Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid responsive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

SU-E-J-12: A New Stereological Method for Tumor Volume Evaluation for Esophageal Cancer

Purpose: Stereological method used to obtain three dimensional quantitative information from two dimensional images is a widely used tool in the study of cells and pathology. But the feasibility of the method for quantitative evaluation of volumes with 3D image data sets for radiotherapy clinical application has not been explored. On the other hand, a quick, easy-to-use and reliable method is highly desired in image-guided-radiotherapy(IGRT) for tumor volume measurement for the assessment of response to treatment. To meet this need, a stereological method for evaluating tumor volumes for esophageal cancer is presented in this abstract. Methods: The stereology method was optimized by selecting the appropriate grid point distances and sample types. 7 patients with esophageal cancer were selected retrospectively for this study, each having pre and post treatment computed tomography (CT) scans. Stereological measurements were performed for evaluating the gross tumor volume (GTV) changes after radiotherapy and the results was compared with the ones by planimetric measurements. Two independent observers evaluated the reproducibility for volume measurement using the new stereological technique. Results: The intraobserver variation in the GTV volume estimation was 3.42±1.68cm3 (the Wilcoxon matched-pairs test Resultwas Z=−1.726,P=0.084>0.05); the interobserver variation in the GTV volume estimation was 22.40±7.23 cm3 (Z=−3.296,P=0.083>0.05), which showed the consistency in GTV volume calculation with the new method for the same and different users. The agreement level between the results from the two techniques was also evaluated. Difference between the measured GTVs was 20.10±5.35 cm3 (Z=−3.101,P=0.089>0.05). Variation of the measurement results using the two techniques was low and clinically acceptable. Conclusion: The good agreement between stereological and planimetric techniques proves the reliability of the stereological tumor volume estimations. The optimized stereological technique described in this abstract may provide a quick, unbiased and reproducible tool for tumor volume estimation for treatment response assessment. Supported by NSFC (#81041107, #81171342 and #31000784)

60 APPLIED LIFE SCIENCES↗

Electric Grid Supply Chain Review: Large Power Transformers and High Voltage Direct Current Systems

The report “America’s Strategy to Secure the Supply Chain for a Robust Clean Energy Transition” lays out the challenges and opportunities faced by the United States in the energy supply chain as well as the federal government plans to address these challenges and opportunities. It is accompanied by several issue-specific deep dive assessments, including this one, in response to Executive Order 14017 “America’s Supply Chains,” which directs the Secretary of Energy to submit a report on supply chains for the energy sector industrial base. The Executive Order is helping the federal government to build more secure and diverse U.S. supply chains, including energy supply chains. The need to modernize and increase the capacity of the U.S. power grid is increasing due to growing population, aging infrastructure, grid resilience requirements, operational flexibility needs, and a growing portfolio of renewable energy. As part of the Paris Climate Agreement the United States has committed to reducing its net greenhouse gas emissions by 50 to 52 percent below 2005 levels in 2030 and has set a goal of 100 percent carbon pollution free electricity by 2035 (The United States of America Nationally Determined Contribution, 2021). Meeting these targets will require a significant expansion of the power system to integrate a large amount of new renewable resources (United States Department of State & United States Executive Office of the President, 2021). However, many critical components supporting the power grid have limited to no domestic manufacturing capacity and face complex challenges in supporting a rapid expansion of the grid to meet multiple objectives, including decarbonization goals. This report focuses on two key grid components: large power transformers (LPTs) and high-voltage direct current (HVDC) transmission.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Irvine Smart Grid Demonstration, a Regional Smart Grid Demonstration Project

ISGD was a comprehensive demonstration that spanned the electricity delivery system and extended into customer homes. The project used phasor measurement technology to enable substation-level situational awareness, and demonstrated SCE’s next-generation substation automation system. It extended beyond the substation to evaluate the latest generation of distribution automation technologies, including looped 12-kV distribution circuit topology using URCIs. The project team used DVVC capabilities to demonstrate CVR. In customer homes, the project evaluated HAN devices such as smart appliances, programmable communicating thermostats, and home energy management components. The homes were also equipped with energy storage, solar PV systems, and a number of energy efficiency measures (EEMs). The team used one block of homes to evaluate strategies and technologies for achieving ZNE. A home achieves ZNE when it produces at least as much renewable energy as the amount of energy it consumes annually. The project also assessed the impact of device-specific demand response (DR), as well as load management capabilities involving energy storage devices and plug-in electric vehicle charging equipment. In addition, the ISGD project sought to better understand the impact of ZNE homes on the electric grid. ISGD’s SENet enabled end-to-end interoperability between multiple vendors’ systems and devices, while also providing a level of cybersecurity that is essential to smart grid development and adoption across the nation. The ISGD project includes a series of sub-projects grouped into four logical technology domains: Smart Energy Customer Solutions, Next-Generation Distribution System, Interoperability and Cybersecurity, and Workforce of the Future. Section 2.3 provides a more detailed overview of these domains.

