed control method is evaluated with the Modelica simulation model for a selected set of scenarios

Pan, Chao↗

Improving Forecast Skill by Assimilation of Quality Controlled AIRS Version 5 Temperature Soundings

The AIRS Science Team Version 5 retrieval algorithm has been finalized and is now operational at the Goddard DAAC in the processing (and reprocessing) of all AIRS data. The AIRS Science Team Version 5 retrieval algorithm contains two significant improvements over Version 4: 1) Improved physics allows for use of AIRS observations in the entire 4.3 micron CO2 absorption band in the retrieval of temperature profile T(p) during both day and night. Tropospheric sounding 15 micron CO2 observations are now used primarily in the generation of cloud cleared radiances R(sub i). This approach allows for the generation of accurate values of R(sub i) and T(p) under most cloud conditions. 2) Another very significant improvement in Version 5 is the ability to generate accurate case-by-case, level-by-level error estimates for the atmospheric temperature profile, as well as for channel-by-channel error estimates for R(sub i). These error estimates are used for Quality Control of the retrieved products. We have conducted forecast impact experiments assimilating AIRS temperature profiles with different levels of Quality Control using the NASA GEOS-5 data assimilation system. Assimilation of Quality Controlled T(p) resulted in significantly improved forecast skill compared to that obtained from analyses obtained when all data used operationally by NCEP, except for AIRS data, is assimilated. We also conducted an experiment assimilating AIRS radiances uncontaminated by clouds, as done operationally by ECMWF and NCEP. Forecast resulting from assimilated AIRS radiances were of poorer quality than those obtained assimilating AIRS temperatures.

Susskind, Joel↗

Rate Controlling in Low-Temperature Standard NH 3 -SCR: Implications from Operando EPR Spectroscopy and Reaction Kinetics

Here, a series of seven Cu/SSZ-13 catalysts with Si/Al = 6.7 are used to elucidate key rate-controlling factors during low-temperature standard ammonia-selective catalytic reduction (NH 3 -SCR), via a combination of SCR kinetics and operando electron paramagnetic resonance (EPR) spectroscopy. Strong Cu-loading-dependent kinetics, with Cu atomic efficiency increasing nearly by an order of magnitude, is found when per chabazite cage occupancy for Cu ion increases from ~0.04 to ~0.3. This is due mainly to the release of intercage Cu transfer constraints that facilitates the redox chemistry, as evidenced from detailed Arrhenius analysis. Operando EPR spectroscopy studies reveal strong connectivity between Cu-ion dynamics and SCR kinetics, based on which it is concluded that under low-temperature steady-state SCR, kinetically most relevant Cu species are those with the highest intercage mobility. Transient binuclear Cu species are mechanistically relevant species, but their splitting and cohabitation are indispensable for low-temperature kinetics.

catalytic reactions↗

Wide-Temperature Electronics for Thermal Control of Nanosats

This document represents a presentation which examines the wide and low-temperature electronics required for NanoSatellites. In the past, larger spacecraft used Radioisotope Heating Units (RHU's). The advantage of the use of these electronics is that they could eliminate or reduce the requirement for RHU's, reduce system weight and simplify spacecraft design by eliminating containment/support structures for RHU's. The Glenn Research Center's Wide/Low Temperature Power Electronics Program supports the development of power systems capable of reliable, efficient operation over wide and low temperature ranges. Included charts review the successes and failures of various electronic devices, the IRF541 HEXFET, The NE76118n-Channel GaAS MESFET, the Lithium Carbon Monofluoride Primary Battery, and a COTS DC-DC converter. The preliminary result of wide/low temperature testing of CTS and custom parts and power circuit indicate that through careful selection of components and technologies it is possible to design and build power circuits which operate from room temperature to near 100K.

Dickman, John Ellis↗

Development of a prototype automatic controller for liquid cooling garment inlet temperature

The development of a computer control of a liquid cooled garment (LCG) inlet temperature is descirbed. An adaptive model of the LCG is used to predict the heat-removal rates for various inlet temperatures. An experimental system that contains a microcomputer was constructed. The LCG inlet and outlet temperatures and the heat exchanger outlet temperature form the inputs to the computer. The adaptive model prediction method of control is successful during tests where the inlet temperature is automatically chosen by the computer. It is concluded that the program can be implemented in a microprocessor of a size that is practical for a life support back-pack.

