Human factors in aviation operations: The hearback problem

This report covers a study of ASRS reports wherein ATC controllers failed to monitor adequately (hearback) incorrect readbacks of ATC clearances. A total of 417 reports received over a period of 29 months from April 1981 through July 1983 comprised the study data set. Factors examined were: the reasons for a flight crew's getting clearances incorrectly, the operating factors that caused controllers to mishear or not hear the correct readbacks, and consequences of the various types of hearback misses. The principle conclusion of the study takes the form of a precaution to flight crews that a controller's not challenging a readback does not necessariliy mean the readback is correct and that flight crews must explicitly question any doubtful or unusual aspects of clearances rather than depending on controllers to detect readback errors.

Monan, William P.↗

Combined mixed approach algorithm for in-line phase-contrast x-ray imaging

Purpose: In the past decade, phase-contrast imaging (PCI) has been applied to study different kinds of tissues and human body parts, with an increased improvement of the image quality with respect to simple absorption radiography. A technique closely related to PCI is phase-retrieval imaging (PRI). Indeed, PCI is an imaging modality thought to enhance the total contrast of the images through the phase shift introduced by the object (human body part); PRI is a mathematical technique to extract the quantitative phase-shift map from PCI. A new phase-retrieval algorithm for the in-line phase-contrast x-ray imaging is here proposed. Methods: The proposed algorithm is based on a mixed transfer-function and transport-of-intensity approach (MA) and it requires, at most, an initial approximate estimate of the average phase shift introduced by the object as prior knowledge. The accuracy in the initial estimate determines the convergence speed of the algorithm. The proposed algorithm retrieves both the object phase and its complex conjugate in a combined MA (CMA). Results: Although slightly less computationally effective with respect to other mixed-approach algorithms, as two phases have to be retrieved, the results obtained by the CMA on simulated data have shown that the obtained reconstructed phase maps are characterized by particularly low normalized mean square errors. The authors have also tested the CMA on noisy experimental phase-contrast data obtained by a suitable weakly absorbing sample consisting of a grid of submillimetric nylon fibers as well as on a strongly absorbing object made of a 0.03 mm thick lead x-ray resolution star pattern. The CMA has shown a good efficiency in recovering phase information, also in presence of noisy data, characterized by peak-to-peak signal-to-noise ratios down to a few dBs, showing the possibility to enhance with phase radiography the signal-to-noise ratio for features in the submillimetric scale with respect to the attenuation-based imaging. Conclusions: It has been shown that phase-retrieved radiographies can be used both to have quantitative phase information about soft tissues, complementary to the attenuation information, and to enhance the visibility of details inside soft tissues, with higher efficiency with respect to phase radiography.

60 APPLIED LIFE SCIENCES↗

Uncovering Where Compensating Errors Could Hide in ENDF/B-VIII.0

Unconstrained physics spaces between two or more nuclear data observables in a library occur when their values can be simultaneously adjusted without violating the uncertainties in either differential information or simulations of relevant integral experiments. Differential data are often too imprecise to fully bound all nuclear data observables of interest for application simulations. Integral data are simulated with combinations of nuclear data so that an error in one observable may be hidden by a counterbalancing error in another. In this manner compensating errors may lurk within nuclear data libraries and these errors have the potential to undermine the predictive power of neutron transport simulations, particularly in situations where there is no conclusive validation experiment that resembles the application of interest. The EUCLID project (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) developed a preliminary workflow to identify these unconstrained physics spaces by bringing together results from a large collection of integral experiments with their simulated counter-parts as well as differential information that have a one-to-one correspondence to nuclear data. This wealth of information is processed by machine learning tools for subsequent refinement by human experts. Here, we show how the EUCLID work-flow is executed by applying it first to 239 Pu and then to 9 Be nuclear data in ENDF/B-VIII.0.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Management of hypophosphatemia

