Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator test facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Design Optimization of A generic Fissile Solution for Mo99 production using Electron Beam-based Neutron Generator using MCNP+CFD

Molybdenum-99 ( 99 Mo) is a medical isotope used in 80% of all medical imaging procedures today. However, 99 Mo is not directly administered to patients for imaging; its decay product, technetium-99m ( 99 mTc), is a metastable isotope with a half-life of ~6 hours. Such a short half-life does not allow for production, separation, and application to a patient before decaying further. Therefore, the solution is to produce the precursor to 99 mTc, 99 Mo. 99 Mo has a half-life of 66 hours, long enough to produce the material and send it to the desired location before it fully decays. Under National Nuclear Security Administration’s (NNSA) highly enriched uranium (HEU) minimization mission, the Material Management and Minimization (M3) office leads the Molybdenum-99 (Mo-99) program. A major goal of the Mo-99 program is to develop methods of producing 99 Mo using low enriched uranium (LEU) opposed to the traditionally used HEU domestically in the U.S. Internationally, LEU is the new standard for use in research reactors and isotope production facility. In this study, we introduce a generic fissile solution system for 99 Mo production facility meeting the design requirement of 1) LEU usage as fissile material and 2) subcritical fissile system coupled with a horizontal electron beam (E-beam) accelerator. The focus of this research is to optimize a fissile solution configuration for maximum 99 Mo production yield using MCNP model, and ultimately implement the optimized design with computational fluid dynamics (CFD) model to understand thermal hydraulic behavior and solution convection characteristic. The report consists of two parts: 1) isotope yield calculation and criticality analysis with a wide range of parametric test matrix, and 2) thermal hydraulic analysis for solution mixing and cooling assessment.

60 APPLIED LIFE SCIENCES↗

Emittance Measurements of the SSRL Gun Test Facility

A photocathode RF gun test stand is under construction in the injector vault of the Stanford Synchrotron Radiation Laboratory at SLAC. The goal of this facility is to produce an electron beam with a normalized emittance of 1-3[mm-mr], a longitudinal bunch duration of the order of 10[ps] FWHM and approximately 1[nC] of charge per bunch. The beam will be generated from a laser driven copper photocathode RF gun developed in collaboration with BNL, LBL and UCLA. The 3-5[MeV] beam from the gun will be accelerated using a SLAC three meter S-band accelerator section. The emittance of the electron beam will be measured through the use of quadrupole scans with phosphor screens and also a wire scanner. The details of the experimental setup will be discussed, and first measurements will be presented and compared with results from PARMELA simulations.

43 PARTICLE ACCELERATORS↗

Physics of Space Charge for Advanced Accelerators (Closeout Report)

The goal of this grant is to expand the basic understanding of the physics of extreme space charge in intense electron and ion beams, contributing to the development of future accelerators pushing the intensity frontier. This grant supported experimental, theoretical, and simulation studies. The University of Maryland Electron Ring (UMER), the centerpiece of our experimental program, is the leading facility in the U.S. for such space charge studies. UMER is a storage ring that uses high-current, low-energy electrons scaled to access an extended range of space charge intensities for the sole purpose of studying beam physics. During this period, we have awarded 3 Ph.D. degrees to students funded by this grant, published 22 papers, and delivered numerous contributed presentations at professional conferences. This grant marked a period of transition for our program. The total amount awarded was only about 1/3 of that requested, and the period shortened to 1 year 9 months (July 1, 2013 – Mar 31, 2015), instead of the requested 3 years. This severely curtailed the scope of the research from the original proposal. Nevertheless, we have demonstrated significant progress towards our stated goal. We have successfully extended our research program towards the important topic of nonlinear optics, formulating ideas for using UMER as a test bed of such concepts. Furthermore, we have solidified strong collaborations with leading laboratories such as Fermi National Accelerator Laboratory (FNAL), and GSI, Darmstadt in Germany. We have further performed groundbreaking studies on solitons and longitudinal shock-wave compression, a topic under consideration for GSI’s FAIR project. Significant results are reviewed below.

