Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

A new method for quantifying 64 Cu in nuclear debris samples

Quantifying 64 Cu in post-detonation nuclear debris samples can provide important diagnostic information regarding the structural materials used within a nuclear device. However, this task is challenging due to the weak gamma emissions associated with the decay of 64 Cu, its short half-life (12.701 h), and the presence of interfering fission product radioisotopes. Large quantities of debris sample are generally needed to accurately quantify 64 Cu, which can be problematic in sample-limited scenarios where other radiometric analyses are required. Herein, we present a new method for the separation of 64 Cu from solutions of mixed fission products and demonstrate the quantification of its activity through use of gas-flow proportional beta counting. Here, the new method was validated through a series of rigorous tests and was shown to improve the detection limit of 64 Cu by over two orders of magnitude, from 2.5 × 10 6 to 1.3 × 10 4 atoms/sample for 100 min measurements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effect of cation distribution on the magnetic and hyperfine behaviour of nanocrystalline Co doped Ni–Zn ferrite (Ni{sub 0.4}Zn{sub 0.4}Co{sub 0.2}Fe{sub 2}O{sub 4})

Highlights: • Cation distribution in tetrahedral and octahedral sites of spinel Ni{sub 0.4}Zn{sub 0.4}Co{sub 0.2}Fe{sub 2}O{sub 4}. • Structural analysis of observed X-ray diffraction pattern using Rietveld method. • Study of hyperfine behaviour using Mössbauer spectroscopy. • Static and dynamic magnetic measurements. • Correlation of cation distributions obtained from Rietveld analysis with the results of magnetic and Mössbauer effect measurements. - Abstract: Nanoparticles of Ni{sub 0.4}Zn{sub 0.4}Co{sub 0.2}Fe{sub 2}O{sub 4} are prepared by a simple co-precipitation method. The as dried sample is heat treated at 400, 500, 600, 700 and 800 °C to obtain different sizes of nanoparticles. The crystallographic phase of the samples is confirmed analyzing observed X-ray diffraction (XRD) by Rietveld method. Hyperfine parameters of the samples are derived from room temperature (RT) Mössbauer spectra of the samples. Magnetic properties of the samples are investigated by static and dynamic hysteresis loops. Different magneto-crystalline parameters are calculated from the variation of magnetization with temperature (M–T curve) under zero field cooled (ZFC) and field cooled (FC) conditions of the as dried sample. The cation distribution estimated from Rietveld analysis are correlated with the results of magnetic and Mössbauer effect measurements. The observed high value of saturation magnetization (72.7 emu/g at RT) of the sample annealed at 800 °C would be interesting for applications in different electromagnetic devices.

36 MATERIALS SCIENCE↗

Measuring the Stokes parameters of radiation of semiconductor lasers

We have developed and tested an original method for measuring the Stokes parameters for semiconductor lasers, based on the binding of the coordinate system to the test sample. The proposed method, when using an arbitrary phase plate as a compensator, allows one to measure the polarisation characteristics of lasers operating in a wide range of wavelengths - from 600 to 1000 nm. Application of the Fourier analysis to the quasi-continuous experimental data obtained with the help of automated systems of acquisition and processing of measurement results and ordinary optical elements provides accuracy that is sufficient to record the peculiarities of the polarisation characteristics of modern laser diodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Decomposing a San Francisco estuary microbiome using long-read metagenomics reveals species- and strain-level dominance from picoeukaryotes to viruses

