Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Relative role of motion and PSF compensation in whole-body oncologic PET-MR imaging

Purpose: Respiratory motion and partial-volume effects are the two main sources of image degradation in whole-body PET imaging. Simultaneous PET-MR allows measurement of respiratory motion using MRI while collecting PET events. Improved PET images may be obtained by modeling respiratory motion and point spread function (PSF) within the PET iterative reconstruction process. In this study, the authors assessed the relative impact of PSF modeling and MR-based respiratory motion correction in phantoms and patient studies using a whole-body PET-MR scanner. Methods: An asymmetric exponential PSF model accounting for radially varying and axial detector blurring effects was obtained from point source acquisitions performed in the PET-MR scanner. A dedicated MRI acquisition protocol using single-slice steady state free-precession MR acquisitions interleaved with pencil-beam navigator echoes was developed to track respiratory motion during PET-MR studies. An iterative ordinary Poisson fully 3D OSEM PET reconstruction algorithm modeling all the physical effects of the acquisition (attenuation, scatters, random events, detectors efficiencies, PSF), as well as MR-based nonrigid respiratory deformations of tissues (in both emission and attenuation maps) was developed. Phantom and{sup 18}F-FDG PET-MR patient studies were performed to evaluate the proposed quantitative PET-MR methods. Results: The phantom experiment results showed that PSF modeling significantly improved contrast recovery while limiting noise propagation in the reconstruction process. In patients with soft-tissue static lesions, PSF modeling improved lesion contrast by 19.7%–109%, enhancing the detectability and assessment of small tumor foci. In a patient study with small moving hepatic lesions, the proposed reconstruction technique improved lesion contrast by 54.4%–98.1% and reduced apparent lesion size by 21.8%–34.2%. Improvements were particularly important for the smallest lesion undergoing large motion at the lung-liver interface. Heterogeneous tumor structures delineation was substantially improved. Enhancements offered by PSF modeling were more important when correcting for motion at the same time. Conclusions: The results suggest that the proposed quantitative PET-MR methods can significantly enhance the performance of tumor diagnosis and staging as compared to conventional methods. This approach may enable utilization of the full potential of the scanner in oncologic studies of both the lower abdomen, with moving lesions, as well as other parts of the body unaffected by motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation into Practical Implementations of a Zero Knowledge Protocol.

In recent years, the concept of Zero Knowledge Protocols (ZKP) as a useful approach to nuclear warhead verification has become increasingly popular. Several implementations of ZKP have been proposed, driving technology development toward proof of concept demonstrations. Whereas proposed implementations seem to fall within the general class of template-based techniques, all physical implementations of ZKPs proposed to date have a complication: once the instrumentation is prepared, it is no longer authenticatable; the instrument physically contains sensitive information. In this work we explore three different concepts that may offer more authenticatable and practical ZKP implementations and evaluate the sensitive information that may be at risk when doing so: sharing a subset of detector counts in a preloaded image (with spatial information removed), real-time image subtraction, and a new concept, CONfirmation using a Fast-neutron Imaging Detector with Anti-image NULL-positive Time Encoding (CONFIDANTE). CONFIDANTE promises to offer an almost ideal implementation of ZKP: a positive result is indicated by a constant rate at all times enabling the monitoring party the possibility of full access to the instrument before, during, and after confirmation. A prototype of CONFIDANTE was designed, built, and its performance evaluated in a series of measurements of several objects including a set of plutonium dioxide Hemispheres. Very encouraging results proving feasibility are presented. 1 Rebecca is currently a graduate student in Nuclear Engineering at UC Berkeley

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Four-Dimensional CT-Based Evaluation of Techniques for Gastric Irradiation