25 ENERGY STORAGE↗

Demand Response Operation of Electricity-Intensive Chemical Processes for Reduced Greenhouse Gas Emissions: Application to an Air Separation Unit

A recent push for reduced greenhouse gas (GHG) emissions has led (in part) to the addition of renewable electricity generation sources to the power generation mix. Renewables such as wind and solar are desynchronized from grid demand, requiring the use of fossil fuels to bridge the gap. We propose a novel production scheduling formulation, emissions-minimizing production (EMP), which utilizes time-based information on the nature of the power generation mix to lower GHG emissions related to the transmission and generation of electricity for industrial users. We demonstrate the application of EMP on a single-column air separation unit. The scheduling problem is cast as a mixed integer linear program that can be solved in a practical amount of time. Extensive numerical studies are used to place EMP in the context of other production scheduling methods (such as demand response), and demonstrate its potential for significant reductions in GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tidally averaged circulation in Puget Sound sub-basins: Comparison of historical data, analytical model, and numerical model

Through extensive field data collection and analysis efforts conducted since the 1950s, researchers have established an understanding of the characteristic features of circulation in Puget Sound. The pattern ranges from the classic fjordal behavior in some basins, with shallow brackish outflow and compensating inflow immediately below, to the typical two-layer flow observed in many partially mixed estuaries with saline inflow at depth. An attempt at reproducing this behavior by fitting an analytical formulation to past data is presented, followed by the application of a three-dimensional circulation and transport numerical model. The analytical treatment helped identify key physical processes and parameters, but quickly reconfirmed that response is complex and would require site-specific parameterization to include effects of sills and interconnected basins. The numerical model of Puget Sound, developed using unstructured-grid finite volume method, allowed resolution of the sub-basin geometric features, including presence of major islands, and site-specific strong advective vertical mixing created by bathymetry and multiple sills. The model was calibrated using available recent short-term oceanographic time series data sets from different parts of the Puget Sound basin. The results are compared against (1) recent velocity and salinity data collected in Puget Sound from 2006 and (2) a composite data set from previously analyzed historical records, mostly from the 1970s. The results highlight the ability of the model to reproduce velocity and salinity profile characteristics, their variations among Puget Sound subbasins, and tidally averaged circulation. Sensitivity of residual circulation to variations in freshwater inflow and resulting salinity gradient in fjordal sub-basins of Puget Sound is examined.

58 GEOSCIENCES↗

In Silico Simulation of a Clinical Trial Concerning Tumour Response to Radiotherapy

The aim of this paper is to demonstrate how multilevel tumour growth and response to therapeutic treatment models can be used in order to simulate clinical trials, with the long-term intention of both better designing clinical studies and understanding their outcome based on basic biological science. For this purpose, an already developed computer simulation model of glioblastoma multiforme response to radiotherapy has been used and a clinical study concerning glioblastoma multiforme response to radiotherapy has been simulated. In order to facilitate the simulation of such virtual trials, a toolkit enabling the user-friendly execution of the simulations on grid infrastructures has been designed and developed. The results of the conducted virtual trial are in agreement with the outcome of the real clinical study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatially resolved probing of Preisach density in polycrystalline ferroelectric thin films

