Search NASA⌕ Search

SEARCH · Search NASA

Results for “guide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Cyberknife Image-Guided Delivery and Quality Assurance

The CyberKnife is a complex, emerging technology that is a significant departure from current stereotactic radiosurgery and external beam radiotherapy technologies. In its clinical application and quality assurance (QA) approach, the CyberKnife is currently situated somewhere in between stereotactic radiosurgery and radiotherapy. The clinical QA for this image-guided treatment delivery system typically follows the vendor's guidance, mainly because of the current lack of vendor-independent QA recommendations. The problem has been exacerbated because very little published data are available for QA for the CyberKnife system, especially for QA of the interaction between individual system components. The tools and techniques for QA of the CyberKnife are under development and will continue to improve with longer clinical experience of the users. The technology itself continues to evolve, forcing continuous changes and adaptation of QA. To aid in the process of developing comprehensive guidance on CyberKnife QA, a database of errors based on users reporting incidents and corrective actions would be desirable. The goal of this work was to discuss the status of QA guidelines in the clinical implementation of the CyberKnife system. This investigation was done from the perspective of an active clinical and research site using the CyberKnife.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Developing Quality Assurance Processes for Image-Guided Adaptive Radiation Therapy

Quality assurance has long been implemented in radiation treatment as systematic actions necessary to provide adequate confidence that the radiation oncology service will satisfy the given requirements for quality care. The existing reports from the American Association of Physicists in Medicine Task Groups 40 and 53 have provided highly detailed QA guidelines for conventional radiotherapy and treatment planning. However, advanced treatment processes recently developed with emerging high technology have introduced new QA requirements that have not been addressed previously in the conventional QA program. Therefore, it is necessary to expand the existing QA guidelines to also include new considerations. Image-guided adaptive radiation therapy (IGART) is a closed-loop treatment process that is designed to include the individual treatment information, such as patient-specific anatomic variation and delivered dose assessed during the therapy course in treatment evaluation and planning optimization. Clinical implementation of IGART requires high levels of automation in image acquisition, registration, segmentation, treatment dose construction, and adaptive planning optimization, which brings new challenges to the conventional QA program. In this article, clinical QA procedures for IGART are outlined. The discussion focuses on the dynamic or four-dimensional aspects of the IGART process, avoiding overlap with conventional QA guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Projector-Based Augmented Reality for Intuitive Intraoperative Guidance in Image-Guided 3D Interstitial Brachytherapy

Purpose: The aim of this study is to implement augmented reality in real-time image-guided interstitial brachytherapy to allow an intuitive real-time intraoperative orientation. Methods and Materials: The developed system consists of a common video projector, two high-resolution charge coupled device cameras, and an off-the-shelf notebook. The projector was used as a scanning device by projecting coded-light patterns to register the patient and superimpose the operating field with planning data and additional information in arbitrary colors. Subsequent movements of the nonfixed patient were detected by means of stereoscopically tracking passive markers attached to the patient. Results: In a first clinical study, we evaluated the whole process chain from image acquisition to data projection and determined overall accuracy with 10 patients undergoing implantation. The described method enabled the surgeon to visualize planning data on top of any preoperatively segmented and triangulated surface (skin) with direct line of sight during the operation. Furthermore, the tracking system allowed dynamic adjustment of the data to the patient's current position and therefore eliminated the need for rigid fixation. Because of soft-part displacement, we obtained an average deviation of 1.1 mm by moving the patient, whereas changing the projector's position resulted in an average deviation of 0.9 mm. Mean deviation of all needles of an implant was 1.4 mm (range, 0.3-2.7 mm). Conclusions: The developed low-cost augmented-reality system proved to be accurate and feasible in interstitial brachytherapy. The system meets clinical demands and enables intuitive real-time intraoperative orientation and monitoring of needle implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Infrared-Guided Patient Setup for Lung Cancer Patients