Purpose: To evaluate three-dimensional conformal (3D-CRT), intensity-modulated (IMRT) and respiration-gated radiotherapy (RGRT) techniques for gastric irradiation for target coverage and minimization of renal doses. All techniques were four-dimensional (4D)-CT based, incorporating the intrafractional mobility of the target volume and organs at risk (OAR). Methods and Materials: The stomach, duodenal C-loop, and OAR (kidneys, liver, and heart) were contoured in all 10 phases of planning 4D-CT scans for five patients who underwent abdominal radiotherapy. Planning target volumes (PTVs) encompassing all positions of the stomach (PTV{sub allphases}) were generated. Three respiratory phases for RGRT in inspiration and expiration were identified, and corresponding PTV{sub inspiration} and PTV{sub expiration} and OAR volumes were created. Landmark-based fields recommended for the Radiation Therapy Oncology Group (RTOG) 99-04 study protocol were simulated to assess PTV coverage. IMRT and 3D-CRT planning with and without additional RGRT planning were performed for all PTVs, and corresponding dose volume histograms were analyzed. Results: Use of landmark-based fields did not result in full geometric coverage of the PTV{sub allphases} in any patient. IMRT significantly reduced mean renal doses compared with 3D-CRT (15.0 Gy {+-} 0.9 Gy vs. 20.1 Gy {+-} 9.3 Gy and 16.6 Gy {+-} 1.5 Gy vs. 32.6 Gy {+-} 7.1 Gy for the left and right kidneys, respectively; p = 0.04). No significant increase in renal sparing was seen when adding RGRT to either 3D-CRT or IMRT. Tolerance doses to the other OAR were not exceeded. Conclusions: Individualized field margins are essential for gastric irradiation. IMRT plans significantly reduce renal doses, but the benefits of RGRT in gastric irradiation appear to be limited.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Total Mercury Analysis of Radioactive Waste Containing Multiple Mercury Species

In this work, a direct mercury analyzer (DMA) was used to analyze total mercury in radioactive waste samples containing methylmercury and other forms of mercury including Hg o (elemental) together with inorganic ionic mercury species and complexes. These samples were also analyzed using Cold Vapor Atomic Absorption Spectroscopy (CVAAS) and/or Inductively Coupled Plasma Mass Spectroscopy (ICMS). Comparative statistical evaluation of the results from spike solutions/simulants, liquid radioactive waste samples, and interlaboratory performance test samples demonstrated that the various methods generated accurate and/or equivalent total mercury data and equivalent precision (2σ ± < 20%). Triplicate total mercury analysis of an exemplar radioactive waste resulted in an average value of 54.1 mg/L (as Hg) using CVAAS, 55.1 mg/L using ICPMS and 56.0 mg/L using DMA. A primary advantage of the DMA in a radioactive environment is avoiding multi-step, labor-intensive, time-consuming and waste-producing sample preparation protocols needed for CVAAS and ICPMS. DMA was determined to be the preferred method for measuring total mercury in the Savannah River National Laboratory (SRNL) radioanalytical laboratory based on analytical performance combined with ease of use in a radiological containment unit.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Position Verification for the Prostate: Effect on Rectal Wall Dose

Purpose: To evaluate the effect of gold marker (GM)-based position correction on the cumulative dose in the anorectal wall compared with traditional bony anatomy (BA)-based correction, taking into account changes in anorectal shape and position. Methods and Materials: A total of 20 consecutive prostate cancer patients, treated with curative external beam radiotherapy, were included. Four fiducial GMs were implanted in the prostate. Positioning was verified according to the shift in BA and GMs on daily electronic portal images. Position corrections were determined using on- and off-line position verification protocols according to the position of the GMs (GM-on and GM-off) and BA (BA-off). For all patients, intensity-modulated radiotherapy plans were made for the GM (8-mm planning target volume margin) and BA (10-mm planning target volume margin) protocols. The dose distribution was recomputed on 11 repeat computed tomography scans to estimate the accumulated dose to the prostate and anorectal wall while considering internal organ motion. Results: The dose that is at least received by 99% of the prostate was, on average, acceptable for all protocols. The individual patient data showed the best coverage for both GM protocols, with >95% of the prescribed dose for all patients. The anorectal wall dose was significantly lower for the GM protocols. The dose that is at least received by 30% of the rectal wall was, on average, 54.6 Gy for GM-on, 54.1 Gy for GM-off, and 58.9 Gy for BA-off (p <.001). Conclusion: Position verification with GM and reduced planning target volume margins yielded adequate treatment of the prostate and a lower rectal wall dose, even when accounting for independent movement of the prostate and anorectal wall.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiscale Simulation of Precipitation Over East Asia by Variable Resolution CAM-MPAS

