Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Teledyne H1RG, H2RG, and H4RG Noise Generator

This paper describes the near-infrared detector system noise generator (NG) that we wrote for the James Webb Space Telescope (JWST) Near Infrared Spectrograph (NIRSpec). NG simulates many important noise components including; (1) white "read noise", (2) residual bias drifts, (3) pink 1/f noise, (4) alternating column noise, and (5) picture frame noise. By adjusting the input parameters, NG can simulate noise for Teledyne's H1RG, H2RG, and H4RG detectors with and without Teledyne's SIDECAR ASIC IR array controller. NG can be used as a starting point for simulating astronomical scenes by adding dark current, scattered light, and astronomical sources into the results from NG. NG is written in Python-3.4.

H2RG↗

Design and Development of the Astro-H 3-Stage ADR

The Japanese Astro-H mission will include the Soft X-ray Spectrometer (SXS) instrument provided by NASA/GSFC. The SXS will perform imaging spectroscopy in the soft x-ray band using a 6x6 array of silicon microcalorimeters operated at 50 mK. The detectors will be cooled by a 3-stage adiabatic demagnetization refrigerator (ADR). The configuration allows the ADR to operate with both a 1.3 K superfluid helium bath and a 4.5 K cryocooler as its heat sink. Initially, when liquid helium is present, the two coldest stages of the ADR will operate in a single-shot mode to cool the detectors from 1.3 K. The 3rd stage may be used to transfer heat from the liquid to the cryocooler to extend its lifetime. When the liquid is depleted, the two warmest stages will operate in a continuous mode to establish a 1.3 K base temperature, from which the cold stage will operate in a single-shot mode to cool the detectors. This paper will describe the design and operating modes of the ADR, as well as details of individual components.

Shirron, Peter J.↗

Some Recent Advances and Applications of Infrared Detector Technology at the Jet Propulsion Laboratory

The Jet Propulsion Laboratory has a long history in the development and application of infrared detector technology for the exploration of our planetary system. We will describe some recent applications of IR detector technology at JPL for ground based astronomy, the Earth Observing System, the Cassini Mission to Saturn, and the other proposed planetary missions. The infrared detector technologies to be discussed include single element, multiplexed linear and staring arrays, using a wide variety of infrared sensing materials including InSb, InGaAs, HgCdTe (PV and PC) and SiAs.

IR↗

Fermi Gamma-ray Space Telescope

The Fermi Gamma-ray Space Telescope, a key mission in multiwavelength and multimessenger studies, has been surveying the γ-ray sky from its low-Earth orbit since 2008. Its two scientific instruments, the Gamma-ray Burst Monitor (GBM) and the Large Area Telescope (LAT), cover 8 orders of magnitude in photon energy. The GBM consists of 12 Sodium Iodide detectors and 2 Bismuth Germinate detectors, covering the 10 keV - 40 MeV energy range, arrayed on two sides of the spacecraft so as to view the entire sky that is not occulted by the Earth. The LAT is a pair production telescope based on silicon strip trackers, a Cesium Iodide calorimeter, and a plastic scintillator anticoincidence system. It covers the energy range from about 20 MeV to more than 500 GeV, with a field of view of about 2.4 steradians. Thanks to their huge fields of view, the instruments can observe the entire sky with a cadence of about an hour for GBM and about three hours for LAT. All γ-ray data from Fermi become public immediately, enabling a broad range of multiwavelength and multimessenger research. Over 3000 γ-ray bursts (GRBs), including GRB 170817A associated with a neutron star merger detected in gravitational waves, and 5000 high-energy sources, including the blazar TXS 0506+056 associated with high-energy neutrinos, have been detected by the Fermi instruments. The Fermi Science Support Center provides a wide array of resources to enable scientific use of the data, including background models, source catalogs, analysis software, documentation, and a Help Desk.

gamma rays↗

Long-Wavelength Infrared (LWIR) Quantum Dot Infrared Photodetector (QDIP) Focal Plane Array

