Integrated Nondestructive Assay Systems to Estimate Plutonium in Spent Fuel Assemblies

An integrated nondestructive assay (NDA) system combining active (neutron generator) and passive neutron detection and passive gamma (PG) detection is being analyzed in order to estimate the amount of plutonium, verify initial enrichment, burnup, and cooling time, and detect partial defects in a spent fuel assembly (SFA). Active signals are measured using the differential die-away (DDA), delayed neutron (DN), and delayed gamma (DG) techniques. Passive signals are measured using total neutron (TN) counts and both gross and spectral resolved gamma counts. To quantify how a system of several NDA techniques is expected to perform, all of the relevant NDA techniques listed above were simulated as a function of various reactor conditions such as initial enrichment, burnup, cooling time, assembly shuffling pattern, reactor operating conditions (including temperature, pressure, and the presence of burnable poisons) by simulating the NDA response for five sets of light water reactor assemblies. In this study, we compare the performance of several exploratory model-fitting options (including neural networks, adaptive regression with splines, iterative bias reduction smoothing, projection pursuit regression, and regression with quadratic terms and interaction terms) to relate data simulated with measurement and model error effects from various subsets of the NDA techniques to the total Pu mass. Isotope masses for SFAs and expected detector responses (DRs) for several NDA techniques are simulated using MCNP, and the DRs become inputs to the fitting process. Such responses include eight signals from DDA, one from DN, one from TN, and up to seven from PG; the DG signal will be examined separately. Results are summarized using the root-mean-squared estimation error for plutonium mass in held-out subsets of the data for a range of model and measurement error variances. Different simulation assumptions lead to different spent fuel libraries relating DRs to Pu mass. Some results for training with one library and testing with another library are also given.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Effects of Different Footprint Sizes and Cloud Algorithms on the Top-Of-Atmosphere Radiative Flux Calculation from the Clouds and Earth’s Radiant Energy System (CERES) Instrument on Suomi National Polar-Orbiting Partnership (NPP)

Only one Clouds and Earth’s Radiant Energy System (CERES) instrument is onboard the Suomi National Polar-orbiting Partnership (NPP) and it has been placed in cross-track mode since launch; it is thus not possible to construct a set of angular distribution models (ADMs) specific for CERES on NPP. Edition 4 Aqua ADMs are used for flux inversions for NPP CERES measurements. However, the footprint size of NPP CERES is greater than that of Aqua CERES, as the altitude of the NPP orbit is higher than that of the Aqua orbit. Furthermore, cloud retrievals from the Visible Infrared Imaging Radiometer Suite (VIIRS) and the Moderate Resolution Imaging Spectroradiometer (MODIS), which are the imagers sharing the spacecraft with NPP CERES and Aqua CERES, are also different. To quantify the flux uncertainties due to the footprint size difference between Aqua CERES and NPP CERES, and due to both the footprint size difference and cloud property difference, a simulation is designed using the MODIS pixel-level data, which are convolved with the Aqua CERES and NPP CERES point spread functions (PSFs) into their respective footprints. The simulation is designed to isolate the effects of footprint size and cloud property differences on flux uncertainty from calibration and orbital differences between NPP CERES and Aqua CERES. The footprint size difference between Aqua CERES and NPP CERES introduces instantaneous flux uncertainties in monthly gridded NPP CERES measurements of less than 4.0 W/sq. m for SW (shortwave) and less than 1.0 W/sq. m for both daytime and nighttime LW (longwave). The global monthly mean instantaneous SW flux from simulated NPP CERES has a low bias of 0.4 W/sq. m when compared to simulated Aqua CERES, and the root-mean-square (RMS) error is 2.2 W/sq. m between them; the biases of daytime and night- time LW flux are close to zero with RMS errors of 0.8 and 0.2 W/sq. m. These uncertainties are within the uncertainties of CERES ADMs. When both footprint size and cloud property (cloud fraction and optical depth) differences are considered, the uncertainties of monthly gridded NPP CERES SW flux can be up to 20 W/sq. m in the Arctic regions where cloud optical depth retrievals from VIIRS differ significantly from MODIS. The global monthly mean instantaneous SW flux from simulated NPP CERES has a high bias of 1.1 W/sq. m and the RMS error increases to 5.2 W/sq. m. LW flux shows less sensitivity to cloud property differences than SW flux, with uncertainties of about 2 W/sq. m in the monthly gridded LW flux, and the RMS errors of global monthly mean daytime and nighttime fluxes increase only slightly. These results highlight the importance of consistent cloud retrieval algorithms to maintain the accuracy and stability of the CERES climate data record.

