Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Correlations between conduction electrons in dense plasmas

Most treatments of electron-electron correlations in dense plasmas either ignore them entirely (random phase approximation) or neglect the role of ions (jellium approximation). In this work, we go beyond both these approximations to derive a formula for the electron-electron static structure factor which properly accounts for the contributions of both ionic structure and quantum-mechanical dynamic response in the electrons. The result can be viewed as a natural extension of the quantum Ornstein-Zernike theory of ionic and electronic correlations, and it is suitable for dense plasmas in which the ions are classical and the conduction electrons are quantum-mechanical. Here, the corresponding electron-electron pair distribution functions are compared with the results of path integral Monte Carlo simulations, showing good agreement whenever no strong electron resonance states are present. We construct approximate potentials of mean force which describe the effective screened interaction between electrons. Significant deviations from Debye-Hückel screening are present at temperatures and densities relevant to high-energy density experiments involving warm and hot dense plasmas. The presence of correlations between conduction electrons is likely to influence the electron-electron contribution to the electrical and thermal conductivity. It is expected that excitation processes involving the conduction electrons (e.g., free-free absorption) will also be affected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of Varian TrueBeam electron phase–spaces for Monte Carlo simulation of MLC-shaped fields

Purpose: This work evaluates Varian’s electron phase–space sources for Monte Carlo simulation of the TrueBeam for modulated electron radiation therapy (MERT) and combined, modulated photon and electron radiation therapy (MPERT) where fields are shaped by the photon multileaf collimator (MLC) and delivered at 70 cm SSD. Methods: Monte Carlo simulations performed with EGSnrc-based BEAMnrc/DOSXYZnrc and PENELOPE-based PRIMO are compared against diode measurements for 5 × 5, 10 × 10, and 20 × 20 cm{sup 2} MLC-shaped fields delivered with 6, 12, and 20 MeV electrons at 70 cm SSD (jaws set to 40 × 40 cm{sup 2}). Depth dose curves and profiles are examined. In addition, EGSnrc-based simulations of relative output as a function of MLC-field size and jaw-position are compared against ion chamber measurements for MLC-shaped fields between 3 × 3 and 25 × 25 cm{sup 2} and jaw positions that range from the MLC-field size to 40 × 40 cm{sup 2}. Results: Percent depth dose curves generated by BEAMnrc/DOSXYZnrc and PRIMO agree with measurement within 2%, 2 mm except for PRIMO’s 12 MeV, 20 × 20 cm{sup 2} field where 90% of dose points agree within 2%, 2 mm. Without the distance to agreement, differences between measurement and simulation are as large as 7.3%. Characterization of simulated dose parameters such as FWHM, penumbra width and depths of 90%, 80%, 50%, and 20% dose agree within 2 mm of measurement for all fields except for the FWHM of the 6 MeV, 20 × 20 cm{sup 2} field which falls within 2 mm distance to agreement. Differences between simulation and measurement exist in the profile shoulders and penumbra tails, in particular for 10 × 10 and 20 × 20 cm{sup 2} fields of 20 MeV electrons, where both sets of simulated data fall short of measurement by as much as 3.5%. BEAMnrc/DOSXYZnrc simulated outputs agree with measurement within 2.3% except for 6 MeV MLC-shaped fields. Discrepancies here are as great as 5.5%. Conclusions: TrueBeam electron phase–spaces available from Varian have been implemented in two distinct Monte Carlo simulation packages to produce dose distributions and outputs that largely reflect measurement. Differences exist in the profile shoulders and penumbra tails for the 20 MeV phase–space off-axis and in the outputs for the 6 MeV phase–space.

