Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed algorithm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

SU-E-J-92: Validating Dose Uncertainty Estimates Produced by AUTODIRECT, An Automated Program to Evaluate Deformable Image Registration Accuracy

Purpose: Deformable image registration (DIR) is a powerful tool with the potential to deformably map dose from one computed-tomography (CT) image to another. Errors in the DIR, however, will produce errors in the transferred dose distribution. We have proposed a software tool, called AUTODIRECT (automated DIR evaluation of confidence tool), which predicts voxel-specific dose mapping errors on a patient-by-patient basis. This work validates the effectiveness of AUTODIRECT to predict dose mapping errors with virtual and physical phantom datasets. Methods: AUTODIRECT requires 4 inputs: moving and fixed CT images and two noise scans of a water phantom (for noise characterization). Then, AUTODIRECT uses algorithms to generate test deformations and applies them to the moving and fixed images (along with processing) to digitally create sets of test images, with known ground-truth deformations that are similar to the actual one. The clinical DIR algorithm is then applied to these test image sets (currently 4) . From these tests, AUTODIRECT generates spatial and dose uncertainty estimates for each image voxel based on a Student’s t distribution. This work compares these uncertainty estimates to the actual errors made by the Velocity Deformable Multi Pass algorithm on 11 virtual and 1 physical phantom datasets. Results: For 11 of the 12 tests, the predicted dose error distributions from AUTODIRECT are well matched to the actual error distributions within 1–6% for 10 virtual phantoms, and 9% for the physical phantom. For one of the cases though, the predictions underestimated the errors in the tail of the distribution. Conclusion: Overall, the AUTODIRECT algorithm performed well on the 12 phantom cases for Velocity and was shown to generate accurate estimates of dose warping uncertainty. AUTODIRECT is able to automatically generate patient-, organ- , and voxel-specific DIR uncertainty estimates. This ability would be useful for patient-specific DIR quality assurance.

60 APPLIED LIFE SCIENCES↗

$xy$ Position Reconstruction in DarkSide-50

The DarkSide-50 experiment seeks to directly detect dark matter in a liquid argon time projection chamber. In this dissertation, I present an algorithm of my design that determines the position of particle interactions with the liquid argon. This position reconstruction algorithm will be used by DarkSide-50 to reject backgrounds, particularly backgrounds from radioactive elements on the detector surface. The position reconstruction algorithm functions by constructing light response functions (LRFs) that map locations in the detector to the expected distribution of signal in DarkSide-50's 38 photomultiplier tubes. Accurate LRFs cannot be produced by simulations of DarkSide-50's optics because such simulations are known to be awed. Instead, this algorithm constructs LRFs using an iterative process driven by data. Initial, awed LRFs are produced using simulated events but then used to produce new LRFs from data events. Multiple generations of LRFs are created from data with each generation driven to better satisfy a known feature of the detector: the dominant argon-39 background is uniformly distributed. I also discuss a method of discriminating against surface background as an alternative to the common approach of ducialization. This method considers the di erence in goodnessof- t between the best- t reconstructed position and the best- t position at the detector's surface. I conclude by presenting results on the performance and validity of this algorithm, including some discussion of reconstruction errors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uncertainty analysis of wavelet-based feature extraction for isotope identification on NaI gamma-ray spectra

Low-resolution isotope identifiers are widely deployed for nuclear security purposes, but these detectors currently demonstrate problems in making correct identifications in many typical usage scenarios. While there are many hardware alternatives and improvements that can be made, performance on existing low resolution isotope identifiers should be able to be improved by developing new identification algorithms. We have developed a wavelet-based peak extraction algorithm and an implementation of a Bayesian classifier for automated peak-based identification. The peak extraction algorithm has been extended to compute uncertainties in the peak area calculations. To build empirical joint probability distributions of the peak areas and uncertainties, a large set of spectra were simulated in MCNP6 and processed with the wavelet-based feature extraction algorithm. Kernel density estimation was then used to create a new component of the likelihood function in the Bayesian classifier. Furthermore, identification performance is demonstrated on a variety of real low-resolution spectra, including Category I quantities of special nuclear material.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Local Phasor-Based Control of DER Inverters for Voltage Regulation on Distribution Feeders

