Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear data validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Development of tools and techniques for momentum compression of fast rare isotopes

As part of our past research and development work, we have created and developed the LISE++ simulation code [Tar04, Tar08]. The LISE++ package was significantly extended with the addition of a Monte Carlo option that includes an option for calculating ion trajectories using a Taylor-series expansion up to fifth order, and implementation of the MOTER Monte Carlo code [Kow87] for ray tracing of the ions into the suite of LISE++ codes. The MOTER code was rewritten from FORTRAN into C++ and transported to the MS-Windows operating system. Extensive work went into the creation of a user-friendly interface for the code. An example of the graphical user interface created for the MOTER code is shown in the left panel of Figure 1 and the results of a typical calculation for the trajectories of particles that pass through the A1900 fragment separator are shown in the right panel. The MOTER code is presently included as part of the LISE++ package for downloading without restriction by the worldwide community. The LISE++ was extensively developed and generalized to apply to any projectile fragment separator during the early phase of this grant. In addition to the inclusion of the MOTER code, other important additions to the LISE++ code made during FY08/FY09 are listed. The LISE++ is distributed over the web (http://groups.nscl.msu.edu/lise ) and is available without charge to anyone by anonymous download, thus, the number of individual users is not recorded. The number of 'hits' on the servers that provide the LISE++ code is shown in Figure 3 for the last eight calendar years (left panel) along with the country from the IP address (right panel). The data show an increase in web-activity with the release of the new version of the program during the grant period and a worldwide impact. An important part of the proposed work carried out during FY07, FY08 and FY09 by a graduate student in the MSU Physics program was to benchmark the codes by comparison of detailed measurements to the LISE++ predictions. A large data set was obtained for fission fragments from the reaction of 238U ions at 81 MeV/u in a 92 mg/cm2 beryllium target with the A1900 projectile fragment separator. The data were analyzed and form the bulk of a Ph.D. dissertation that is nearing completion. The rich data set provides a number of benchmarks for the improved LISE++ code and only a few examples can be shown here. The primary information obtained from the measurements is the yield of the products as a function of mass, charge and momentum. Examples of the momentum distributions of individually identified fragments can be seen in Figures 2 and 4 along with comparisons to the predicted distributions. The agreement is remarkably good and indicates the general validity of the model of the nuclear reactions producing these fragments and of the higher order transmission calculations in the LISE++ code. The momentum distributions were integrated to provide the cross sections for the individual isotopes. As shown in Figure 5, there is good agreement with the model predictions although the observed cross sections are a factor of five or so higher in this case. Other comparisons of measured production cross sections from abrasion-fission reactions have been published by our group working at the NSCL during this period [Fol09] and through our collaboration with Japanese researchers working at RIKEN with the BigRIPS separator [Ohn08, Ohn10]. The agreement of the model predictions with the data obtained with two different fragment separators is very good and indicates the usefulness of the new LISE++ code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An analysis method for experiment power in the ATR

The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) is used for testing and qualification of nuclear fuels and materials. The ATR has been irradiating the lead test assembly (LTA) for the planned Ki-Jang Research Reactor (KJRR) in Korea. Irradiation and subsequent Post-Irradiation Examination (PIE) of the LTA will lead to qualification of the fuel to support licensing activities. Qualification of the LTA requires the experiment to meet specific thermal and burn-up conditions. In particular, plate 20 of the experiment must obtain a heat flux between 137 and 200 W/cm{sup 2} with a target U-235 depletion of 79-84%. Due to the limited instrumentation and burn-up monitoring capabilities, assurance of meeting experiment goals is verified through modelling. In order to validate the experiment model using ATR operating data, a methodology was developed to compare the calculated experiment power with ATR power monitoring instrumentation. This paper discusses the methodology used to quantify the experiment power and uncertainty in the model based on ATR operating conditions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Estimation of Respirable Aerosol Release Fractions through Stress Corrosion Crack-Like Geometries