This study evaluates the precipitation over East Asia simulated by the variable resolution CAM-MPAS featuring the Model for Prediction Across Scales (MPAS) atmospheric dynamical core coupled with the physics parameterizations of the Community Atmosphere Model (CAM) version 5.4. Two CAM-MPAS experiments, one with a global quasi-uniform resolution mesh of 120 km (MPAS-UR) and the other with a variable resolution mesh of 30 to 120 km refined over East Asia (MPAS-VR), are conducted from 1989 to 2005 following the Atmospheric Model Intercomparison Project protocol. Two regional climate model simulations at ~25 km resolution from the Coordinated Regional Downscaling Experiment East Asia second plan are also analyzed for comparison. Results show that CAM-MPAS performs better than the selected regional models in simulating the precipitation climatology over East Asia. Compared with MPAS-UR, MPAS-VR with refinement over East Asia better simulates the precipitation over and around the Tibetan Plateau (TP), the frequency distribution of light, moderate, and heavy precipitation in various regions of China, and the interannual precipitation pattern associated with the East Asian summer monsoon. The improvements in MPAS-VR relative to MPAS-UR largely come from the decreased grid spacing rather than the use of finer-scale terrain information. Particularly, decreased grid spacing is more essential for simulating the precipitation magnitude over TP and the location of peak precipitation south of TP, likely due to the better resolved physical and dynamical processes associated with orographic precipitation. The 30-120 km CAM-MPAS model is shown to be a promising tool for precipitation simulation over East Asia.

54 ENVIRONMENTAL SCIENCES↗

FL‐ADS: Federated learning anomaly detection system for distributed energy resource networks

Abstract With the ongoing development of Distributed Energy Resources (DER) communication networks, the imperative for strong cybersecurity and data privacy safeguards is increasingly evident. DER networks, which rely on protocols such as Distributed Network Protocol 3 and Modbus, are susceptible to cyberattacks such as data integrity breaches and denial of service due to their inherent security vulnerabilities. This paper introduces an innovative Federated Learning (FL)‐based anomaly detection system designed to enhance the security of DER networks while preserving data privacy. Our models leverage Vertical and Horizontal Federated Learning to enable collaborative learning while preserving data privacy, exchanging only non‐sensitive information, such as model parameters, and maintaining the privacy of DER clients' raw data. The effectiveness of the models is demonstrated through its evaluation on datasets representative of real‐world DER scenarios, showcasing significant improvements in accuracy and F1‐score across all clients compared to the traditional baseline model. Additionally, this work demonstrates a consistent reduction in loss function over multiple FL rounds, further validating its efficacy and offering a robust solution that balances effective anomaly detection with stringent data privacy needs.

Purohit, Shaurya [Iowa State University Ames Iowa ↗

Performance Evaluation of Hierarchical Controls for Advanced Distribution Management System-Centered Grid Operations: Preprint

This paper presents a hardware-in-the-loop (HIL) platform to evaluate the performance of voltage regulation using an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge voltage control devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results show proper functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues (e.g., instability) for field deployment.