We introduce a new control paradigm termed Phasor-Based Control (PBC) to coordinate Distributed Energy Resources (DER) for improved voltage regulation and other objectives. PBC is a multi-layer control framework where the state of the distribution grid is represented by voltage phasors, and Phasor Measurement Units (PMUs) measure the state at critical points in the distribution grid. In the PBC paradigm, a supervisory controller (S-PBC) sets phasor targets which local controllers track. In this paper, we propose a Proportional Integral (PI) implementation for the local control layer (LPBC), to regulate real and reactive power output of distributed inverters to track a voltage phasor target computed by the supervisory layer. We tune the PI controller gains offline with a genetic algorithm that yields better performance than the Ziegler-Nichols method. We benchmark the proposed L-PBC controller against droop volt-var control (DVVC) and observe improved voltage regulation in simulation on the IEEE 13 node unbalanced test feeder (IEEE 13NF). Furthermore, by means of numerical simulation we observe the response of the L-PBC controllers to small and large grid disturbances. Simulations on larger feeders, IEEE 123-node and 647-node, demonstrate challenges with tuning controllers in setups with different amounts of power-voltage coupling.

42 ENGINEERING↗

Multi-physics simulations of particle tracking in arterial geometries with a scalable moving window algorithm

In arterial systems, cancer cell trajectories determine metastatic cancer locations; similarly, particle trajectories determine drug delivery distribution. Predicting trajectories is challenging, as the dynamics are affected by local interactions with red blood cells, complex hemodynamic flow structure, and downstream factors such as stenoses or blockages. Direct simulation is not possible, as a single simulation of a large arterial domain with explicit red blood cells is currently intractable on even the largest supercomputers. To overcome this limitation, we present a multi-physics adaptive window algorithm, in which individual red blood cells are explicitly modeled in a small region of interest moving through a coupled arterial fluid domain. We describe the coupling between the window and fluid domains, including automatic insertion and deletion of explicit cells and dynamic tracking of cells of interest by the window. We show that this algorithm scales efficiently on heterogeneous architectures and enables us to perform large, highly-resolved particle-tracking simulations that would otherwise be intractable.

Herschlag, Gregory↗

An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle

Purpose: The purposes of this study were to validate a discrete spot scanning proton beam nozzle using the Monte Carlo (MC) code MCNPX and use the MC validated model to investigate the effects of a low-dose envelope, which surrounds the beam's central axis, on measurements of integral depth dose (IDD) profiles. Methods: An accurate model of the discrete spot scanning beam nozzle from The University of Texas M. D. Anderson Cancer Center (Houston, Texas) was developed on the basis of blueprints provided by the manufacturer of the nozzle. The authors performed simulations of single proton pencil beams of various energies using the standard multiple Coulomb scattering (MCS) algorithm within the MCNPX source code and a new MCS algorithm, which was implemented in the MCNPX source code. The MC models were validated by comparing calculated in-air and in-water lateral profiles and percentage depth dose profiles for single pencil beams with their corresponding measured values. The models were then further tested by comparing the calculated and measured three-dimensional (3-D) dose distributions. Finally, an IDD profile was calculated with different scoring radii to determine the limitations on the use of commercially available plane-parallel ionization chambers to measure IDD. Results: The distance to agreement, defined as the distance between the nearest positions of two equivalent distributions with the same value of dose, between measured and simulated ranges was within 0.13 cm for both MCS algorithms. For low and intermediate pencil beam energies, the MC simulations using the standard MCS algorithm were in better agreement with measurements. Conversely, the new MCS algorithm produced better results for high-energy single pencil beams. The IDD profile calculated with cylindrical tallies with an area equivalent to the area of the largest commercially available ionization chamber showed up to 7.8% underestimation of the integral dose in certain depths of the IDD profile. Conclusions: The authors conclude that a combination of MCS algorithms is required to accurately reproduce experimental data of single pencil beams and 3-D dose distributions for the scanning beam nozzle. In addition, the MC simulations showed that because of the low-dose envelope, ionization chambers with radii as large as 4.08 cm are insufficient to accurately measure IDD profiles for a 221.8 MeV pencil beam in the scanning beam nozzle.