07 ISOTOPE AND RADIATION SOURCES↗

Inverse compton light source: a compact design proposal

In the last decade, there has been an increasing demand for a compact Inverse Compton Light Source (ICLS) which is capable of producing high-quality X-rays by colliding an electron beam and a high-quality laser. It is only in recent years when both SRF and laser technology have advanced enough that compact sources can approach the quality found at large installations such as the Advanced Photon Source at Argonne National Laboratory. Previously, X-ray sources were either high flux and brilliance at a large facility or many orders of magnitude lesser when produced by a bremsstrahlung source. A recent compact source was constructed by Lyncean Technologies using a storage ring to produce the electron beam used to scatter the incident laser beam. By instead using a linear accelerator system for the electron beam, a significant increase in X-ray beam quality is possible, though even subsequent designs also featuring a storage ring offer improvement. Preceding the linear accelerator with an SRF reentrant gun allows for an extremely small transverse emittance, increasing the brilliance of the resulting X-ray source. In order to achieve sufficiently small emittances, optimization was done regarding both the geometry of the gun and the initial electron bunch distribution produced off the cathode. Using double-spoke SRF cavities to comprise the linear accelerator allows for an electron beam of reasonable size to be focused at the interaction point, while preserving the low emittance that was generated by the gun. An aggressive final focusing section following the electron beam's exit from the accelerator produces the small spot size at the interaction point which results in an X-ray beam of high flux and brilliance. Taking all of these advancements together, a world class compact X-ray source has been designed. It is anticipated that this source would far outperform the conventional bremsstrahlung and many other compact ICLSs, while coming closer to performing at the levels found at large facilities than ever before. The design process, including the development between subsequent iterations, is presented here in detail, with the simulation results for this groundbreaking X-ray source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hot plasma associated with a coronal mass ejection

We analyze coordinated observations from the EUV Imaging Spectrometer (EIS) and X-Ray Telescope (XRT) on board Hinode of an X-ray Plasma Ejection (XPE) that occurred during the coronal mass ejection (CME) event of 2008 April 9. The XPE was trailing the CME core from behind, following the same trajectory, and could be identified both in EIS and XRT observations. Using the EIS spectrometer, we have determined the XPE plasma parameters, measuring the electron density, thermal distribution, and elemental composition. We have found that the XPE composition and electron density were very similar to those of the pre-event active region plasma. The XPE temperature was higher, and its thermal distribution peaked at around 3 MK; also, typical flare lines were absent from EIS spectra, indicating that any XPE component with temperatures in excess of 5 MK was likely either faint or absent. We used XRT data to investigate the presence of hotter plasma components in the XPE that could have gone undetected by EIS and found that—if at all present—these components have small emission measure values and their temperature is in the 8-12.5 MK range. The very hot plasma found in earlier XPE observations obtained by Yohkoh seems to be largely absent in this CME, although plasma ionization timescales may lead to non-equilibrium ionization effects that could make bright lines from ions formed in a 10 MK plasma not detectable by EIS. Our results supersede the XPE findings of Landi et al., who studied the same event with older response functions for the XRT Al-poly filter; the differences in the results stress the importance of using accurate filter response functions.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of the Complete Spin Density Distribution in 13 C-Labeled Protein-Bound Radical Intermediates Using Advanced 2D Electron Paramagnetic Resonance Spectroscopy and Density Functional Theory

Determining the complete electron spin density distribution for protein-bound radicals, even with advanced pulsed electron paramagnetic resonance (EPR) methods, is a formidable task. Here we present a strategy to overcome this problem combining multifrequency HYSCORE and ENDOR measurements on site-specifically 13 C-labeled samples with DFT calculations on model systems. As a demonstration of this approach, pulsed EPR experiments are performed on the primary Q A and secondary Q B ubisemiquinones of the photosynthetic reaction center from Rhodobacter sphaeroides 13C-labeled at the ring and tail positions. Despite the large number of nuclei interacting with the unpaired electron in these samples, two-dimensional X- and Q-band HYSCORE and orientation selective Q-band ENDOR resolve and allow for a characterization of the eight expected 13 C resonances from significantly different hyperfine tensors for both semiquinones. From these results we construct, for the first time, the most complete experimentally determined maps of the s- and p π -orbital spin density distributions for any protein organic cofactor radical to date. This work lays a foundation for understanding the relationship between the electronic structure of semiquinones and their functional properties, and introduces new techniques for mapping out the spin density distribution that are readily applicable to other systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the W Boson Mass with the D0 Run II Detector using the Electron P(T) Spectrum