ADMS↗

Bulk Analysis of International Atomic Energy Agency Environmental Samples in Support of International Safeguards

Inspectors for the International Atomic Energy Agency’s (IAEA) Safeguards Program collect environmental samples under traditional safeguards, strengthened safeguards, or additional protocols during facility inspections at declared nuclear facilities throughout the world. Currently, there are 400 facilities under IAEA safeguards in 70 countries. All environmental samples are returned to IAEA’s Clean Laboratory located in Seiberdorf, Austria, where they are screened for gamma-ray emitting isotopes and prepared for distribution to laboratories for additional sampling. After the sample(s) are analyzed, the results are reported to the United States Network of Analytical Laboratories for input into its database. The IAEA reviews the data and incorporates the results into the safeguards evaluation of the state (country).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Involved-Node Proton Therapy in Combined Modality Therapy for Hodgkin Lymphoma: Results of a Phase 2 Study

Purpose: This study describes the early clinical outcomes of a prospective phase 2 study of consolidative involved-node proton therapy (INPT) as a component of combined-mode therapy in patients with stages I to III Hodgkin lymphoma (HL) with mediastinal involvement. Methods and Materials: Between September 2009 and June 2013, 15 patients with newly diagnosed HL received INPT after completing chemotherapy in an institutional review board-approved protocol comparing the dosimetric impact of PT with those of three-dimensional conformal radiation therapy (3DCRT) and intensity modulated RT. Based on {sup 18}F-Fluorodeoxyglucose positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) response, 5 children received 15 to 25.5 cobalt Gy equivalent (CGE) of INPT after receiving 4 cycles of Adriamycin, Bleomycin, Vincristine, Etoposide, Prednisone, Cyclophosphamide or Vincristine, adriamycin, methotrexate, Prednisone chemotherapy, and 10 adults received 30.6 to 39.6 CGE of INPT after 3 to 6 cycles of Adriamycin, Bleomycine, Vinblastine, Dacarbazine. Patients were routinely evaluated for toxicity during and after treatment, using Common Terminology Criteria for Adverse Events, version 3.0, and for relapse by physical examination and routine imaging. Relapse-free survival (RFS) and event-free survival (EFS) rates were calculated using the Kaplan-Meier method from the time of diagnosis. Results: The median follow-up was 37 months (range, 26-55). Two events occurred during follow-up: 1 relapse (inside and outside the targeted field) and 1 transformation into a primary mediastinal large B cell lymphoma. The 3-year RFS rate was 93%, and the 3-year EFS rate was 87%. No acute or late grade 3 nonhematologic toxicities were observed. Conclusions: Although decades of follow-up will be needed to realize the likely benefit of PT in reducing the risk of radiation-induced late effects, PT following chemotherapy in patients with HL is well-tolerated, and disease outcomes were similar to those of conventional photon therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recovery of Iron/Iron Oxide Nanoparticles from Solution: Comparison of Methods and their Effects

Most methods currently being used to recover Fe0-core/oxide-shell nanoparticles from solutions (including the solvents they are synthesized or stored in) are potentially problematic because they may alter the particle composition (e.g., depositing salts formed from solutes) or leave the particles prone to transformations during subsequent storage and handling (e.g., due to residual moisture). In this study, several methods for recovery of nanoparticles from aqueous solution were studied to determine how they affect the structure and reactivity of the recovered materials. Simple washing of the nanoparticles during vacuum filtration (i.e., “flash drying”) can leave up to ~17 weight percent residual moisture. Modeling calculations suggest this moisture is mostly capillary or matric water held between particles and particle aggregates, which can be removed by drying for short periods at relative vapor pressures below 0.9. Flash drying followed by vacuum drying, all under N2, leaves no detectable residue from precipitation of solutes (detectable by X-ray photoelectron spectroscopy, XPS), no significant changes in overall particle composition or structure (determined by transmission electron microscopy, TEM), and negligible residual moisture (by thermogravimetric analysis, TGA). While this improved flash-drying protocol may be the preferred method for recovering nanoparticles for many purposes, we found that Fe0-core/oxide-shell nanoparticles still exhibit gradual aging during storage when characterized electrochemically with voltammetry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Head and Neck Squamous Cell Carcinomas Do Not Express EGFRvIII