Purpose: To evaluate the utility of an infrared-guided patient setup (iGPS) system to reduce the uncertainties in the setup of lung cancer patients. Methods and Materials: A total of 15 patients were setup for lung irradiation using skin tattoos and lateral leveling marks. Daily electronic portal device images and iGPS marker locations were acquired and retrospectively reviewed. The iGPS-based shifts were compared with the daily electronic portal device image shifts using both the central axis iGPS marker and all five iGPS markers. For shift calculation using the five markers, rotational misalignment was included. The level of agreement between the iGPS and portal imaging to evaluate the setup was evaluated as the frequency of the shift difference in the range of 0-5 mm, 5-10 mm, and >10 mm. Results: Data were obtained for 450 treatment sessions for 15 patients. The difference in the isocenter shifts between the weekly vs. daily images was 0-5 mm in 42%, 5-10 mm in 30%, and >10 mm in 10% of the images. The shifts seen using the iGPS data were 0-5 mm in 81%, 5-10 mm in 14%, and >10 mm in 5%. Using only the central axis iGPS marker, the difference between the iGPS and portal images was <5 mm in 77%, 5-10 mm in 16%, and >10 mm in 7% in the left-right direction and 73%, 18%, and 9% in the superoinferior direction, respectively. When all five iGPS markers were used, the disagreements between the iGPS and portal image shifts >10 mm were reduced from 7% to 2% in the left-right direction and 9% to 3% in the superoinferior direction. Larger reductions were also seen (e.g., a reduction from 50% to 0% in 1 patient). Conclusion: The daily iGPS-based shifts correlated well with the daily electronic portal device-based shifts. When patient movement has nonlinear rotational components, a combination of surface markers and portal images might be particularly beneficial to improve the setup for lung cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Radiotherapy for Liver Cancer Using Respiratory-Correlated Computed Tomography and Cone-Beam Computed Tomography

Purpose: To evaluate a novel four-dimensional (4D) image-guided radiotherapy (IGRT) technique in stereotactic body RT for liver tumors. Methods and Materials: For 11 patients with 13 intrahepatic tumors, a respiratory-correlated 4D computed tomography (CT) scan was acquired at treatment planning. The target was defined using CT series reconstructed at end-inhalation and end-exhalation. The liver was delineated on these two CT series and served as a reference for image guidance. A cone-beam CT scan was acquired after patient positioning; the blurred diaphragm dome was interpreted as a probability density function showing the motion range of the liver. Manual contour matching of the liver structures from the planning 4D CT scan with the cone-beam CT scan was performed. Inter- and intrafractional uncertainties of target position and motion range were evaluated, and interobserver variability of the 4D-IGRT technique was tested. Results: The workflow of 4D-IGRT was successfully practiced in all patients. The absolute error in the liver position and error in relation to the bony anatomy was 8 {+-} 4 mm and 5 {+-} 2 mm (three-dimensional vector), respectively. Margins of 4-6 mm were calculated for compensation of the intrafractional drifts of the liver. The motion range of the diaphragm dome was reproducible within 5 mm for 11 of 13 lesions, and the interobserver variability of the 4D-IGRT technique was small (standard deviation, 1.5 mm). In 4 patients, the position of the intrahepatic lesion was directly verified using a mobile in-room CT scanner after application of intravenous contrast. Conclusion: The results of our study have shown that 4D image guidance using liver contour matching between respiratory-correlated CT and cone-beam CT scans increased the accuracy compared with stereotactic positioning and compared with IGRT without consideration of breathing motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Image Registration for Image-Guided Radiotherapy