ABSTRACT Although long-read sequencing has enabled obtaining high-quality and complete genomes from metagenomes, many challenges still remain to completely decompose a metagenome into its constituent prokaryotic and viral genomes. This study focuses on decomposing an estuarine metagenome to obtain a more accurate estimate of microbial diversity. To achieve this, we developed a new bead-based DNA extraction method, a novel bin refinement method, and obtained 150 Gbp of Nanopore sequencing. We estimate that there are ~500 bacterial and archaeal species in our sample and obtained 68 high-quality bins (>90% complete, <5% contamination, ≤5 contigs, contig length of >100 kbp, and all ribosomal and tRNA genes). We also obtained many contigs of picoeukaryotes, environmental DNA of larger eukaryotes such as mammals, and complete mitochondrial and chloroplast genomes and detected ~40,000 viral populations. Our analysis indicates that there are only a few strains that comprise most of the species abundances. IMPORTANCE Ocean and estuarine microbiomes play critical roles in global element cycling and ecosystem function. Despite the importance of these microbial communities, many species still have not been cultured in the lab. Environmental sequencing is the primary way the function and population dynamics of these communities can be studied. Long-read sequencing provides an avenue to overcome limitations of short-read technologies to obtain complete microbial genomes but comes with its own technical challenges, such as needed sequencing depth and obtaining high-quality DNA. We present here new sampling and bioinformatics methods to attempt decomposing an estuarine microbiome into its constituent genomes. Our results suggest there are only a few strains that comprise most of the species abundances from viruses to picoeukaryotes, and to fully decompose a metagenome of this diversity requires 1 Tbp of long-read sequencing. We anticipate that as long-read sequencing technologies continue to improve, less sequencing will be needed.

Lui, Lauren M.↗

Characterization and photocatalytic activity of Bi{sub 3}TaO{sub 7} prepared by hydrothermal method

In this paper, Bi{sub 3}TaO{sub 7} nanoparticles with visible light response have been prepared via a facile hydrothermal route and solid-state reaction. The photocatalytic performance of as-prepared samples was evaluated by the degradation of Tetracycline hydrochloride (TC). It was observed that the sample obtained by hydrothermal method showed an enhanced photocatalytic activity in contrast to the sample prepared by solid-state method. This could be ascribed to the efficient separation of photogenerated electrons and holes in the sample prepared via hydrothermal process, which is certified by the photoluminescence spectroscopy (PL) and transient photocurrent analysis. Moreover, the result of nitrogen adsorption-desorption isotherm indicated the existence of mesoporous structure in as-prepared sample with hydrothermal process, and specific surface area is significantly higher than the sample obtained by solid-state method. The optimal conditions involved in the photocatalytic reaction, such as TC concentration, catalyst concentration and pH value were investigated. - Graphical abstract: The preparation process of Bi{sub 3}TaO{sub 7} photocatalyst by hydrothermal method. Display Omitted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Drop-on-demand sample delivery for studying biocatalysts in action at X-ray free-electron lasers

X-ray crystallography at X-ray free-electron laser (XFEL) sources is a powerful method for studying macromolecules at biologically relevant temperatures. Moreover, when combined with complementary techniques like X-ray emission spectroscopy (XES), both global structures and chemical properties of metalloenzymes can be obtained concurrently, providing new insights into the interplay between the protein structure/dynamics and chemistry at an active site. However, implementing such a multimodal approach can be compromised by conflicting requirements to optimize each individual method. In particular, the method used for sample delivery greatly impacts the data quality. We present here a new, robust way of delivering controlled sample amounts on demand using acoustic droplet ejection coupled with a conveyor belt drive that is optimized for crystallography and spectroscopy measurements of photochemical and chemical reactions over a wide range of time scales. Studies with photosystem II, the phytochrome photoreceptor, and ribonucleotide reductase R2 illustrate the power and versatility of this method.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of sample treatments on genome recovery via single-cell genomics

It is known that single-cell genomics is a powerful tool for accessing genetic information from uncultivated microorganisms. Methods of handling samples before single-cell genomic amplification may affect the quality of the genomes obtained. Using three bacterial strains we demonstrate that, compared to cryopreservation, lower-quality single-cell genomes are recovered when the sample is preserved in ethanol or if the sample undergoes fluorescence in situ hybridization, while sample preservation in paraformaldehyde renders it completely unsuitable for sequencing.