Purpose: To assess the prevalence of EGFRvIII, a specific variant of EGFR (epidermal growth factor receptor), in 3 well-defined cohorts of head and neck squamous cell carcinoma (HNSCC). Methods and Materials: Immunohistochemistry for the specific detection of EGFRvIII using the L8A4 antibody was optimized on formalin-fixed, paraffin-embedded tissue using glioblastoma tissue. It was compared with EGFR and EGFRvIII RNA expression using a specific reverse transcription–polymerase chain reaction also optimized for formalin-fixed, paraffin-embedded tissue. Tissue microarrays including 531 HNSCCs of various stages with complete clinicopathologic and follow-up data were tested for the presence of EGFRvIII. Results: None of the 531 cases showed EGFRvIII protein expression. Using an immunohistochemistry protocol reported by others revealed cytoplasmic staining in 8% of cases. Reverse transcription–polymerase chain reaction for the EGFRvIII transcript of the 28 highest cytoplasmic staining cases, as well as 69 negative cases, did not show expression in any of the tested cases, suggesting aspecific staining by a nonoptimal protocol. Conclusions: The EGFRvIII mutation is not present in HNSCC. Therefore, EGFRvIII does not influence treatment response in HNSCC and is not a usable clinical prognostic marker.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contrast-Enhanced Proton Radiography for Patient Set-up by Using X-Ray CT Prior Knowledge

Purpose: To obtain a contrasted image of the tumor region during the setup for proton therapy in lung patients, by using proton radiography and x-ray computed tomography (CT) prior knowledge. Methods and Materials: Six lung cancer patients' CT scans were preprocessed by masking out the gross tumor volume (GTV), and digitally reconstructed radiographs along the planned beam's eye view (BEV) were generated, for a total of 27 projections. Proton radiographies (PR) were also computed for the same BEV through Monte Carlo simulations. The digitally reconstructed radiograph was subtracted from the corresponding proton image, resulting in a contrast-enhanced proton radiography (CEPR). Michelson contrast analysis was performed both on PR and CEPR. The tumor region was then automatically segmented on CEPR and compared to the ground truth (GT) provided by physicians in terms of Dice coefficient, accuracy, precision, sensitivity, and specificity. Results: Contrast on CEPR was, on average, 4 times better than on PR. For 10 lateral projections (±45° off of 90° or 270°), although it was not possible to distinguish the tumor region in the PR, CEPR offers excellent GTV visibility. The median ± quartile values of Dice, precision, and accuracy indexes were 0.86 ± 0.03, 0.86 ± 0.06, and 0.88 ± 0.02, respectively, thus confirming the reliability of the method in highlighting tumor boundaries. Sensitivity and specificity analysis demonstrated that there is no systematic over- or underestimation of the tumor region. Identification of the tumor boundaries using CEPR resulted in a more accurate and precise definition of GTV compared to that obtained from pretreatment CT. Conclusions: In most proton centers, the current clinical protocol is to align the patient using kV imaging with bony anatomy as a reference. We demonstrated that CEPR can significantly improve tumor visualization, allowing better patient set-up and permitting image guided proton therapy (IGPT)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy

