Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

A multimodality vascular imaging phantom of an abdominal aortic aneurysm with a visible thrombus

Purpose: With the continuous development of new stent grafts and implantation techniques, it has now become technically feasible to treat abdominal aortic aneurysms (AAA) with challenging anatomy using endovascular repair with standard, fenestrated, or branched stent-grafts. In vitro experimentations are very useful to improve stent-graft design and conformability or imaging guidance for stent-graft delivery or follow-up. Vascular replicas also help to better understand the limitation of endovascular approaches in challenging anatomy and possibly improve surgical planning or training by practicing high risk clinical procedures in the laboratory to improve outcomes in the operating room. Most AAA phantoms available have a very basic anatomy, which is not representative of the clinical reality. This paper presents a method of fabrication of a realistic AAA phantom with a visible thrombus, as well as some mechanical properties characterizing such phantom. Methods: A realistic AAA geometry replica of a real patient anatomy taken from a multidetector computed tomography (CT) scan was manufactured. To demonstrate the multimodality imaging capability of this new phantom with a thrombus visible in magnetic resonance (MR) angiography, CT angiography (CTA), digital subtraction angiography (DSA), and ultrasound, image acquisitions with all these modalities were performed by using standard clinical protocols. Potential use of this phantom for stent deployment was also tested. A rheometer allowed defining hyperelastic and viscoelastic properties of phantom materials. Results: MR imaging measurements of SNR and CNR values on T1 and T2-weighted sequences and MR angiography indicated reasonable agreement with published values of AAA thrombus and abdominal components in vivo. X-ray absorption also lay within normal ranges of AAA patients and was representative of findings observed on CTA, fluoroscopy, and DSA. Ultrasound propagation speeds for developed materials were also in concordance with the literature for vascular and abdominal tissues. Conclusions: The mimicked abdominal tissues, AAA wall, and surrounding thrombus were developed to match imaging features of in vivo MR, CT, and ultrasound examinations. This phantom should be of value for image calibration, segmentation, and testing of endovascular devices for AAA endovascular repair.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-205: Improving Quality Assurance of HDR Brachytherapy: Verifying Agreement Between Planned and Delivered Dose Distributions Using DICOM RTDose and Advanced Film Dosimetry

Purpose: HDR brachytherapy is undergoing significant development, and quality assurance (QA) checks must keep pace. Current recommendations do not adequately verify delivered against planned dose distributions: This is particularly relevant for new treatment planning system (TPS) calculation algorithms (non TG-43 based), and an era of significant patient-specific plan optimisation. Full system checks are desirable in modern QA recommendations, complementary to device-centric individual tests. We present a QA system incorporating TPS calculation, dose distribution export, HDR unit performance, and dose distribution measurement. Such an approach, more common in external beam radiotherapy, has not previously been reported in the literature for brachytherapy. Methods: Our QA method was tested at 24 UK brachytherapy centres. As a novel approach, we used the TPS DICOM RTDose file export to compare planned dose distribution with that measured using Gafchromic EBT3 films placed around clinical brachytherapy treatment applicators. Gamma analysis was used to compare the dose distributions. Dose difference and distance to agreement were determined at prescription Point A. Accurate film dosimetry was achieved using a glass compression plate at scanning to ensure physically-flat films, simultaneous scanning of known dose films with measurement films, and triple-channel dosimetric analysis. Results: The mean gamma pass rate of RTDose compared to film-measured dose distributions was 98.1% at 3%(local), 2 mm criteria. The mean dose difference, measured to planned, at Point A was -0.5% for plastic treatment applicators and -2.4% for metal applicators, due to shielding not accounted for in TPS. The mean distance to agreement was 0.6 mm. Conclusion: It is recommended to develop brachytherapy QA to include full-system verification of agreement between planned and delivered dose distributions. This is a novel approach for HDR brachytherapy QA. A methodology using advanced film dosimetry and gamma comparison to DICOM RTDose files has been demonstrated as suitable to fulfil this need.