59 BASIC BIOLOGICAL SCIENCES↗

Adaptive-in-temperature method for fast on-the-fly sampling of thermal neutron scattering data in MCNP6 [Slides]

The project objective and motivation is to develop thermal data libraries for selected isotopes in MCNP6 to support on-the-fly S(alpha, beta) sampling for temperature ranges applicable to nuclear criticality safety, thereby enhancing the physics treatment in MCNP6 so that it can perform fast on-the-fly sampling of S(alpha, beta) data at arbitrary temperature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modular droplet injector for sample conservation providing new structural insight for the conformational heterogeneity in the disease-associated NQO1 enzyme

Droplet injection strategies are a promising tool to reduce the large amount of sample consumed in serial femtosecond crystallography (SFX) measurements at X-ray free electron lasers (XFELs) with continuous injection approaches. Here, we demonstrate a new modular microfluidic droplet injector (MDI) design that was successfully applied to deliver microcrystals of the human NAD(P)H:quinone oxidoreductase 1 (NQO1) and phycocyanin. We investigated droplet generation conditions through electrical stimulation for both protein samples and implemented hardware and software components for optimized crystal injection at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Stanford Linac Coherent Light Source (LCLS). Under optimized droplet injection conditions, we demonstrate that up to 4-fold sample consumption savings can be achieved with the droplet injector. In addition, we collected a full data set with droplet injection for NQO1 protein crystals with a resolution up to 2.7 Å, leading to the first room-temperature structure of NQO1 at an XFEL. NQO1 is a flavoenzyme associated with cancer, Alzheimer's and Parkinson's disease, making it an attractive target for drug discovery. Further, our results reveal for the first time that residues Tyr128 and Phe232, which play key roles in the function of the protein, show an unexpected conformational heterogeneity at room temperature within the crystals. These results suggest that different substates exist in the conformational ensemble of NQO1 with functional and mechanistic implications for the enzyme's negative cooperativity through a conformational selection mechanism. Our study thus demonstrates that microfluidic droplet injection constitutes a robust sample-conserving injection method for SFX studies on protein crystals that are difficult to obtain in amounts necessary for continuous injection, including the large sample quantities required for time-resolved mix-and-inject studies.

59 BASIC BIOLOGICAL SCIENCES↗

Specific methodology for capacitance imaging by atomic force microscopy: A breakthrough towards an elimination of parasitic effects

On the basis of a home-made nanoscale impedance measurement device associated with a commercial atomic force microscope, a specific operating process is proposed in order to improve absolute (in sense of “nonrelative”) capacitance imaging by drastically reducing the parasitic effects due to stray capacitance, surface topography, and sample tilt. The method, combining a two-pass image acquisition with the exploitation of approach curves, has been validated on sets of calibration samples consisting in square parallel plate capacitors for which theoretical capacitance values were numerically calculated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Efficient Optimization of Plasma Radiation Detector Configurations using Imperfect Inference Models

The configurations of instruments fielded on an experiment affect the amount of information captured and the quality of subsequent inference. Here, we investigate the problem of optimizing plasma x-ray radiation detectors in a magneto-inertial fusion experiment at Sandia National Laboratories. It is impossible to directly measure properties such as the temperature of the thermonuclear fusion plasma produced in these experiments because of the extreme environment and destructive nature of the experiment. Among other diagnostics, several detectors are placed with significant standoff from the fusion target to capture the x-rays emitted by the fusion plasma, which can be used to infer some of its properties. To optimize the configuration of these detectors, a high-fidelity model (HFM) is used for simulating outputs and a low-fidelity model (LFM) is used for inference. We develop methods based on A- and L-optimality criteria that are efficient to compute while explicitly accounting for the discrepancy between the HFM and the LFM. The method allows us to find detector configurations that perform similarly to or better than the configuration obtained using an existing sampling-based optimization method while decreasing computational time by a factor of 50. Supplementary materials for this article are available online, including a standardized description of the materials available for reproducing the work.