Applications of the ferroelectric materials for the information storage necessitate the understanding of local switching behavior on the level of individual grains and microstructural elements. In particular, implementation of multilevel neuromorphic elements requires the understanding of history-dependent polarization responses. Here, we introduce the spatially resolved approach for mapping local Preisach densities in polycrystalline ferroelectrics based on first-order reversal curve (FORC) measurements over spatially resolved grid by piezoresponse force spectroscopy using tip-electrode. The band excitation approach allowed effective use of cantilever resonances to amplify weak piezoelectric signal and also provided insight in position-, voltage-, and voltage history-dependent mechanical properties of the tip-surface contact. Several approaches for visualization and comparison of the multidimensional data sets formed by FORC families or Preisach densities at each point are introduced and compared. The relationship between switching behavior and microstructure is analyzed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Average Model Predictive Control of Quasi-Z-Source Modular Cascaded Photovoltaic Converter

An average model predictive control (AMPC) is proposed for dc grid integration of the front-end isolated quasi-Z-source modular cascaded converter (qZS-MCC) photovoltaic (PV) power system. The qZS-MCC deals with PV maximum power point tracking (MPPT), dc grid integration, and de-link voltage balance by the post-stage qZS half-bridge (HB) dc-dc converters, while a unified duty cycle is used in the front-end isolation converters of all submodules (SMs). Thus, it reduces the control resources while overcoming the dc-bus voltage limit because of the PV panel insulation demand. The proposed AMPC of qZS-MCC PV power system predicts the shoot-through duty cycle of each SM for dc-link voltage control, and the total modulation index for dc grid-connected current control; only one proportional-integral (PI) regulator for PV MPPT is required in each SM. Thus, PI regulators are significantly reduced, whereas system dynamic responses are improved, with low computation and simple implementation. Simulation and downscaled experimental results demonstrate the effectiveness of the proposed control.

Liu, Yushan↗

Fuzzy-Logic Subsumption Controller for Home Energy Management Systems

Home Energy Management Systems (HEMS) are controllers that manage and coordinate the generation, storage, and loads in a home. These controllers are increasingly necessary to ensure that increasing penetrations of distributed energy resources are used effectively and do not disrupt the operation of the grid. In this paper, we propose a novel approach to HEMS design based on behavioral control methods, which do not require accurate models or predictions and are very responsive to changing conditions. We develop a proof-of-concept behavioral HEMS controller and show by simulation on an example home energy system that it capable of making context-dependent tradeoffs between goals under challenging conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Kimberlina 1.2 CCUS Geophysical Models and Synthetic Data Sets