Purpose: Newly emerged four-dimensional (4D) imaging techniques such as 4D-computed tomography (CT), 4D-cone beam CT, 4D-magnetic resonance imaging, and 4D-positron emission tomography are effective tools to reveal the spatiotemporal details of patients' anatomy. To use the 4D data acquired under different conditions or using different modalities, an algorithm for registering 4D images must be in place. We developed an automated 4D-4D registration method to take advantage of 4D information. Methods and Materials: We used 4D-4D matching to find the appropriate three-dimensional anatomy in the fixed image for each phase of the moving image and spatially register them. A search algorithm was implemented to simultaneously find the best phase and spatial match of two 4D inputs. An interpolation scheme capable of deriving an image set based on temporally adjacent three-dimensional data sets was developed to deal with the situation in which the discrete temporal points of the two inputs do not coincide or correspond. Results: In a phantom study, our technique was able to reproduce the known 'ground truth' with high spatial fidelity. The technique regenerated all deliberately introduced 'missing' three-dimensional images at different phases of the input using temporal interpolation. In the registration of gated-magnetic resonance imaging and 4D-CT, the algorithm was able to select the appropriate CT phase. The technique was also able to register 4D-CT with 4D-cone beam CT and two 4D-CT scans acquired at different times. A spatial accuracy of <3 mm was achieved in 98% of voxels in all cases. Conclusion: Automated 4D-4D registration can find the best possible spatiotemporal match between two 4D data sets and is useful for image-guided radiotherapy applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Does Image-Guided Radiotherapy Improve Toxicity Profile in Whole Pelvic-Treated High-Risk Prostate Cancer? Comparison Between IG-IMRT and IMRT

Purpose: To evaluate the impact of adding image-guided (IG) technique to intensity-modulated radiotherapy (IMRT) on dosimetric avoidance of organs at risk (OAR) and acute toxicities. Methods and Materials: A total of 25 consecutively treated patients (10 from National University Hospital and 15 from University of California San Francisco) with high-risk prostate cancer formed the study cohort. All received definitive IMRT with prophylactic nodal RT. Similar IMRT contouring and planning techniques were used at both centers. At University of California, San Francisco, intraprostatic fiducial markers were used for daily pretreatment on-line corrections (IG-IMRT). In contrast, at the National University Hospital, no fiducial markers were used (IMRT). At University of California, San Francisco, the planning target volume margins to the prostate were 2-3 mm. At the National University Hospital, they were 1 cm circumferentially, except for 0.5 cm posteriorly. The acute rectal and bladder toxicities and dosimetric endpoints to the planning target volume and organs at risk were compared. Results: The planning target volume dose coverage was not significantly different between IMRT and IG-IMRT for the prostate, seminal vesicles, and lymph nodes. The volume of rectum and bladder receiving {>=}40, {>=}60, and {>=}70 Gy were all significantly less using IG-IMRT (p <0.001). IG-IMRT yielded lower acute Radiation Therapy Oncology Group Grade 2 rectal (80% vs. 13%, p = 0.004) and bladder (60% vs. 13%, p = 0.014) toxicities. Conclusions: IG-IMRT, using daily target localization with fiducial markers, permits the use of smaller margins and correspondingly lower doses to the organs at risk, such as the rectum and bladder. These tangible gains appear to translate into lower clinically significant toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Radiotherapy for Cervix Cancer: High-Tech External Beam Therapy Versus High-Tech Brachytherapy

Purpose: Many studies comparing external-beam therapy (EBT) and brachytherapy (BT) are biased because advanced EBT is compared with conventional BT. This study compares high-tech EBT against high-tech BT. Methods and Materials: Nine patients were selected with locally advanced cervix cancer, representing typical clinical situations according to initial tumor extension and response after EBT. Patients were treated either with intracavitary, combined interstitial/intracavitary, or complex interstitial BT. Gross tumor volume, high-risk clinical target volume (CTV), intermediate-risk CTV, bladder, rectum, and sigmoid were delineated. Magnetic resonance-guided BT planning was manually optimized with respect to organ dose limits. Margins (3 and 5 mm) were added to BT CTVs to construct planning target volumes (PTVs) for EBT. Inversely planned EBT with photons (IMRT) and protons (IMPT) was challenged to deliver the highest possible doses to PTVs while respecting D{sub 1cc} and D{sub 2cc} limits from BT, assuming the same fractionation (4 x 7 Gy). The D90 for target structures and normal tissue volumes receiving fractionated doses between 3 and 7 Gy were compared. Results: High-risk CTV doses depended on the clinical situation and radiation quality. If IMRT was limited to D{sub 2cc} and D{sub 1cc} from BT, the D90 for high-risk PTV and intermediate-risk PTV was mostly lower. Volumes receiving 60 Gy (in equivalent dose in 20 Gy fractions) were approximately twice as large for IMRT compared with BT. For IMPT, this volume ratio was lower. Planning target volume doses of IMPT plans with 3-mm margins were comparable to those with BT. Gross tumor volume doses were mostly lower for both IMRT and IMPT. Conclusion: For benchmarking high-tech EBT, high-tech BT techniques have to be used. For cervix cancer boost treatments, both IMRT and IMPT seem to be inferior to advanced BT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Prostate Shifts: Review of 1870 Computed Tomography (CT) Scans Obtained During Image-Guided Radiotherapy Using CT-on-Rails for the Treatment of Prostate Cancer

