At least 1,441 records · Page 80

Modeling, Simulation, and Experimental Verification of a 20-kW Series-Series Wireless Power Transfer System for a Toyota RAV4 Electric Vehicle

Wireless power transfer is going to play a major role in transportation electrification due the convenience, flexibility, safety, and high-efficiency. Achieving high power levels is important in order to reduce the charge times and provide more convenience to electric vehicle (EV) owners while keeping the efficiency high and electric and electromagnetic field emissions lower than the limits set by the international guidelines. This study presents a 20-kW wireless charging system designed for a Toyota RAV4 electric vehicle for stationary charging with a dc-to-dc (high-frequency inverter input to the vehicle battery terminals) efficiency exceeding 95% over four power conversion stages. Additionally, the modeling, analysis, and sensitivity of the wireless charging system are presented for series-series resonant tuning configuration.

Onar, Omer↗

SHINE Vacuum Pump Test Verification

Normetex pumps used world-wide for tritium service are no longer available. DOE and other researchers worldwide have spent significant funds characterizing this pump. Identification of alternate pumps is required for performance and compatibility with tritium gas. Many of the pumps that could be used to meet the functional performance requirements (e.g. pressure and flow conditions) of the Normetex pump have features that include the use of polymers or oils and greases that are not directly compatible with tritium service. This study assembles a test system to determine the flow characteristics for candidate alternate pumps. These tests are critical to the movement of tritium through the SHINE Tritium Purification System (TPS).

07 ISOTOPE AND RADIATION SOURCES↗

Verification of dosimetric accuracy on the TrueBeam STx: Rounded leaf effect of the high definition MLC

Purpose: The dosimetric leaf gap (DLG) in the Varian Eclipse treatment planning system is determined during commissioning and is used to model the effect of the rounded leaf-end of the multileaf collimator (MLC). This parameter attempts to model the physical difference between the radiation and light field and account for inherent leakage between leaf tips. With the increased use of single fraction high dose treatments requiring larger monitor units comes an enhanced concern in the accuracy of leakage calculations, as it accounts for much of the patient dose. This study serves to verify the dosimetric accuracy of the algorithm used to model the rounded leaf effect for the TrueBeam STx, and describes a methodology for determining best-practice parameter values, given the novel capabilities of the linear accelerator such as flattening filter free (FFF) treatments and a high definition MLC (HDMLC). Methods: During commissioning, the nominal MLC position was verified and the DLG parameter was determined using MLC-defined field sizes and moving gap tests, as is common in clinical testing. Treatment plans were created, and the DLG was optimized to achieve less than 1% difference between measured and calculated dose. The DLG value found was tested on treatment plans for all energies (6 MV, 10 MV, 15 MV, 6 MV FFF, 10 MV FFF) and modalities (3D conventional, IMRT, conformal arc, VMAT) available on the TrueBeam STx. Results: The DLG parameter found during the initial MLC testing did not match the leaf gap modeling parameter that provided the most accurate dose delivery in clinical treatment plans. Using the physical leaf gap size as the DLG for the HDMLC can lead to 5% differences in measured and calculated doses. Conclusions: Separate optimization of the DLG parameter using end-to-end tests must be performed to ensure dosimetric accuracy in the modeling of the rounded leaf ends for the Eclipse treatment planning system. The difference in leaf gap modeling versus physical leaf gap dimensions is more pronounced in the more recent versions of Eclipse for both the HDMLC and the Millennium MLC. Once properly commissioned and tested using a methodology based on treatment plan verification, Eclipse is able to accurately model radiation dose delivered for SBRT treatments using the TrueBeam STx.

60 APPLIED LIFE SCIENCES↗

High-accuracy Geant4 simulation and semi-analytical modeling of nuclear resonance fluorescence

Nuclear resonance fluorescence (NRF) is a photonuclear interaction that enables highly isotope-specific measurements in both pure and applied physics scenarios. High-accuracy design and analysis of NRF measurements in complex geometries is aided by Monte Carlo simulations of photon physics and transport, motivating Jordan and Warren (2007) to develop the G4NRF codebase for NRF simulation in Geant4. In this work, we enhance the physics accuracy of the G4NRF code and perform improved benchmarking simulations. The NRF cross section calculation in G4NRF, previously a Gaussian approximation, has been replaced with a full numerical integration for improved accuracy in thick-target scenarios. A high-accuracy semi-analytical model of expected NRF count rates in a typical NRF measurement is then constructed and compared against G4NRF simulations for both simple homogeneous and more complex heterogeneous geometries. Furthermore, agreement between rates predicted by the semi-analytical model and G4NRF simulation is found at a level of ~1% in simple test cases and ~3% in more realistic scenarios, improving upon the ~20% level of the initial benchmarking study and establishing a highly-accurate NRF framework for Geant4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification of bubble tracking method and DNS examinations of single- and two-phase turbulent channel flows