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-07: Three-Dimensional Dose Reconstruction in the Presence of Inhomogeneities Using Fast EPID-Based Back-Projection Method

Purpose: Three-dimensional dose verification can detect errors introduced by the treatment planning system (TPS) or differences between planned and delivered dose distribution during the treatment. The aim of the study is to extend a previous in-house developed three-dimensional dose reconstructed model in homogeneous phantom to situtions in which tissue inhomogeneities are present. Methods: The method was based on the portal grey images from an electronic portal imaging device (EPID) and the relationship between beamlets and grey-scoring voxels at the position of the EPID. The relationship was expressed in the form of grey response matrix that was quantified using thickness-dependence scatter kernels determined by series of experiments. From the portal grey-value distribution information measured by the EPID the two-dimensional incident fluence distribution was reconstructed based on the grey response matrix using a fast iterative algorithm. The accuracy of this approach was verified using a four-field intensity-modulated radiotherapy (IMRT) plan for the treatment of lung cancer in anthopomorphic phantom. Each field had between twenty and twenty-eight segments and was evaluated by comparing the reconstructed dose distribution with the measured dose. Results: The gamma-evaluation method was used with various evaluation criteria of dose difference and distance-to-agreement: 3%/3mm and 2%/2 mm. The dose comparison for all irradiated fields showed a pass rate of 100% with the criterion of 3%/3mm, and a pass rate of higher than 92% with the criterion of 2%/2mm. Conclusion: Our experimental results demonstrate that our method is capable of accurately reconstructing three-dimensional dose distribution in the presence of inhomogeneities. Using the method, the combined planning and treatment delivery process is verified, offing an easy-to-use tool for the verification of complex treatments.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-09: A Random Walk Model Algorithm for Proton Dose Calculation

Purpose: To develop a random walk model algorithm for calculating proton dose with balanced computation burden and accuracy. Methods: Random walk (RW) model is sometimes referred to as a density Monte Carlo (MC) simulation. In MC proton dose calculation, the use of Gaussian angular distribution of protons due to multiple Coulomb scatter (MCS) is convenient, but in RW the use of Gaussian angular distribution requires an extremely large computation and memory. Thus, our RW model adopts spatial distribution from the angular one to accelerate the computation and to decrease the memory usage. From the physics and comparison with the MC simulations, we have determined and analytically expressed those critical variables affecting the dose accuracy in our RW model. Results: Besides those variables such as MCS, stopping power, energy spectrum after energy absorption etc., which have been extensively discussed in literature, the following variables were found to be critical in our RW model: (1) inverse squared law that can significantly reduce the computation burden and memory, (2) non-Gaussian spatial distribution after MCS, and (3) the mean direction of scatters at each voxel. In comparison to MC results, taken as reference, for a water phantom irradiated by mono-energetic proton beams from 75 MeV to 221.28 MeV, the gamma test pass rate was 100% for the 2%/2mm/10% criterion. For a highly heterogeneous phantom consisting of water embedded by a 10 cm cortical bone and a 10 cm lung in the Bragg peak region of the proton beam, the gamma test pass rate was greater than 98% for the 3%/3mm/10% criterion. Conclusion: We have determined key variables in our RW model for proton dose calculation. Compared with commercial pencil beam algorithms, our RW model much improves the dose accuracy in heterogeneous regions, and is about 10 times faster than MC simulations.

60 APPLIED LIFE SCIENCES↗

BAYESIAN NOISE ESTIMATION FOR NON-IDEAL COSMIC MICROWAVE BACKGROUND EXPERIMENTS

We describe a Bayesian framework for estimating the time-domain noise covariance of cosmic microwave background (CMB) observations, typically parameterized in terms of a 1/f frequency profile. This framework is based on the Gibbs sampling algorithm, which allows for exact marginalization over nuisance parameters through conditional probability distributions. In this paper, we implement support for gaps in the data streams and marginalization over fixed time-domain templates, and also outline how to marginalize over confusion from CMB fluctuations, which may be important for high signal-to-noise experiments. As a by-product of the method, we obtain proper constrained realizations, which themselves can be useful for map making. To validate the algorithm, we demonstrate that the reconstructed noise parameters and corresponding uncertainties are unbiased using simulated data. The CPU time required to process a single data stream of 100,000 samples with 1000 samples removed by gaps is 3 s if only the maximum posterior parameters are required, and 21 s if one also wants to obtain the corresponding uncertainties by Gibbs sampling.