Su, Wenying↗

A Systematic Approach for Model-Based Aircraft Engine Performance Estimation

A requirement for effective aircraft engine performance estimation is the ability to account for engine degradation, generally described in terms of unmeasurable health parameters such as efficiencies and flow capacities related to each major engine module. This paper presents a linear point design methodology for minimizing the degradation-induced error in model-based aircraft engine performance estimation applications. The technique specifically focuses on the underdetermined estimation problem, where there are more unknown health parameters than available sensor measurements. A condition for Kalman filter-based estimation is that the number of health parameters estimated cannot exceed the number of sensed measurements. In this paper, the estimated health parameter vector will be replaced by a reduced order tuner vector whose dimension is equivalent to the sensed measurement vector. The reduced order tuner vector is systematically selected to minimize the theoretical mean squared estimation error of a maximum a posteriori estimator formulation. This paper derives theoretical estimation errors at steady-state operating conditions, and presents the tuner selection routine applied to minimize these values. Results from the application of the technique to an aircraft engine simulation are presented and compared to the estimation accuracy achieved through conventional maximum a posteriori and Kalman filter estimation approaches. Maximum a posteriori estimation results demonstrate that reduced order tuning parameter vectors can be found that approximate the accuracy of estimating all health parameters directly. Kalman filter estimation results based on the same reduced order tuning parameter vectors demonstrate that significantly improved estimation accuracy can be achieved over the conventional approach of selecting a subset of health parameters to serve as the tuner vector. However, additional development is necessary to fully extend the methodology to Kalman filter-based estimation applications.

Simon, Donald L.↗

Spatiotemporal Prediction of Fine Particulate Matter Using High-Resolution Satellite Images in the Southeastern US 2003-2011

Numerous studies have demonstrated that fine particulate matter (PM(sub 2.5), particles smaller than 2.5 micrometers in aerodynamic diameter) is associated with adverse health outcomes. The use of ground monitoring stations of PM(sub 2.5) to assess personal exposure, however, induces measurement error. Land-use regression provides spatially resolved predictions but land-use terms do not vary temporally. Meanwhile, the advent of satellite-retrieved aerosol optical depth (AOD) products have made possible to predict the spatial and temporal patterns of PM(sub 2.5) exposures. In this paper, we used AOD data with other PM(sub 2.5) variables, such as meteorological variables, land-use regression, and spatial smoothing to predict daily concentrations of PM(sub 2.5) at a 1 sq km resolution of the Southeastern United States including the seven states of Georgia, North Carolina, South Carolina, Alabama, Tennessee, Mississippi, and Florida for the years from 2003 to 2011. We divided the study area into three regions and applied separate mixed-effect models to calibrate AOD using ground PM(sub 2.5) measurements and other spatiotemporal predictors. Using 10-fold cross-validation, we obtained out of sample R2 values of 0.77, 0.81, and 0.70 with the square root of the mean squared prediction errors of 2.89, 2.51, and 2.82 cu micrograms for regions 1, 2, and 3, respectively. The slopes of the relationships between predicted PM2.5 and held out measurements were approximately 1 indicating no bias between the observed and modeled PM(sub 2.5) concentrations. Predictions can be used in epidemiological studies investigating the effects of both acute and chronic exposures to PM(sub 2.5). Our model results will also extend the existing studies on PM(sub 2.5) which have mostly focused on urban areas because of the paucity of monitors in rural areas.