43 PARTICLE ACCELERATORS↗

Fabrication of THz corrugated wakefield structure and its high power test

We present overall process for developing terahertz (THz) corrugated structure and its beam-based measurement results. 0.2-THz corrugated structures were fabricated by die stamping method as the first step demonstration towards GW THz radiation source and GV/m THz wakefield accelerator. 150-μm thick disks were produced from an OFHC (C10100) foil by stamping. Two types of disks were stacked alternately to form 46 mm structure with ~ 170 corrugations. Custom assembly was designed to provide diffusion bonding with a high precision alignment of disks. The compliance of the fabricated structure have been verified through beam-based wakefield measurement at Argonne Wakefield Accelerator Facility. Both measured longitudinal and transverse wakefield showed good agreement with simulated wakefields. Measured peak gradients, 9.4 MV/m/nC for a long single bunch and 35.4 MV/m/nC for a four bunch trains, showed good agreement with the simulation.

43 PARTICLE ACCELERATORS↗

NASA Facility for the Study of Space Radiation Effects

Space particulate radiation from the Van Allen belts, solar flares, galactic cosmic, and manmade sources have energies and fluxes which are capable of producing damage in space mission payloads. NASA - Langley Research Center, Hampton, Virginia, has initiated the construction of a ground-based Space Radiation Effects Laboratory which simulates most of the space particulate energy spectrum and which can be used in a radiation research program for minimizing or eliminating deleterious radiation effects. A 600-megaelectronvolt synchrocyclotron of variable energy and electron accelerators from 1 to 10 megaelectronvolts will be included in the laboratory for accelerated testing. The plan of the proposed test areas reflects the latest advances in the state of the art as it pertains to the engineering and basic experimental requirements in flexibility, radiation background levels, shielding, and isolation. The laboratory operational plan permits three Virginia institutions of higher learning to cooperate with the Langley Research Center in carrying out radiation programs.

RADIATION EFFECT↗

Conversion of batch to molten glass, II: Dissolution of quartz particles

Quartz dissolution during the batch-to-glass conversion influences the melt viscosity and ultimately the temperature at which the glass forms. Batches to make a high-alumina borosilicate glass (formulated for the vitrification of nuclear waste) were heated as 5°C min-1 and quenched from the temperatures of 400-1200°C at 100°C intervals. As a silica source, the batches contained quartz with particles ranging from 5 to 195 µm. The content of unreacted quartz in the samples was determined with x-ray diffraction. Most of fine quartz has dissolved during the early batch reactions (at temperatures <800°C), whereas coarser quartz dissolved mostly in a continuous glass phase via diffusion. The mass-transfer coefficients were assessed from the data as functions of the initial particle sizes and the temperature. A series of batch was also tested that contained nitrated components and additions of sucrose known to accelerate melting. While sucrose addition had no discernible impact on quartz dissolution, nitrate batches melted somewhat more slowly than batches containing carbonates and hydroxides in addition to nitrates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Vehicle Flexibility on IRVE-II Flight Dynamics

The Inflatable Re-entry Vehicle Experiment II (IRVE-II) successfully launched from Wallops Flight Facility (WFF) on August 17, 2009. The primary objectives of this flight test were to demonstrate inflation and re-entry survivability, assess the thermal and drag performance of the reentry vehicle, and to collect flight data for refining pre-flight design and analysis tools. Post-flight analysis including trajectory reconstruction outlined in O Keefe3 demonstrated that the IRVE-II Research Vehicle (RV) met mission objectives but also identified a few anomalies of interest to flight dynamics engineers. Most notable of these anomalies was high normal acceleration during the re-entry pressure pulse. Deflection of the inflatable aeroshell during the pressure pulse was evident in flight video and identified as the likely cause of the anomaly. This paper provides a summary of further post-flight analysis with particular attention to the impact of aeroshell flexibility on flight dynamics and the reconciliation of flight performance with pre-flight models. Independent methods for estimating the magnitude of the deflection of the aeroshell experienced on IRVE-II are discussed. The use of the results to refine models for pre-flight prediction of vehicle performance is then described.