79 ASTRONOMY AND ASTROPHYSICS↗

MR-OPERA: A Multicenter/Multivendor Validation of Magnetic Resonance Imaging–Only Prostate Treatment Planning Using Synthetic Computed Tomography Images

Purpose: To validate the dosimetric accuracy and clinical robustness of a commercially available software for magnetic resonance (MR) to synthetic computed tomography (sCT) conversion, in an MR imaging–only workflow for 170 prostate cancer patients. Methods and Materials: The 4 participating centers had MriPlanner (Spectronic Medical), an atlas-based sCT generation software, installed as a cloud-based service. A T2-weighted MR sequence, covering the body contour, was added to the clinical protocol. The MR images were sent from the MR scanner workstation to the MriPlanner platform. The sCT was automatically returned to the treatment planning system. Four MR scanners and 2 magnetic field strengths were included in the study. For each patient, a CT-treatment plan was created and approved according to clinical practice. The sCT was rigidly registered to the CT, and the clinical treatment plan was recalculated on the sCT. The dose distributions from the CT plan and the sCT plan were compared according to a set of dose-volume histogram parameters and gamma evaluation. Treatment techniques included volumetric modulated arc therapy, intensity modulated radiation therapy, and conventional treatment using 2 treatment planning systems and different dose calculation algorithms. Results: The overall (multicenter/multivendor) mean dose differences between sCT and CT dose distributions were below 0.3% for all evaluated organs and targets. Gamma evaluation showed a mean pass rate of 99.12% (0.63%, 1 SD) in the complete body volume and 99.97% (0.13%, 1 SD) in the planning target volume using a 2%/2-mm global gamma criteria. Conclusions: Results of the study show that the sCT conversion method can be used clinically, with minimal differences between sCT and CT dose distributions for target and relevant organs at risk. The small differences seen are consistent between centers, indicating that an MR imaging–only workflow using MriPlanner is robust for a variety of field strengths, vendors, and treatment techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A MIMO AAA Agorithm for Frequency Dependent Line Modeling

Modeling of power distribution system components that are valid for a wide range of frequencies are crucial for highly accurate modeling of electromagnetic transient (EMT) events. This has recently become of interest due to the improvements needed for the resilient operation of distribution systems. Vector fitting (VF) is a very popular and commonly used algorithm for wide band representations of power system components in EMT simulations. In this research, we present a new multi-input rational approximation algorithm (MIAAA) and illustrate its advantages with respect to VF using examples of approximations of admittance matrices discussed in the literature. We show that MIAAA not only outperforms VF in terms of achieving better accuracy using lesser number of poles, but also has no numerical issues achieving convergence. In contrast to VF, MIAAA is not sensitive to the location of input sample points and it does not require good estimates for the location of the desired approximation poles. The novelty of this research work is the use of recent mathematical results to solve existing challenges in distribution system modeling and to develop rational approximations for power system models that intend to be optimal in terms of accuracy and performance.

AAA algorithm↗

Secure Distributed State Estimation for Networked Microgrids

Distributed state estimation (DSE) allows networked microgrids to achieve global state awareness with conservation of local information privacy by peer-to-peer message exchange implemented with Internet of Things protocols over heterogeneous communications. This paper presents a secure DSE (SDSE) method for networked microgrids to enhance system resiliency by addressing false data injection threat in distributed microgrid agent nodes. Here, the designated SDSE applies a trust-based diffusion algorithm using adaptive combination policy, which allows agents to adapt their combination coefficients to exclude misbehaving nodes from the network. The results demonstrate that proposed SDSE algorithm addresses emerging data integrity and security problems in critical energy delivery infrastructure and SCADA environment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault diagnosis and fault tolerant control for T-S fuzzy stochastic distribution systems subject to sensor and actuator faults