Direct numerical simulation (DNS) has been regarded as a reliable data source for the development and validation of turbulence models along with experiments. The realization of DNS usually involves a very fine mesh that should be able to resolve all relevant turbulence scales down to Kolmogorov scale [1]. As the most computationally expensive approach compared to other CFD techniques, DNS applications used to be limited to flow studies at very low Reynolds numbers. Thanks to the tremendous growth of computing power over the past decades, the simulation capability of DNS has now started overlapping with some of the most challenging engineering problems. One of those examples in nuclear engineering is the turbulent coolant flow inside reactor cores. Coupled with interface tracking methods (ITM), the simulation capability of DNS can be extended to more complicated two-phase flow regimes. Departure from nucleate boiling (DNB) is the limiting critical heat flux phenomena for the majority of accidents that are postulated to occur in pressurized water reactors (PWR) [2]. As one of the major modeling and simulation (M&S) challenges pursued by CASL, the prediction capability is being developed for the onset of DNB utilizing multiphase-CFD (M-CFD) approach. DNS (coupled with ITM) can be employed to provide closure law information for the multiphase flow modeling at CFD scale. In the presented work, research groups at NCSU and UND will focus on applying different ITM to different geometries. Higher void fraction flow analysis at reactor prototypical conditions will be performed, and novel analysis methods will be developed, implemented and verified for the challenging flow conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CFD Verification and Validation of Wire-Wrapped Pin Assemblies

TerraPower is participating in a cooperative project among industry, the national lab system, and academia to perform Verification and Validation (V and V) of Computational Fluid Dynamics (CFD) methods for predicting the flow and heat transfer within liquid-metal-cooled nuclear fuel assemblies with wire-wrapped fuel pins. This project, consisting of both experimental and numerical components, uses surrogate fluids and electrically heated fuel pins to substitute for the liquid metal coolant and the nuclear heat source. The experiments include both unheated assemblies to measure the flow velocities with Laser Doppler Velocimetry (LDV) and Particle Image Velocimetry (PIV), as well as heated assemblies to measure the temperatures of the fluid and the simulated fuel pins with thermocouples. Both sets of experiments also measure the pressure at multiple locations in the system. The numerical component of this work involves high-fidelity Large-Eddy Simulation (LES) modeling and industry-standard Reynolds-Averaged Navier-Stokes (RANS) modeling of the experiments. Furthermore, the experiments and simulations will be conducted on two duct geometries: the first is a non-deformed hexagonal duct that has flat internal duct faces that represents a beginning of life geometry. The other is a deformed duct where the internal hexagonal flow area enlarges then decreases along the axial height to represent the changes that occur to the duct geometry from pressure and irradiation effects in the core. This paper describes the methods and results of the industrial, RANS-based CFD code verification, solution verification, and solution validation. The V and V simulations are being performed for the following experiment test geometries: - Isothermal non-deformed bundle; - Heated non-deformed bundle; - Isothermal deformed bundle; - Heated deformed bundle. These flows have been computed at first with the pre-test design specifications, without the aid of any experimental results. Later, post-test calculations will be performed incorporating the actual test conditions and input from some of the experimental results. These RANS simulations of helically wire-wrapped fuel assemblies employ meshes of bare pins without the wire-wrap in the bundle. The effect of wire-wrap on the flow is accounted for by introducing a momentum source into the governing fluid equations. The momentum source is only applied to cells corresponding to the location of the wire-wrap, and its components in each cell are based on the local flow field. This methodology simplifies the geometry and mesh generation and reduces the cell count, while still capturing the effects of the wire-wrap. The momentum source approach is used for all of the assembly simulations performed in this study. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Shipper/receiver difference verification of spent fuel by use of PDET