We have exploited the artificial atomlike properties of epitaxially self-assembled quantum dots for the development of high operating temperature long wavelength infrared (LWIR) focal plane arrays. Quantum dots are nanometer-scale islands that form spontaneously on a semiconductor substrate due to lattice mismatch. QDIPs are expected to outperform quantum well infrared detectors (QWIPs) and are expected to offer significant advantages over II-VI material based focal plane arrays. QDIPs are fabricated using robust wide bandgap III-V materials which are well suited to the production of highly uniform LWIR arrays. We have used molecular beam epitaxy (MBE) technology to grow multi-layer LWIR quantum dot structures based on the InAs/InGaAs/GaAs material system. JPL is building on its significant QWIP experience and is basically building a Dot-in-the-Well (DWELL) device design by embedding InAs quantum dots in a QWIP structure. This hybrid quantum dot/quantum well device offers additional control in wavelength tuning via control of dot-size and/or quantum well sizes. In addition the quantum wells can trap electrons and aide in ground state refilling. Recent measurements have shown a 10 times higher photoconductive gain than the typical QWIP device, which indirectly confirms the lower relaxation rate of excited electrons (photon bottleneck) in QDPs. Subsequent material and device improvements have demonstrated an absorption quantum efficiency (QE) of approx. 3%. Dot-in-the-well (DWELL) QDIPs were also experimentally shown to absorb both 45 deg. and normally incident light. Thus we have employed a reflection grating structure to further enhance the quantum efficiency. JPL has demonstrated wavelength control by progressively growing material and fabricating devices structures that have continuously increased in LWIR response. The most recent devices exhibit peak responsivity out to 8.1 microns. Peak detectivity of the 8.1 micrometer devices has reached approx. 1 x 10(exp 10) Jones at 77 K. Furthermore, we have fabricated the first long-wavelength 640x512 pixels QDP focal plane array. This QDIP focal plane may has produced excellent infrared imagery with noise equivalent temperature difference of 40 mK at 60K operating temperature. In addition, we have managed to increase the quantum efficiency of these devices from 0.1% (according to the data published in literature) to 20% in discrete devices. This is a factor of 200 increase in quantum efficiency. With these excellent results, for the first time QDIP performance has surpassed the QWIP performance. Our goal is to operate these long-wavelength detectors at much higher operating temperature than 77K which can be passively achieved in space. This will be a huge leap in high performance infrared detectors specifically applicable to space science instruments.

infrared imaging↗

Multi-Absorber Transition-Edge Sensors for X-Ray Astronomy Applications

We are developing multi-absorber Transition-Edge Sensors (TESs) for applications in x-ray astronomy. These position-sensitive devices consist of multiple x-ray absorbers each with a different thermal coupling to a single readout TES. Heat diffusion between the absorbers and the TES gives rise to a characteristic pulse shape corresponding to each absorber element and enables position discrimination. The development of these detectors is motivated by a desire to maximize focal plane arrays with the fewest number of readout channels. In this contribution we report on the first results from devices consisting of nine) 65 X 65 sq. microns Au x-ray absorbers) 5 microns thick. These are coupled to a single 35 X 35 sq. microns Mo/Au bilayer TES. These devices have demonstrated full-width-half-maximum (FWHM) energy resolution of 2.1 eV at 1.5 keV) 2.5 eV at 5.9 keV and 3.3 eV at 8 keV. This is coupled with position discrimination from pulse shape over the same energy range. We use a finite-element model to reproduce the measured pulse shapes and investigate the detector non-linearity with energy) which impacts on the devices position sensitivity and energy resolution.

