Search NASA⌕ Search

SEARCH · Search NASA

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Detecting Low Surface Brightness Galaxies with Mask R-CNN

Low surface brightness galaxies (LSBGs), galaxies that are fainter than the dark night sky, are famously difficult to detect. However, studies of these galaxies are essential to improve our understanding of the formation and evolution of low-mass galaxies. In this work, we train a deep learning model using the Mask R-CNN framework on a set of simulated LSBGs inserted into images from the Dark Energy Survey (DES) Data Release 2 (DR2). This deep learning model is combined with several conventional image pre-processing steps to develop a pipeline for the detection of LSBGs. We apply this pipeline to the full DES DR2 coadd image dataset, and preliminary results show the detection of 22 large, high-quality LSBG candidates that went undetected by conventional algorithms. Furthermore, we find that Galactic cirrus represents the largest contaminant in our resulting candidate list.

Levy, Caleb↗

Simulation based inference with domain adaptation for strong gravitational lensing

Simulation based inference leverages machine learning to carry out Bayesian inference in systems with intractable likelihoods. However, transitioning a network trained on simulated data to real data runs the risk of encountering domain shift, leading to performance losses. We attempt to implement domain adaptation into the sbi neural posterior estimation framework using the Maximum Mean Discrepancy as an additional network loss, using masked autoregressive fow (MAF) as our density estimator. We test the network on a set of 400,000 simulated strong gravitational lensing images generated using deeplenstronomy. The source domain is defined as low noise whereas the target domain has a noise profile sampled from experimentally derived DES survey conditions. We find that SBI appears robust against small changes in the data with similar performance on source and target. Moreover, while DA does lead to performance improvements, they are marginal at 6% less inference error.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Discrete-Element and Material-Point Method (DEM and MPM) Based Solvers for Sustainable Technologies

We present the use of discrete element method (DEM) and material point method (MPM) in three relevant green technology applications that include biomass feedstock handling, lithium-ion battery manufacturing, and high-pressure reverse osmosis. Our open-source DEM and MPM solvers are developed using performance portable grid and particle management library, AMReX, thus enabling superior performance on NVIDIA and AMD GPUs with > 100 million particles. Our DEM solver resolves the motion of individual particles in a granular system and includes a bonded sphere method for modeling non-spherical particles along with Hertzian and liquid bridge-based contact models. We simulate highly variable biomass feedstock flows in large-scale hoppers for biofuel production and electrode calendering in battery manufacturing using DEM. Our simulations predict flow blockage in large scale biomass hoppers and electrode microstructure variations, thus providing valuable information for biofuel and battery manufacturers, respectively. The second half of the talk will be on MPM and its application towards pore resolved simulations of reverse osmosis membranes under compressive loads. We present a validation study of our MPM simulations with membrane microscopy imaging thus providing useful insights on membrane stability under high pressure conditions. We also present a spectral stability analysis of using linear hat, quadratic and cubic spline basis in MPM indicating regions of numerical stability.

BIOMASS FUELS,MATHEMATICS AND COMPUTING↗

Experimental Studies of Nonlinear Integrable Optics with Elliptic Potentials

The stable transport of charged particle beams is the core challenge in designing and operating accelerators. The current paradigm for transverse focusing is based on quadrupole and dipole elements, described as a linear integrable Hamiltonian by Courant and Snyder. The operational limits of high intensity accelerators are often determined by collective instabilities within the beam. Nonlinear elements may be added to suppress certain forms of these collective effects, but restrict the range of stable trajectories. These shortcomings motivate extending to a nonlinear integrable system which can offer the benefits of suppressing collective instabilities without limiting the stable trajectories. Danilov and Nagaitsev proposed a novel nonlinear integrable system with elliptical potentials, which could be implemented as magnetic elements in an accelerator. Such a system has been implemented for practical verification in the integrable optics test accelerator (IOTA), a small storage ring constructed for beam dynamics studies. Electron beam studies in IOTA treat the low-emittance beam as a macroparticle for detailed probing of the expected single particle dynamics. This dissertation details new measurements of the nonlinear integrable system relevant for practical implementation. Turn-by-turn measurements of the kicked beam responses are used for phase space reconstruction and analysis of the predicted nonlinear dynamics. The stability and aperture for various nonlinear configurations are measured with beam losses. Amplitude dependent detuning, a core figure of merit for suppressing instabilities, is measured and compared with high fidelity particle tracking simulations. The synchrotron radiation images of circulating beam allow direct measurements of the topology and lifetime in configurations where nonlinear focusing terms dominate.