The etiology, clinical presentation, and management of hypophosphatemia are reviewed. Phosphorus is a major intracellular anion and plays an important role in many biochemical pathways relating to normal physiologic functions. Approximately 60 to 90% of the 1 to 1.5 g of daily dietary phosphorus intake is absorbed, and of that amount, about two thirds is excreted in the urine. The overall incidence of hypophosphatemia is about 2 to 3% of all hospitalized patients. Factors associated with hypophosphatemia include phosphate-binding antacid therapy, nasogastric suction, liver disease, sepsis, alcoholism, and acidosis associated with diabetic ketoacidosis. Patients receiving parenteral nutrient solutions were also at higher risk for hypophosphatemia before the routine supplementation of these formulations with phosphate. Patients with hypophosphatemia may be asymptomatic or may experience weakness, malaise, anorexia, bone pain, and respiratory arrest. The major systems involved include the neuromuscular, hematologic, and skeletal systems. Phosphorus-containing products used to treat hypophosphatemia are a combination of monobasic and dibasic phosphate salts. Therefore, it is essential to calculate doses in millimoles rather than milligrams or milliequivalents to more accurately reflect the phosphorus concentration and to avoid potentially serious dosage errors. Normal daily requirements are readily maintained by dietary sources of phosphorus such as milk products or may be supplemented by phosphate-containing products administered orally or intravenously. Since phosphorus is a key factor in many organ systems, it is essential to monitor serum phosphorus concentrations in patients at risk for hypophosphatemia.

Review, Tutorial↗

In-situ sampling of a large-scale particle simulation for interactive visualization and analysis

We propose storing a random sampling of data from large scale particle simulations, such as the Roadrunner Universe MC{sup 3} cosmological simulation, to be used for interactive post-analysis and visualization. Simulation data generation rates will continue to be far greater than storage bandwidth rates and other limiting technologies by many orders of magnitude. This implies that only a very small fraction of data generated by the simulation can ever be stored and subsequently post-analyzed. The limiting technology in this situation is analogous to the problem in many population surveys: there aren't enough human resources to query a large population. To cope with the lack of resources, statistical sampling techniques are used to create a representative data set of a large population. Mirroring that situation, we propose to store a simulation-time random sampling of the particle data to cope with the bOlllenecks and support interactive, exploratory post-analysis. The particle samples are immediately stored in a level-ol-detail format for post-visualization and analysis, which amortizes the cost of post-processing for interactive visualization. Additionally, we incorporate a system for recording and visualizing sample approximation error information for confidence and importance highlighting.

97 MATHEMATICS AND COMPUTING↗

Uncovering Where Compensating Errors Could Hide in ENDF/B-VIII.0

Unconstrained physics spaces between two or more nuclear data observables in a library occur when their values can be simultaneously adjusted without violating the uncertainties in either differential information or simulations of relevant integral experiments. Differential data are often too imprecise to fully bound all nuclear data observables of interest for application simulations. Integral data are simulated with combinations of nuclear data so that an error in one observable may be hidden by a counterbalancing error in another. In this manner compensating errors may lurk within nuclear data libraries and these errors have the potential to undermine the predictive power of neutron transport simulations, particularly in situations where there is no conclusive validation experiment that resembles the application of interest. The EUCLID project (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) developed a preliminary workflow to identify these unconstrained physics spaces by bringing together results from a large collection of integral experiments with their simulated counter-parts as well as differential information that have a one-to-one correspondence to nuclear data. This wealth of information is processed by machine learning tools for subsequent refinement by human experts. Here, we show how the EUCLID work-flow is executed by applying it first to 239 Pu and then to 9 Be nuclear data in ENDF/B-VIII.0.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Efforts to enhance reproducibility in a human performance research project

Background: Ensuring the validity of results from funded programs is a critical concern for agencies that sponsor biological research. In recent years, the open science movement has sought to promote reproducibility by encouraging sharing not only of finished manuscripts but also of data and code supporting their findings. While these innovations have lent support to third-party efforts to replicate calculations underlying key results in the scientific literature, fields of inquiry where privacy considerations or other sensitivities preclude the broad distribution of raw data or analysis may require a more targeted approach to promote the quality of research output. Methods: We describe efforts oriented toward this goal that were implemented in one human performance research program, Measuring Biological Aptitude, organized by the Defense Advanced Research Project Agency's Biological Technologies Office. Our team implemented a four-pronged independent verification and validation (IV&V) strategy including 1) a centralized data storage and exchange platform, 2) quality assurance and quality control (QA/QC) of data collection, 3) test and evaluation of performer models, and 4) an archival software and data repository. Results: Our IV&V plan was carried out with assistance from both the funding agency and participating teams of researchers. QA/QC of data acquisition aided in process improvement and the flagging of experimental errors. Holdout validation set tests provided an independent gauge of model performance. Conclusions: In circumstances that do not support a fully open approach to scientific criticism, standing up independent teams to cross-check and validate the results generated by primary investigators can be an important tool to promote reproducibility of results.