The formation of a stress corrosion crack (SCC) in the canister wall of a dry cask storage system (DCSS) has been identified as a potential issue for the long-term storage of spent nuclear fuel. The presence of an SCC in a storage system could represent a through-wall flow path from the canister interior to the environment. Modern, vertical DCSSs are of particular interest due to the significant backfill pressurization of the canister, up to approximately 800 kPa. This pressure differential offers a relatively high driving potential for blowdown of any particulates that might be present in the canister. In this study, the carrier gas flow rates and aerosol transmission properties were evaluated for an engineered microchannel with characteristic dimensions similar to those of an SCC. The microchannel was formed by mating two gage blocks with a slot orifice measuring 28.9 μm (0.0011 in.) tall by 12.7 mm (0.500 in.) wide by 8.86 mm (0.349 in.) long (flow length). Surrogate aerosols of cerium oxide, Ce0 2 , were seeded and mixed inside a pressurized tank. The aerosol characteristics were measured immediately upstream and downstream of the simulated SCC at elevated and ambient pressures, respectively. These data sets are intended to demonstrate a new capability to characterize SCCs under well-controlled boundary conditions. Separate modeling efforts are also underway that will be validated using these data. The test apparatus and procedures developed in this study can be easily modified for the evaluation of more complex SCC-like geometries including laboratory-grown SCC samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On the determination of reference levels for quality assurance of flattening filter free photon beams in radiation therapy

Purpose: New definitions for some dosimetric parameters for use in quality assurance of flattening filter free (FFF) beams generated by medical linear accelerators have been suggested. The present study aims to validate these suggestions and to propose possible reference levels. Methods: The main characteristics of FFF photon beams were described in terms of: field size, penumbra, unflatness, slope, and peak-position parameters. Data were collected for 6 and 10 MV-FFF beams from three different Varian TrueBeam Linacs. Measurements were performed with a 2D-array (Starcheck system from PTW-Freiburg) and with the portal dosimetry method GLAaS utilizing the build-in portal imager of TrueBeam. Data were also compared to ion chamber measurements. A cross check validation has been performed on a FFF beam of 6 MV generated by a Varian Clinac-iX upgraded to FFF capability. Results : All the parameters suggested to characterize the FFF beams resulted easily measurable and little variation was observed among different Linacs. Referring to two reference field sizes of 10 × 10 and 20 × 20 cm{sup 2}, at SDD = 100 cm and d = dmax, from the portal dosimetry data, the following results (averaging X and Y profiles) were obtained. Field size: 9.95 ± 0.02 and 19.98 ± 0.03 cm for 6 MV-FFF (9.94 ± 0.02 and 19.98 ± 0.03 cm for 10 MV-FFF). Penumbra: 2.7 ± 0.3 and 2.9 ± 0.3 mm for 6 MV-FFF (3.1 ± 0.2 and 3.3 ± 0.3 for 10 MV-FFF). Unflatness: 1.11 ± 0.01 and 1.25 ± 0.01 for 6 MV-FFF (1.21 ± 0.01 and 1.50 ± 0.01 for 10 MV-FFF). Slope: 0.320 ± 0.020%/mm and 0.43 ± 0.015%/mm for 6 MV-FFF (0.657 ± 0.023%/mm and 0.795 ± 0.017%/mm for 10 MV-FFF). Peak Position −0.2 ± 0.2 and −0.4 ± 0.2 mm for 6 MV-FFF (−0.3 ± 0.2 and 0.7 ± 0.3 mm for 10 MV-FFF). Results would depend upon measurement depth. With thresholds set to at least 95% confidence level from the measured data and to account for possible variations between detectors and methods and experimental settings, a tolerance set of: 1 mm for field size and penumbra, 0.04 for unflatness, 0.1%/mm for slope, and 1 mm for peak position could be proposed from our data. Conclusions : The parameters proposed for the characterization and routine control of stability of profiles of FFF beams appear to be a viable solution with a strong similarity to the conventional parameters used for flattened beams. The results from three different TrueBeams and the cross-validation against a Clinac-iX suggested the possible generalization of the methods and the possibility to use common tolerances for the parameters. The data showed also the reproducibility of beam characteristics among different systems (of the same vendor) and the resulting parameter values could therefore be possibly generalized.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and validation of a quantitative proton NMR method for the analysis of pregnenolone