Purpose: To review 1870 CT scans of interfractional prostate shift obtained during image-guided radiotherapy. Methods and Materials: A total of 1870 pretreatment CT scans were acquired with CT-on-rails, and the corresponding shift data for 329 patients with prostate cancer were analyzed. Results: Of the 1870 scans reviewed, 44% required no setup adjustments in the anterior-posterior (AP) direction, 14% had shifts of 3-5 mm, 29% had shifts of 6-10 mm, and 13% had shifts of >10 mm. In the superior-inferior direction, 81% had no adjustments, 2% had shifts of 3-5 mm, 15% had shifts of 6-10 mm, and 2% had shifts of >10 mm. In the left-right direction, 65% had no adjustment, 13% had shifts of 3-5 mm, 17% had shifts of 6-10 mm, and 5% had shifts of >10 mm. Further analysis of the first 66 consecutive patients divided into three groups according to body mass index indicates that the shift in the AP direction for the overweight subgroup was statistically larger than those for the control and obese subgroups (p < 0.05). The interfractional shift in the lateral direction for the obese group (1 SD, 5.5 mm) was significantly larger than those for the overweight and control groups (4.1 and 2.9 mm, respectively) (p < 0.001). Conclusions: These data demonstrate that there is a significantly greater shift in the AP direction than in the lateral and superior-inferior directions for the entire patient group. Overweight and obese patient groups show a significant difference from the control group in terms of prostate shift.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Spine, Carina, and Tumor as Registration Landmarks for Volumetric Image-Guided Lung Radiotherapy

Purpose: To assess the feasibility, reproducibility, and accuracy of volumetric lung image guidance using different thoracic landmarks for image registration. Methods and Materials: In 30 lung patients, four independent observers conducted automated and manual image registrations on Day 1 cone-beam computed tomography data sets using the spine, carina, and tumor (720 image registrations). The image registration was timed, and the couch displacements were recorded. The intraclass correlation was used to assess reproducibility, and the Bland-Altman analysis was used to compare the automatic and manual matching methods. Tumor coverage (accuracy) was assessed through grading the tumor position after image matching against the internal target volume and planning target volume. Results: The image-guided process took an average of 1 min for all techniques, with the exception of manual tumor matching, which took 4 min. Reproducibility was greatest for automatic carina matching (intraclass correlation, 0.90-0.93) and lowest for manual tumor matching (intraclass correlation, 0.07-0.43) in the left-right, superoinferior, and anteroposterior directions, respectively. The Bland-Altman analysis showed no significant difference between the automatic and manual registration methods. The tumor was within the internal target volume 62% and 60% of the time and was outside the internal target volume, but within the planning target volume, 38% and 40% of the time after automatic spine and automatic carina matching, respectively. Conclusion: For advanced lung cancer, the spine or carina can be used equally for cone-beam computed tomography image registration without compromising target coverage. The carina was more reproducible than the spine, but additional analysis is required to confirm its validation as a tumor surrogate. Soft-tissue registration is unsuitable at present, given the limitations in contrast resolution and the high interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Response Relationship for Image-Guided Stereotactic Body Radiotherapy of Pulmonary Tumors: Relevance of 4D Dose Calculation