59 BASIC BIOLOGICAL SCIENCES↗

WOBBLE: A Proposed Mission to Characterize Past and Present Water on Mars

WOBBLE ("Water Observations from a Balloon Borne Light Explorer") is a mission concept study for a small robotic probe to explore Mars and to accomplish a scientific mission compatible with the goals of the NASA Code S enterprise. The detection of past or present water is a crucial goal for Mars exploration, representing a cross-cutting science theme relevant to past or extant life, climate history, sample return missions and eventual human exploration. The WOBBLE mission concept was developed to study evidence of water using in-situ detection methods. The features on Mars most suited to this investigation are the gullies identified by Malin and Edgett as evidence for recent, near-surface runoff of liquid water. These features are typically located on the inside face of crater rims, where the local slope angle is at or near the angle of repose. This makes the terrain difficult or impossible to access with conventional wheeled rover technology. Combined with the small size of the gullies in relation to a standard landing error ellipse, scientific investigation of these features requires a new approach to surface mobility. WOBBLE uses a low-altitude balloon-borne platform to traverse the surface from the landing site, to the investigation site, and then rise up the slope to investigate the regions of interest at close range. Of the mobility technologies available for near-term Mars exploration, only a balloon platform is capable of a well targeted, detailed sampling of the gully regions over periods of days or more. The science approach embodied in WOBBLE is two-pronged, designed to investigate both the historical evidence of liquid water utilizing high-resolution geomorphology and the characterization of mineral deposits, and present subsurface liquid water using radar sounding techniques. The WOBBLE balloon is a high-pressure hydrogen gas design, 24 meters in diameter and lifting a total payload of 130 kg, including a high-resolution camera/IR imager, Raman spectrometer, and a ground penetrating radar (GPR) sounder. The stowed balloon and payload are designed to fit within the current airbag delivery system being built for the Mars Exploration Rovers. Characterization of local meteorological conditions and wind is made over the initial sols following landing and before balloon inflation. Following balloon inflation and launch, a controlled, targeted approach toward the identified regions of interest is made in a series of several low-altitude "hops," with the balloon tethered to the ground between the hop intervals. A "snake" system is used to control the altitude to a few tens of meters above the local ground level. Enroute to the target gully, GPR soundings and Raman spectroscopy measurements study past or present water, while continued camera bearings and meteorological measurements refine the next "hop" trajectory. Once at the gully/outflow region, GPR and Raman soundings continue while the camera obtains detailed, approx. 0.5 cm images for geomorphology studies. The WOBBLE concept is applicable to Mars Scout, Mars Surveyor, or Discovery class missions.

Udrea, Bogdan↗

Thrust Vector Control for Nuclear Thermal Rockets

Future space missions may use Nuclear Thermal Rocket (NTR) stages for human and cargo missions to Mars and other destinations. The vehicles are likely to require engine thrust vector control (TVC) to maintain desired flight trajectories. This paper explores requirements and concepts for TVC systems for representative NTR missions. Requirements for TVC systems were derived using 6 degree-of-freedom models of NTR vehicles. Various flight scenarios were evaluated to determine vehicle attitude control needs and to determine the applicability of TVC. Outputs from the models yielded key characteristics including engine gimbal angles, gimbal rates and gimbal actuator power. Additional factors such as engine thrust variability and engine thrust alignment errors were examined for impacts to gimbal requirements. Various technologies are surveyed for TVC systems for the NTR applications. A key factor in technology selection is the unique radiation environment present in NTR stages. Other considerations including mission duration and thermal environments influence the selection of optimal TVC technologies. Candidate technologies are compared to see which technologies, or combinations of technologies best fit the requirements for selected NTR missions. Representative TVC systems are proposed and key properties such as mass and power requirements are defined. The outputs from this effort can be used to refine NTR system sizing models, providing higher fidelity definition for TVC systems for future studies.