The problem of fault diagnosis (FD) and fault tolerant control (FTC) for a class of Takagi-Sugeno (T-S) fuzzy stochastic distribution control (SDC) systems subject to sensor and actuator faults is discussed in this paper. First, fuzzy logic models are used to approximate the output probability density function (PDF). Next, an adaptive augmented state/fault diagnosis observer is proposed to estimate the system state, sensor and the actuator faults simultaneously. New expected weights based on the sensor fault estimation information and a PI-type fuzzy feedback fault tolerant (FT) controller are designed to compensate the effect of sensor fault and actuator fault simultaneously. When the sensor fault occurs, the expected objective is redesigned to compensate the sensor fault. Meanwhile, the PI controller can compensate the effect of actuator fault, and the output PDF of the system can still track the desired PDF after the fault occurs. Finally, an example of quality distribution control in chemical reaction process is given to confirm the effectiveness of the algorithm.

42 ENGINEERING↗

SU-E-T-31: A Fast Finite Size Pencil Beam (FSPB) Convolution Algorithm for a New Co-60 Arc Therapy Machine

Purpose: Present a fast Finite Size Pencil Beam (FSPB) convolution algorithm for a new Co-60 arc therapy machine. The FSPB algorithm accounts for (i) strong angular divergence (short SAD), (ii) heterogeneity effect for primary attenuation, and (iii) source energy spectrum. Methods: The FSPB algorithm is based on a 0.5×0.5-cm2 dose kernel calculated using the GEPTS (Gamma Electron and Positron Transport System) Monte Carlo code. The dose kernel is tabulated using a thin XYZ mesh (0.1 mm steps in lateral directions) for radius less than 1 cm and using an RZ mesh (with varying steps) for larger radial distance. To account for SSD effect, 11 dose kernels with SSDs varying between 30 cm to 80 cm are calculated. Maynord factor and “lateral stretching” are applied to account for differences between closest and actual SSD. Appropriate rotations and second order interpolation are used to calculate the dose from a given beamlet to a point. Results: Accuracy: Dose distributions in water with 80 cm SSD are calculated using the new FSPB convolution algorithm and full Monte Carlo simulation (gold standard). Figs 1–4 show excellent agreements between FSPB and Monte Carlo calculations for different field sizes and at different depths. The dose distribution for a prostate case is calculated using FSPB (Fig.5). Sixty conformal beams with rectum blocking are assumed. Figs 6–8 show the comparison with Monte Carlo simulation based on the same beam apertures. The excellent agreement demonstrates the accuracy of the new algorithm in handling SSD variation, oblique incidence, and scatter contribution.Speed: The FSPB convolution algorithm calculates 28 million dose points per second using a single 2.2-GHz CPU. The present algorithm is seven times faster than a similar algorithm from Gu et al. (Phys. Med. Biol. 54, 2009, 6287–6297). Conclusion: A fast and accurate FSPB convolution algorithm was developed and benchmarked.

60 APPLIED LIFE SCIENCES↗

THE DENSITY FIELD OF THE 10k zCOSMOS GALAXIES

We use the current sample of approx10,000 zCOSMOS spectra of sources selected with I{sub AB} < 22.5 to define the density field out to z approx 1, with much greater resolution in the radial dimension than has been possible with either photometric redshifts or weak lensing. We present the new algorithm that we have developed (ZADE) to incorporate objects not yet observed spectroscopically by modifying their photometric redshift probability distributions using the spectroscopic redshifts of nearby galaxies. We present a number of tests on mock catalogs used to justify this approach. The ZADE algorithm allows us to probe a broader range of galaxy environments and reduce the Poisson noise in the density field. The reconstructed overdensity field of the 10k zCOSMOS galaxies consists of cluster-like patterns surrounded by void-like regions, extending up to z approx 1. Some of these structures are very large, spanning the approx50 h {sup -1} Mpc transverse direction of the COSMOS field and extending up to DELTAz approx 0.05 in redshift. We present the three-dimensional overdensity maps and compare the reconstructed overdensity field to the independently identified virialized groups of galaxies and clusters detected in the visible and in X-rays. The distribution of the overdense structures is in general well traced by these virialized structures. A comparison of the large-scale structures in the zCOSMOS data and in the mock catalogs reveals an excellent agreement between the fractions of the volume enclosed in structures of all sizes above a given overdensity between the data and the mocks in 0.2 < z < 1, although in the data these overdense regions are in generally larger contiguous structures.