Bose, David M.↗

How DARHT Works - the World's Most Powerful X-ray Machine

The Dual Axis Radiographic Hydrodynamic Test (DARHT) facility at Los Alamos National Laboratory is an essential scientific tool that supports Stockpile Stewardship at the Laboratory. The World's most powerful x-ray machine, it's used to take high-speed images of mock nuclear devices - data that is used to confirm and modify advanced computer codes in assuring the safety, security, and effectiveness of the U.S. nuclear deterrent.

43 PARTICLE ACCELERATORS↗

Workshop on Pion-Kaon Interactions (PKI2018) Mini-Proceedings

This volume is a short summary of talks given at the PKI2018 Workshop organized to discuss current status and future prospects of pi -K interactions. The precise data on pi K interaction will have a strong impact on strange meson spectroscopy and form factors that are important ingredients in the Dalitz plot analysis of a decays of heavy mesons as well as precision measurement of Vus matrix element and therefore on a test of unitarity in the first raw of the CKM matrix. The workshop has combined the efforts of experimentalists, Lattice QCD, and phenomenology communities. Experimental data relevant to the topic of the workshop were presented from the broad range of different collaborations like CLAS, GlueX, COMPASS, BaBar, BELLE, BESIII, VEPP-2000, and LHCb. One of the main goals of this workshop was to outline a need for a new high intensity and high precision secondary KL beam facility at JLab produced with the 12 GeV electron beam of CEBAF accelerator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical Spectroscopy and Performance Tests with a Solid State Laser Ion Source at HRIBF

An ISOLDE-type hot-cavity laser ion source based on high-repetition-rate Ti:Sapphire lasers has been set up at the Holifield radioactive ion beam facility. To assess the feasibility of the all-solid-state laser system for applications at advanced radioactive ion beam facilities, spectroscopy and performance tests have been conducted with this source. The results of recent studies on excitation schemes, source efficiency, beam emittance and ion time structure are presented.

43 PARTICLE ACCELERATORS↗

First high gradient test results of a dressed 325 MHz superconducting single spoke resonator at Fermilab

A new superconducting RF cavity test facility has been commissioned at Fermilab in conjunction with first tests of a 325 MHz, {beta} = 0.22 superconducting single-spoke cavity dressed with a helium jacket and prototype tuner. The facility is described and results of full gradient, CW cavity tests with a high Q{sub ext} drive coupler are reported. Sensitivities to Q disease and externally applied magnetic fields were investigated. Results are compared to bare cavity results obtained prior to hydrogen degassing and welding into the helium jacket.

43 PARTICLE ACCELERATORS↗

Quantum chromodynamics resolution of the ATOMKI anomaly in 4 He nuclear transitions

Observations of anomalous angular correlations in electron-positron pairs produced from excited states of 4 He, 8 Be, and 12 C nuclei have been suggested as being due to the creation and subsequent decay of a new light particle of mass ~17MeV. In this work, we investigate the possibility that the source of the observed signals is a set of new excitation channels created by the 12-quark hidden-color Fock state within the 4 He nuclear wave function dubbed the “hexadiquark.” We calculate the invariant e + ⁢ e - mass spectrum for the electromagnetic transition from a new excitation of 4 He, estimating its differential and total decay width. We find that we can fit the shape of the anomalous signal with the QCD Fock state at excitation energy E* = 17.9 ± 1MeV and a Gaussian form factor for the electromagnetic decay. We address the physical issues with the fit parameters using properties of the hexadiquark state, in particular the three weakly repulsive 6 C interactions of SU⁡(3) C between diquark pairs. Experimental tests of our model are described in detail. In light of this work, we emphasize the need for independent experimental confirmation or refutation of the ATOMKI results as well as dedicated experiments to search for the proposed new excitations of 4 He and other a-cluster nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An inorganic coating and flexible regulating in situ of stent endothelialization by the controllable ion releasing