Spent fuel storage pools in most countries are rapidly approaching their design limits with the discharge of over 10,000 metric tons of heavy metal from global reactors. Countries like UK, France or Japan have adopted a closed fuel cycle by reprocessing spent fuel and recycling MOX fuel while many other countries opted for above ground interim dry storage for their spent fuel management strategy. Some countries like Finland and Sweden are already well on the way to setting up a conditioning plant and a deep geological repository for spent fuel. For all these situations, shipments of spent fuel are needed and the number of these shipments is expected to increase significantly. Although shipper/receiver difference (SRD) verification measurements are needed by IAEA when the recipient facility receives spent fuel, these are not being practiced to the level that IAEA has desired due to lack of a credible measurement methodology and instrument that can reliably perform these measurements to verify non-diversion of spent fuel during shipment and confirm facility operator declarations on the spent fuel. In this paper, we describe a new safeguards method and an associated instrument, Partial Defect Tester (PDET), which can detect pin diversion from Pressurized Water Reactor (PWR) Spent Fuel Assemblies in an in-situ condition. The PDET uses multiple tiny neutron and gamma detectors in the form of a cluster and a simple, yet highly precise, gravity-driven system to obtain underwater radiation measurements inside a Pressurized Water Reactor (PWR) spent fuel assembly. The method takes advantage of the PWR fuel design which contains multiple guide tubes which can be accessed from the top. The data obtained in such a manner can provide spatial distribution of neutron and gamma flux within a spent fuel assembly. Our simulation study as well as validation measurements indicated that the ratio of the gamma signal to the thermal neutron signal at each detector location normalized to the peak ratio of all the detector locations gives a unique signature that is sensitive to missing pins. The signature is principally dependent on the geometry of the detector locations, and little sensitive to enrichment or burn-up variations. A small variation in the fuel bundle, such as a few missing pins, changes the shape of the signature to enable detection. After verification of the non-diversion of spent fuel pins, the neutron signal and gamma signal are subsequently used to verify the consistency of the operator declaration on the fuel burn-up and cooling time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A methodology for corrosion testing ODS steels in liquid tin under reactor conditions in HFIR

Liquid metal–based divertor concepts have promising attributes for application in fusion reactors. Liquid tin is being considered as one of those liquid metals due to its excellent thermophysical properties. However, tin is extremely corrosive to steels at elevated temperatures, and the coupled effects of corrosion with neutron irradiation for application in fusion reactors have not been quantified. Researchers at Oak Ridge National Laboratory (ORNL) have designed and irradiated a series of capsules in the High Flux Isotope Reactor (HFIR) to help address gaps in the literature with respect to coupled corrosion and neutron irradiation effects. The capsules are filled with solid tin designed to melt due to the gamma heating in HFIR and allow interaction with the specimens. The capsules contain a SiC thermometer for post-irradiation temperature verification. Five capsules were irradiated in HFIR for 10.5 days, accumulating 0.93 dpa in the FeCrAl specimens. Post-irradiation temperature verification was performed on the SiC thermometers, and temperatures were observed to be higher than what was expected from thermal models. An explanation for the model underprediction is given herein. In conclusion, the capsules described within this article are the first to irradiate liquid metal within the HFIR flux trap and demonstrated the safety basis for continued liquid coolant studies in HFIR.

FeCrAl↗

Smoothed particle hydrodynamics non-Newtonian model for ice-sheet and ice-shelf dynamics

Mathematical modeling of ice sheets is complicated by the non-linearity of the governing equations and boundary conditions. Standard grid-based methods require complex front tracking techniques and have limited capability to handle large material deformations and abrupt changes in bottom topography. As a consequence, numerical methods are usually restricted to shallow ice sheet and ice shelf approximations. We propose a new smoothed particle hydrodynamics (SPH) non-Newtonian model for coupled ice sheet and ice shelf dynamics. SPH, a fully Lagrangian particle method, is highly scalable and its Lagrangian nature and meshless discretization are well suited to the simulation of free surface flows, large material deformation, and material fragmentation. In this paper, SPH is used to study 3D ice sheet/ice shelf behavior, and the dynamics of the grounding line. The steady state position of the grounding line obtained from SPH simulations is in good agreement with laboratory observations for a wide range of simulated bedrock slopes, and density ratios, similar to those of ice and sea water. The numerical accuracy of the SPH algorithm is verif;ed by simulating Poiseuille flow, plane shear flow with free surface and the propagation of a blob of ice along a horizontal surface. In the laboratory experiment, the ice was represented with a viscous Newtonian fluid. In the present work, however, the ice is modeled as both viscous Newtonian fluid and non-Newtonian fluid, such that the effect of non-Newtonian rheology on the dynamics of grounding line was examined. The non-Newtonian constitutive relation is prescribed to be Glen’s law for the creep of polycrystalline ice. A V-shaped bedrock ramp is further introduced to model the real geometry of bedrock slope.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhancement of risk informed validation framework for external hazard scenario