PM2.5↗

Recommendations for Using Noise Monitors to Estimate Noise Exposure During X-59 Community Tests

A low fidelity simulation approach is used to explore how to place and use noise monitors during X-59 QueSST community tests, where people’s annoyance to the noise produced by the X-59 aircraft will be gathered. Several recommendations are provided including: 1) the desired number of sparsely spaced noise monitor sites within the survey area, 2) whether to group and average measurements across multiple noise monitors located at a site, 3) what spacing should be used if grouped noise monitors are used, 4) an approach to mitigate ambient noise contamination at the measurement sites, 5) a method to combine empirical and predicted dose estimates to provide a single dose estimate for respondents, and 6) assessing how changes in turbulence intensity and array configuration affect dose uncertainty. To make these recommendations, the error that is expected when fitting contrived, smoothly varying sonic boom “reference exposure surfaces” is studied when a spatially sparse and scattered set of samples is used as responses for the fit. The reference exposure surfaces mimic the sonic boom exposure at ground level that might be expected in the X-59 survey area in the absence of atmospheric turbulence, ambient noise, and other localized effects. The spatial extent of these surfaces varies and is representative of the different survey area sizes that might be expected during future X-59 community overflight tests. These contrived reference surfaces are sampled, and those reference samples are then perturbed to mimic atmospheric turbulence, ambient noise and other localized effects that might affect noise monitor measurements within overflown communities. Two different surface fitting methods are investigated when fitting these perturbed samples to approximate the reference surface. The first method uses interpolation between the perturbed data at the scattered sites to compute the fit. The second method fits a polynomial surface model to the perturbed data using ordinary least squares regression analysis. For both fitting methods, the root mean square fit error is computed from the pointwise difference between the fit surface and the reference surface as the count and configuration of the sites is varied while also averaging the error across many different realizations of both the smooth variation of the reference exposure surface and the random, localized perturbations at the sample sites. Different site configurations are compared using this error statistic to make the recommendations noted above. Additionally, the two fitting approaches (interpolation vs linear regression) are compared based on the fit error observed in these simulations. These analyses, comparisons, and recommendations should inform future decisions on the noise monitor placement and the methods used to analyze the noise monitor data that is collected during X-59 community overflights.

sonic boom↗

SU-D-204-01: Dual-Energy Calibration for Breast Density Measurement Using Spectral Mammography

Purpose: To investigate the feasibility of minimizing the systematic errors in dual-energy breast density quantification induced by the use of tissue-equivalent plastic phantoms as the calibration basis materials. Methods: Dual-energy calibration using tissue-equivalent plastic phantoms was performed on a spectral mammography system based on scanning multi-slit Si strip photon-counting detectors. The plastic phantom calibration used plastic water and adipose-equivalent phantoms as the basis materials, which have different x-ray attenuation properties compared to water and lipid in actual breast tissue. Two methods were used to convert the dual-energy decomposition measurements in plastic phantom thicknesses into true water and lipid basis. The first method was based entirely on the theoretical x-ray attenuation coefficients of the investigated materials in the mammographic energy range. The conversion matrix was determined from least-squares fitting of the target material using the reported attenuation coefficients of water and lipid. The second method was developed based on experimental calibrations, which measured the low-and high-energy signals of pure water and lipid of known thicknesses. A non-linear rational function was used to correlate the decomposed thicknesses to the known values, so that the conversion coefficients can be determined. Both methods were validated using independent measurements of water and lipid mixture phantoms. The correlation of the dual-energy decomposition measurements and the known values were studied with linear regression analysis. Results: There was an excellent linear correlation between the converted water thicknesses and the known values. The slopes of the linear fits were determined to be 0.63 and 1.03 for the simulation and experimental results, respectively. The non-linear fitting in the experimental approach reduced the root-mean-square (RMS) errors from approximately 3.4 mm to 1.5 mm. Conclusion: The results suggested that conversion of the dual-energy measurements into water and lipid thicknesses minimized the systematic errors in tissue decomposition studies.