Pregnenolone (PREG) is an endogenous steroid frequently sold as an over-the-counter dietary supplement touted to promote neurological and immunological health. While the PREG dietary supplement is added to the diet for health benefits, there are no FDA approved PREG drugs. However, compounded PREG drug products are available to U.S. patients. The FDA works with state regulatory authorities on the oversight of compounding activities, including developing 503A and 503B lists of bulk substances that compounders are permitted to use. PREG is one of the substances publicly nominated to be included on the 503B list. Compounded hormone therapies such as those using PREG are of interest given the lack of standardization in compounded drug products which may increase the possibility of underdosing, overdosing, or contamination. However, no USP monograph currently exists to evaluate the quality of PREG drug substance or product. To address knowledge gaps and assist in quality control, a simple and rapid quantitative proton nuclear magnetic resonance spectroscopy (qNMR) method for the identification and assay of PREG in different types of PREG products was developed and validated. PREG samples were characterized using 1D 1 H and 2D 1 H– 13 C HSQC NMR spectra. The qNMR assay method (taking approximately 10 min per NMR spectrum) was validated for precision, accuracy, specificity, robustness and linearity per ICH Q2(R1) guidance. The method was validated in a range from 0.032 to 3.2 mg/mL. As a proof of concept, seven PREG bulk substance samples, three tablet and two capsule PREG dietary supplements were assessed by the qNMR analytical procedure. NMR data from all tested samples met the expected criteria for identification and assay. The results demonstrate the potential of qNMR for the quality assessment of different types of PREG samples.

60 APPLIED LIFE SCIENCES↗

On-board Radiation Sensor and Low-Altitude Contour Mapping of Radiation Fields using UAS Swarm - 18239

This paper addresses the design of light weight radiation sensors for the small-scale unmanned aerial system (UAS), and its implementation for low-altitude radiation source localization and contour mapping. The compact, high-resolution gamma-ray CZT sensors were integrated to UAS platforms as plug-and-play components using Robot Operation System (ROS). In this work, the UAS swarm consists of three platforms positioned in circular formation. The onboard data analysis provides time and position stamped intensities of gamma-ray peaks for each UAS-based sensor that are used as the input data for the swarm flight control algorithm. Each UAS measures radiation simultaneously for estimating gradient of radiation to compute a bulk heading angle of the swarm for contour mapping, which can provide relatively precise boundary of the safe area for potential human exploration. The UAS radiation sensors allow measurements from just few meters up to hundreds of meters thus filling the gap between land- and helicopter- based platforms. The swarm of UAS has advantages over a single agent based approach in detecting radiative sources and effectively mapping the area. The proposed method can locate sources of radiation as well as mapping the contaminated area for enhancing situation awareness capabilities for first responders. Computer simulation is presented for UAS swarm based source localization and contour mapping in the simulated radiation fields created by the MCNP code. Selected key gradient estimation and contour mapping algorithms are validated experimentally with small scale multicopter UAS in the indoor flight test bed. (authors)