07 ISOTOPE AND RADIATION SOURCES↗

The CNAO dose delivery system for modulated scanning ion beam radiotherapy

Purpose: This paper describes the system for the dose delivery currently used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. Methods: CNAO Foundation, Istituto Nazionale di Fisica Nucleare and University of Torino have designed, built, and commissioned a dose delivery system (DDS) to monitor and guide ion beams accelerated by a dedicated synchrotron and to distribute the dose with a full 3D scanning technique. Protons and carbon ions are provided for a wide range of energies in order to cover a sizable span of treatment depths. The target volume, segmented in several layers orthogonally to the beam direction, is irradiated by thousands of pencil beams which must be steered and held to the prescribed positions until the prescribed number of particles has been delivered. For the CNAO beam lines, these operations are performed by the DDS. The main components of this system are two independent beam monitoring detectors, called BOX1 and BOX2, interfaced with two control systems performing the tasks of real-time fast and slow control, and connected to the scanning magnets and the beam chopper. As a reaction to any condition leading to a potential hazard, a DDS interlock signal is sent to the patient interlock system which immediately stops the irradiation. The essential tasks and operations performed by the DDS are described following the data flow from the treatment planning system through the end of the treatment delivery. Results: The ability of the DDS to guarantee a safe and accurate treatment was validated during the commissioning phase by means of checks of the charge collection efficiency, gain uniformity of the chambers, and 2D dose distribution homogeneity and stability. A high level of reliability and robustness has been proven by three years of system activity needing rarely more than regular maintenance and working with 100% uptime. Four identical and independent DDS devices have been tested showing comparable performances and are presently in use on the CNAO beam lines for clinical activity. Conclusions: The dose delivery system described in this paper is one among the few worldwide existing systems to operate ion beam for modulated scanning radiotherapy. At the time of writing, it has been used to treat more than 350 patients and it has proven to guide and control the therapeutic pencil beams reaching performances well above clinical requirements. In particular, in terms of dose accuracy and stability, daily quality assurance measurements have shown dose deviations always lower than the acceptance threshold of 5% and 2.5%, respectively.

60 APPLIED LIFE SCIENCES↗

SU-E-T-600: Patient Specific IMRT Verification Using a Phosphor-Screen Based Geometric QA System: A Preliminary Study

Purpose: Raven QA (JPLC, MD) is a unified and comprehensive quality assurance system for QA of TG-142, which use a phosphor screen, a mirror system and a camera. It is to test if this device can be used for IMRT QA dosimetry. Methods: A lung IMRT case is used deliver dose to Raven QA. Accuracy of dose distribution of 5cm slab phantom using Eclipse planning system (Varian) has been confirmed both from a Monte Carlo Simulation and from a MapCheck (SunNuclear) measurement. Geometric distortion and variation of spatial dose response are corrected after background subtraction. A pin-hole grid plate is designed and used to determine the light scatter in the Raven QA box and the spatial dose response. Optic scatter model was not applied in this preliminary study. Dose is normalized to the response of the 10×10 field and the TMR of 5cm depth was considered. Results: Time to setup the device for IMRT QA takes less than 5 minutes as other commercially available devices. It shows excellent dose linearity and dose rate independent, less than 1 %. Background signal, however, changes for different field sizes. It is believed to be due to inaccurate correction of optic scatter. Absolute gamma (5%, 5mm) passing rate was higher than 95%. Conclusion: This study proves that the Raven QA can be used for a patient specific IMRT verification. Part of this study is supported by the Maryland Industrial Partnership Grant.

61 RADIATION PROTECTION AND DOSIMETRY↗

Incorporation of Novel Nanostructured Materials into Solar Cells and Nanoelectronic Devices

Each of the investigators on this project has had significant accomplishments toward the production of semiconductor nanoparticles, particles, and thin films and attempts to incorporate these materials into photovoltaics or sensors; to use them for improving fluorescence diagnostics; or to employ them as cancer fighting agents. The synthesis and characterization of the nanomaterials, and more recently the device construction and testing of these materials, have been the subject of several publications and presentations by team members. During the course of the investigations, several students were fully involved as part of their graduate and undergraduate training. The nature of these projects in material development dictates that the students have gained significant experience in a diverse array of material-related topics.