Ensworth, Clinton B. F.↗

Geant4 simulation for a study of a possible use of carbon ions pencil beam for the treatment of ocular melanomas with the active scanning system at CNAO Centre

The aim of this work is to validate the Geant4 application reproducing the CNAO (National Centre for Oncological Hadrontherapy) beamline and to study of a possible use of carbon ion pencil beams for the treatment of ocular melanomas at the CNAO Centre. The promising aspect of carbon ions radiotherapy for the treatment of this disease lies in its superior relative radiobiological effectiveness (RBE). The Monte Carlo Geant4 toolkit is used to simulate the complete CNAO extraction beamline, with the active and passive components along it. A human eye modeled detector, including a realistic target tumor volume, is used as target. Cross check with previous studies at CNAO using protons allows comparisons on possible benefits on using such a technique with respect to proton beams. Before the eye-detector irradiation a validation of the Geant4 simulation with CNAO experimental data is carried out with both carbon ions and protons. Important beam parameters such as the transverse FWHM and scanned radiation field 's uniformity are tested within the simulation and compared with experimental measurements at CNAO Centre. The physical processes involved in secondary particles generation by carbon ions and protons in the eye-detector are reproduced to take into account the additional dose to the primary beam given to irradiated eye's tissues. A study of beam shaping is carried out to produce a uniform 3D dose distribution (shaped on the tumor) by the use of a spread out Bragg peak. The eye-detector is then irradiated through a two dimensional transverse beam scan at different depths. In the use case the eye-detector is rotated of an angle of 40 deg. in the vertical direction, in order to mis-align the tumor from healthy tissues in front of it. The treatment uniformity on the tumor in the eye-detector is tested. For a more quantitative description of the deposited dose in the eye-detector and for the evaluation of the ratio between the dose deposited in the tumor and the other eye components, proton and carbon DVHs (Dose Volume Histograms) are compared. A high statistics simulated sample is used to minimize statistical errors. In the simulation a new particle generation method is developed in order to reproduce the experimental treatment plan by importing the DICOM RT-PLAN file, which contains all the information on the irradiation geometries and sequences (treatment plan parameters). Conclusions Even further validations must be done, the good results so far obtained by this work point out and confirm the possibility of using carbon ions delivered with active scanning beams to treat the ocular melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PDF Entity Annotation Tool (PEAT)

While different text mining approaches – including the use of Artificial Intelligence (AI) and other machine based methods - continue to expand at a rapid pace, the tools used by researchers to create the labeled datasets required for training, modeling, and evaluation remain rudimentary. Labeled datasets contain the target attributes the machine is going to learn; for example, training an algorithm to delineate between images of a car or truck would generally require a set of images with a quantitative description of the underlying features of each vehicle type. Development of labeled textual data that can be used to build natural language machine learning models for scientific literature is not currently integrated into existing manual workflows used by domain experts. Published literature is rich with important information, such as different types of embedded text, plots, and tables that can all be used as inputs to train ML/natural language processing (NLP) models, when extracted and prepared in machine readable formats. Currently, both normalized data extraction of use to domain experts and extraction to support development of ML/NLP models are labor intensive and cumbersome manual processes. Automatic extraction of data and information from formats such as PDFs that are optimized for layout and human readability, not machine readability. The PDF (Portable Document Format) Entity Annotation Tool (PEAT) was developed with the goal of allowing users to annotate publications within their current print format, while also allowing those annotations to be captured in a machine-readable format. One of the main issues with traditional annotation tools is that they require transforming the PDF into plain text to facilitate the annotation process. While doing so lessens the technical challenges of annotating data, the user loses all structure and provenance that was inherent in the underlying PDF. Also, textual data extraction from PDFs can be an error prone process. Challenges include identifying sequential blocks of text and a multitude of document formats (multiple columns, font encodings, etc.). As a result of these challenges, using existing tools for development of NLP/ML models directly from PDFs is difficult because the generated outputs are not interoperable. We created a system that allows annotations to be completed on the original PDF document structure, with no plain text extraction. The result is an application that allows for easier and more accurate annotations. In addition, by including a feature that grants the user the ability to easily create a schema, we have developed a system that can be used to annotate text for different domain-centric schemas of relevance to subject matter experts. Different knowledge domains require distinct schemas and annotation tags to support machine learning.