This thesis is a description of the measurement of the W boson mass using the D0 Run II detector with 770 pb -1 of p$\bar{p}$ collision data. These collisions were produced by the Tevatron at √s = 1.96 TeV between 2002 and 2006. We use a sample of W → ev and Z → ee decays to determine the W boson mass with the transverse momentum distribution of the electron and the transverse mass distribution of the boson. We measure M W = 80340 ± 37 (stat.) ± 26 (sys. theo.) ± 51 (sys. exp.) MeV = 80340 ± 68 MeV with the transverse momentum distribution of the electron and M W = 80361 ± 28 (stat.) ± 17 (sys. theo.) ± 51 (sys. exp.) MeV = 80361 ± 61 MeV with the transverse mass distribution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compton profile of VO 2 across the metal-insulator transition: Evidence of a non-Fermi liquid metal

Many-body diffusion Monte Carlo is used to obtain the first-principles momentum distribution and Compton profile of vanadium dioxide. Our results for the Compton profile are in good agreement with the experimental values, and we show that good qualitative agreement in the scaled Compton profile difference across the monoclinic to rutile phase transition depends on an accurate description of electron correlation. The electron momentum distribution enables new insights into the metal-insulator phase transition. For example, the probability for electron scattering in the proximity of the Fermi surface (forward scattering) is suppressed in the vanadium chain direction (rutile c axis) but enhanced in perpendicular directions. However, along the c axis we observe an increase at ~2k F in the momentum distribution, which is characteristic for Friedel oscillations (backscattering). Our analysis of the momentum distribution supports experimentally observed anisotropies and provides an explanation for the anomalously low electronic thermal conductivity observed recently in the metallic phase. Furthermore, our results indicate non-Fermi liquid behavior as well as quasi-one-dimensional Friedel oscillations in the metallic rutile phase, which is reminiscent of a Tomanaga-Luttinger liquid with impurities.

36 MATERIALS SCIENCE↗

High density plasmas and new diagnostics: An overview (invited)

One of the limiting factors for the full understanding of Electron Cyclotron Resonance Ion Sources (ECRISs) fundamental mechanisms consists of few types of diagnostic tools so far available for such compact machines. Microwave-to-plasma coupling optimisation, new methods of density overboost provided by plasma wave generation, and magnetostatic field tailoring for generating a proper electron energy distribution function, suitable for optimal ion beams formation, require diagnostic tools spanning across the entire electromagnetic spectrum from microwave interferometry to X-ray spectroscopy; these methods are going to be implemented including high resolution and spatially resolved X-ray spectroscopy made by quasi-optical methods (pin-hole cameras). The ion confinement optimisation also requires a complete control of cold electrons displacement, which can be performed by optical emission spectroscopy. Several diagnostic tools have been recently developed at INFN-LNS, including “volume-integrated” X-ray spectroscopy in low energy domain (2-30 keV, by using silicon drift detectors) or high energy regime (>30 keV, by using high purity germanium detectors). For the direct detection of the spatially resolved spectral distribution of X-rays produced by the electronic motion, a “pin-hole camera” has been developed also taking profit from previous experiences in the ECRIS field. The paper will give an overview of INFN-LNS strategy in terms of new microwave-to-plasma coupling schemes and advanced diagnostics supporting the design of new ion sources and for optimizing the performances of the existing ones, with the goal of a microwave-absorption oriented design of future machines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Potential and electron density calculated for freely expanding plasma by an electron beam

This paper investigates the radial distributions of potential and electron density in free expansion plasma induced by an electron beam irradiating on the plate. The region of plasma production is assumed to be cylindrical, and the plasma expansion is assumed to be from a cylindrical source. Therefore, the one-dimensional model in cylindrical coordinates is employed in order to analyze the radial distributions of the potential and electron density. The Runge-Kutta method and the perturbation method are utilized in order to obtain the numerical and approximate solutions, respectively. The results reveal that the decrease in the initial ion energy makes most of the ions gather near the plasma production region and reduces the distribution of the average positive potential, electron, and ion density along the radial direction. The oscillation of steady-state plasma along the radial direction is also presented in this paper. The ions induce a larger amplitude of oscillation along the radial direction than do electrons because the electrons oscillate around slowly moving ions due to a far smaller electron mass than ion mass. The radial distributions of the positive potential and electron density predicted from this study are compared with the available experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of the non-planar morphology of pre-patterned substrates on the structural and electronic properties of embedded site-controlled InAs quantum dots