60 APPLIED LIFE SCIENCES↗

Bayesian and LASSO Regressions for Comparative Permeability Modeling of Sandstone Reservoirs

In this research, Bayesian model averaging (BMA) and least absolute shrinkage and selection operator regression (LASSO) algorithms were adopted for the core permeability modeling as a function of well log and core measurements. More specifically, the core permeability (dependent factor) was modeled given the well log and core data (independent variables) and then predicted in non-cored intervals of a well in a sandstone formation. The BMA is a stochastic linear modeling and a Bayesian parameter selection. Among 50 linear models generated as a function of the independent variables and depicted in Occam’s window, the best model of the highest posterior probability is determined. The best model has the optimal subset parameters that most influences the response factor. The core permeability modeling was again conducted using the LASSO algorithm, which adopts a completely different way of modeling and subset selection by using the penalized least-squared equation. Both BMA and LASSO resulted in a very accurate prediction of the core permeability by achieving perfect measured and calculated permeability matching. Matches for the two algorithms were quantified by computing the adjusted R-squared and root-mean-squared prediction error. In addition, results of the BMA and LASSO were compared to the conventional multiple linear regression (LM). The LASSO algorithm led to an accurate matching similar to LM, but slightly better than BMA. Therefore, both BMA and LASSO represent integrated procedures for accurate permeability estimation similar to conventional regression analysis.

58 GEOSCIENCES↗

IDEAL: Images Across Domains, Experiments, Algorithms and Learning

Research across science domains is increasingly reliant on image-centric data. Software tools are in high demand to uncover relevant, but hidden, information in digital images, such as those coming from faster next generation high-throughput imaging platforms. The challenge is to analyze the data torrent generated by the advanced instruments efficiently, and provide insights such as measurements for decision-making. In this article, we overview work performed by an interdisciplinary team of computational and materials scientists, aimed at designing software applications and coordinating research efforts connecting (1) emerging algorithms for dealing with large and complex datasets; (2) data analysis methods with emphasis in pattern recognition and machine learning; and (3) advances in evolving computer architectures. Engineering tools around these efforts accelerate the analyses of image-based recordings, improve reusability and reproducibility, scale scientific procedures by reducing time between experiments, increase efficiency, and open opportunities for more users of the imaging facilities. This paper describes our algorithms and software tools, showing results across image scales, demonstrating how our framework plays a role in improving image understanding for quality control of existent materials and discovery of new compounds.

97 MATHEMATICS AND COMPUTING↗

Comparison of Combined X-Ray Radiography and Magnetic Resonance (XMR) Imaging-Versus Computed Tomography-Based Dosimetry for the Evaluation of Permanent Prostate Brachytherapy Implants

Purpose: To present a method for the dosimetric analysis of permanent prostate brachytherapy implants using a combination of stereoscopic X-ray radiography and magnetic resonance (MR) imaging (XMR) in an XMR facility, and to compare the clinical results between XMR- and computed tomography (CT)-based dosimetry. Methods and Materials: Patients who had received nonstranded iodine-125 permanent prostate brachytherapy implants underwent XMR and CT imaging 4 weeks later. Four observers outlined the prostate gland on both sets of images. Dose-volume histograms (DVHs) were derived, and agreement was compared among the observers and between the modalities. Results: A total of 30 patients were evaluated. Inherent XMR registration based on prior calibration and optical tracking required a further automatic seed registration step that revealed a median root mean square registration error of 4.2 mm (range, 1.6-11.4). The observers agreed significantly more closely on prostate base and apex positions as well as outlining contours on the MR images than on those from CT. Coefficients of variation were significantly higher for observed prostate volumes, D90, and V100 parameters on CT-based dosimetry as opposed to XMR. The XMR-based dosimetry showed little agreement with that from CT for all observers, with D90 95% limits of agreement ranges of 65, 118, 79, and 73 Gy for Observers 1, 2, 3, and 4, respectively. Conclusions: The study results showed that XMR-based dosimetry offers an alternative to other imaging modalities and registration methods with the advantages of MR-based prostate delineation and confident three-dimensional reconstruction of the implant. The XMR-derived dose-volume histograms differ from the CT-derived values and demonstrate less interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward Submillimeter Accuracy in the Management of Intrafraction Motion: The Integration of Real-Time Internal Position Monitoring and Multileaf Collimator Target Tracking