Bayesian optimization↗

Exact and inexact subsampled Newton methods for optimization

Abstract The paper studies the solution of stochastic optimization problems in which approximations to the gradient and Hessian are obtained through subsampling. We first consider Newton-like methods that employ these approximations and discuss how to coordinate the accuracy in the gradient and Hessian to yield a superlinear rate of convergence in expectation. The second part of the paper analyzes an inexact Newton method that solves linear systems approximately using the conjugate gradient (CG) method, and that samples the Hessian and not the gradient (the gradient is assumed to be exact). We provide a complexity analysis for this method based on the properties of the CG iteration and the quality of the Hessian approximation, and compare it with a method that employs a stochastic gradient iteration instead of the CG method. We report preliminary numerical results that illustrate the performance of inexact subsampled Newton methods on machine learning applications based on logistic regression.

Mathematics↗

The XMM Cluster Survey analysis of the SDSS DR8 redMaPPer catalogue: implications for scatter, selection bias, and isotropy in cluster scaling relations

ABSTRACT In this paper, we present the X-ray analysis of Sloan Digital Sky Survey DR8 redMaPPer (SDSSRM) clusters using data products from the XMM Cluster Survey (XCS). In total, 1189 SDSSRM clusters fall within the XMM–Newton footprint. This has yielded 456 confirmed detections accompanied by X-ray luminosity (LX) measurements. Of these clusters, 381 have an associated X-ray temperature measurement (TX). This represents one of the largest samples of coherently derived cluster TX values to date. Our analysis of the X-ray observable to richness scaling relations has demonstrated that scatter in the TX–λ relation is roughly a third of that in the LX–λ relation, and that the LX–λ scatter is intrinsic, i.e. will not be significantly reduced with larger sample sizes. Analysis of the scaling relation between LX and TX has shown that the fits are sensitive to the selection method of the sample, i.e. whether the sample is made up of clusters detected ‘serendipitously’ compared to those deliberately targeted by XMM. These differences are also seen in the LX–λ relation and, to a lesser extent, in the TX–λ relation. Exclusion of the emission from the cluster core does not make a significant impact on the findings. A combination of selection biases is a likely, but yet unproven, reason for these differences. Finally, we have also used our data to probe recent claims of anisotropy in the LX–TX relation across the sky. We find no evidence of anistropy, but stress this may be masked in our analysis by the incomplete declination coverage of the SDSS.

79 ASTRONOMY AND ASTROPHYSICS↗

Superhard Nanostructured Ceramic–Metal Coatings with a Low Macrostress Level

The macrostressed state of (Ti,Al)N–Cu and (Ti,Al)N–Ni ceramic–metal coatings obtained by the arc-PVD method has been studied using X-ray diffraction and by measuring the radius of curvature of a coating–base composite sample (Stoney’s method). It is established that the presence of a tough metal phase favors significant reduction in the level of macrostresses in these structures as compared to those in (Ti,Al)N ceramic coatings, the absolute values of which decrease from 4.7–4.3 to 0.17–0.32 GPa. At the same time, both Ti–Al–Cu–N and Ti–Al–Ni–N coatings retain high hardness of 43 and 51 GPa, respectively, versus 29 GPa for Ti–Al–N coatings. The obtained results give grounds to suppose that the high hardness of the ceramic–metal coatings studied is determined by their nanocrystalline structure rather than by compressive macrostresses.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Coal Fired Power Plant Configuration and Operation Impact on Plant Effluent Contaminants and Conditions