We present an experimental and theoretical analysis of the influence of a surface nanopattern on the properties of embedded InAs/GaAs quantum dots (QD). In particular, we analyze QDs grown on nanoimprint lithography (NIL) patterned grooves and investigate the influence of the non-planar surface morphology on the size, shape, strain distribution, and electronic structure of the embedded QDs. We show that the height reduction of InAs QDs during GaAs capping is significantly less pronounced for the QDs grown on the pattern than for the self-assembled QDs. Furthermore, the pattern has a strong impact on the strain and composition profile within the QD. The experimentally observed strain distribution was successfully reproduced with a three-dimensional model assuming an inverse-cone type composition gradient. Moreover, we show that the specific morphology of the QDs grown in the grooves gives rise to an increase of the vertically polarized photoluminescence emission which was explained by employing 8-band k.p calculations. Our findings emphasize that the surface curvature of the pattern not only determines the nucleation sites of the QDs but also has a strong impact on their morphological properties including shape, size, composition profile, and strain distribution. These properties are strongly cross-correlated and determine the electronic and optical characteristics of the QDs.

36 MATERIALS SCIENCE↗

Comparison of equilibrium ohmic and nonequilibrium swarm models for monitoring conduction electron evolution in high-altitude EMP calculations

Here, atmospheric electromagnetic pulse (EMP) events are important physical phenomena that occur through both man-made and natural processes. Radiation-induced currents and voltages in EMP can couple with electrical systems, such as those found in satellites, and cause significant damage. Due to the disruptive nature of EMP, it is important to accurately predict EMP evolution and propagation with computational models. CHAP-LA (Compton High Altitude Pulse-Los Alamos) is a state-of-the-art EMP code that solves Maxwell inline images equations for gamma source-induced electromagnetic fields in the atmosphere. In EMP, low-energy, conduction electrons constitute a conduction current that limits the EMP by opposing the Compton current. CHAP-LA calculates the conduction current using an equilibrium ohmic model. The equilibrium model works well at low altitudes, where the electron energy equilibration time is short compared to the rise time or duration of the EMP. At high altitudes, the equilibration time increases beyond the EMP rise time and the predicted equilibrium ionization rate becomes very large. The ohmic model predicts an unphysically large production of conduction electrons which prematurely and abruptly shorts the EMP in the simulation code. An electron swarm model, which implicitly accounts for the time evolution of the conduction electron energy distribution, can be used to overcome the limitations exhibited by the equilibrium ohmic model. We have developed and validated an electron swarm model previously in Pusateri et al. (2015). Here we demonstrate EMP damping behavior caused by the ohmic model at high altitudes and show improvements on high-altitude, upward EMP modeling obtained by integrating a swarm model into CHAP-LA.

54 ENVIRONMENTAL SCIENCES↗

NuGraph2 with context-aware inputs: physics-inspired improvements in semantic segmentation

Graph neural networks have recently shown strong promise for event reconstruction tasks in Liquid Argon Time Projection Chambers, yet their performance remains limited for underrepresented classes of particles, such as Michel electrons. In this work, we investigate physics-informed strategies to improve semantic segmentation within the NuGraph2 architecture. We explore three complementary approaches: (i) enriching the input representation with context-aware features derived from detector geometry and track continuity, (ii) introducing auxiliary decoders to capture class-level correlations, and (iii) incorporating energy-based regularization terms motivated by Michel electron energy distributions. Experiments on MicroBooNE public datasets show that physics-inspired feature augmentation yields the largest gains, particularly boosting Michel electron precision and recall by disentangling overlapping latent space regions. In contrast, auxiliary decoders and energy-regularization terms provided limited improvements, partly due to the hit-level nature of NuGraph2, which lacks explicit particle- or event-level representations. Our findings highlight that embedding physics context directly into node-level inputs is more effective than imposing task-specific auxiliary losses, and suggest that future hierarchical architectures such as NuGraph3, with explicit particle- and event-level reasoning, will provide a more natural setting for advanced decoders and physics-based regularization. The code for this work is publicly available on Github at https://github.com/vitorgrizzi/nugraph_phys/tree/main_phys.