Wieland, John [Michigan U.] (ORCID:000000028971852↗

Toward Complete Merger Identification at Cosmic Noon with Deep Learning

As we enter the era of large imaging surveys such as $\textit{Roman}$, Rubin, and $\textit{Euclid}$, a deeper understanding of potential biases and selection effects in optical astronomical catalogs created with the use of ML-based methods is paramount. This work focuses on a deeper understanding of the performance and limitations of deep learning-based classifiers as tools for galaxy merger identification. We train a ResNet18 model on mock Hubble Space Telescope CANDELS images from the IllustrisTNG50 simulation. Our focus is on a more challenging classification of galaxy mergers and nonmergers at higher redshifts $1

Schechter, Aimee [Colorado U.] (ORCID:000000017120↗

Analytic variance estimates of Swank and Fano factors

Purpose: Variance estimates for detector energy resolution metrics can be used as stopping criteria in Monte Carlo simulations for the purpose of ensuring a small uncertainty of those metrics and for the design of variance reduction techniques. Methods: The authors derive an estimate for the variance of two energy resolution metrics, the Swank factor and the Fano factor, in terms of statistical moments that can be accumulated without significant computational overhead. The authors examine the accuracy of these two estimators and demonstrate how the estimates of the coefficient of variation of the Swank and Fano factors behave with data from a Monte Carlo simulation of an indirect x-ray imaging detector. Results: The authors' analyses suggest that the accuracy of their variance estimators is appropriate for estimating the actual variances of the Swank and Fano factors for a variety of distributions of detector outputs. Conclusions: The variance estimators derived in this work provide a computationally convenient way to estimate the error or coefficient of variation of the Swank and Fano factors during Monte Carlo simulations of radiation imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ tumor model for longitudinal in silico imaging trials

Abstract Objective.In this article, we introduce a computational model for simulating the growth of breast cancer lesions accounting for the stiffness of surrounding anatomical structures.Approach.In our model, ligaments are classified as the most rigid structures while the softer parts of the breast are occupied by fat and glandular tissues As a result of these variations in tissue elasticity, the rapidly proliferating tumor cells are met with differential resistance. It is found that these cells are likely to circumvent stiffer terrains such as ligaments, instead electing to proliferate preferentially within the more yielding confines of the breast’s soft topography. By manipulating the interstitial tumor pressure in direct proportion to the elastic constants of the tissues surrounding the tumor, this model thus creates the potential for realizing a database of unique lesion morphology sculpted by the distinctive topography of each local anatomical infrastructure. We modeled the growth of simulated lesions within volumes extracted from fatty breast models, developed by Graffet alwith a resolution of 50μm generated with the open-source and readily available Virtual Imaging Clinical Trials for Regulatory Evaluation (VICTRE) imaging pipeline. To visualize and validate the realism of the lesion models, we leveraged the imaging component of the VICTRE pipeline, which replicates the siemens mammomat inspiration mammography system in a digital format. This system was instrumental in generating digital mammogram (DM) images for each breast model containing the simulated lesions.Results.By utilizing the DM images, we were able to effectively illustrate the imaging characteristics of the lesions as they integrated with the anatomical backgrounds. Our research also involved a reader study that compared 25 simulated DM regions of interest (ROIs) with inserted lesions from our models with DM ROIs from the DDSM dataset containing real manifestations of breast cancer. In general the simulation time for the lesions was approximately 2.5 hours, but it varied depending on the lesion’s local environment.Significance.The lesion growth model will facilitate and enhance longitudinal in silico trials investigating the progression of breast cancer.