97 MATHEMATICS AND COMPUTING↗

TH-E-17A-04: Geometric Validation of K-Space Self-Gated 4D-MRI Vs. 4D-CT Using A Respiratory Motion Phantom

Purpose: 4D-CT is often limited by motion artifacts, low temporal resolution, and poor phase-based target definition. We recently developed a novel k-space self-gated 4D-MRI technique with high spatial and temporal resolution. The goal here is to geometrically validate 4D-MRI using a MRI-CT compatible respiratory motion phantom and comparison to 4D-CT. Methods: 4D-MRI was acquired using 3T spoiled gradient echo-based 3D projection sequences. Respiratory phases were resolved using self-gated k-space lines as the motion surrogate. Images were reconstructed into 10 temporal bins with 1.56×1.56×1.56mm3. A MRI-CT compatible phantom was designed with a 23mm diameter ball target filled with highconcentration gadolinium(Gd) gel embedded in a 35×40×63mm3 plastic box stabilized with low-concentration Gd gel. The whole phantom was driven by an air pump. Human respiratory motion was mimicked using the controller from a commercial dynamic phantom (RSD). Four breathing settings (rates/depths: 10s/20mm, 6s/15mm, 4s/10mm, 3s/7mm) were scanned with 4D-MRI and 4D-CT (slice thickness 1.25mm). Motion ground-truth was obtained from input signals and real-time video recordings. Reconstructed images were imported into Eclipse(Varian) for target contouring. Volumes and target positions were compared with ground-truth. Initial human study was investigated on a liver patient. Results: 4D-MRI and 4D-CT scans for the different breathing cycles were reconstructed with 10 phases. Target volume in each phase was measured for both 4D-CT and 4D-MRI. Volume percentage difference for the 6.37ml target ranged from 6.67±5.33 to 11.63±5.57 for 4D-CT and from 1.47±0.52 to 2.12±1.60 for 4D-MRI. The Mann-Whitney U-test shows the 4D-MRI is significantly superior to 4D-CT (p=0.021) for phase-based target definition. Centroid motion error ranges were 1.35–1.25mm (4D-CT), and 0.31–0.12mm (4D-MRI). Conclusion: The k-space self-gated 4D-MRI we recently developed can accurately determine phase-based target volume while avoiding typical motion artifacts found in 4D-CT, and is being further studied for use in GI targeting and motion management. This work supported in part by grant 1R03CA173273-01.

60 APPLIED LIFE SCIENCES↗

Robust Fault Detection Using Robust Z1 Estimation and Fuzzy Logic

This research considers the application of robust Z(sub 1), estimation in conjunction with fuzzy logic to robust fault detection for an aircraft fight control system. It begins with the development of robust Z(sub 1) estimators based on multiplier theory and then develops a fixed threshold approach to fault detection (FD). It then considers the use of fuzzy logic for robust residual evaluation and FD. Due to modeling errors and unmeasurable disturbances, it is difficult to distinguish between the effects of an actual fault and those caused by uncertainty and disturbance. Hence, it is the aim of a robust FD system to be sensitive to faults while remaining insensitive to uncertainty and disturbances. While fixed thresholds only allow a decision on whether a fault has or has not occurred, it is more valuable to have the residual evaluation lead to a conclusion related to the degree of, or probability of, a fault. Fuzzy logic is a viable means of determining the degree of a fault and allows the introduction of human observations that may not be incorporated in the rigorous threshold theory. Hence, fuzzy logic can provide a more reliable and informative fault detection process. Using an aircraft flight control system, the results of FD using robust Z(sub 1) estimation with a fixed threshold are demonstrated. FD that combines robust Z(sub 1) estimation and fuzzy logic is also demonstrated. It is seen that combining the robust estimator with fuzzy logic proves to be advantageous in increasing the sensitivity to smaller faults while remaining insensitive to uncertainty and disturbances.