79 ASTRONOMY AND ASTROPHYSICS↗

A machine learning photon detection algorithm for coherent x-ray ultrafast fluctuation analysis

X-ray free electron laser experiments have brought unique capabilities and opened new directions in research, such as creating new states of matter or directly measuring atomic motion. One such area is the ability to use finely spaced sets of coherent x-ray pulses to be compared after scattering from a dynamic system at different times. This enables the study of fluctuations in many-body quantum systems at the level of the ultrafast pulse durations, but this method has been limited to a select number of examples and required complex and advanced analytical tools. By applying a new methodology to this problem, we have made qualitative advances in three separate areas that will likely also find application to new fields. As compared to the “droplet-type” models, which typically are used to estimate the photon distributions on pixelated detectors to obtain the coherent x-ray speckle patterns, our algorithm achieves an order of magnitude speedup on CPU hardware and two orders of magnitude improvement on GPU hardware. We also find that it retains accuracy in low-contrast conditions, which is the typical regime for many experiments in structural dynamics. Finally, it can predict photon distributions in high average-intensity applications, a regime which up until now has not been accessible. Our artificial intelligence-assisted algorithm will enable a wider adoption of x-ray coherence spectroscopies, by both automating previously challenging analyses and enabling new experiments that were not otherwise feasible without the developments described in this work.

47 OTHER INSTRUMENTATION↗

VisIO: enabling interactive visualization of ultra-scale, time-series data via high-bandwidth distributed I/O systems

Petascale simulations compute at resolutions ranging into billions of cells and write terabytes of data for visualization and analysis. Interactive visuaUzation of this time series is a desired step before starting a new run. The I/O subsystem and associated network often are a significant impediment to interactive visualization of time-varying data; as they are not configured or provisioned to provide necessary I/O read rates. In this paper, we propose a new I/O library for visualization applications: VisIO. Visualization applications commonly use N-to-N reads within their parallel enabled readers which provides an incentive for a shared-nothing approach to I/O, similar to other data-intensive approaches such as Hadoop. However, unlike other data-intensive applications, visualization requires: (1) interactive performance for large data volumes, (2) compatibility with MPI and POSIX file system semantics for compatibility with existing infrastructure, and (3) use of existing file formats and their stipulated data partitioning rules. VisIO, provides a mechanism for using a non-POSIX distributed file system to provide linear scaling of 110 bandwidth. In addition, we introduce a novel scheduling algorithm that helps to co-locate visualization processes on nodes with the requested data. Testing using VisIO integrated into Para View was conducted using the Hadoop Distributed File System (HDFS) on TACC's Longhorn cluster. A representative dataset, VPIC, across 128 nodes showed a 64.4% read performance improvement compared to the provided Lustre installation. Also tested, was a dataset representing a global ocean salinity simulation that showed a 51.4% improvement in read performance over Lustre when using our VisIO system. VisIO, provides powerful high-performance I/O services to visualization applications, allowing for interactive performance with ultra-scale, time-series data.

97 MATHEMATICS AND COMPUTING↗

Network reconfiguration and distributed energy resource scheduling for improved distribution system resilience

Electric utility companies work to restore as much load as possible after power outages caused by extreme weather events. In this paper, an outage management strategy is proposed to enhance distribution system resilience through network reconfiguration and distributed energy resources (DERs) scheduling. After a line fault, the proposed algorithm can identify radial network topology based on the rank of the incidence matrix. The reconfiguration is implemented by switching tie lines and sectionalizing lines. With the new network topology, an optimal DER scheduling problem is solved to minimize the accumulative cost for dispatchable DER operation and load reduction. Finally, the optimal topology that minimizes the accumulative cost is selected from all radial topologies. The computational workload is relatively low because only linear programming needs to be solved. Using the case studies of the IEEE 69-bus and IEEE 123-bus systems, we consider the worst-case scenarios in which faults occur in the upstream feeder. The simulation results demonstrate that the proposed strategy allows for a relatively high percentage of the load to remain in service after line faults. Furthermore, compared with microgrid-formation approaches, the proposed strategy has advantages when applied to the distribution systems with several normally-open tie lines and low DER penetration.

42 ENGINEERING↗