The primary objective of this project is to characterize coal contaminants in coal-fired power plant wastewater as a function of coal type, unit configurations, and unit operation profile with uncertainty analysis. This project was in response to the U.S. Department of Energy (DOE) Solicitation DE-FOA-0001842. The project duration was between September 01, 2018, and December 31, 2021 (no-cost extension filed, due to the Covid-19 pandemic restrictions, and approved). Field and lab test program was conducted with the main goal to characterize coal contaminants in coal-fired power plant wastewater as a function of coal type, unit configurations, and unit operation profile with uncertainty analysis. In this project, the team of Lehigh University (prime recipient) and Western Kentucky University identified two suitable Thermoelectric Power Plants (TTPs) firing bituminous and sub-bituminous coals respectively, designed test plans, and performed sample collection. Sampling included coal from each TTPs power generation units, Wet Flue Gas Desulfurization (WFGD) slurry material and waste-water samples taken from the outlet of the water treatment tank prior to discharge and other pertinent locations. Coal samples are dried, crushed, and pulverized according to the American Society for Testing and Materials (ASTM) methods. The prepared coal samples are analyzed for normal proximate and ultimate analysis tests in addition to the toxic metals and anions according to ASTM methods. The FGD slurry materials are analyzed for toxic metals and anions according to Electric Power Research Institute (EPRI) or Environmental Protection Agency (EPA) methods, as appropriate. The wastewater samples from the water treatment tank outlet are analyzed for toxic metals and anions according to EPA methods. The effluent species analyzed include mercury, arsenic, selenium, nitrate/nitrite, bromide, and chlorine. This project provided results of effluent conditions as a function of coal type, unit configuration, and unit operation profile, and identified the levels of uncertainty in the effluent results.

01 COAL, LIGNITE, AND PEAT↗

Estimation of Cloud Fraction Profile in Shallow Convection Using a Scanning Cloud Radar

Large spatial heterogeneities in shallow convection result in uncertainties in estimations of domain-averaged cloud fraction profiles (CFP). This issue is addressed using large eddy simulations of shallow convection over land coupled with a radar simulator. Results indicate that zenith profiling observations are inadequate to provide reliable CFP estimates. Use of Scanning Cloud Radar (SCR), performing a sequence of cross-wind horizon-to-horizon scans, is not straightforward due to the strong dependence of radar sensitivity to target distance. An objective method for estimating domain-averaged CFP is proposed that uses observed statistics of SCR hydrometeor detection with height to estimate optimum sampling regions. This method shows good agreement with the model CFP. Results indicate that CFP estimates require more than 35 min of SCR scans to converge on the model domain average. Lastly, the proposed technique is expected to improve our ability to compare model output with cloud radar observations in shallow cumulus cloud conditions.

54 ENVIRONMENTAL SCIENCES↗

Optimization of In-Field Alpha Spectrometry for Uranium Enrichment Determination in Uranium Hexafluoride

In response to needs identified by the International Atomic Energy Agency (IAEA) research is underway to develop In-Field Alpha Spectrometry (IFAS) as a method to allow IAEA safeguards inspectors to collect samples of uranium hexafluoride (UF6) at processing facilities to assess and verify uranium enrichment. For sample collection, the IFAS method uses Single-Use Destructive Assay (SUDA) samplers, which contain thin zeolite coatings that trap UF6 gas and convert it to the safer, more stable form uranyl fluoride (UO2F2). For alpha spectrometry, the IFAS instrument employs a large area silicon semiconductor transducer to detect and record alpha particle energy-deposition events. Over the past year optimization work has significantly increased the diameter of useful SUDA samples (from 12.7 mm to 48 mm), improved the manufacturability and reproducibility of SUDA samples, increased the area of the IFAS alpha spectrometer sensor from 1.2 cm to 3.1 cm, and improved source positioning within the IFAS. This paper will report on this optimization work, its impacts on IFAS performance, and future plans for IFAS miniaturization, improvements, and testing.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Evaluation of Different Soil Carbon Determination Methods

Determining soil carbon (C) with high precision is an essential requisite for the success of the terrestrial C sequestration program. The informed choice of management practices for different terrestrial ecosystems rests upon accurately measuring the potential for C sequestration. Numerous methods are available for assessing soil C. Chemical analysis of field-collected samples using a dry combustion method is regarded as the standard method. However, conventional sampling of soil and their subsequent chemical analysis is expensive and time consuming. Furthermore, these methods are not sufficiently sensitive to identify small changes over time in response to alterations inmanagement practices or changes in land use. Presently, several different in situ analytic methods are being developed purportedly offering increased accuracy, precision and cost-effectiveness over traditional ex situ methods. We consider that, at this stage, a comparative discussion of different soil C determination methods will improve the understanding needed to develop a standard protocol.

54 ENVIRONMENTAL SCIENCES↗