14 SOLAR ENERGY↗

Application and Continued Development of Thin Faraday Collectors as a Lost Ion Diagnostic for Tokamak Fusion Plasmas

This report summarizes the accomplishment of sixteen years of work toward the development of thin foil Faraday collectors as a lost energetic ion diagnostic for high temperature magnetic confinement fusion plasmas. Following initial, proof of principle accelerator based studies, devices have been tested on TFTR, NSTX, ALCATOR, DIII-D, and JET (KA-1 and KA-2). The reference numbers refer to the attached list of publications. The JET diagnostic KA-2 continues in operation and hopefully will provide valuable diagnostic information during a possible d-t campaign on JET in the coming years. A thin Faraday foil spectrometer, by virtue of its radiation hardness, may likewise provide a solution to the very challenging problem of lost alpha particle measurements on ITER and other future burning plasma machines.

43 PARTICLE ACCELERATORS↗

Dynamically and continuously tunable infrared photodetector using carbon nanotubes

This report details the progress m ade in realizing a tunable photodetector based on carbon nanotubes. Results are presented for the theory and modeling of the electronic and optical properties of carbon nanotubes, the fabrication of nanotube devices, their electrical testing, and their optoelectronic characterization. The effects of gamma and proton irradiation are also discussed.

Léonard, François↗

What Limits the Gap in a Flat Dechirper for an X-ray FEL

In a linac-based X-ray free electron laser (FEL) there is often a need for energy chirp control of the beam before it enters the undulator. In a corrugated, metallic beam pipe in round geometry is suggested and analyzed as a device that can be used to passively “dechirp” the beam. Compared to round geometry, flat geometry—having the beam pass between two flat, corrugated plates—has the advantage of allowing the dechirper strength to be adjustable by changing the separation of the plates. And, indeed, such a device was recently tested in a proof-of-principle experiment at the PAL injector test facility in Pohang, Republic of Korea, and another at BNL’s ATF. One disadvantage of flat geometry is that, in addition to the usual dipole wakefield that is excited when the beam passes through the structure off axis, there is also a quadrupole wake excited, even when structure and beam are perfectly aligned.

ACCPHY↗

Spatially Tracked Hand-held Gamma Camera for Surgery

The goal of the project was to develop and test a 3-dimensional (3D) imaging technology designed to overcome limitations of current non-imaging lymph node mapping methods by integrating a newly developed, unique hand-held gamma camera (HGC) into a platform for freehand SPECT (single photon emission computed tomography). Sentinel lymph node biopsy is a vital component of surgical oncology in the process of establishing the extent of disease and likelihood of metastasis. The team was successful in the development and testing of the device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single Channel Silicon Photomultiplier Based Surgical Probe

The goal of the project was to develop and test a prototype single-use probe that can reduce the chance of infection of patients during lymph node surgery by incorporating a newly developed light detector, a silicon photomultiplier (SiPM), into a non-imaging gamma-ray detection platform. Sentinel lymph node biopsy is a vital component of surgical oncology in the process of establishing the extent of disease and likelihood of metastasis. The team was successful in the development and testing of the device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Building Towards Discovery: Preparing for New Physics at the LHC [Final papers]