Other Experiments↗

Propagation of Gaussian laser beam in cold plasma of Drude model

The propagation characters of Gaussian laser beam in plasmas of Drude model have been investigated by complex eikonal function assumption. The dielectric constant of Drude model is representative and applicable in describing the cold unmagnetized plasmas. The dynamics of ponderomotive nonlinearity, spatial diffraction, and collision attenuation is considered. The derived coupling equations determine the variations of laser beam and irradiation attenuation. The modified laser beam-width parameter F, the dimensionless axis irradiation intensity I, and the spatial electron density distribution n/n{sub 0} have been studied in connection with collision frequency, initial laser intensity and beam-width, and electron temperature of plasma. The variations of laser beam and plasma density due to different selections of parameters are reasonably explained, and results indicate the feasible modification of the propagating characters of laser beam in plasmas, which possesses significance to fast ignition, extended propagation, and other applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Communication: Reduced density matrices in molecular systems: Grand-canonical electron states

Grand-canonical like descriptions of many electron atomic and molecular open systems which are characterized by a non-integer number of electrons are presented. Their associated reduced density matrices (RDMs) are obtained by introducing the contracting mapping for this type of distributions. It is shown that there is loss of information when connecting RDMs of different order by partial contractions. The energy convexity property of these systems simplifies the description. Consequently, this formulation opens the possibility to a new look for chemical descriptors such as chemical potential and reactivity among others. Examples are presented to discuss the theoretical aspects of this work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental results of superimposing 9.9 GHz extraordinary mode microwaves on 2.45 GHz ECRIS plasma

Efficient production of multicharged ions has been investigated on the tandem-type ECRIS in Osaka University. According to the consideration of the accessibility conditions of microwaves to resonance and cutoff regions, it was suggested that the upper hybrid resonance (UHR) heating contributed to enhancement of ion beam intensity. In order to enhance multicharged ion beams efficiently, injecting higher frequency microwave with extraordinary (X-mode) toward UHR region has been tried. In this study, 2.45 GHz frequency microwaves are used for conventional ECR discharge, and 9.9 GHz frequency microwaves with X-mode are superimposed for UHR heating. The effects of additive microwave injection are investigated experimentally in terms of plasma parameters and electron energy distribution function (EEDF) measured by Langmuir probe and ion beam current. As the results show, it is confirmed that the electrons in the high energy region are affected by 9.9 GHz X-mode microwave injection from the detailed analysis of EEDF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delineation of the impact on temporal behaviors of off-axis photoemission in an ultrafast electron microscope

Efforts to push the spatiotemporal imaging-resolution limits of femtosecond laser-driven ultrafast electron microscopes (UEMs) to the combined angstrom–fs range will benefit from stable sources capable of generating high bunch charges. Recent demonstrations of unconventional off-axis photoemitting geometries are promising, but connections to the observed onset of structural dynamics are yet to be established. Here we use the in-situ photoexcitation of coherent phonons to quantify the relative time-of-flight (r-TOF) of photoelectron packets generated from the Ni Wehnelt aperture and from a Ta cathode set-back from the aperture plane. We further support the UEM experiments with particle-tracing simulations of the precise electron-gun architecture and photoemitting geometries. In this way, we measure discernible shifts in electron-packet TOF of tens of picoseconds for the two photoemitting surfaces. Furthermore, these shifts arise from the impact that the Wehnelt-aperture off-axis orientation has on the electron-momentum distribution, which modifies both the collection efficiency and the temporal-packet distribution relative to on-axis emission. Future needs are identified; we expect this and other developments in UEM electron-gun configuration to expand the range of material phenomena that can be directly imaged on scales commensurate with fundamental structural dynamics.

47 OTHER INSTRUMENTATION↗

Probing the fields in an ultracold plasma by microwave spectroscopy

By observing the Stark shift of the Rb 42s{sub 1/2}-42p{sub 1/2} microwave transition we have measured the electric fields in an ultracold plasma formed by photoionizing Rb atoms in a magneto-optical trap. Using this approach and a model of the electron charge distribution we have been able to measure both the microscopic fields due to nearest-neighbor ions and the macroscopic fields due to the charge imbalance in the plasma.

74 ATOMIC AND MOLECULAR PHYSICS↗