Search NASA⌕ Search

SEARCH · Search NASA

Results for “base flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

The life science x-ray scattering beamline at NSLS-II

We report the current development status of the High Brightness X-ray Scattering for Life Sciences (or Life Science X-ray Scattering, LiX) beamline at the NSLS-II facility of Brookhaven National Laboratory. This instrument will operate in the x-ray energy range of 2.1-18 keV, provide variable beam sizes from 1 micron to ∼0.5 mm, and support user experiments in three scientific areas: (1) high-throughput solution scattering, in-line size exclusion chromatography and flow mixers-based time-resolved solution scattering of biological macro-molecules, (2) diffraction from single- and multi-layered lipid membranes, and (3) scattering-based scanning probe imaging of biological tissues. In order to satisfy the beam stability required for these experiments and to switch rapidly between different types of experiments, we have adopted a secondary source with refractive lenses for secondary focusing, a detector system consisting of three Pilatus detectors, and specialized experimental modules that can be quickly exchanged and each dedicated to a defined set of experiments. The construction of this beamline is on schedule for completion in September 2015. User experiments are expected to start in Spring 2016.

43 PARTICLE ACCELERATORS↗

Pressure distribution and velocity profiles in supersonic laminar wakes.

The method of integral relations is applied to calculate the characteristics of laminar wakes in supersonic flow past a wedge with a flat base. An earlier analysis of the flow in the critical recompression region is extended so that the flow near the base can be determined. Results are worked out for flow past a wedge of 10-deg semiangle at Mach number 6 and two values of Reynolds number. The pressure distribution along the axis is calculated, together with velocity profiles at various stations and streamline patterns in the recirculation region. Good agreement with experiment is found.

Holt, M.↗

A New Method for Predicting Turbulent Flow Reattachment Location: Application of Stratford Criterion for Reattaching Flows

A new method for predicting turbulent flow reattachment location has been developed. The method predicts the reattachment location using the surface static pressure distribution and requires only a single empirical parameter. The method is based on the well-known Stratford’s flow separation criterion, which results from an approximate solution to the equations of motion within the boundary layer. Because of the large pressure rise, the original Stratford separation criterion is not valid for reattaching flows. In order to apply the Stratford criterion for reattaching flows, the reference location was moved to the pressure drop conditions instead of pressure rise conditions. In addition, the pressure distribution was scaled using a technique that was originally introduced for supersonic base flows. A new empirical parameter was also obtained for the modified Stratford criterion. The method has been tested for 30 different separated flow configurations from the literature. The variety of test cases include subsonic flows, transonic flows, 2D flows, and axisymmetric flows, with experimental as well as high resolution numerical simulation results. The flow reattachment predictions with the new method agree very well with the reported data. The error is less than 5% and typically about 2%. The new method is an extremely simple and a quick way of finding the reattachment location. Given the complexities of the existing experimental techniques for finding the reattachment location, the method easily and quickly provides the flow reattachment location, which could be used to estimate the physical extent of separation bubbles, as a performance index for flow control methods, or to assess the predictive capability of turbulence models.

Flow reattachment location↗

Application of a solution adaptive grid scheme, SAGE, to complex three-dimensional flows

A new three-dimensional (3D) adaptive grid code based on the algebraic, solution-adaptive scheme of Nakahashi and Deiwert is developed and applied to a variety of problems. The new computer code, SAGE, is an extension of the same-named two-dimensional (2D) solution-adaptive program that has already proven to be a powerful tool in computational fluid dynamics applications. The new code has been applied to a range of complex three-dimensional, supersonic and hypersonic flows. Examples discussed are a tandem-slot fuel injector, the hypersonic forebody of the Aeroassist Flight Experiment (AFE), the 3D base flow behind the AFE, the supersonic flow around a 3D swept ramp and a generic, hypersonic, 3D nozzle-plume flow. The associated adapted grids and the solution enhancements resulting from the grid adaption are presented for these cases. Three-dimensional adaption is more complex than its 2D counterpart, and the complexities unique to the 3D problems are discussed.

Davies, Carol B.↗

Determination of Thermoelectric Module Efficiency A Survey

The development of thermoelectrics (TE) for energy conversion is in the transition phase from laboratory research to device development. There is an increasing demand to accurately determine the module efficiency, especially for the power generation mode. For many thermoelectrics, the figure of merit, ZT, of the material sometimes cannot be fully realized at the device level. Reliable efficiency testing of thermoelectric modules is important to assess the device ZT and provide the end-users with realistic values on how much power can be generated under specific conditions. We conducted a general survey of efficiency testing devices and their performance. The results indicated the lack of industry standards and test procedures. This study included a commercial test system and several laboratory systems. Most systems are based on the heat flow meter method and some are based on the Harman method. They are usually reproducible in evaluating thermoelectric modules. However, cross-checking among different systems often showed large errors that are likely caused by unaccounted heat loss and thermal resistance. Efficiency testing is an important area for the thermoelectric community to focus on. A follow-up international standardization effort is planned.