Engineering↗

Ptychographic atomic electron tomography: Towards three-dimensional imaging of individual light atoms in materials

Through numerical simulations, we demonstrate the combination of ptychography and atomic electron tomography as an effective method for low dose imaging of individual low-Z atoms in three dimensions. After generating noisy diffraction patterns with multislice simulations of an aberration-corrected scanning transmission electron microscope through a 5-nm zinc-oxide nanoparticle, we have achieved three-dimensional (3D) imaging of individual zinc and oxygen atoms and their defects by performing tomography on ptychographic projections. The methodology has also been simulated in 2D materials, resolving individual sulfur atoms in vertical WS 2 /WSe 2 van der Waals heterostructure with a low total electron dose where annular-dark-field images fail to resolve. Overall, we envision that the development of this method could be instrumental in studying the precise 3D atomic structures of radiation sensitive systems and low-Z atomic structures such as 2D heterostructures, catalysts, functional oxides, and glasses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of bowtie filter and object position on the two-dimensional noise power spectrum of a clinical MDCT system

Purpose: Noise characteristics of clinical multidetector CT (MDCT) systems can be quantified by the noise power spectrum (NPS). Although the NPS of CT has been extensively studied in the past few decades, the joint impact of the bowtie filter and object position on the NPS has not been systematically investigated. This work studies the interplay of these two factors on the two dimensional (2D) local NPS of a clinical CT system that uses the filtered backprojection algorithm for image reconstruction. Methods: A generalized NPS model was developed to account for the impact of the bowtie filter and image object location in the scan field-of-view (SFOV). For a given bowtie filter, image object, and its location in the SFOV, the shape and rotational symmetries of the 2D local NPS were directly computed from the NPS model without going through the image reconstruction process. The obtained NPS was then compared with the measured NPSs from the reconstructed noise-only CT images in both numerical phantom simulation studies and experimental phantom studies using a clinical MDCT scanner. The shape and the associated symmetry of the 2D NPS were classified by borrowing the well-known atomic spectral symbols s, p, and d, which correspond to circular, dumbbell, and cloverleaf symmetries, respectively, of the wave function of electrons in an atom. Finally, simulated bar patterns were embedded into experimentally acquired noise backgrounds to demonstrate the impact of different NPS symmetries on the visual perception of the object. Results: (1) For a central region in a centered cylindrical object, an s-wave symmetry was always present in the NPS, no matter whether the bowtie filter was present or not. In contrast, for a peripheral region in a centered object, the symmetry of its NPS was highly dependent on the bowtie filter, and both p-wave symmetry and d-wave symmetry were observed in the NPS. (2) For a centered region-ofinterest (ROI) in an off-centered object, the symmetry of its NPS was found to be different from that of a peripheral ROI in the centered object, even when the physical positions of the two ROIs relative to the isocenter were the same. (3) The potential clinical impact of the highly anisotropic NPS, caused by the interplay of the bowtie filter and position of the image object, was highlighted in images of specific bar patterns oriented at different angles. The visual perception of the bar patterns was found to be strongly dependent on their orientation. Conclusions: The NPS of CT depends strongly on the bowtie filter and object position. Even if the location of the ROI with respect to the isocenter is fixed, there can be different symmetries in the NPS, which depend on the object position and the size of the bowtie filter. For an isolated off-centered object, the NPS of its CT images cannot be represented by the NPS measured from a centered object.

60 APPLIED LIFE SCIENCES↗

GPU-based prompt gamma ray imaging from boron neutron capture therapy

Purpose: The purpose of this research is to perform the fast reconstruction of a prompt gamma ray image using a graphics processing unit (GPU) computation from boron neutron capture therapy (BNCT) simulations. Methods: To evaluate the accuracy of the reconstructed image, a phantom including four boron uptake regions (BURs) was used in the simulation. After the Monte Carlo simulation of the BNCT, the modified ordered subset expectation maximization reconstruction algorithm using the GPU computation was used to reconstruct the images with fewer projections. The computation times for image reconstruction were compared between the GPU and the central processing unit (CPU). Also, the accuracy of the reconstructed image was evaluated by a receiver operating characteristic (ROC) curve analysis. Results: The image reconstruction time using the GPU was 196 times faster than the conventional reconstruction time using the CPU. For the four BURs, the area under curve values from the ROC curve were 0.6726 (A-region), 0.6890 (B-region), 0.7384 (C-region), and 0.8009 (D-region). Conclusions: The tomographic image using the prompt gamma ray event from the BNCT simulation was acquired using the GPU computation in order to perform a fast reconstruction during treatment. The authors verified the feasibility of the prompt gamma ray image reconstruction using the GPU computation for BNCT simulations.