In recent years, the U.S. Nuclear Regulatory Commission (USNRC) and the International Atomic Energy Agency (IAEA) have developed methodologies to assess the vulnerabilities of nuclear plants against site specific extreme hazards. In many cases, advanced simulation tools are being considered to simulate multi-physics, multi-scale phenomena and to evaluate vulnerability of nuclear facilities. The credibility of advanced simulation tools is assessed based on a formal verification, validation, and uncertainty quantification procedure. One of the key limitations in validation is the lack of relevant experimental data at system-level. This limitation leads to a decrease in the confidence of system-level risk predictions. Therefore, a robust validation framework is needed to formalize the confidence in predictive capability of advanced simulation results. Additionally, this study enhances the existing risk informed validation methodology, originally proposed by Kwag et al. [1] and Bodda et al. [2], by developing additional attributes and a new set of validation indicies for a complete and wider applicability of the framework. In this manuscript, the methodology to identify the critical path that leads to the system-level failure is illustrated. The overall validation is checked for completeness and consistency by comparing the critical path for both the system-level simulation and experimental models. The applicability of the code for an intended application is represented in terms of various maturity levels and helps in the process of decision making.

42 ENGINEERING↗

An Approach for Detecting Inconsistencies between Behavioral Models of the Software Architecture and the Code

In practice, inconsistencies between architectural documentation and the code might arise due to improper implementation of the architecture or the separate, uncontrolled evolution of the code. Several approaches have been proposed to detect the inconsistencies between the architecture and the code but these tend to be limited for capturing inconsistencies that might occur at runtime. We present a runtime verification approach for detecting inconsistencies between the dynamic behavior of the architecture and the actual code. The approach is supported by a set of tools that implement the architecture and the code patterns in Prolog, and support the automatic generation of runtime monitors for detecting inconsistencies. We illustrate the approach and the toolset for a Crisis Management System case study.

Code generation↗

ARC Software Validation Work for the FFTF Reactor

Extensive efforts have been carried out at ANL for the verification and validation of the Argonne Reactor Codes (ARC) software package currently used for the design of Versatile Test Reactor (VTR). The ARC software package consists of steady state neutronics and thermal hydraulics modeling capabilities which are being used by the VTR program to develop most of the VTR reactor design details which will be part of the licensing application. It is anticipated that this software will continue to be used for the design work and for initial operations although additional software may be introduced at a later time. The validation work was focused primarily on obtaining validation data consistent with VTR and usable for the ARC software. Because no critical facilities or operating fast spectrum reactors are available to do experiments for the VTR, the next best option is to identify historical experimental data that can be used as validation data. Early on in VTR, the ZPPR-15 set of experiments was identified as good validation data because of 1) the availability and quality of the data, 2) existing staff that are already familiar with the experimental machine and measurements, 3) most of the ZPPR-15 loadings of interest have already been processed into ARC models, and 4) a full uncertainty quantification has already been done for several loadings of ZPPR-15. The FFTF startup and operations data was identified as the most consistent reactor type that has validation data usable for VTR. Finally, the EBR-II fuel depletion measurements were identified as the best available validation data for VTR. It is important to note that both the FFTF and EBR-II reactors typically come with higher uncertainties than the ZPPR. In the frame of the discussed verification and validation efforts, the present document discusses the analysis of selected FFTF measurements included in the benchmark specifications of the International Reactor Physics Experiment (IRPhE) handbook. The FFTF reactor core configurations from the benchmark specification are presented in Section 2. The analysis is performed with the use of the ARC code suite available at ANL for fast reactor studies and is discussed in Section 3. The reactor parameters from the benchmark include criticality, neutron spectra, effective delayed neutron spectra, control rod worth, isothermal temperature coefficient and low energy gamma-ray spectra. The calculated values and the comparison with the experimental data is discussed in Sections 4 to 9 for each considered reactor parameter. Finally, conclusions are presented in Section 10.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Business Solutions Case Study: Marketing Zero Energy Homes: LifeStyle Homes, Melbourne, Florida