42 ENGINEERING↗

Scaling Analysis of Vortex Shedding Frequency between In line Plates

The Global Threat Reduction initiative (GTRI) was established by the National Nuclear Security Administration (NNSA) in 2004. One of the highlights of the program is to convert research and test reactors at home and abroad from Highly Enriched Uranium (HEU) to Low Enriched Uranium (LEU) fuels. By switching directly from HEU to LEU, an LEU reactor produces fewer neutrons than an HEU reactor and in some cases; a direct switch from HEU to LEU results in the reactor being unable to achieve criticality. Under certain circumstances, criticality is achieved and the original neutron fluxes are restored with LEU fuel by adding more fuel elements to the core. Not all reactors, exemplified by the Advanced Test Reactor (ATR) at the Idaho National Lab (INL), have the luxury of simply adding more fuel to the core. In such cases, entirely new designs must be created and tested. The ATR utilizes plate type fuel. During the design and testing of the ATR fuel, vortex shedding was identified as potential source for experiment and fuel failure. For fuel conversion, elements must be tested in pile prior to the qualification of the new fuel design. For some test elements, the primary test plate is followed by a secondary handling plate. It is known that objects downstream influence the vortex shedding. While vortex shedding is an important and well-studied phenomenon, not only in the context of nuclear engineering, but in fields as diverse as aeronautical engineering and biology, there is a significant gap in the understanding of vortex shedding in regards to two bluff bodies in line direct line with one another. The study provides a scaling analysis of the frequency of vortex shedding for plates in line. The scaling analysis is then compared to numerical simulation of two in line plates. The study provided a scaling analysis and suggested parameter for determining the expected trends in the Strouhal number for a plate with some object downstream. The analysis made the consideration of differing length scales as the cause for a reduction in vortex shedding frequency as well as looked at the potential impact of boundary layer growth on vortex shedding for a flat plate. The comparison between the expected scaling and numerical data was less than ideal, but there are several potential causes. One of the biggest issues with the comparison is the uncertainty associated with the defect velocity. The frequency was well established in several cases, but the velocity was not always well established resulting in a larger uncertainty. In the cases where the velocity was near zero (i.e. b/d = 0.5), the uncertainty dominated since the corrected Strouhal number is divided by the defect velocity. The Reynolds numbers were not incredibly large, ranging from 350-1600. The low Reynolds numbers potentially undermine the principle assumption made in the scaling analysis, i.e. Reynolds number is negligibly small. Additionally, the exact definition of the 'reduced velocity' was never explicitly defined, merely inferred from the assumption that the x length scale and y length scale were in fact different. Another potential problem is the defect velocities in the lower Reynolds number cases were not much smaller than the free stream velocity. Further work needs to be done at higher Reynolds numbers and with more data points to ensure the assumptions made are valid as well as confirm the accuracy of the scaled relationship. (authors)

42 ENGINEERING↗

Validation and uncertainty of DRF's for a 1"×2" NaI collimated detector for radioisotope holdup measurements

Detector response functions (DRFs) have become the subject of increasing scientific interest for the last thirty years in several industrial applications of radiation detection. These applications include gamma-ray, prompt gamma-ray, and X-ray spectrometry for elemental analysis and location as applied to mining, radio-tracing in medicine, and holdup source characterization. However, it is difficult to create a rigorous mathematical formulation of the DRF. Therefore, semi-empirical and stochastic approaches have been developed instead to construct detector and application specific DRFs. A DRF can be considered to be a function that converts the energy-dependent incidence of incoming source particles onto a detector into a detector response spectrum that simulates the experimental response. The DRF can also be used in the reverse sense in an inverse problem setting, as a step in the process of predicting the physical characteristics of an unknown source (e.g. the holdup problem and library spectra). Much of the recent work on DRFs has been performed by Gardner. He has developed accurate DRF models through semi-empirical curve fitting and Monte Carlo simulation. His DRFs for 3" X 3" NaI detectors have been developed with the experimental measurements taken by Heath and for 6"x6" bare (unshielded) NaI(Tl) detector data with single-energy sources centered on the detector face at a distance of 10 cm. There was agreement with the Heath benchmark detector measurements within two Poisson standard deviations of the measured data. DRFs have also been developed for other detectors such as high purity Germanium detectors and Si(Li) for the same geometries as NaI. Other than a few artifacts such as backscatter peaks, there was good agreement between simulated responses and the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical basis for peak reactivity burnup credit for BWR spent nuclear fuel in storage and transportation systems - 14601