60 APPLIED LIFE SCIENCES↗

When will low-contrast features be visible in a STEM X-ray spectrum image?

When will a small or low-contrast feature, such as an embedded second-phase particle, be visible in a scanning transmission electron microscopy (STEM) X-ray map? This work illustrates a computationally inexpensive method to simulate X-ray maps and spectrum images (SIs), based upon the equations of X-ray generation and detection. To particularize the general procedure, an example of nanostructured ferritic alloy (NFA) containing nm-sized Y 2 Ti 2 O 7 embedded precipitates in ferritic stainless steel matrix is chosen. The proposed model produces physically appearing simulated SI data sets, which can either be reduced to X-ray dot maps or analyzed via multivariate statistical analysis. Comparison to NFA X-ray maps acquired using three different STEM instruments match the generated simulations quite well, despite the large number of simplifying assumptions used. A figure of merit of electron dose multiplied by X-ray collection solid angle is proposed to compare feature detectability from one data set (simulated or experimental) to another. The proposed method can scope experiments that are feasible under specific analysis conditions on a given microscope. As a result, future applications, such as spallation proton–neutron irradiations, core-shell nanoparticles, or dopants in polycrystalline photovoltaic solar cells, are proposed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A promising limited angular computed tomography reconstruction via segmentation based regional enhancement and total variation minimization

X-ray computed tomography (CT) is a powerful and common inspection technique used for the industrial non-destructive testing. However, large-sized and heavily absorbing objects cause the formation of artifacts because of either the lack of specimen penetration in specific directions or the acquisition of data from only a limited angular range of views. Although the sparse optimization-based methods, such as the total variation (TV) minimization method, can suppress artifacts to some extent, reconstructing the images such that they converge to accurate values remains difficult because of the deficiency in continuous angular data and inconsistency in the projections. To address this problem, we use the idea of regional enhancement of the true values and suppression of the illusory artifacts outside the region to develop an efficient iterative algorithm. This algorithm is based on the combination of regional enhancement of the true values and TV minimization for the limited angular reconstruction. In this algorithm, the segmentation approach is introduced to distinguish the regions of different image knowledge and generate the support mask of the image. A new regularization term, which contains the support knowledge to enhance the true values of the image, is incorporated into the objective function. Then, the proposed optimization model is solved by variable splitting and the alternating direction method efficiently. A compensation approach is also designed to extract useful information from the initial projections and thus reduce false segmentation result and correct the segmentation support and the segmented image. The results obtained from comparing both simulation studies and real CT data set reconstructions indicate that the proposed algorithm generates a more accurate image than do the other reconstruction methods. The experimental results show that this algorithm can produce high-quality reconstructed images for the limited angular reconstruction and suppress the illusory artifacts caused by the deficiency in valid data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-207A-01: A Novel Maximum Likelihood Method for High-Resolution Proton Radiography/proton CT

Purpose: Multiple Coulomb scattering is the largest contributor to blurring in proton imaging. Here we tested a maximum likelihood least squares estimator (MLLSE) to improve the spatial resolution of proton radiography (pRad) and proton computed tomography (pCT). Methods: The object is discretized into voxels and the average relative stopping power through voxel columns defined from the source to the detector pixels is optimized such that it maximizes the likelihood of the proton energy loss. The length spent by individual protons in each column is calculated through an optimized cubic spline estimate. pRad images were first produced using Geant4 simulations. An anthropomorphic head phantom and the Catphan line-pair module for 3-D spatial resolution were studied and resulting images were analyzed. Both parallel and conical beam have been investigated for simulated pRad acquisition. Then, experimental data of a pediatric head phantom (CIRS) were acquired using a recently completed experimental pCT scanner. Specific filters were applied on proton angle and energy loss data to remove proton histories that underwent nuclear interactions. The MTF10% (lp/mm) was used to evaluate and compare spatial resolution. Results: Numerical simulations showed improvement in the pRad spatial resolution for the parallel (2.75 to 6.71 lp/cm) and conical beam (3.08 to 5.83 lp/cm) reconstructed with the MLLSE compared to averaging detector pixel signals. For full tomographic reconstruction, the improved pRad were used as input into a simultaneous algebraic reconstruction algorithm. The Catphan pCT reconstruction based on the MLLSE-enhanced projection showed spatial resolution improvement for the parallel (2.83 to 5.86 lp/cm) and conical beam (3.03 to 5.15 lp/cm). The anthropomorphic head pCT displayed important contrast gains in high-gradient regions. Experimental results also demonstrated significant improvement in spatial resolution of the pediatric head radiography. Conclusion: The proposed MLLSE shows promising potential to increase the spatial resolution (up to 244%) in proton imaging.