Curry, Tramone↗

Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters

Near-infrared spectroscopy (NIRS) can be used to noninvasively measure changes in the concentrations of oxy- and deoxyhemoglobin in tissue. We have previously shown that while global changes can be reliably measured, focal changes can produce erroneous estimates of concentration changes (NeuroImage 13 (2001), 76). Here, we describe four separate sources for systematic error in the calculation of focal hemoglobin changes from NIRS data and use experimental methods and Monte Carlo simulations to examine the importance and mitigation methods of each. The sources of error are: (1). the absolute magnitudes and relative differences in pathlength factors as a function of wavelength, (2). the location and spatial extent of the absorption change with respect to the optical probe, (3). possible differences in the spatial distribution of hemoglobin species, and (4). the potential for simultaneous monitoring of multiple regions of activation. We found wavelength selection and optode placement to be important variables in minimizing such errors, and our findings indicate that appropriate experimental procedures could reduce each of these errors to a small fraction (<10%) of the observed concentration changes.

Non-NASA Center↗

The relationship between perceived length and egocentric location in Muller-Lyer figures with one versus two chevrons

We examined the apparent dissociation of perceived length and perceived position with respect to the Muller-Lyer (M-L) illusion. With the traditional (two-chevron) figure, participants made accurate open-loop pointing responses at the endpoints of the shaft, despite the presence of a strong length illusion. This apparently non-Euclidean outcome replicated that of Mack, Heuer, Villardi, and Chambers (1985) and Gillam and Chambers (1985) and contradicts any theory of the M-L illusion in which mislocalization of shaft endpoints plays a role. However, when one of the chevrons was removed, a constant pointing error occurred in the predicted direction, as well as a strong length illusion. Thus, with one-chevron stimuli, perceived length and location were no longer completely dissociated. We speculated that the presence of two opposing chevrons suppresses the mislocalizing effects of a single chevron, especially for figures with relatively short shafts.

NASA Center ARC↗

Sitting in the Pilot's Seat; Optimizing Human-Systems Interfaces for Unmanned Aerial Vehicles

One of the pilot-machine interfaces (the forward viewing camera display) for an Unmanned Aerial Vehicle called the DROID (Dryden Remotely Operated Integrated Drone) will be analyzed for optimization. The goal is to create a visual display for the pilot that as closely resembles an out-the-window view as possible. There are currently no standard guidelines for designing pilot-machine interfaces for UAVs. Typically, UAV camera views have a narrow field, which limits the situational awareness (SA) of the pilot. Also, at this time, pilot-UAV interfaces often use displays that have a diagonal length of around 20". Using a small display may result in a distorted and disproportional view for UAV pilots. Making use of a larger display and a camera lens with a wider field of view may minimize the occurrences of pilot error associated with the inability to see "out the window" as in a manned airplane. It is predicted that the pilot will have a less distorted view of the DROID s surroundings, quicker response times and more stable vehicle control. If the experimental results validate this concept, other UAV pilot-machine interfaces will be improved with this design methodology.

Queen, Steven M.↗

Evaluation of Visualization Software

Visualization software is widely used in scientific and engineering research. But computed visualizations can be very misleading, and the errors are easy to miss. We feel that the software producing the visualizations must be thoroughly evaluated and the evaluation process as well as the results must be made available. Testing and evaluation of visualization software is not a trivial problem. Several methods used in testing other software are helpful, but these methods are (apparently) often not used. When they are used, the description and results are generally not available to the end user. Additional evaluation methods specific to visualization must also be developed. We present several useful approaches to evaluation, ranging from numerical analysis of mathematical portions of algorithms to measurement of human performance while using visualization systems. Along with this brief survey, we present arguments for the importance of evaluations and discussions of appropriate use of some methods.

Globus, Al↗

Quantification of Trace Chemicals Using Vehicle Cabin Atmosphere Monitor

A system to monitor the concentrations of trace chemicals in cabin atmosphere is one of the most critical components in long-duration human flight missions. The Vehicle Cabin Atmosphere Monitor (VCAM) is a miniature gas chromatograph mass spectrometer system to be used to detect and quantify trace chemicals in the International Space Station. We developed an autonomous computational process to quantify trace chemicals for use in VCAM. The process involves the design of a measured signal quantification scheme, the construction of concentration curves (i.e. the relationship between concentration and ion count measured by VCAM), the decision rule of applying high- or low-gain concentration curves, and the detection of saturation, low-signals, and outliers. When the developed quantification process is applied, the average errors of concentration for most of trace chemicals are found to be between 14% and 66%.

Lee, Seungwon↗