Oak Ridge National Laboratory and the United States Nuclear Regulatory Commission have initiated a multiyear project to investigate application of burnup credit for boiling-water reactor (BWR) fuel in storage and transportation casks. This project includes two phases. The first phase (1) investigates applicability of peak reactivity methods currently used in spent fuel pools (SFPs) to storage and transportation systems and (2) evaluates validation of both reactivity (k{sub eff}) calculations and burnup credit nuclide concentrations within these methods. The second phase will focus on extending burnup credit beyond peak reactivity. This paper documents the first phase, including an analysis of lattice design parameters and depletion effects, as well as both validation components. Initial efforts related to extended burnup credit are discussed in a companion paper. Peak reactivity analyses have been used in criticality analyses for licensing of BWR fuel in SFPs over the last 20 years. These analyses typically combine credit for the gadolinium burnable absorber present in the fuel with a modest amount of burnup credit. Gadolinium burnable absorbers are used in BWR assemblies to control core reactivity. The burnable absorber significantly reduces assembly reactivity at beginning of life, potentially leading to significant increases in assembly reactivity for burnups less than 15-20 GWd/MTU. The reactivity of each fuel lattice is dependent on gadolinium loading. The number of gadolinium-bearing fuel pins lowers initial lattice reactivity, but it has a small impact on the burnup and reactivity of the peak. The gadolinium concentration in each pin has a small impact on initial lattice reactivity but a significant effect on the reactivity of the peak and the burnup at which the peak occurs. The importance of the lattice parameters and depletion conditions are primarily determined by their impact on the gadolinium depletion. Criticality code validation for BWR burnup credit at peak reactivity requires a different set of experiments than for pressurized-water reactor burnup credit analysis because of differences in actinide compositions, presence of residual gadolinium absorber, and lower fission product concentrations. A survey of available critical experiments is presented along with a sample criticality code validation and determination of undercoverage penalties for some nuclides. The validation of depleted fuel compositions at peak reactivity presents many challenges which largely result from a lack of radiochemical assay data applicable to BWR fuel in this burnup range. In addition, none of the existing low burnup measurement data include residual gadolinium measurements. An example bias and uncertainty associated with validation of actinide-only fuel compositions is presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of an In-Situ Decommissioning Sensor Network Test Bed for Structural Condition Monitoring - 12156

The Savannah River National Laboratory (SRNL) has established an In Situ Decommissioning (ISD) Sensor Network Test Bed, a unique, small scale, configurable environment, for the assessment of prospective sensors on actual ISD system material, at minimal cost. The Department of Energy (DOE) is presently implementing permanent entombment of contaminated, large nuclear structures via ISD. The ISD end state consists of a grout-filled concrete civil structure within the concrete frame of the original building. Validation of ISD system performance models and verification of actual system conditions can be achieved through the development a system of sensors to monitor the materials and condition of the structure. The ISD Sensor Network Test Bed has been designed and deployed to addresses the DOE-Environmental Management Technology Need to develop a remote monitoring system to determine and verify ISD system performance. Commercial off-the-shelf sensors have been installed on concrete blocks taken from walls of the P Reactor Building at the Savannah River Site. Deployment of this low-cost structural monitoring system provides hands-on experience with sensor networks. The initial sensor system consists of groutable thermistors for temperature and moisture monitoring, strain gauges for crack growth monitoring, tilt-meters for settlement monitoring, and a communication system for data collection. Baseline data and lessons learned from system design and installation and initial field testing will be utilized for future ISD sensor network development and deployment. The Sensor Network Test Bed at SRNL uses COTS sensors on concrete blocks from the outer wall of the P Reactor Building to measure conditions expected to occur in ISD structures. Knowledge and lessons learned gained from installation, testing, and monitoring of the equipment will be applied to sensor installation in a meso-scale test bed at FIU and in future ISD structures. The initial data collected from the sensors installed on the P Reactor Building blocks define the baseline materials condition of the P Reactor ISD external concrete structure. Continued monitoring of the blocks will enable evaluation of the effects of aging on the P Reactor ISD structure. The collected data will support validation of the material degradation model and assessment of the condition of the ISD structure over time. The following are recommendations for continued development of the ISD Sensor Network Test Bed: - Establish a long-term monitoring program using the concrete blocks with existing sensor and/or additional sensors for trending the concrete materials and structural condition; - Continue development of a stand-alone test bed sensor system that is self-powered and provides wireless transmission of data to a user-accessible dashboard; - Develop and implement periodic NDE/DE characterization of the concrete blocks to provide verification and validation for the measurements obtained through the sensor system and concrete degradation model(s). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Verification of the Effectiveness of X-ray Machine Collimation