Highlights: • The Cu/Ti film with regulating the various responses of ECs and SMCs has been prepared. • The hemocompatibility could be adjusted via the ratio of Cu/Ti. • The volume and velocity of copper ion released from film was designed via the preparation processing. - Abstract: A facile approach to fabricate an inorganic coating with favorable blood compatibility and accelerating endothelialization is reported. The inorganic coating with various ratios of Cu and Ti atom are prepared on 316 L stainless steel by physical vapor deposition method. The phase composition and structure as well as the element concentration of the coating are investigated by X-ray diffraction and X-photoelectron energy spectrum. The hemolysis ratio, clotting time and platelet adhesion are utilized to characterize the materials’ hemocompatibility, the copper ion releasing was also investigated via immersing test. The result indicates that copper-titanium coating show good compatibility; however, as the ratio of Cu to Ti increases, the hemolysis ratio also increases. The endothelialization degree was accelerated owing to maintain less than 7.0 μg/ml of Cu{sup 2+} concentrate, and endothelial cells proliferate more readily than smooth muscle cells. The results demonstrate that this degradable copper-containing coating is suitable as a new surface modification for vascular stents.

36 MATERIALS SCIENCE↗

Uncertainty Aware Deep Learning for Fault Prediction Using Multivariate Time Series Signals

The superconducting radio-frequency cavities are a crucial component of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. When a cavity faults, beam delivery to experimental end users is disrupted. Prediction of cavity faults prior to onset is essential to reduce operation and maintenance costs. In this work, a parallel long short-term memory (LSTM)-convolution neural network (CNN)-based deep learning (DL) model is proposed to predict impending faults using pre-fault signals. Further, we introduce an uncertainty quantification approach using Monte Carlo dropout with the LSTM-CNN model to ascertain confidence in the prediction. The model was tested using multivariate time series signals from stable cavity operations and before faults. Initial results show that on the test dataset, the model can identify impending faults before their onset with an average 10-fold cross validation accuracy of 97.39% and a standard deviation of 0.12% using a 100-ms time window. It is also observed that the model performs better as the prediction time moves closer to the fault onset. For additional context, we compare the performance of the model with three machine-learning-based (ML) fault prediction models. Our proposed parallel LSTM-CNN-based DL method shows better performance than the ML-based methods.

Rahman, Md Monibor↗

Velocimetry Overview for visitors from the DOD

We are in the midst of a transformative period in which technological advances are making fundamental changes in the measurement techniques that form the backbone of nuclear weapon certification. Optical velocimetry has replaced electrical shorting pins in “Hydrotests,” which measure the dynamic implosion process. This advance has revolutionized nuclear weapons certification during the last 5 years. We can now measure the implosion process that drives a nuclear detonation with many orders of magnitude more resolution in both space and time than was possible just 10 years ago. It has been compared to going from Morse Code to HDTV, resulting in a dozen or more improvements in models of these weapons. These Hydrotests are carried out at LANL, LLNL and the NNSS, with the later holding the important role of allowing us to test with nuclear materials, in sub-critical configurations (i.e., no yield.) Each of these institutions has largely replaced pins with hundreds of channels of optical velocimetry. Velocimetry is non-contact and is used simultaneously with the X-ray capability of these facilities. The U1-a facility at NNSS pioneered this approach in the Gemini series in 2012, and continues to lead, both in channel count and technological advances. Close cooperation among LANL, LLNL and NSTec in these advances serves the complex by leveraging capabilities across sites and accelerating the pace of technical improvements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Description of FY25 Theory and Simulation Performance Target: Development of an integrated modeling framework for fusion reactor design and assessment