This synthetic multi-scale and multi-physics data set was produced in collaboration with teams at the Lawrence Berkeley National Laboratory, National Energy Technology Laboratory, Los Alamos National Laboratory, and Colorado School of Mines through the Science-informed Machine Learning for Accelerating Real-Time Decisions in Subsurface Applications (SMART) Initiative. Data are associated with the following publication: Alumbaugh, D., Gasperikova, E., Crandall, D., Commer, M., Feng, S., Harbert, W., Li, Y., Lin, Y., and Samarasinghe, S., “The Kimberlina Synthetic Geophysical Model and Data Set for CO2 Monitoring Investigations”, The Geoscience Data Journal, 2023, DOI: 10.1002/gdj3.191. The dataset uses the Kimberlina 1.2 CO2 reservoir flow model simulations based on a hypothetical CO2 storage site in California (Birkholzer et al., 2011; Wainwright et al., 2013). Geophysical properties models (P- and S-wave seismic velocities, saturated density, and electrical resistivity) were produced with an approach similar to that of Yang et al. (2019) and Gasperikova et al. (2022) for 100 Kimberlina 1.2 reservoir models. Links to individual resources are provided below: [CO2 Saturation Models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-co2-saturation-models); Resistivity Models – [part 1](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-resistivity-models-part-1), [part 2](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-resistivity-models-part-2), and [part 3](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-resistivity-models-part-3); [Vp Velocity Models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-vp-velocity-models); [Vs Velocity Models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-vs-velocity-models); [Density Models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-density-models). The 3D distributions of geophysical properties for the 33 time stamps of the SIM001 model were used to generate synthetic seismic, gravity, and electromagnetic (EM) responses for 33 times between zero and 200 years. Synthetic surface seismic data were generated using 2D and 3D finite-difference codes that simulate the acoustic wave equation (Moczo et al., 2007). 2D data were simulated for six point-pressure sources along a 2D line with 10 m receiver spacing and a time spacing of 0.0005 s. 3D simulations were completed for 25 surface pressure sources using a source separation of 1 km in both the x and y directions and a time spacing of 0.001 s. Links to individual resources are provided below: [2D velocity models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-2d-velocity-models) and [2D surface seismic data](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-2d-surface-seismic-data). [3D velocity models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-velocity-models), and 3D seismic data [year0](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year0), [year1](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year1), [year2](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year2), [year5](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year5), [year10](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year10), [year15](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year15), [year20](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year20), [year25](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year25), [year30](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year30), [year35](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year35), [year40](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year40), [year45](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year45), [year49](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year49), [year50](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year50), [year51](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year51), [year52](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year52), [year55](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year55), [year60](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year60), [year65](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year65), [year70](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year70), [year75](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year75), [year80](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year80), [year85](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year85), [year90](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year90), [year95](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year95), [year100](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year100), [year110](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year110), [year120](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year120), [year130](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year130), [year140](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year140), [year150](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year150), [year175](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year175), [year200](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year200). The Python scripts to read these models and data are provided [here](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-python-scripts). EM simulations used a borehole-to-surface survey configuration, with the source located near the reservoir level and receivers on the surface using the code developed by Commer and Newman (2008). Pseudo-2D data for the source at [2500 m](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-pseudo-2d-csem-data-tz2500m) and [3025 m](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-pseudo-2d-csem-data-tz3025m), used a 2D inline receiver configuration to simulate a response over 3D resistivity models. The [3D data](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-csem-data) contain electric fields generated by borehole sources at monitoring well locations and measured over a surface receiver grid. Vector gravity data, both on the surface and in boreholes, were simulated using a modeling code developed by Rim and Li (2015). The simulation scenarios were parallel to those used for the EM: [pseudo-2D data](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-gravity-data) were calculated along the same lines and within the same boreholes, and [3D data](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-gravity-data) were simulated over 3D models on the surface and in three monitoring wells. A series of [synthetic well logs](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-well-logs) of CO2 saturation, acoustic velocity, density, and induction resistivity in the injection well and three monitoring wells are also provided at 0, 1, 2, 5, 10, 15, and 20 years after the initiation of injection. These were constructed by combining the low-frequency trend of the geophysical models with the high-frequency variations of actual well logs collected in the Kimberlina 1 well that was drilled at the proposed site. Measurements of permeability and pore connectivity were made on cores of Vedder Sandstone, which forms the primary reservoir unit: [CT micro scans](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-ct-micro-scans-of-vedder-formation) and [Industrial CT Images](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-industrial-ct-images-vedder-formation). These measurements provide the range of scales in the otherwise synthetic data set to be as close to a real-world situation as possible. References: Birkholzer, J.T., Zhou, Q., Cortis, A. and Finsterle, S., 2011. A sensitivity study on regional pressure buildup from large-scale CO2 storage projects. Energy Procedia, 4, 4371-4378. Commer, M., and Newman, G.A., 2008. New advances in three-dimensional controlled-source electromagnetic inversion, Geophysical Journal International, 172, 513-535. Gasperikova, E., Appriou, D., Bonneville, A., Feng, Z., Huang, L., Gao, K., Yang, X., Daley, T., 2022, Sensitivity of geophysical techniques for monitoring secondary CO2 storage plumes, Int. J. Greenh. Gas Control, Volume 114, 103585, ISSN 1750-5836, https://doi.org/10.1016/j.ijggc.2022.103585. Moczo, P., J.O. Robertsson and L. Eisner, 2007, The finite-difference time-domain method for modeling of seismic wave propagation: Advances in geophysics, 48, 421-516. Rim, H., and Y. Li, 2015, Advantages of borehole vector gravity in density imaging, Geophysics, 80, G1-G13. Wainwright, H. M.; Finsterle, S.; Zhou, Q.; Birkholzer, J. T., 2013. Modeling the Performance of Large-Scale CO2 Storage Systems: A Comparison of Different Sensitivity Analysis Methods. International Journal of Greenhouse Gas Control, 17, 189205. https://doi.org/10.1016/j.ijggc.2013.05.007, DOI: 10.18141/1603331. Yang, X., Buscheck, T.A., Mansoor, K., Wang, Z., Gao, K., Huang, L., Appriou, D., and Carroll, S.A., 2019. Assessment of geophysical monitoring methods for detection of brine and CO2 leakage in drinking water aquifers, International Journal of Greenhouse Gas Control, 90, 102803, https://doi.org/10.1016/j.ijggc.2019.102803.