Smith, S. J.↗

Two-Dimensional Interdigitated Pixel Detector for Energetic Particle Spectrometers

This paper describes a type of cosmic ray detector suitable for the construction of a small, low power space-based instrument to detect the energy and isotope of energetic nuclei, such as those produced by solar flares. The detector is similar to previous types of silicon PIN detectors where the fully depleted body of the wafer comprises intrinsic region of the PIN structure. The novel aspect of this detector is that the one surface is divided into a two-dimensional array of pixels, and that the collected holes are divided between a row and a column collector in each pixel, yielding both dimensions of position information from this side of the detector.

cosmic↗

Digital Mid-Wavelength and Long-Wavelength Infrared Focal Planes for SmallSat Applications

In this presentation, we will report our recent efforts in achieving high performance in Antimonides type-II superlattice (T2SL) based infrared photodetectors using the barrier infrared detector (BIRD) architecture. The high operating temperature (HOT) BIRD focal plane arrays (FPAs) offer the same high performance, uniformity, operability, manufacturability, and affordability advantages as InSb. However, mid-wavelength infrared (MWIR) HOT-BIRD FPAs can operate at significantly higher temperatures (>150K) than InSb FPAs (typically 80K). Moreover, while InSb has a fixed cutoff wavelength (~5.4 µm), the HOT-BIRD offers a continuous adjustable cutoff wavelength, ranging from ~4 µm to >15 µm, and is therefore also suitable for long wavelength infrared (LWIR) as well. The LWIR detectors based on the BIRD architecture has also demonstrated significant operating temperature advantages over those based on traditional p-n junction designs. Two 6U SmalSat missions CIRAS (Cubesat Infrared Atmospheric Sounder) and HyTI (Hyperspectral Thermal Imager) are based on JPL’s T2SL BIRD focal plane arrays (FPAs). Based on III-V compound semiconductors, the BIRD FPAs offer a breakthrough solution for the realization of low cost (high yield), high-performance FPAs with excellent uniformity and pixel-to-pixel operability. Furthermore, we will discuss the advantages of the utilization of all digital read out integrated circuits with HOT-BIRDs.

Pagano, Thomas↗

Results from the UCSD magnetic monopole search

The energy loss mechanism for slowly moving magnetic monopoles in helium provides a means of extending the search for such particles by ionization techniques to velocities approximately 3 X 1 million cm/sec (beta approximately equals 0.0001). Other gases (e.g., CH2 or CO2) mixed with helium will be ionized with high efficiency by collisions with excited helium atoms, thus allowing the use of large proportional chamber systems for the detection of the monopoles. The first reported results utilizing this mechanism was the experiment of Kajino, et al., using a detector with an area-solid angle product alpha time delta alpha of 24.7 square meters sr. They set a limit on the flux of monopoles of 7.2 x 10 to the 13th power cm(-2) sr(-1) sec(-1) at a 90% confidence level for beta 3x 0.0001. Here, the results of a He:CH2 proportional tube array designed to extend the velocity limit down to beta approximately 0.0001 are reported. The detector which has been operating at the University of California, San Diego (UCSD) since last summer, is a prototype for a larger array currently under construction at UCSD. The data presented here is from 200 days of live time with the prototype detector.

Masek, G. E.↗

Vacuum ultraviolet instrumentation for solar irradiance and thermospheric airglow

A NASA sounding rocket experiment was developed to study the solar extreme ultraviolet (EUV) spectral irradiance and its effect on the upper atmosphere. Both the solar flux and the terrestrial molecular nitrogen via the Lyman-Birge-Hopfield bands in the far ultraviolet (FUV) were measured remotely from a sounding rocket on October 27, 1992. The rocket experiment also includes EUV instruments from Boston University (Supriya Chakrabarti), but only the National Center for Atmospheric Research (NCAR)/University of Colorado (CU) four solar instruments and one airglow instrument are discussed here. The primary solar EUV instrument is a 1/4 meter Rowland circle EUV spectrograph which has flown on three rockets since 1988 measuring the solar spectral irradiance from 30 to 110 nm with 0.2 nm resolution. Another solar irradiance instrument is an array of six silicon XUV photodiodes, each having different metallic filters coated directly on the photodiodes. This photodiode system provides a spectral coverage from 0.1 to 80 nm with about 15 nm resolution. The other solar irradiance instrument is a silicon avalanche photodiode coupled with pulse height analyzer electronics. This avalanche photodiode package measures the XUV photon energy providing a solar spectrum from 50 to 12,400 eV (25 to 0.1 nm) with an energy resolution of about 50 eV. The fourth solar instrument is an XUV imager that images the sun at 17.5 nm with a spatial resolution of 20 arc-seconds. The airglow spectrograph measures the terrestrial FUV airglow emissions along the horizon from 125 to 160 nm with 0.2 nm spectral resolution. The photon-counting CODACON detectors are used for three of these instruments and consist of coded arrays of anodes behind microchannel plates. The one-dimensional and two-dimensional CODACON detectors were developed at CU by Dr. George Lawrence. The pre-flight and post-flight photometric calibrations were performed at our calibration laboratory and at the Synchrotron Ultraviolet Radiation Facility (SURF) at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland.