Purpose: We report on an integrated system for real-time adaptive radiation delivery to moving tumors. The system combines two promising technologies-three-dimensional internal position monitoring using implanted electromagnetically excitable transponders and corresponding real-time beam adaptation using a dynamic multileaf collimator (DMLC). Methods and Materials: In a multi-institutional academic and industrial collaboration, a research version of the Calypso position monitoring system was integrated with a DMLC-based four-dimensional intensity-modulated radiotherapy delivery system using a Varian 120-leaf multileaf collimator (MLC). Two important determinants of system performance-latency (i.e., elapsed time between target motion and MLC response) and geometric accuracy-were investigated. Latency was quantified by acquiring continuous megavoltage X-ray images of a moving phantom (with embedded transponders) that was tracked in real time by a circular MLC field. The latency value was input into a motion prediction algorithm within the DMLC tracking system. Geometric accuracy was calculated as the root-mean-square positional error between the target and the centroid of the MLC aperture for patient-derived three-dimensional motion trajectories comprising two lung tumor traces and one prostate trace. Results: System latency was determined to be approximately 220 milliseconds. Tracking accuracy was observed to be sub-2 mm for the respiratory motion traces and sub-1 mm for prostate motion. Conclusion: We have developed and characterized a research version of a novel four-dimensional delivery system that integrates nonionizing radiation-based internal position monitoring and accurate real-time DMLC-based beam adaptation. This system represents a significant step toward achieving the eventual goal of geometrically ideal dose delivery to moving tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A learned closure method applied to phase mixing in a turbulent gradient-driven gyrokinetic system in simple geometry

We present a new method for formulating closures that learn from kinetic simulation data. We apply this method to phase mixing in a simple gyrokinetic turbulent system – temperature-gradient-driven turbulence in an unsheared slab. The closure, called the learned multi-mode (LMM) closure, is constructed by, first, extracting an optimal basis from a nonlinear kinetic simulation using singular value decomposition. Subsequent nonlinear fluid simulations are projected onto this basis and the results are used to formulate the closure. We compare the closure with other closures schemes over a broad range of the relevant two-dimensional parameter space (collisionality and gradient drive). We find that the turbulent kinetic system produces phase-mixing rates much lower than the linear expectations, which the LMM closure is capable of capturing. We also compare radial heat fluxes. A Hammett–Perkins closure, generalized to include collisional effects, is quite successful throughout the parameter space, producing ${\sim }14\,\%$ root-mean-square (r.m.s.) error. The LMM closure is also very effective: when trained at three (two) points (in a 35 point parameter grid), the LMM closure produces $8\,\%$ ( $12\,\%$ ) r.m.s. errors. The LMM procedure can be readily generalized to other closure problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effective Local Geometry Descriptor for 29Si NMR Q4 Anisotropy

The nuclear shielding anisotropy, ζ, is a useful nuclear magnetic resonance (NMR) shielding tensor parameter in describing the extent of electron cloud distortion about an atom. Despite the advantages afforded by NMR in structural characterization, the relationship between ζ and local structure of an atom in high-symmetry environments, such as Si-Q 4 sites, is poorly understood. Here, we use a data-driven approach combining random forest feature ranking and the Sure Independence Screening and Sparsifying Operator (SISSO) approach to derive a simple and accurate geometric descriptor for ζ with a root-mean-squared prediction error of 6.77 ppm and an R 2 of 0.761. We then apply this descriptor to describe the local geometric distortion of zeolites Sigma-2 and silica-ZSM-5 whose chemical shift anisotropy tensor has been reported. We envision that this geometric descriptor will allow for structural description and refinement in previously difficult-to-describe materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Review, evaluation, and discussion of the challenges of missing value imputation for mass spectrometry-based label-free global proteomics