The Oak Ridge National Laboratory (ORNL) was tasked by the United States National Nuclear Security Administration’s Second Line of Defense (SLD) program with reducing the false alarm rate experienced by radiation portal monitors (RPM) installed near x-ray machines. Although the mechanism for interference between RPMs and x-ray machines is well understood, x-ray machines are often installed too near RPMs due to a variety of facility constraints. The result is underutilized RPMs that are plagued by a high false alarm rate from x-rays that escape the x-ray machine and are detected by the RPM. In this work, the effectiveness of an x-ray machine collimation system designed at ORNL is validated through the analysis of field data collected before and after the installation. The significant reduction in false alarm rate due to the collimation system is explicitly shown, and examples of field installations are provided. Utilization of the results presented here allows RPM systems to operate effectively even when installed near x-ray machines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the neutron induced reactions on 235 U from 2.25 keV up to 30 MeV

An evaluation of fast neutron induced reactions on 235 U is performed in the 2.25 keV–30 MeV incident energyrangewiththecodeEMPIRE–3.2Malta,combinedwithselectedexperimentaldata.Thereactionmodelincludes a dispersive optical model potential (RIPL 2408) that couples seven levels of the ground-state rotational band and a triple-humped fission barrier with absorption in the wells described within the optical model for fission. EGSM nuclear level densities are used in Hauser-Feshbach calculations of the compound-nuclear decay. The starting values for the modelparameters are retrievedfrom the RIPL-3 data-base. Excellentagreementis achievedwithavailable experimental data for neutron emission, neutron capture and fission, which gives confidence that the quantities for which there is no experimental information are also predicted accurately. In the fast neutron region of the evaluated file, the fission cross section is taken from Neutron Standards, and neutron capture includes fluctuations observed in recent experiments. Other channels are taken directly from model calculations. New evaluation is validated against ICSBEP criticality benchmarks with fast neutron spectra with excellent results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement uncertainty of rossi-alpha neutron experiments

Rossi-alpha neutron experiments are used to estimate the prompt neutron decay constant of a fissile assembly, a quantity of widespread interest in applications including in nuclear nonproliferation and criticality safety. This work develops a mathematical model to efficiently estimate measurement uncertainty of Rossi-alpha neutron experiments inferred from a two-exponential fit model with histogram binning. The derived uncertainty estimates were validated using repeated Rossi-alpha measurements of a subcritical, 4.5-kg sphere of weapons-grade, alpha-phase plutonium with nickel, copper, tungsten, and polyethylene reflectors. The estimates of uncertainty for the histogram data produced by the model were conservative and agree with the reference uncertainties within noise. The estimates of the prompt neutron decay constant uncertainty agreed with the reference uncertainties within one standard deviation. In conclusion, the proposed model will reduce total measurement times, ultimately reducing operational and procedural costs in application.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlations for the specific heat capacity of ( U x Pu 1 - x ) 1 - y Gd y O 2 - z derived from molecular dynamics

We report UO 2 is the primary conventional fuel used in most nuclear reactors with Gd 2 O 3 commonly added as a burnable absorber to produce a more level power distribution in the reactor core at the beginning of operation. It can also be mixed with other actinide oxides to produce mixed oxide (MOx) fuel. In this study, molecular dynamics simulations were used to predict the specific heat capacity of Gd-doped PuO 2 , UO 2 and (U, Pu)O 2 MOx accommodating Gd 3+ substituted at cation sites via two charge compensation mechanisms - oxygen vacancy formation and the oxidation of U 4+ to U 5+ . The specific heat capacity values for PuO 2 and UO 2 are in good agreement with other studies showing a distinct peak at high temperatures - above 1800 K. As Gd 3+ is added, the peak height reduces for each composition considered. An analytical fit was applied to the data where Gd 3+ was fully charge compensated by either oxygen vacancies or U 5+ . The expression was then validated by predicting the specific heat capacity for three compositions of (Ux Pu 1-x ) 1-y Gd y O 2-z containing both oxygen vacancies and U 5+ , and compared to molecular dynamics data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A micron resolution optical scanner for characterization of silicon detectors