Woods, Thomas N.↗

Design and Fabrication of a Two-Dimensional Superconducting Bolometer Array

Large format, two dimensional arrays of close-packed bolometers will enable submillimeter cameras and spectrometers to obtain images and spectra orders of magnitude faster than present instruments. The South Pole Imaging Fabry-Perot Interferometer (SPIFI) for the AST/RO observatory and the Submillimeter and Far-InfraRed Experiment (SAFIRE) on the SOFIA airborne observatory will employ a large-format, two-dimensional, closepacked bolometer arrays. Both these instruments are imaging Fabry-Perot spectrometers operating at wavelengths between 100 micron and 700 micron. The array format is 16x32 pixels, using a 32-element multiplexer developed in part for this purpose. The low backgrounds achieved in spectroscopy require very sensitive detectors with NEPs of order 5x10(exp 18) W/square root of Hz. Superconducting detectors can be close-packed using the Pop-Up Detector (PUD) format, and SQUID multiplexers operating at the detector bas temperature can be intimately coupled to them. We have fabricated an engineering model array with this technology which features a very compact, modular approach for large format arrays.

Benford, Dominic↗

Improved Si:As BIBIB (Back-Illuminated Blocked-Impurity-Band) hybrid arrays

Results of a program to increase the short wavelength (less than 10 microns) detective quantum efficiency, eta/beta, of Si:As Impurity Band Conduction arrays are presented. The arrays are epitaxially grown Back-Illuminated Blocked (BIB) Impurity-Band (BIBIB) 10x50 detectors bonded to switched-FET multiplexers. It is shown that the 4.7 microns detective quantum efficiency increases proportionately with the thickness of the infrared active layer. A BIB array with a thick active layer, designed for low dark current, exhibits eta/beta = 7 to 9 percent at 4.7 microns for applied bias voltages between 3 and 5 V. The product of quantum efficiency and photoelectric gain, etaG, increases from 0.3 to 2.5 as the voltage increases from 3 to 5 V. Over this voltage range, the dark current increases from 8 to 120 e(-)s(-1) at a device temperature of 4.2 K and is under 70 e(-)s(-1) for all voltages at 2 K. Because of device gain, the effective dark current (equivalent photon rate) is less than 3 e(-)s(-1) under all operating conditions. The effective read noise (equivalent photon noise) is found to be less than 12 electrons under all operating conditions and for integration times between 0.05 and 100 seconds.

Herter, T.↗

Design and Fabrication of Two-Dimensional Semiconducting Bolometer Arrays for the High Resolution Airborne Wideband Camera (HAWC) and the Submillimeter High Angular Resolution Camera II (SHARC-II)

The High resolution Airborne Wideband Camera (HAWC) and the Submillimeter High Angular Resolution Camera II (SHARC 11) will use almost identical versions of an ion-implanted silicon bolometer array developed at the National Aeronautics and Space Administration's Goddard Space Flight Center (GSFC). The GSFC "Pop-Up" Detectors (PUD's) use a unique folding technique to enable a 12 x 32-element close-packed array of bolometers with a filling factor greater than 95 percent. A kinematic Kevlar(Registered Trademark) suspension system isolates the 200 mK bolometers from the helium bath temperature, and GSFC - developed silicon bridge chips make electrical connection to the bolometers, while maintaining thermal isolation. The JFET preamps operate at 120 K. Providing good thermal heat sinking for these, and keeping their conduction and radiation from reaching the nearby bolometers, is one of the principal design challenges encountered. Another interesting challenge is the preparation of the silicon bolometers. They are manufactured in 32-element, planar rows using Micro Electro Mechanical Systems (MEMS) semiconductor etching techniques, and then cut and folded onto a ceramic bar. Optical alignment using specialized jigs ensures their uniformity and correct placement. The rows are then stacked to create the 12 x 32-element array. Engineering results from the first light run of SHARC II at the CalTech Submillimeter Observatory (CSO) are presented.