The urgency to deliver fusion power is growing now more than ever, with increasing pressure for both public programs and private companies to meet milestones timelines and overcome significant remaining technical challenges to ensure growth of a nascent fusion industry in time to meet rapidly growing clean energy demands. With incredible advancements in computation and years of investment in fusion model development and validation, integrated modeling is poised to fill a key role in accelerating the timeline to a fusion pilot plant (FPP). Future fusion pilot plants will operate in regimes far beyond current experience, and device design will rely on physics-based prediction and extrapolation. Many concepts will also rely on simulation to assess safety (shielding, tritium management, materials activation and lifetimes), economics and scalability before the decision to build. Importantly, integrated simulation can be used to reveal and solve the complexities of system integration that may otherwise not be apparent in physical components or models developed in isolation. New experimental test facilities that produce relevant conditions to validate and resolve key technical challenges for various subsystems (materials, blankets, fuel cycle, etc.) have been repeatedly called for by the fusion community but are not yet realized. Integrated modeling has an important role in identifying realistic load conditions (thermal, electromagnetic, plasma, neutron and photon loads, etc.) and defining the components and experiments for these test facilities in order to ensure meaningful validation that sufficiently reduces modeling uncertainties and technical risk for the full integrated reactor. The Fusion REactor Design and Assessment (FREDA) SciDAC project is building a component-based integrated modeling framework & data structure to enable self-consistent, multi-fidelity, iterative optimization workflows for the fusion reactor design process. FREDA aims to shorten the time to viable designs by providing a set of flexible workflows to support the various stages of the design process using an integrated model hierarchy, ranging from the simple analytic descriptions to the highest fidelity, theory-based plasma and engineering modeling developed by the fusion and fission communities. These tools are expected to be needed for timely support of FPP design in the milestone program and in the FIRE collaboratives. The plasma simulation backbone of FREDA is IPS-FASTRAN with newly developed coupled Core-Edge Pedestal-SOL (CESOL) workflows, which is being extended to the far-SOL region up to the plasma facing components. FREDA incorporates the FERMI engineering modeling suite and will enable self-consistent evaluation of the thermal shields, limiters, blanket, magnets, and other surrounding structures with predictions of temperatures, erosion, dpa, activation, tritium generation and transport, creep, corrosion, material degradation, etc. Parametric generation of 3D CAD enables rapid iteration of component geometry in response to plasma and loading specifications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Quasi-monoenergetic 6 MeV Gamma Facility at NASA Goddard Space Flight Center

The 6 MeV Gamma Facility has been developed at NASA Goddard Space Flight Center (GSFC) to allow in-house characterization and testing of a wide range of gamma-ray instruments such as pixelated CdZnTe detectors for planetary science and Compton and pair-production imaging telescopes for astrophysics. The 6 MeV Gamma Facility utilizes a circulating flow of water irradiated by 14 MeV neutrons to produce gamma rays via neutron capture on oxygen (O-16(n,p)N-16 yields O-16* yields O-16 + gamma). The facility provides a low cost, in-house source of 2.742, 6.129 and 7.117 MeV gamma rays, near the lower energy range of most accelerators and well above the 2.614 MeV line from the Th-228 decay chain, the highest energy gamma ray available from a natural radionuclide. The 7.13 s half-life of the N-16 decay allows the water to be irradiated on one side of a large granite block and pumped to the opposite side to decay. Separating the irradiation and decay regions allows for shielding material, the granite block, to be placed between them, thus reducing the low-energy gamma-ray continuum. Comparison between high purity germanium (HPGe) spectra from the facility and a manufactured source, Pu-238/C-13, shows that the low-energy continuum from the facility is reduced by a factor approx. 30 and the gamma-ray rate is approx.100 times higher at 6.129 MeV.

NASA↗

Evaluation of Temporal Diagnostic Techniques for Two-Bunch Facet Beam

Three temporal diagnostic techniques are considered for use in the FACET facility at SLAC, which will incorporate a unique two-bunch beam for plasma wakefield acceleration experiments. The results of these experiments will depend strongly on the the inter-bunch spacing as well as the longitudinal profiles of the two bunches. A reliable, singleshot, high resolution measurement of the beam's temporal profile is necessary to fully quantify the physical mechanisms underlying the beam driven plasma wakefield acceleration. In this study we show that a transverse deflecting cavity is the diagnostic which best meets our criteria. Based on our laboratory testing, numerical calculations, and simulations of the three single-shot temporal diagnostic devices, the X-band TCAV system is the best candidate for resolving FACET's two-bunch beam, with an estimated resolution of 7 {micro}m. Both the S-band TCAV system and the EO system could resolve the peak-to-peak separation of the two bunches in the FACET beam with estimated resolutions of 25 {micro}m and 30 {micro}m, respectively, but would be unable to resolve the temporal profiles of the individual bunches themselves. Because the TCAV signal is more easily interpreted and because the reliability of the EO system is less well known, however, the S-band TCAV system would be the next preferred option after the X-band TCAV system. The Fesca-200 streak camera, though simple, compact, and reliable, is unable to achieve a resolution that would be of use to FACET.

43 PARTICLE ACCELERATORS↗