Building America research has shown that high-performance homes can potentially give builders an edge in the marketplace and can boost sales. But it doesn't happen automatically. It requires a tailored, easy to understand marketing campaign and sometimes a little flair. This case study highlights LifeStyle Homes’ successful marketing approach for their SunSmart home package, which has helped to boost sales for the company. SunSmart marketing includes a modified logo, weekly blog, social media, traditional advertising, website, and sales staff training. Marketing focuses on quality, durability, healthy indoor air, and energy efficiency with an emphasis on the surety of third-party verification and the scientific approach to developing the SunSmart package. With the introduction of SunSmart, LifeStyle began an early recovery, nearly doubling sales in 2010; SunSmart sales now exceed 300 homes, including more than 20 zero energy homes. Completed homes in 2014 far outpaced the national (19%) and southern census region (27%) recovery rates for the same period. As technology improves and evolves, this builder will continue to collaborate with Building America.

Advertising↗

The Atacama Cosmology Telescope: High-resolution component-separated maps across one-third of the sky

Observations of the millimeter sky contain valuable information on a number of signals, including the blackbody cosmic microwave background (CMB), Galactic emissions, and the Compton-$y$ distortion due to the thermal Sunyaev-Zel'dovich (tSZ) effect. Extracting new insight into cosmological and astrophysical questions often requires combining multi-wavelength observations to spectrally isolate one component. In this work, we present a new arcminute-resolution Compton-$y$ map, which traces out the line-of-sight-integrated electron pressure, as well as maps of the CMB in intensity and E-mode polarization, across a third of the sky (around 13,000 sq.~deg.). We produce these through a joint analysis of data from the Atacama Cosmology Telescope (ACT) Data Release 4 and 6 at frequencies of roughly 93, 148, and 225 GHz, together with data from the \textit{Planck} satellite at frequencies between 30 GHz and 545 GHz. We present detailed verification of an internal linear combination pipeline implemented in a needlet frame that allows us to efficiently suppress Galactic contamination and account for spatial variations in the ACT instrument noise. These maps provide a significant advance, in noise levels and resolution, over the existing \textit{Planck} component-separated maps and will enable a host of science goals including studies of cluster and galaxy astrophysics, inferences of the cosmic velocity field, primordial non-Gaussianity searches, and gravitational lensing reconstruction of the CMB.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-JeP3-04: Estimating 4D CBCT from Prior Information and Extremely Limited Angle Projections Using Structural PCA and Weighted Free-Form Deformation

Purpose: To investigate the feasibility of using structure-based principal component analysis (PCA) motion-modeling and weighted free-form deformation to estimate on-board 4D-CBCT using prior information and extremely limited angle projections for potential 4D target verification of lung radiotherapy. Methods: A technique for lung 4D-CBCT reconstruction has been previously developed using a deformation field map (DFM)-based strategy. In the previous method, each phase of the 4D-CBCT was generated by deforming a prior CT volume. The DFM was solved by a motion-model extracted by global PCA and a free-form deformation (GMM-FD) technique, using data fidelity constraint and the deformation energy minimization. In this study, a new structural-PCA method was developed to build a structural motion-model (SMM) by accounting for potential relative motion pattern changes between different anatomical structures from simulation to treatment. The motion model extracted from planning 4DCT was divided into two structures: tumor and body excluding tumor, and the parameters of both structures were optimized together. Weighted free-form deformation (WFD) was employed afterwards to introduce flexibility in adjusting the weightings of different structures in the data fidelity constraint based on clinical interests. XCAT (computerized patient model) simulation with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume. The estimation accuracy was evaluated by the Volume-Percent-Difference (VPD)/Center-of-Mass-Shift (COMS) between lesions in the estimated and “ground-truth” on board 4D-CBCT. Results: Among 6 different XCAT scenarios corresponding to respirational and anatomical changes from planning CT to on-board using single 30° on-board projections, the VPD/COMS for SMM-WFD was reduced to 10.64±3.04%/1.20±0.45mm from 21.72±9.24%/1.80±0.53mm for GMM-FD. Using 15° orthogonal projections, the VPD/COMS was further reduced to 1.91±0.86%/0.31±0.42mm based on SMM-WFD. Conclusion: Compared to GMM-FD technique, the SMM-WFD technique can substantially improve the 4D-CBCT estimation accuracy using extremely small scan angles to provide ultra-fast 4D verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Observation of the Crab Nebula with the HAWC Gamma-Ray Observatory