Weaver, C. S.↗

Increasing braking power and exhaust gas temperature

A controller may identify an indication to initiate an engine braking procedure associated with an engine of a machine. The controller may obtain, based on identifying the indication to initiate the engine braking procedure, information relating to a requested amount of engine braking power of the engine. The controller may cause one or more components of a variable geometry turbocharger (VGT) of the engine to adjust, and a throttle valve of the engine to adjust, based on the information relating to the requested amount of engine braking power of the engine.

Robel, Wade James↗

Adaptive control of interface by temperature and interface profile feedback in transparent multi-zone crystal growth furnace

The objective of this research is to control the dynamics of multizone programmable crystal growth furnaces. Due to the inevitable heat exchange among different heating zones and the transient nature of the process, the dynamics of multizone furnaces is time varying, distributed, and therefore complex in nature. Electrical power to heating zones and the translational speed of the ampoule are employed as inputs to control the dynamics. Structural properties of the crystal is the ultimate aim of this adaptive control system. These properties can be monitored in different ways. Following an order of complexity, these may include: (1) on line measurement of the material optical properties such as the refractive index of crystal; (2) on line x-ray imaging of the interface topology; (3) on line optical quantification of the interface profile such as the determination of concavity or convexity of the interface shape; and (4) on line temperature measurement at points closest to the material such as measurements of the ampoule's outside and inside surface temperatures. The research performed makes use of the temperature and optical measurements, specified in (3) and (4) as the outputs of furnace dynamics. However, if the instrumentation is available, the proposed control methodology can be extended to the measurements listed in (1) and (2).

Batur, Celal↗

Lower and upper threshold limit for artificial neural network based chilled and condenser water temperatures set-point control in a chilled water system

In this study, an ANN (artificial neural network) based real-time optimized control algorithm for a chilled water cooling system was developed and applied in an actual building to analyze its cooling energy saving effects through in-situ application and actual measurements. For this purpose, the cooling tower’s CndWT (condenser water temperature) and the chiller’s ChWT (chilled water temperature) were set as system control variables. To evaluate algorithm performance, the electric consumption and the COP (coefficient of performance) were compared and analyzed when ChWT and CndWTs were controlled conventionally and controlled based on the ANN. During the analysis, unexpected abnormal data was observed due to insufficient training data and limited consideration of OWBT (outdoor air wet-bulb temperature) when determining the CndWT set-point. Therefore, it is necessary to further build training data from a wider range of conditions and to set the lower limit of CndWT set-point to at least +3.6 °C above OWBT when the OWBT is higher than 23 °C, so that further energy savings can be achieved.

42 ENGINEERING↗

Sleep-wake responses of squirrel monkeys exposed to hyperdynamic environments

This study examines the sleep responses of primates to acute 3 Gz environments. To investigate this question, loosely-restrained squirrel monkeys were exposed to 70 minutes of 3 Gz during the day. The animals' behavioral state was polygraphically monitored (EEG, EMG, EOG) along with video and deep body temperature. During the control period, animals exhibited slow wave sleep (SWS) napping behavior. SWS occurred during approximately 20 percent of the control period. Body temperature was maintained at 38.7 C. At 3 Gz, SWS was inhibited for 5 minutes, after which SWS occurred at levels 50 percent lower than in the control period. During the post-centrifugation period, SWS was elevated above the control (50 percent) and hyperdynamic (100 percent) levels. Body temperature was depressed 1.5 C when the animals were at 3 Gz. Thus, hyperdynamic environments are capable of modifying primate sleep behavior, at least as a result of acute exposure. Further, the increased arousal in the hyperdynamic environment is correlated with a lower body temperature. This negative correlation differs from the normal positive correlation of arousal and body temperature.

Fuller, C. A.↗

Automatic thermal switch

Automatic thermal switch closes and opens heat-flow path in response to temperature changes. Control is used to regulate temperature in electronic circuitry or cryogenic refrigeration equipment.