Voellmer, George M.↗

Design and Fabrication of Two-Dimensional Semiconducting Bolometer Arrays for the High Resolution Airborne Wideband Camera (HAWC) and the Submillimeter High Angular Resolution Camera II (SHARC-II)

The High resolution Airborne Wideband Camera (HAWC) and the Submillimeter High Angular Resolution Camera II (SHARC II) will use almost identical versions of an ion-implanted silicon bolometer array developed at the National Aeronautics and Space Administration's Goddard Space Flight Center (GSFC). The GSFC 'Pop-up' Detectors (PUD's) use a unique folding technique to enable a 12 x 32-element close-packed array of bolometers with a filling factor greater than 95 percent. A kinematic Kevlar(trademark) suspension system isolates the 200 mK bolometers from the helium bath temperature, and GSFC - developed silicon bridge chips make electrical connection to the bolometers, while maintaining thermal isolation. The JFET preamps operate at 120 K. Providing good thermal heat sinking for these, and keeping their conduction and radiation from reaching the nearby bolometers, is one of the principal design challenges encountered. Another interesting challenge is the preparation of the silicon bolometers. They are manufactured in 32-element, planar rows using Micro Electro Mechanical Systems (MEMS) semiconductor etching techniques, and then cut and folded onto a ceramic bar. Optical alignment using specialized jigs ensures their uniformity and correct placement. The rows are then stacked to create the 12 x 32-element array. Engineering results from the first light run of SHARC II at the Caltech Submillimeter Observatory (CSO) are presented.

Voellmer, George M.↗

Recent Progress in Quantum Well Infrared Photodetector Research and Development at Jet Propulsion Laboratory

One of the simplest device realizations of the classic particle-in-the-box problem of basic quantum mechanics is the Quantum Well Infrared Photodetector (QWIP). In this paper we discuss the optimization of the detector design, material growth and processing that has culminated in realization of 15 micron cutoff 128x128 QWIP focal plane array camera, hand-held and palmsize 256x256 long-wavelength QWIP cameras and 648x480 long-wavelength cameras, holding forth great promise for myriad applications in 6-25 micron wavelength range in science, medicine, defense and industry.

quantum↗

Optical efficiency of far-infrared photoconductors

The present optimization of the geometry of far-IR photoconductive detectors with diffraction-limited throughput, on the basis of experimental and theoretical results, gives attention to the internal optical path relative to measured absorption length, photoconductive gain, uniformity of illumination, cosmic ray cross section, and design compatibility with the requirements of one- and two-dimensional arrays. It is demonstrated that a rod-shaped, square cross section detector geometry, having lateral face electrodes and a beveled backface with which to trap the radiation by total internal reflection, exhibits responsivity commensurate with that of the best available detectors in integrating cavities.

Wang, J.-Q.↗

InSb linear multiplexed FPAs for the CRAF/Cassini visible and infrared mapping spectrometer

This paper provides a review of a custom multiplexer circuit designed for use with a 256 element InSb linear array in the CRAF/Cassini VIMS instruments. The requirements, operation noise model and test results from a prototype 1 x 64 array are discussed. The infrared focal plane array (FPA) preliminary design and the impact of the new multiplexer on the instruments' predicted performance will be discussed. Emphasis will be placed on the multiplexer that was designed for the CRAF/Cassini missions. The FPA assembly combines electronic and optical components into a single hermetically sealed hybrid package. The detector configuration is that of a linear dual-multiplexed indium antimonide array with 256 elements, each 103 x 200 on 123-micron centers.

Niblack, Curtiss↗