CCUS↗

Fundamental Drivers of the Cost and Price of Operating Reserves

Operating reserves impose a cost on the electric power system by forcing system operators to keep partially loaded spinning generators available for responding to system contingencies variable demand. In many regions of the United States, thermal power plants provide a large fraction of the operating reserve requirement. Alternative sources of operating reserves, such as demand response and energy storage, may provide more efficient sources of these reserves. However, to estimate the potential value of these services, the cost of reserve services under various grid conditions must first be established. This analysis used a commercial grid simulation tool to evaluate the cost and price of several operating reserve services, including spinning contingency reserves and upward regulation reserves. These reserve products were evaluated in a utility system in the western United States, considering different system flexibilities, renewable energy penetration, and other sensitivities. The analysis demonstrates that the price of operating reserves depend highly on many assumptions regarding the operational flexibility of the generation fleet, including ramp rates and the fraction of fleet available to provide reserves.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Possible Energy Storage Legislation for New Mexico [Slides]

Energy security is a core component of the national mission of Los Alamos National Laboratory and an emerging initiative, with about $10M in play now. Los Alamos National Laboratory is a leading laboratory for fuel cells, smart grid, wind resource allocation, and biofuels. The New Mexico Legislature demonstrates interest and leadership in maximizing all our state’s natural energy resources. We are here today in response to requests originated by Representative Hall and Chairman Keller for potential legislation for a New Mexico energy storage strategy. In preparation for today’s testimony, we have accommodated input from a broad spectrum of stakeholders.

25 ENERGY STORAGE↗

Fundamental Drivers of the Cost and Price of Operating Reserves

Operating reserves impose a cost on the electric power system by forcing system operators to keep partially loaded spinning generators available for responding to system contingencies variable demand. In many regions of the United States, thermal power plants provide a large fraction of the operating reserve requirement. Alternative sources of operating reserves, such as demand response and energy storage, may provide more efficient sources of these reserves. However, to estimate the potential value of these services, the cost of reserve services under various grid conditions must first be established. This analysis used a commercial grid simulation tool to evaluate the cost and price of several operating reserve services, including spinning contingency reserves and upward regulation reserves. These reserve products were evaluated in a utility system in the western United States, considering different system flexibilities, renewable energy penetration, and other sensitivities. The analysis demonstrates that the price of operating reserves depend highly on many assumptions regarding the operational flexibility of the generation fleet, including ramp rates and the fraction of fleet available to provide reserves.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Examples of State and Utility Actions on Proactive Planning and Investments

As states across the U.S. confront rising electricity demand, clean energy deployment, grid modernization imperatives, and the integration of large new loads, some regulators and utilities are shifting away from reactive, “just-in-time” investment approaches toward more proactive planning and investment frameworks. This report compiles examples of jurisdictional and utility actions that reshape planning processes, cost recovery mechanisms, and performance oversight to anticipate—rather than simply respond to—future grid needs. Several themes emerge from state actions examined in this report. First, legislatures and commissions are increasingly directing utilities to proactively upgrade their distribution and transmission systems, reflecting a shift toward a forward-looking system that aligns planning with state policy goals. Second, states are establishing long-term, iterative planning frameworks that often feature multi-year horizons, biannual or annual compliance reporting, structured opportunities for stakeholder engagement, and emphasis on collaboration among utilities, regulators, and stakeholders. Third, states are actively investigating innovative cost recovery mechanisms designed to support accelerated electrification and grid modernization, while balancing consumer advocates’ concerns regarding the ratepayer financial risks of premature investments. Fourth, performance metrics and reporting requirements are being developed to ensure transparency and accountability for proactive investments. Fifth, methodological improvements in planning—such as aligning load forecasting assumptions, incorporating sensitivities, and considering load management potential across building, vehicles, storage, and demand response—are recurring areas of stakeholder focus across jurisdictions. Overall, these developments signify a growing recognition among state regulators, utilities, and stakeholders that proactive planning—supported by clear definitions, consistent and transparent methodologies, robust performance metrics, and innovative cost recovery mechanisms—is a tool that can be used to address the scale and urgency of contemporary grid needs.

electricity market↗

Grid-Interactive Multi-Zone Building Control Using Reinforcement Learning with Global-Local Policy Search

In this paper, we develop a grid-interactive multi-zone building controller based on a deep reinforcement learning (RL) approach. The controller is designed to facilitate building operation during normal conditions and demand response events, while ensuring occupants comfort and energy efficiency. We leverage a continuous action space RL formulation, and devise a two-stage global-local RL training framework. In the first stage, a global fast policy search is performed using a gradient-free RL algorithm. In the second stage, a local fine-tuning is conducted using a policy gradient method. In contrast to the state-of-the-art model predictive control (MPC) approach, the proposed RL controller does not require complex computation during real-time operation and can adapt to nonlinear building models. We illustrate the controller performance numerically using a five-zone commercial building.