The emergence of high position resolution (∼10 μm) silicon detectors in recent times have highlighted the urgent need for the development of new automated optical scanners of micron level resolution suited for characterizing microscopic features of these detectors. More specifically, for the newly developed silicon photo-multipliers (SiPM) that are compact, possessing excellent photon detection efficiency with gain comparable to photo-multiplier tube. In a short time, since their invention the SiPMs are already being widely used in several high-energy physics and astrophysics experiments as the photon readout element. The SiPM is a high quantum efficiency, multi-pixel photon counting detector with fast timing and high gain. The presence of a wide variety of photo sensitive silicon detectors with high spatial resolution requires their performance evaluation to be carried out by photon beams of very compact spot size. We have designed a high resolution optical scanner that provides a monochromatic focused beam on a target plane. The transverse size of the beam was measured by the knife-edge method to be 1.7 μm at 1 − σ level. Since the beam size was an order of magnitude smaller than the typical feature size of silicon detectors, this optical scanner can be used for selective excitation of these detectors. The design and operational details of the optical scanner, high precision programmed movement of target plane (0.1 μm) integrated with general purpose data acquisition system developed for recording static and transient response photo sensitive silicon detector are reported in this paper. Entire functionality of scanner is validated by using it for selective excitation of individual pixels in a SiPM and identifying response of active and dead regions within SiPM. Results from these studies are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation and testing of the GPT sensitivities in TRIPOLI-4

Computing the sensitivity of given reactor parameters with respect to nuclear data is mandatory in key applications such as the assessment of reactor safety or core design. In recent years, the development of Monte Carlo methods capable of estimating sensitivity coefficients based on the Standard or Generalized Perturbation Theory (SPT and GPT, respectively) has attracted intensive research efforts, especially in view of having reference golden standard simulations to be compared to faster but approximate deterministic calculations. Following our previous implementation and validation of the SPT functionalities in the Monte Carlo TRIPOLI-4, devoted to the sensitivity of the k eigenvalue, in this work we detail the development of GPT methods for ratios of reaction rates, and validate them against a few relevant benchmark results. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Direct determination of cellulosic glucan content in starch-containing samples

A simple and highly selective analytical procedure is presented for the determination of cellulosic glucan content in samples that contain both cellulose and starch. This method eliminates the unacceptably large compounding errors of current two-measurement methods. If both starch and cellulose are present before analytical hydrolysis, both will be hydrolyzed to glucose causing bias and inaccuracy in the method. To prevent this interference, the removal of starch prior to cellulosic quantification is crucial. The method presented here is a concise in-series procedure with minimal measurements, eliminating large compounding errors. Sample preparation consists of a starch extraction employing enzymatic hydrolysis followed by a simple filtration and wash. The samples are then subjected to a two-stage acid hydrolysis. The concentration of glucose is determined by ion exchange high-performance liquid chromatography with a Pb 2+ column and a refractive index detector. The cellulosic glucan content is calculated based on the initial dry weight of the starting material. Data for the native biomass materials studied show excellent reproducibility, with coefficients of variance of 3.0% or less associated with the method. This selectivity for cellulosic glucan by the procedure was validated with several analytical techniques such as liquid chromatography coupled with mass spectrometry (LC–MS), Raman spectroscopy, and nuclear magnetic resonance.

09 BIOMASS FUELS↗

Taming nuclear mass models with Gaussian processes

We propose a new set of nuclear mass predictions based on multiple theoretical mass models. By employing Gaussian process regression with the Matérn kernel, we achieved root-mean-square (rms) deviations below 100 keV for the training dataset. The best-performing mass models achieved rms deviations below 150 keV for the new precise mass data from AME2020, whereas the ensemble average showed robust performance across the nuclear chart. Our approach uniquely combines: (1) systematic refinement of eight mass models through their residuals, (2) physics-informed features, including magic numbers, nucleon parity numbers, neutron excess, and nuclear collectivity, and (3) theory-to-theory validation demonstrating robust extrapolation capability. We find that the Matérn kernel provides superior uncertainty quantification compared to the RBF kernel, with a length-scale analysis revealing enhanced inter-nuclei correlations. We provide complete mass predictions for all unknown nuclides in AME2020, offering valuable constraints for nuclear structure studies and astrophysical modeling when used with proper uncertainty propagation.

Gaussian processes↗