Particle physics today is at a crossroads. The Standard Model (SM) has survived four decades of experimental scrutiny and spurred multiple landmark discoveries, culminating with the 2012 discovery of the Higgs boson at the Large Hadron Collider (LHC). Yet we know that this model is incomplete. We live in a universe dominated by matter and energy unaccounted for by the SM– and the Higgs boson itself is improbably light. It falls to the current generation of high-energy physicists to go beyond the model and enter a new era of discovery. Andeen is leading a new research group at the University of Texas at Austin (UT-Austin) that is endeavoring to reveal novel physical phenomena through the discovery of new particles with the ATLAS detector at the LHC. A key element of our experience thus far has been collaborating closely with theorists to identify both interesting new physics models. In addition we work closely with electrical engineers in detector development. Our approach is therefore unique in its integration of theory, analysis and instrumentation, and is encapsulated in a three-pronged strategy. First is the essential task of analyzing our rapidly expanding dataset. I am directing my group in searches for vector-like quarks (VLQs). Should they exist, these hypothetical particles would indicate physics scenarios beyond the SM. Experimental constraints suggest VLQs decay preferentially to a third generation quark and a Higgs, W or Z boson. Today at 13 TeV, both multi-lepton (electron and muon) and jet substructure signatures are sensitive to identifying the VLQ decay products. The large Run 2 dataset (collected through 2018) of up to 150 fb -1 will allow us to simultaneously use multi-lepton signatures with jet-substructure in searches for new physics. UT-Austin is well positioned to be a leader in this area. Prof. P. Onyisi’s postdoctoral researchers and graduate students are searching for ttH signatures in three- and four-lepton channels and we benefit from their experience. We are also aided by the availability of the Texas Advanced Computing Center, which provides us with easy access to several high performance computing (HPC) systems. My previous experience in VLQ searches propels the work today. I have published both the first investigation into the single production of top partners (signatures of composite Higgs Models) of any LHC experiment 1 as well as one of the first analyses utilizing jet-substructure techniques to search for the single production of vector-like quarks. 2 Adding to this is my group’s work with the Liquid Argon (LAr) calorimeter, the primary instrument we use in detecting electrons. Second, my group is contributing to the operations of the LAr calorimeter while preparing to install and commission new electronic hardware (the Phase 1 upgrade) to this crucial component of the ATLAS detector. I have played a leading role in the development of a critical, radiation-hard, high-speed Analog-to-Digital Convertor (ADC) that is essential inselecting data collected by the LAr calorimeter. 3 This upgrade will improve the e!ciency with which we can select events in our detector. Postdoctoral researcher N. Nikiforou (based at CERN May 2016 onward) and graduate students (one based at CERN from the start of 2018 onward, with one additional graduate students from summer 2018) are growing our already deep experience in the operation of the LAr calorimeter to prepare for installation and commissioning of the new trigger readout in 2018-2019. My group will then be positioned to be the first to exploit the potential of the improved triggers in our multi-lepton searches for new physics. Third, a suite of preparations for a major detector upgrade, scheduled to be completed in 2024, are underway. My group is building hardware that will improve the electronic readout of the ATLAS detector. I am partnering with a group in the Electrical and Computer Engineering (ECE) Department at UT-Austin (Prof. N. Sun) to employ his work at the cutting edge of ADC research. We will support an ECE grad student for the layout of this design, and collaborate with engineering groups at Nevis Laboratory and the Electrical Engineering Department (Prof. P. Kinget) at Columbia University to integrate our ADC with gain selection circuits. We will provide this critical component of the ASIC at the challenging boundary of the analog and digital signals in the LAr calorimeter readout chain. Furthermore UT-Austin will lead the testing of this device during development and production (approximately 55,000 four-channel chips). This effort compliments my work as the deliverables manager for the LAr front-end ASICs for the US ATLAS HL-LHC project and strengthens the US commitment to that upgrade.In so doing, my group at the UT-Austin will be at the forefront of efforts to probe the structure of the universe to an unmatched degree both at the current LHC and with its future upgrades. Through both the ongoing analysis of data at the ATLAS detector and improvements to the detector itself, an answer to what lies beyond the SM may come within our grasp. My background in instrumentation and analysis allows my group to establish a singular research effort on the ATLAS experiment. In addition to answering fundamental questions about the subatomic world, the technologies developed could advance the broader scientific community and result in valuable spin-offs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

14 MeV DT Neutron Test Facility at the Sandia Ion Beam Laboratory

A recently completed LDRD project has provided a new facility at Sandia for testing effects of energetic neutrons on electronic components. 14 MeV neutrons are produced with a deuterium ion beam onto a thin-film tritide target. The goal of the project was to increase the neutron fluence to levels needed for radiation effects testing and qualification. This goal was achieved through two technical advances. First, a new multi-layer target concept was developed to reduce the rate of tritium loss from the target by isotope exchange, thereby reducing tritium usage and increasing target lifetime. The second advance was the construction of a new test chamber designed to maximize neutron flux at test locations. Together, these increased the available neutron fluence by several orders of magnitude. This new capability is being used in tests for Sandia nuclear weapon programs, evaluation of commercial parts such as highly-scaled CMOS SRAM lCs, and tests of new devices under development at Sandia such as lll-V HBTs, gallium nitride high-voltage diodes, and for fundamental studies of physical mechanisms of device failure.