Purpose: To evaluate outcome after image-guided stereotactic body radiotherapy (SBRT) for early-stage non-small-cell lung cancer (NSCLC) and pulmonary metastases. Methods and Materials: A total of 124 patients with 159 pulmonary lesions (metastases n = 118; NSCLC, n = 41; Stage IA, n = 13; Stage IB, n = 19; T3N0, n = 9) were treated with SBRT. Patients were treated with hypofractionated schemata (one to eight fractions of 6-26 Gy); biologic effective doses (BED) to the clinical target volume (CTV) were calculated based on four-dimensional (4D) dose calculation. The position of the pulmonary target was verified using volume imaging before all treatments. Results: With mean/median follow-up of 18/14 months, actuarial local control was 83% at 36 months with no difference between NSCLC and metastases. The dose to the CTV based on 4D dose calculation was closely correlated with local control: local control rates were 89% and 62% at 36 months for >100 Gy and <100 Gy BED (p = 0.0001), respectively. Actuarial freedom from regional and systemic progression was 34% at 36 months for primary NSCLC group; crude rate of regional failure was 15%. Three-year overall survival was 37% for primary NSCLC and 16% for metastases; no dose-response relationship for survival was observed. Exacerbation of comorbidities was the most frequent cause of death for primary NSCLC. Conclusions: Doses of >100 Gy BED to the CTV based on 4D dose calculation resulted in excellent local control rates. This cutoff dose is not specific to the treatment technique and protocol of our study and may serve as a general recommendation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calcifications Are Potential Surrogates for Prostate Localization in Image-Guided Radiotherapy

Purpose: To investigate the feasibility of using calcifications as surrogates for the prostate position during cone-beam computed tomography (CBCT) image-guided radiotherapy. Methods and Materials: The twice-weekly CBCT images taken during the treatment course of 4 patients were retrospectively studied for the stability of the calcifications. The geometric center of three fiducial markers was used as the reference. The planning CT images of 131 prostate patients recently treated with external beam radiotherapy at our center were reviewed to estimate the calcification occurrence rate. Analysis was conducted using the Varian Eclipse treatment planning system. Two patients were treated using prostate calcifications as the landmark in on-line registration. Both the Varian standard and the low-dose CBCT modes were used for imaging. Results: The calcifications were found to be stable during the treatment course. At the 95% confidence interval, the difference between the distance from an identified calcification to the fiducial markers on CBCT and the distance on the planning CT scans was 0.2 {+-} 2.0 mm, 0.8 {+-} 2.2 mm, and 0.4 {+-} 2.4 mm in the left-right, anteroposterior, and superoinferior direction, respectively. Of the 131 patients, 46 (35%) had well-defined calcifications either inside the prostate or near the borders. Our experience in treating the first 2 patients demonstrated that the calcifications are easily distinguished on low-dose scans and that calcification registration can be precisely performed. Conclusion: The results of our study have shown that calcifications can be reliable markers of prostate position and allow for precise image guidance with a low-imaging dose. With this approach, potentially about one-third of prostate patients could benefit from precise image guidance without the invasive use of markers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Evaluation of Positioning Verification Using Digital Tomosynthesis and Bony Anatomy and Soft Tissues for Prostate Image-Guided Radiotherapy

Purpose: To evaluate on-board digital tomosynthesis (DTS) for patient positioning vs. two-dimensional (2D) radiography and three-dimensional cone beam (CBCT). Methods and Materials: A total of 92 image sessions from 9 prostate cancer patients were analyzed. An on-board image set was registered to a corresponding reference image set. Four pairs of image sets were used: digitally reconstructed radiographs vs. on-board orthogonal paired radiographs for the 2D method, coronal-reference DTS vs. on-board coronal DTS for the coronal-DTS method, sagittal-reference DTS vs. on-board sagittal DTS for the sagittal-DTS method, and planning CT vs. CBCT for the CBCT method. The registration results were compared. Results: The systematic errors in all methods were <1 mm/1{sup o}. When registering the bony anatomy, the mean vector difference was 0.21 {+-} 0.11 cm between 2D and CBCT, 0.11 {+-} 0.08 cm between CBCT and coronal DTS, and 0.14 {+-} 0.07 cm between CBCT and sagittal DTS. The correlation between CBCT to DTS was stronger (coefficient = 0.92-0.95) than the correlation between 2D and CBCT or DTS (coefficient = 0.81-0.83). When registering the soft tissue, the mean vector difference was 0.18 {+-} 0.11 cm between CBCT and coronal DTS and 0.29 {+-} 0.17 cm between CBCT and sagittal DTS. The correlation coefficient of CBCT to sagittal DTS and to coronal DTS was 0.84 and 0.92, respectively. Conclusion: DTS could provide equivalent results to CBCT when the bony anatomy is used as landmarks for prostate image-guided radiotherapy. For soft tissue-based positioning verification, coronal DTS produced equivalent results to CBCT, but sagittal DTS alone was insufficient. DTS could allow for comparable soft tissue-based target localization with faster scanning time and a lower imaging dose compared with CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Dose From Kilovoltage Cone Beam Computed Tomography in an Image-Guided Radiotherapy Procedure