In this review, we apply selected imputation strategies to label-free liquid chromatography–mass spectrometry (LC–MS) proteomics datasets to evaluate the accuracy with respect to metrics of variance and classification. We evaluate several commonly used imputation approaches for individual merits and discuss the caveats of each approach with respect to the example LC–MS proteomics data. In general, local similarity-based approaches, such as the regularized expectation maximization and least-squares adaptive algorithms, yield the best overall performances with respect to metrics of accuracy and robustness. However, no single algorithm consistently outperforms the remaining approaches, and in some cases, performing classification without imputation sometimes yielded the most accurate classification. Thus, because of the complex mechanisms of missing data in proteomics, which also vary from peptide to protein, no individual method is a single solution for imputation. In summary, on the basis of the observations in this review, the goal for imputation in the field of computational proteomics should be to develop new approaches that work generically for this data type and new strategies to guide users in the selection of the best imputation for their dataset and analysis objectives.

59 BASIC BIOLOGICAL SCIENCES↗

On the nonadiabatic collisional quenching of OH(A) by H 2 : a four coupled quasi-diabatic state description

A four-state diabatic potential energy matrix (DPEM), H d , for the description of the nonadiabatic quenching of OH(A 2 Σ + ) by collisions with H 2 is reported. The DPEM is constructed as a fit to adiabatic energies, energy gradients, and derivative couplings obtained exclusively from multireference configuration interaction wave functions. A four-adiabatic-electronic-state representation is used in order to describe all energetically accessible regions of the nuclear coordinate space. Partial permutation-inversion symmetry is incorporated into the representation. Here, the fit is based on electronic structure data at 42 882 points, described by over 1.6 million least squares equations with a root mean square (mean unsigned) error of 178(83) cm –1 . Comparison of ab initio and H d determined minima, saddle points, and energy minimized points on C 2v , C s , C ∞v , and C 1 (noncoplanar) portions of two conical intersection seams are used to establish the accuracy of the H d .

74 ATOMIC AND MOLECULAR PHYSICS↗

A digital optical phase-locked loop for diode lasers based on field programmable gate array

We have designed and implemented a highly digital optical phase-locked loop (OPLL) for diode lasers in atom interferometry. The three parts of controlling circuit in this OPLL, including phase and frequency detector (PFD), loop filter and proportional integral derivative (PID) controller, are implemented in a single field programmable gate array chip. A structure type compatible with the model MAX9382/MCH12140 is chosen for PFD and pipeline and parallelism technology have been adapted in PID controller. Especially, high speed clock and twisted ring counter have been integrated in the most crucial part, the loop filter. This OPLL has the narrow beat note line width below 1 Hz, residual mean-square phase error of 0.14 rad{sup 2} and transition time of 100 {mu}s under 10 MHz frequency step. A main innovation of this design is the completely digitalization of the whole controlling circuit in OPLL for diode lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning for impurity charge-state transition levels in semiconductors from elemental properties using multi-fidelity datasets

Quantifying charge-state transition energy levels of impurities in semiconductors is critical to understanding and engineering their optoelectronic properties for applications ranging from solar photovoltaics to infrared lasers. While these transition levels can be measured and calculated accurately, such efforts are time-consuming and more rapid prediction methods would be beneficial. Here, we significantly reduce the time typically required to predict impurity transition levels using multi-fidelity datasets and a machine learning approach employing features based on elemental properties and impurity positions. We use transition levels obtained from low-fidelity (i.e., local-density approximation or generalized gradient approximation) density functional theory (DFT) calculations, corrected using a recently proposed modified band alignment scheme, which well-approximates transition levels from high-fidelity DFT (i.e., hybrid HSE06). Further, the model fit to the large multi-fidelity database shows improved accuracy compared to the models trained on the more limited high-fidelity values. Crucially, in our approach, when using the multi-fidelity data, high-fidelity values are not required for model training, significantly reducing the computational cost required for training the model. Our machine learning model of transition levels has a root mean squared (mean absolute) error of 0.36 (0.27) eV vs high-fidelity hybrid functional values when averaged over 14 semiconductor systems from the II–VI and III–V families. As a guide for use on other systems, we assessed the model on simulated data to show the expected accuracy level as a function of bandgap for new materials of interest. Finally, we use the model to predict a complete space of impurity charge-state transition levels in all zinc blende III–V and II–VI systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