Purpose: To retrospectively evaluate the accuracy, plan quality and efficiency of intensity-modulated arc therapy (IMAT) for hippocampal sparing whole-brain radiotherapy (HS-WBRT) with simultaneous integrated boost (SIB) in patients with multiple brain metastases (m-BM). Materials and methods: A total of 5 patients with m-BM were retrospectively replanned for HS-WBRT with SIB using IMAT treatment planning. The hippocampus was contoured on diagnostic T1-weighted magnetic resonance imaging (MRI) which had been fused with the planning CT image set. The hippocampal avoidance zone (HAZ) was generated using a 5-mm uniform margin around the paired hippocampi. The m-BM planning target volumes (PTVs) were contoured on T1/T2-weighted MRI registered with the 3D planning computed tomography (CT). The whole-brain planning target volume (WB-PTV) was defined as the whole-brain tissue volume minus HAZ and m-BM PTVs. Highly conformal IMAT plans were generated in the Eclipse treatment planning system for Novalis-TX linear accelerator consisting of high-definition multileaf collimators (HD-MLCs: 2.5-mm leaf width at isocenter) and 6-MV beam. Prescription dose was 30 Gy for WB-PTV and 45 Gy for each m-BM in 10 fractions. Three full coplanar arcs with orbit avoidance sectors were used. Treatment plans were evaluated using homogeneity (HI) and conformity indices (CI) for target coverage and dose to organs at risk (OAR). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance (QA) with a MapCHECK device. Actual beam-on time was recorded and a gamma index was used to compare dose agreement between the planned and measured doses. Results: All 5 HS-WBRT with SIB plans met WB-PTV D{sub 2%}, D{sub 98%}, and V{sub 30} {sub Gy} NRG-CC001 requirements. The plans demonstrated highly conformal and homogenous coverage of the WB-PTV with mean HI and CI values of 0.33 ± 0.04 (range: 0.27 to 0.36), and 0.96 ± 0.01 (range: 0.95 to 0.97), respectively. All 5 hippocampal sparing patients met protocol guidelines with maximum dose and dose to 100% of hippocampus (D{sub 100%}) less than 16 and 9 Gy, respectively. The dose to the optic apparatus was kept below protocol guidelines for all 5 patients. Highly conformal and homogenous radiosurgical dose distributions were achieved for all 5 patients with a total of 33 brain metastases. The m-BM PTVs had a mean HI = 0.09 ± 0.02 (range: 0.07 to 0.19) and a mean CI = 1.02 ± 0.06 (range: 0.93 to 1.2). The total number of monitor units (MU) was, on average, 1677 ± 166. The average beam-on time was 4.1 ± 0.4 minute . The IMAT plans demonstrated accurate dose delivery of 95.2 ± 0.6%, on average, for clinical gamma passing rate with 2%/2-mm criteria and 98.5 ± 0.9%, on average, with 3%/3-mm criteria. Conclusions: All hippocampal sparing plans were considered clinically acceptable per NRG-CC001 dosimetric compliance criteria. IMAT planning provided highly conformal and homogenous dose distributions for the WB-PTV and m-BM PTVs with lower doses to OAR such as the hippocampus. These results suggest that HS-WBRT with SIB is a clinically feasible, fast, and effective treatment option for patients with a relatively large numbers of m-BM lesions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190

Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, “dose-area-product” (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG-190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term “DAP-meter” has been revised to air kerma-area product (KAP) meter. The charge of TG 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the “Accuracy and Calibration of Integrated Radiation Output Indicators” which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical “meter.” To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field.

60 APPLIED LIFE SCIENCES↗

Radiopaque Resists for Two-Photon Lithography To Enable Submicron 3D Imaging of Polymer Parts via X-ray Computed Tomography

Two-photon lithography (TPL) is a high-resolution additive manufacturing (AM) technique capable of producing arbitrarily complex three-dimensional (3D) microstructures with features 2–3 orders of magnitude finer than human hair. This process finds numerous applications as a direct route toward the fabrication of novel optical and mechanical metamaterials, miniaturized optics, microfluidics, biological scaffolds, and various other intricate 3D parts. As TPL matures, metrology and inspection become a crucial step in the manufacturing process to ensure that the geometric form of the end product meets design specifications. X-ray-based computed tomography (CT) is a nondestructive technique that can provide this inspection capability for the evaluation of complex internal 3D structure. However, polymeric photoresists commonly used for TPL, as well as other forms of stereolithography, poorly attenuate X-rays due to the low atomic number (Z) of their constituent elements and therefore appear relatively transparent during imaging. We present the development of optically clear yet radiopaque photoresists for enhanced contrast under X-ray CT. We have synthesized iodinated acrylate monomers to formulate high-Z photoresist materials that are capable of forming 3D microstructures with sub-150 nm features. In addition, we have developed a formulation protocol to match the refractive index of the photoresists to the immersion medium of the objective lens so as to enable dip-in laser lithography, a direct laser writing technique for producing millimeter-tall structures. Our radiopaque photopolymer then resists increase X-ray attenuation by a factor of more than 10 times without sacrificing the sub-150 nm feature resolution or the millimeter-scale part height. Thus, our resists can successfully replace existing photopolymers to generate AM parts that are suitable for inspection via X-ray CT. By providing the “feedstock” for radiopaque AM parts, our resist formulation is expected to play a critical role in enabling fabrication of functional polymer parts to tight design tolerances.