Purpose: Image-guided radiation therapy has emerged as the new paradigm in radiotherapy. This work is to provide detailed information concerning the additional imaging doses to patients' radiosensitive organs from a kilovoltage cone beam computed tomography (kV CBCT) scan procedure. Methods and Materials: The Vanderbilt-Monte-Carlo-Beam-Calibration (VMCBC; Vanderbilt University, Nashville, TN) algorithm was used to calculate radiation dose to organs resulting from a kV CBCT imaging guidance procedure. Eight patients, including 3 pediatric and 5 adult patients, were investigated. The CBCT scans in both full- and half-fan modes were studied. Results: For a head-and-neck scan in half-fan mode, dose-volume histogram analyses show mean doses of 7 and 8 cGy to the eyes, 5 and 6 cGy to the spinal cord, 5 and 6 cGy to the brain, and 18 and 23 cGy to the cervical vertebrae for an adult and a 29-month-old child, respectively. The dose from a scan in full-fan mode is 10-20% lower than that in half-fan mode. For an abdominal scan, mean doses are 3 and 7 cGy to prostate and 7 and 17 cGy to femoral heads for a large adult patient and a 31-month-old pediatric patient, respectively. Conclusions: Doses to radiosensitive organs can total 300 cGy accrued over an entire treatment course if kV CBCT scans are acquired daily. These findings provide needed data for clinicians to make informed decisions concerning additional imaging doses. The dose to bone is two to four times greater than dose to soft tissue for kV x-rays, which should be considered, especially for pediatric patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Volume Histogram Parameters and Local Tumor Control in Magnetic Resonance Image-Guided Cervical Cancer Brachytherapy

Purpose: To investigate the value of dose-volume histogram (DVH) parameters for predicting local control in magnetic resonance (MR) image-guided brachytherapy (IGBT) for patients with cervical cancer. Methods and Materials: Our study population consists of 141 patients with cervical cancer (Stages IB-IVA) treated with 45-50 Gy external beam radiotherapy plus four times 7 Gy IGBT with or without cisplatin. Gross tumor volume (GTV), high-risk clinical target volume (HRCTV), and intermediate-risk clinical target volume (IRCTV) were contoured, and DVH parameters (minimum dose delivered to 90% of the volume of interest [D90] and D100) were assessed. Doses were converted to the equivalent dose in 2 Gy (EQD2) by applying the linear quadratic model ({alpha}/{beta} = 10 Gy). Groups were defined for patients with or without local recurrence (LR) in the true pelvis for tumor size at diagnosis (GTV at diagnosis [GTVD] of 2-5 cm (Group 1) or greater than 5 cm (Group 2) and for tumor size response at IGBT (HRCTV) of 2-5 cm (Group 2a) or greater than 5 cm (Group 2b). Results: Eighteen LRs were observed. The most important DVH parameters correlated with LR were the D90 and D100 for HRCTV. Mean D90 and D100 values for HRCTV were 86 {+-} 16 and 65 {+-} 10 Gy, respectively. The D90 for HRCTV greater than 87 Gy resulted in an LR incidence of 4% (3 of 68) compared with 20% (15 of 73) for D90 less than 87 Gy. The effect was most pronounced in the tumor group (Group 2b). Conclusions: We showed an increase in local control in IGBT in patients with cervical cancer with the dose delivered, which can be expressed by the D90 and D100 for HRCTV. Local control rates greater than 95% can be achieved if the D90 (EQD2) for HRCTV is 87 Gy or greater.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Study of LDR (Manchester System) and HDR Image-guided Conformal Brachytherapy of Cervical Cancer: Patterns of Failure, Late Complications, and Survival