30 DIRECT ENERGY CONVERSION↗

A Fuzzy-Logic Subsumption Controller for Home Energy Management Systems

Presentation for NAPS 2015 associated with conference publication CP-64392. Home Energy Management Systems (HEMS) are controllers that manage and coordinate the generation, storage, and loads in a home. These controllers are increasingly necessary to ensure that increasing penetrations of distributed energy resources are used effectively and do not disrupt the operation of the grid. In this paper, we propose a novel approach to HEMS design based on behavioral control methods, which do not require accurate models or predictions and are very responsive to changing conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid-Interactive Multi-Zone Building Control Using Reinforcement Learning with Global-Local Policy Search: Preprint

In this paper, we develop a grid-interactive multi-zone building controller based on a deep reinforcement learning (RL) approach. The controller is designed to facilitate building operation during normal conditions and demand response events, while ensuring occupants comfort and energy efficiency. We leverage a continuous action space RL formulation, and devise a two-stage global-local RL training framework. In the first stage, a global fast policy search is performed using a gradient-free RL algorithm. In the second stage, a local fine-tuning is conducted using a policy gradient method. In contrast to the state-of-the-art model predictive control (MPC) approach, the proposed RL controller does not require complex computation during real-time operation and can adapt to non-linear building models. We illustrate the controller performance numerically using a five-zone commercial building.

30 DIRECT ENERGY CONVERSION↗

High-Performance Computing for Real-Time Grid Analysis and Operation

Power grids worldwide are undergoing an unprecedented transition as a result of grid evolution meeting information revolution. The grid evolution is largely driven by the desire for green energy. Emerging grid technologies such as renewable generation, smart loads, plug-in hybrid vehicles, and distributed generation provide opportunities to generate energy from green sources and to manage energy use for better system efficiency. With utility companies actively deploying these technologies, a high level of penetration of these new technologies is expected in the next 5-10 years, bringing in a level of intermittency, uncertainties, and complexity that the grid did not see nor design for. On the other hand, the information infrastructure in the power grid is being revolutionized with large-scale deployment of sensors and meters in both the transmission and distribution networks. The future grid will have two-way flows of both electrons and information. The challenge is how to take advantage of the information revolution: pull the large amount of data in, process it in real time, and put information out to manage grid evolution. Without addressing this challenge, the opportunities in grid evolution will remain unfulfilled. This transition poses grand challenges in grid modeling, simulation, and information presentation. The computational complexity of underlying power grid modeling and simulation will significantly increase in the next decade due to an increased model size and a decreased time window allowed to compute model solutions. High-performance computing is essential to enable this transition. The essential technical barrier is to vastly increase the computational speed so operation response time can be reduced from minutes to seconds and sub-seconds. The speed at which key functions such as state estimation and contingency analysis are conducted (typically every 3-5 minutes) needs to be dramatically increased so that the analysis of contingencies is both comprehensive and real time. An even bigger challenge is how to incorporate dynamic information into real-time grid operation. Today’s online grid operation is based on a static grid model and can only provide a static snapshot of current system operation status, while dynamic analysis is conducted offline because of low computational efficiency. The offline analysis uses a worst-case scenario to determine transmission limits, resulting in under-utilization of grid assets. This conservative approach does not necessarily lead to reliability. Many times, actual power grid scenarios are not studied, and they will push the grid over the edge and resulting in outages and blackouts. This chapter addresses the HPC needs in power grid analysis and operations. Example applications such as state estimation and contingency analysis are given to demonstrate the value of HPC in power grid applications. Future research directions are suggested for high performance computing applications in power grids to improve the transparency, efficiency, and reliability of power grids.

Contingency Analysis↗