Cunningham, J. W.↗

Exploiting the Temperature Dependence of Magnetic Susceptibility to Control Convection in Fundamental Studies of Solidification Phenomena

It is well known that convection is a dominant mass transport mechanism when materials are solidified on Earth's surface. This convection is caused by gradients in density (and therefore gravitational force) that are brought about by gradients in temperature, composition or both. Diffusion of solute is therefore dwarfed by convection and the study of fundamental parameters, such as dendrite tip shape and growth velocity in the absence of convection is nearly impossible. Significant experimental work has therefore been carried out in orbiting laboratories with the intent of minimizing convection by minimizing gravity. One of the best known experiments of this kind is the Isothermal Dendritic Growth Experiment (IDGE), supported by NASA. Naturally such experiments are costly and one objective of the present investigation is to develop an experimental method whereby convection can be- halted, in solidification and other experiments, on the surface. A second objective is to use the method to minimize convection resulting from the residual accelerations suffered by experiments in microgravity. The method to be used to minimize convection relies on the dependence of the magnetic susceptibility of a fluid on temperature or composition (whichever is driving convection). All materials experience a force when placed in a magnetic field gradient. The direction and magnitude of that force depend on the magnetic susceptibility of the material. Consequently the force will vary if the susceptibility varies with temperature or composition. With a magnetic field gradient in the right direction (typically upward) and of the right magnitude, this variation in the magnetic force can be made to exactly cancel the variation in the gravitational force. Expressed another way, normal buoyancy is exactly countered by a "magnetic buoyancy". To demonstrate the principle, a solution of MnC12 in water has been used. First the variation of the susceptibility of this paramagnetic solution with temperature and concentration was measured. Then a "cell", containing this solution and 50mm long by 15mm high by 155mm wide, was placed in a superconducting magnet at Marshall Space Flight Center. The magnetic field was measured at various positions within the bore of the magnet using a Hall effect probe. In this way, a position was found where the magnetic field gradient was predominantly upward; the magnitude of the gradient could then be adjusted by adjusting the current of the magnet. The ends of the cell consisted of machined copper blocks maintained at controlled temperatures by circulating water from constant temperature baths. The walls of the cell were of rectangular section glass tubing so that the cell contents could be seen. Velocities arising from thermal gradients within the cell were measured by particle image velocimetry (PIV). Particles used for this purpose were silver-coated hollow glass spheres of micrometers diameter and nearly the same density as the solution. A central vertical plane of the cell was illuminated by a laser beam passing through a cylindrical lens. Digital images of the particles were captured on a CCD camera and fed to a computer so that frame-to-frame movements of particles traveling with the fluid were captured. These images were employed to compute velocity maps using commercial PIV software. In a typical experiment the cold end of the cell was maintained at 10C and the warm end at 30 C. With no current in the magnet, i.e.- with natural -convection allowed to occur, the fluid was observed to circulate with an average speed of approximately 0.3 millimeters per second. It was visually apparent that this circulation was diminished as the current was increased. At currents of approximately 20A the flow was halted, to within the precision of the PIV measurements. At yet higher currents the convection was reversed with the hotter solution sinking and the cooler solution rising. At 40A this reversed convection had speeds averaging 0.43 millimeters per second. The measurements of susceptibility and density allow an estimate of the field gradient necessary to halt convection in the experiment. That estimate was 7.8T (squared) per meter and the convection was observed to halt in the magnet at a current giving 7.21T (squared) per meter from the magnetic field measurements. Calculations of the flow have been carried out using the computational fluid dynamics software FLUENT and show good agreement with the measurements.

Seybert, C. D.↗

Fast, high sensitivity dewpoint hygrometer

A dewpoint/frostpoint hygrometer that uses a surface moisture-sensitive sensor as part of an RF oscillator circuit with feedback control of the sensor temperature to maintain equilibrium at the sensor surface between ambient water vapor and condensed water/ice. The invention is preferably implemented using a surface acoustic wave (SAW) device in an RF oscillator circuit configured to generate a condensation-dependent output signal, a temperature sensor to measure the temperature of the SAW device and to distinguish between condensation-dependent and temperature-dependent signals, a temperature regulating device to control the temperature of the SAW device, and a feedback control system configured to keep the condensation-dependent signal nearly constant over time in the presence of time-varying humidity, corrected for temperature. The effect of this response is to heat or cool the surface moisture-sensitive device, which shifts the equilibrium with respect to evaporation and condensation at the surface of the device. The equilibrium temperature under feedback control is a measure of dewpoint or frostpoint.

Hoenk, Michael E.↗