Purpose: To compare patterns of failure, late toxicities, and survival in locally advanced cervical cancer patients treated by either low-dose-rate (LDR) or conformal high-dose-rate (HDRc) brachytherapy as a part of curative radiotherapy. Materials and Methods: A retrospective comparative study of 217 advanced cervix cancer patients was conducted; 90 of these patients received LDR and 127 received HDRc brachytherapy. All patients were staged using International Federation of Gynecology and Obstetrics (FIGO) rules, had pretreatment magnetic resonance imaging (MRI), and were treated with concurrent cisplatin chemoradiotherapy. Both groups matched for FIGO stage, MRI tumor volume, and uterine invasion status. Results: Local and pelvic failures were similar 12-13% and 14% both in both groups. Abdominal and systemic failures in LDR group were 21% and 24%, whereas corresponding failures in HDRc group were 20% and 24%. Sixty-eight percent (87/127) of patients treated by HDRc remained asymptomatic, whereas 42% (38/90) of patients were asymptomatic from the bowel and bladder symptoms after treatment with LDR. The 5-year OS rate was 60% (SE = 4%). The 5-year failure-free survival rate was 55% (SE = 3%). There was no significant difference between the groups. Conclusions: Image-guided HDRc planning led to a large decrease in late radiation effects in patients treated by HDRc. Patterns of failure and survival were similar in patients treated either by LDR or HDRc.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Strategies for Biologic Image-Guided Dose Escalation: A Review

There is increasing interest in how to incorporate functional and molecular information obtained by noninvasive, three-dimensional tumor imaging into radiotherapy. The key issues are to identify radioresistant regions that can be targeted for dose escalation, and to develop radiation dose prescription and delivery strategies providing optimal treatment for the individual patient. In the present work, we review the proposed strategies for biologic image-guided dose escalation with intensity-modulated radiation therapy. Biologic imaging modalities and the derived images are discussed, as are methods for target volume delineation. Different dose escalation strategies and techniques for treatment delivery and treatment plan evaluation are also addressed. Furthermore, we consider the need for response monitoring during treatment. We conclude with a summary of the current status of biologic image-based dose escalation and of areas where further work is needed for this strategy to become incorporated into clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Frameless Image-Guided Intracranial Stereotactic Radiosurgery: Clinical Outcomes for Brain Metastases

Purpose: After preclinical investigations confirming the accuracy of target localization by frameless image-guided radiosurgery, we report the clinical outcomes of patients with brain metastases who underwent frameless radiosurgery. Methods and Materials: Between 2005 and 2006, 53 patients underwent frameless stereotactic radiosurgery using a linear accelerator equipped with on-board image guidance for the treatment of 158 brain metastases. The radiation doses were delivered in a single fraction (dose range, 12-22 Gy; median, 18). Patients were followed with magnetic resonance imaging scans at 2-3-month intervals. Progression-free survival was the primary study endpoint. Results: With a median follow-up of 38 weeks (range, 14-112), the overall survival rate was 70% at 6 months, 44% at 1 year, 29% at 18 months, and 16% at 24 months. Local control was achieved in 90% of 168 treated lesions at 6 months, 80% at 12 months, 78% at 18 months, and 78% at 24 months. Local control tended to be improved in lesions treated with {>=}18 Gy and for lesions <0.2 cm{sup 3}. Adverse events occurred in 5 patients (9.6%). No evidence of imaging changes on post-stereotactic radiosurgery scans was found to suggest mistargeting of a radiation isocenter. Conclusion: The clinical outcomes after frameless stereotactic radiosurgery were comparable to those after frame-based radiosurgery techniques. Given its significant advantages in terms of patient comfort, ability to use fractionated treatment regimens, and convenience in scheduling of personnel and equipment resources, frameless radiosurgery will likely become a common technique for intracranial radiosurgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