36 MATERIALS SCIENCE↗

The Road to Trinity: Seventy-five years ago, Los Alamos scientists detonated the world’s first nuclear explosion

With a brilliant hot flash and a loud boom, the giant mushroom cloud with its fiery core filled the predawn sky above the New Mexico desert. The nuclear age had begun. It was 75 years ago on July 16, 1945, that Los Alamos scientists changed the world with the successful detonation of “the Gadget” – the device created to test the Fat Man implosion-type plutonium weapon before it was taken into combat. However, the road to Trinity, as the test was named by J. Robert Oppenheimer, who is thought to have been inspired by a line in a John Donne poem, was a difficult one.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Fundamental Studies in Basic Plasma Science: Experimental Investigations of Alfven Wave Damping Processes Relevant to the Solar Corona (Final Report)

Motivated by recent observations suggesting that the solar corona is heated by Alfvén wave damping at unexpectedly low heights, we performed experiments to study the basic plasma physics of Alfvén wave dissipation. Proposed coronal damping mechanisms rely on inhomogeneities in the plasma, but these theories have not been systematically studied in the laboratory. We performed experiments using the Large Plasma Device (LAPD) to test these theories.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Performance Green LEDs for Solid State Lighting

The development of white LEDs for solid state lighting (SSL) has been driven in recent years by phosphor converted LEDs (pc-LEDs). However, losses (known as Stokes’ losses) between the blue pump LED and phosphor impose a fundamental efficiency limit of ~300 lm/W on pc-LEDs. White light can also be generated from color mixed LEDs (cm-LEDs), which employ red, green, blue, and amber LEDs and have a fundamental efficiency limit of ~400 lm/W. Efficient group III-nitride materials are used for the blue LED, while efficient group III-phosphide materials are used for the red LED component. Currently, the poor efficiency of green and amber LEDs (i.e. the “green gap”) is the primary limitation for cm-LEDs. Relative to nitride-based blue LEDs, green and amber nitride LEDs suffer from lower radiative recombination rates and higher nonradiative recombination rates, which ultimately lead to reduced internal quantum efficiency (IQE). The IQE represents the portion of all electron-hole recombination events that result in a photon. In addition, long-wavelength LEDs have lower electrical efficiency (EE) compared to their blue counterparts. Addressing the green gap, would ultimately enable cm-LEDs that rival or exceed the performance of pc-LEDs. Our project focused on III-nitride materials growth and characterization, device fabrication and testing, and semiconductor physics to understand efficiency limitations of green LEDs and develop solutions to these challenges. Insights gained during our research has led to novel long-wavelength LED designs which will enable efficient solid-state lighting.

30 DIRECT ENERGY CONVERSION↗

Electrochemical Hydrogen Compression Cell Design (CRADA Final Report)

Electrochemical compression and purification is a high potential technology that is likely to outcompete mechanical compression for hydrogen end use applications. However, testing and understanding what is occurring within the cell is difficult as it is not readily accessible through experimentation. Thus, the main target is to increase performance and reduce cost of electrochemical hydrogen compression (EHC) and purification (EHP) cells and stacks using multiscale mathematical modeling informed by experiment. The models can provide physical insight into limiting processes and develop mitigation methods, which can be proven out through rapid sub-scale testing of the devices.

08 HYDROGEN↗

Handheld Raman Spectrometers: Assessment Report

In April 2022 the National Urban Security Technology Laboratory’s System Assessment and Validation for Emergency Responders program conducted an operational assessment of ten commercially available handheld Raman spectrometers. Additionally, prior to the operational assessment, the Pacific Northwest National Laboratory conducted laboratory testing of the devices, including scanning a number of samples in various containers. This report summarizes the results of the assessment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of INL Ultrasonic Thermometer

This document summarizes the development at Idaho National Laboratory of an ultrasonic thermometer. The ultrasonic thermometer is a temperature sensor capable of multi-point measurements at very high temperatures with a high level of radiation tolerance. All of the components of the ultrasonic thermometer have been improved over the course of this work. The base technology, a magnetosrictive transducer, has been shown to be highly radiation tolerant. The solenoidal coil used in the transducer has been redesigned to operate at higher frequencies that previously possible. Materials used for the acoustic waveguide (the sensing portion of the device) have been tested and ideal candidates identified. Finally, a solution to the sticking issue (diffusion bonding between the waveguide and a protective sheath) has been developed and tested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