60 APPLIED LIFE SCIENCES↗

Identification of breast contour for nipple segmentation in breast magnetic resonance images

Purpose: The purpose of this study is to develop a method to simulate the breast contour and segment the nipple in breast magnetic resonance images. Methods: This study first identifies the chest wall and removes the chest part from the breast MR images. Subsequently, the cleavage and its motion artifacts are removed, distinguishing the separate breasts, where the edge points are sampled for curve fitting. Next, a region growing method is applied to find the potential nipple region. Finally, the potential nipple region above the simulated curve can be removed in order to retain the original smooth contour. Results: The simulation methods can achieve the least root mean square error (RMSE) for certain cases. The proposed YBnd and (Dmin+Dmax)/2 methods are significant due toP = 0.000. The breast contour curve detected by the two proposed methods is closer than that determined by the edge detection method. The (Dmin+Dmax)/2 method can achieve the lowest RMSE of 1.1029 on average, while the edge detection method results in the highest RMSE of 6.5655. This is only slighter better than the comparison methods, which implies that the performance of these methods depends upon the conditions of the cases themselves. Under this method, the maximal Dice coefficient is 0.881, and the centroid difference is 0.36 pixels. Conclusions: The contributions of this study are twofold. First, a method was proposed to identify and segment the nipple in breast MR images. Second, a curve-fitting method was used to simulate the breast contour, allowing the breast to retain its original smooth shape.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-18C-09: Assessment of OSL Dosimeter Technology in the Validation of a Monte Carlo Radiation Transport Code for CT Dosimetry

Purpose: To assess the utility of optically stimulated luminescent (OSL) dosimeter technology in calibrating and validating a Monte Carlo radiation transport code for computed tomography (CT). Methods: Exposure data were taken using both a standard CT 100-mm pencil ionization chamber and a series of 150-mm OSL CT dosimeters. Measurements were made at system isocenter in air as well as in standard 16-cm (head) and 32-cm (body) CTDI phantoms at isocenter and at the 12 o'clock positions. Scans were performed on a Philips Brilliance 64 CT scanner for 100 and 120 kVp at 300 mAs with a nominal beam width of 40 mm. A radiation transport code to simulate the CT scanner conditions was developed using the GEANT4 physics toolkit. The imaging geometry and associated parameters were simulated for each ionization chamber and phantom combination. Simulated absorbed doses were compared to both CTDI{sub 100} values determined from the ion chamber and to CTDI{sub 100} values reported from the OSLs. The dose profiles from each simulation were also compared to the physical OSL dose profiles. Results: CTDI{sub 100} values reported by the ion chamber and OSLs are generally in good agreement (average percent difference of 9%), and provide a suitable way to calibrate doses obtained from simulation to real absorbed doses. Simulated and real CTDI{sub 100} values agree to within 10% or less, and the simulated dose profiles also predict the physical profiles reported by the OSLs. Conclusion: Ionization chambers are generally considered the standard for absolute dose measurements. However, OSL dosimeters may also serve as a useful tool with the significant benefit of also assessing the radiation dose profile. This may offer an advantage to those developing simulations for assessing radiation dosimetry such as verification of spatial dose distribution and beam width.

61 RADIATION PROTECTION AND DOSIMETRY↗