36 MATERIALS SCIENCE↗

Gate oxide process control optimization by x-ray photoelectron spectroscopy in a semiconductor fabrication line

X-ray photoelectron spectroscopy is a metrology technique that is used for in-line control of decoupled plasma nitridation processes in the fabrication of logic devices. This article shows XPS results of thickness and composition obtained on two types of gate oxide nitrided by a decoupled plasma nitridation process. Measurements are performed in specific test structures with an x-ray spot which can be focused down to 35 {mu}m, enabling process control directly on products. First, XPS is used to characterize and quantify the chemical composition of a SiON layer. The Results show that the nitrogen composition in a SiON layer decreases at a fast rate during the initial days after nitridation processing and stabilizes with time. Second, measurements are performed on products with the objective of transferring process control from monitor to product wafers. In this regard, comparison of nitrogen dose and thickness uniformity on monitor and pattern wafers show similar trends, indicating that measurements of nitrogen dose and thickness on monitor and product wafers give the same information. Third, different mapping protocols are studied on products to identify the best compromise between throughput and an optimized mapping representative of the process distribution. An optimized process control strategy of gate oxides with results is discussed in this article.

36 MATERIALS SCIENCE↗

Novel spirometry based on optical surface imaging

Purpose: To evaluate the feasibility of using optical surface imaging (OSI) to measure the dynamic tidal volume (TV) of the human torso during free breathing. Methods: We performed experiments to measure volume or volume change in geometric and deformable phantoms as well as human subjects using OSI. To assess the accuracy of OSI in volume determination, we performed experiments using five geometric phantoms and two deformable body phantoms and compared the values with those derived from geometric calculations and computed tomography (CT) measurements, respectively. To apply this technique to human subjects, an institutional review board protocol was established and three healthy volunteers were studied. In the human experiment, a high-speed image capture mode of OSI was applied to acquire torso images at 4–5 frames per second, which was synchronized with conventional spirometric measurements at 5 Hz. An in-house MATLAB program was developed to interactively define the volume of interest (VOI), separate the thorax and abdomen, and automatically calculate the thoracic and abdominal volumes within the VOIs. The torso volume change (TV C = ΔV{sub torso} = ΔV{sub thorax} + ΔV{sub abdomen}) was automatically calculated using full-exhalation phase as the reference. The volumetric breathing pattern (BP{sub v} = ΔV{sub thorax}/ΔV{sub torso}) quantifying thoracic and abdominal volume variations was also calculated. Under quiet breathing, TVC should equal the tidal volume measured concurrently by a spirometer with a conversion factor (1.08) accounting for internal and external differences of temperature and moisture. Another MATLAB program was implemented to control the conventional spirometer that was used as the standard. Results: The volumes measured from the OSI imaging of geometric phantoms agreed with the calculated volumes with a discrepancy of 0.0% ± 1.6% (range −1.9% to 2.5%). In measurements from the deformable torso/thorax phantoms, the volume differences measured using OSI imaging and CT imaging were 1.2% ± 2.1% (range −0.5% to 3.6%), with a linear regression fitting (slope = 1.02 and R{sup 2} = 0.999). In volunteers, the relative error in OSI tidal volume measurement was −2.2% ± 4.9% (range −9.2% to 4.8%) and a correlation of r = 0.98 was found with spirometric measurement. The breathing pattern values of the three volunteers were substantially different from each other (BP{sub v} = 0.15, 0.45, and 0.32). Conclusions: This study demonstrates the feasibility of using OSI to measure breathing tidal volumes and breathing patterns with adequate accuracy. This is the first time that dynamic breathing tidal volume as well as breathing patterns is measured using optical surface imaging. The OSI-observed movement of the entire torso could serve as a new respiratory surrogate in the treatment room during radiation therapy.

60 APPLIED LIFE SCIENCES↗