The Crab Nebula is the brightest TeV gamma-ray source in the sky and has been used for the past 25 years as a reference source in TeV astronomy, for calibration and verification of new TeV instruments. The High Altitude Water Cherenkov Observatory (HAWC), completed in early 2015, has been used to observe the Crab Nebula at high significance across nearly the full spectrum of energies to which HAWC is sensitive. HAWC is unique for its wide field of view, nearly 2 sr at any instant, and its high-energy reach, up to 100 TeV. HAWC’s sensitivity improves with the gamma-ray energy. Above ∼1 TeV the sensitivity is driven by the best background rejection and angular resolution ever achieved for a wide-field ground array. We present a time-integrated analysis of the Crab using 507 live days of HAWC data from 2014 November to 2016 June. The spectrum of the Crab is fit to a function of the form ϕ(E)=ϕ{sub 0}(E/E{sub 0}){sup −α−β⋅ln(E/E{sub 0})}. The data is well fitted with values of α = 2.63 ± 0.03, β = 0.15 ± 0.03, and log{sub 10}(ϕ{sub 0} cm{sup 2} s TeV)=−12.60±0.02 when E {sub 0} is fixed at 7 TeV and the fit applies between 1 and 37 TeV. Study of the systematic errors in this HAWC measurement is discussed and estimated to be ±50% in the photon flux between 1 and 37 TeV. Confirmation of the Crab flux serves to establish the HAWC instrument’s sensitivity for surveys of the sky. The HAWC all-sky survey will be the deepest survey of the northern sky ever conducted in the multi-TeV band.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-804: Verification of the BJR-25 Method of KQ Determination for CyberKnife Absolute Dosimetry

Purpose: Absolute calibration of the CyberKnife is performed using a 6cm-diameter cone defined at 80cm SAD. Since kQ is defined using PDD values determined using 10×10 cm fields at 100cm SSD, the PDD must be corrected in order to correctly apply the quality conversion factor. The accepted method is based on equivalent field-size conversions of PDD values using BJR25. Using the new InCise MLC system, the CK is capable of generating a rectangular field equivalent to 10×10 cm square field. In this study, a comparison is made between kQ values determined using the traditional BJR25 method and the MLC method introduced herein. Methods: First, kQ(BJR) is determined: a PDD is acquired using a 6cm circular field at 100cm SSD, its field size converted to an equivalent square, and PDD converted to a 10×10cm field using the appropriate BJR25 table. Maintaining a consistent setup, the collimator is changed, and the MLC method is used. Finally, kQ is determined using PDDs acquired with a 9.71×10.31cm at 100cm SSD. This field is produced by setting the field to a size of 7.77×8.25cm (since it is defined at 80cm SAD). An exact 10×10cm field since field size is relegated to increments of its leaf width (0.25cm). This comparison is made using an Exradin A1SL, IBA CC08, IBA CC13, and an Exradin A19. For each detector and collimator type, the beam injector was adjusted to give 5 different beam qualities; representing a range of clinical systems. Results: Averaging across all beam qualities, kQ(MLC) differed from kQ(BJR) by less than 0.15%. The difference between the values increased with detector volume. Conclusion: For CK users with standard cone collimators, the BJR25 method has been verified. For CK users the MLC system, a technique is described to determine kQ. Primary author is the President/Owner of Spectrum Medical Physics, LLC, a company which maintains contracts with Siemens Healthcare and Standard Imaging, Inc.

61 RADIATION PROTECTION AND DOSIMETRY↗

Homogenizing a Nickel-Based Superalloy: Thermodynamic and Kinetic Simulation and Experimental Results

If the chemical inhomogeneity profile is known a priori, kinetic modeling software such as diffusion-controlled transformations (DICTRA) can be used to model the homogenization kinetics of an alloy. In this study, the Scheil module within the Thermo-Calc software was used to predict the as-cast segregation present within the Ni-based superalloy Nimonic 105. The segregation profiles were read into DICTRA to refine the homogenization heat treatment of this alloy. The thermodynamic and kinetic modeling of the computationally predicted heat treatment and microstructure, and subsequent experimental verification on a real casting of Nimonic 105, are presented.

36 MATERIALS SCIENCE↗