efficiency↗

Detection of Inorganic Salt-Based Homemade Explosives (HME) by Atmospheric Flow Tube–Mass Spectrometry

Using a commercial mass spectrometer interfaced with an atmospheric flow tube (AFT) allowed detection of a variety of inorganic compounds used as oxidizers in homemade explosives at picogram levels. The AFT provides reaction times between 3-5 seconds with flows of 6 L/min, enabling detection levels, after thermal desorption, similar to those previously demonstrated for RDX vapors in the low parts-per-quadrillion range. The thermal desorption of chlorate and perchlorate salts resulted in the production of the corresponding anions which have higher electron affinities than the nitrate reactant ions. A dielectric barrier discharge, used as the ionization source, produced the nitrate reactant ions. In some instances, the molecular salt formed adducts with the nitrate, chlorate, and/or perchlorate anions, giving insight into the original identity of the salt cation. Urea nitrate, guanidine nitrate, and potassium nitrate were also detected as adducts with the nitrate reactant ion. Direct room-temperature vapor detection of urea nitrate and hydrogen peroxide, which have relatively high vapor pressures compared to the other salts in this study, is also demonstrated. Room-temperature vapor detection of chlorate and perchlorate salts is possible by the addition of a dilute acid which converts the salt into a more volatile acidic form. A discussion of the instrumentation, methods used, and the ionization chemistry is provided.

chlorate, perchlorate, nitrate, detection, hydroge↗

Family of equations of state based on lattice QCD: Impact on flow in ultrarelativistic heavy-ion collisions

We construct a family of equations of state within a quasiparticle model by relating pressure, energy density, baryon density, and susceptibilities adjusted to first-principles lattice QCD calculations. The relation between pressure and energy density from lattice QCD is surprisingly insensitive to details of the simulations. Effects from different lattice actions, quark masses, and lattice spacings used in the simulations show up mostly in the quark-hadron phase transition region, which we bridge over by a set of interpolations to a hadron resonance gas equation of state. Within our optimized quasiparticle model we then examine the equation of state along isentropic expansion trajectories at small net baryon densities, as relevant for experiments and hydrodynamic simulations at RHIC and LHC energies. We illustrate its impact on azimuthal flow anisotropies and on the transverse momentum spectra of various hadron species.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commercialization Opportunity SFAI: An acoustic-based method for measuring composition and flow in containers, vessels, and pipes

The need to accurately discern the characteristics of materials within closed containers non-invasively is a problem that plagues many industrial sectors. In particular, characterizing multi-phase flow in pipes and other infrastructure is an ongoing challenge for many industries. Swept Frequency Acoustic Interferometry, or SFAI, and related technologies represent a portfolio that uses high-frequency sound to characterize liquids, gasses, mixtures, emulsions, and other fluids inside pipes and containers. SFAI offers the potential to measure material characteristics and two -and three -phase flows within pipes including flow rates and water- and gas-volume fractions. Such measurements can take place noninvasively both in accessible infrastructure and potentially downhole.

47 OTHER INSTRUMENTATION↗

Online Machine Learning for Accelerating Molecular Dynamics Modeling of Cells

We developed a biomechanics-informed online learning framework to learn the dynamics with ground truth generated with multiscale modeling simulation. It was built on Summit-like supercomputers, which were also used to benchmark and validate our framework on one physiologically significant modeling of deformable biological cells. We generalized the century-old equation of Jeffery orbits to a new equation of motion with additional parameters to account for the flow conditions and the cell deformability. Using simulation data at particle-based resolutions for flowing cells and the learned parameters from our framework, we validated the new equation by the motions, mostly rotations, of a human platelet in shear blood flow at various shear stresses and platelet deformability. Our online framework, which surrogates redundant computations in the conventional multiscale modeling by solutions of our learned equation, accelerates the conventional modeling by three orders of magnitude without visible loss of accuracy.

multiscale modeling↗

X-ray Imaging-Based Void Fraction Measurement in Saturated Flow Boiling Experiments with Seawater Coolant

Recent studies have shown that the presence of dissolved salts in water can exhibit peculiar flow boiling and two-phase flow regimes. Two-phase flow and convective flow boiling are typically characterized with the help of void fraction measurements. To quantitatively improve our understanding of two-phase flow and boiling phenomenon with seawater coolant, void fraction data are needed, which can not be obtained from optical imaging. In this paper, we present experimental void fraction measurements of saturated flow boiling of tap water and seawater using X-ray radiography. X-rays with a maximum energy level of 40 KeV were used for imaging the exit region of the heated test section. At lower heat flux levels, the two phase flow in seawater was bubbly and homogeneous in nature, resulting in higher void fractions as compared to tap water. With an increase in heat flux, the flow regime was similar to slug flow, and void fraction measurements approached similarity with tap water. The predicted pressure drop using the measured void faction shows good agreement with the measured total pressure drop across the test section, demonstrating the validity of the measurement process.

Eckels, Seth↗