Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Multimodal Mass Spectrometry Imaging (MSI) of Archean and Jurassic Geologic Samples

Current geochemical analytical techniques such as gas chromatography-mass spectrometry (GC-MS and $G\acute{C}GC-MS$) can effectively determine the composition and structure of the organic biosignatures within a sample but cannot resolve the spatial distribution of organic biosignatures within rocks or sediments. The spatial distribution can be used to determine the character of the organic biosignatures [1], which can be indigenous (deposited with host rocks), non-indigenous (incorporated after deposition via fluid migration), or contaminant. Determining the character of organic biosignatures is critical for ancient samples [2] and will be critical if organics are observed in samples returned from Mars [3].Fs-LDPI-MS has the ability to map organic compounds across the surface of samples at 2 - 10 μm lateral resolution. Furthermore, fs-LDPI-MS can be used to carry out multiple analyses in the same location for micron-scale analysis of previously buried material [4]. We used fs-LDPI-MS to examine a ~164 million year old organic-rich mudstone from SW England (14.2 wt. % total organic carbon) [5] and determined the spatial distribution of likely indigenous components buried below potentially contaminated surface layers.We then used ToF-SIMS to re-analyze the mudstone to directly compare ToF-SIMS to fs-LDPI-MS datasets, and to analyze a series of ~2.7 billion year old geologic samples from Timmins, ON, CA [6]. Ref. [6] previously analyzed the Archean samples and observed a series of archaeal biomarkers, as well as hopanes and steranes. Using ToF-SIMS analysis, we were able to detect hopanes and steranes in the mudstone samples, but not in the Archean samples indicating that the hopanes and steranes are most likely contaminants in the Archean samples. We also did not observe the archaeal biomarkers; however, this may be from the lack of molecular ion preservation during ToF-SIMS.

Pasterski, Michael↗

Inversion layer solar cell fabrication and evaluation

Silicon solar cells with induced junctions were created by forming an inversion layer near the surface of the silicon by supplying a sheet of positive charge above the surface. This charged layer was supplied through three mechanisms: (1) supplying a positive potential to a transparent electrode separated from the silicon surface by a dielectric, (2) contaminating the oxide layer with positive ions, and (3) forming donor surface states that leave a positive charge on the surface. A movable semi-infinite shadow delineated the extent of sensitivity of the cell due to the inversion region. Measurements of the inversion layer cell response to light of different wavelengths indicated it to be more sensitive to the shorter wavelengths of the sun's spectrum than conventional cells. Theory of the conductance of the inversion layer vs. strength of the inversion layer was compared with experiment and found to match. Theoretical determinations of junction depth and inversion layer strength were made as a function of the surface potential for the transparent electrode cell.

Call, R. L.↗

Inversion layer solar cell fabrication and evaluation

Silicon solar cells operating with induced junctions rather than diffused junctions have been fabricated and tested. Induced junctions were created by forming an inversion layer near the surface of the silicon by supplying a sheet of positive charge above the surface. This charged layer was supplied through three mechanisms: (1) applying a positive potential to a transparent electrode separated from the silicon surface by a dielectric, (2) contaminating the oxide layer with positive ions, and (3) forming donor surface states that leave a positive charge on the surface. A movable semi-infinite shadow delineated the extent of sensitivity of the cell due to the inversion region. Measurements of the response of the inversion layer cell to light of different wavelengths indicated it to be more sensitive to the shorter wavelengths of the sun's spectrum than conventional cells. The greater sensitivity occurs because of the shallow junction and the strong electric field at the surface.

Call, R. L.↗

Properties Data for Adhesion and Surface Chemistry of Aluminum: Sapphire-Aluminum, Single-Crystal Couple

An investigation was conducted to examine the adhesion and surface chemistry of single-crystal aluminum in contact with single-crystal sapphire (alumina). Pull-off force (adhesion) measurements were conducted under loads of 0. I to I mN in a vacuum of 10(exp -1) to 10(exp -9) Pa (approx. 10(exp -10) to 10(exp -11) torr) at room temperature. An Auger electron spectroscopy analyzer incorporated directly into an adhesion-measuring vacuum system was primarily used to define the chemical nature of the surfaces before and after adhesion measurements. The surfaces were cleaned by argon ion sputtering. With a clean aluminum-clean -sapphire couple the mean value and standard deviation of pull-off forces required to separate the surfaces were 3015 and 298 micro-N, respectively. With a contaminated aluminum-clean sapphire couple these values were 231 and 241 micro-N. The presence of a contaminant film on the aluminum surface reduced adhesion by a factor of 13. Therefore, surfaces cleanliness, particularly aluminum cleanliness, played an important role in the adhesion of the aluminum-sapphire couples. Pressures on the order of 10(exp -8) to 10(exp -9) Pa (approx. 10(exp -10) to 10(exp -11) torr) maintained a clean aluminum surface for only a short time (less then 1 hr) but maintained a clean sapphire surface, once it was achieved, for a much longer time.

Miyoshi, Kazuhisa↗

What Lies Beneath Can Be Imaged

The Hanford Site was quickly established to help end World War II, making history for producing the plutonium used in the world’s first nuclear weapons. Throughout the Cold War years, Hanford employees produced plutonium for most of the more than 60,000 weapons in the U.S. nuclear arsenal stockpile. Today, the once highly active nuclear reactors are shut down. And the mission at Hanford turned full-circle as scientists, engineers and specialists work to clean up our nation’s most contaminated nuclear site. PNNL Computational Geophysicist Tim Johnson is helping decision-makers understand the complexity and breadth of the contamination in soils at Hanford. Tim and others are applying remote, high-resolution geophysical imaging to determine the extent of contamination in the soil below the surface and understand the processes controlling its movement. They also provide real-time imaging of remediation processes that are working to limit the movement of contaminants below the surface and toward water resources. Geophysical imaging simply means that PNNL scientists are combining the techniques of geology, physics, mathematics and chemistry with supercomputer modeling to create three-dimensional images of the waste and its movement. These real-time, remote images are essential in reducing the uncertainty associated with cleanup costs and remediation technologies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The fraction of total hand surface area involved in young children's outdoor hand-to-object contacts

Information on the fraction of total hand surface area touching a contaminated object is necessary in accurately estimating contaminant (e.g., pesticides, pathogens) loadings onto the hands during hand-to-object contacts. While several existing physical-stochastic human exposure models require such surface area data to estimate dermal and non-dietary ingestion exposure, there are very limited data sets. This paper provides statistical distributions of fractional surface areas (FSAs) for children's outdoor hand contacts. These distributions were constructed by combining information collected from two distinct studies exploring children's activity patterns and quantifying hand contact surface area. Results show that for outdoor contacts with 'All Objects', a range of 0.13-0.27 captured median FSAs, while a range of 0.12-0.24 captured time-weighted FSAs. Overall, an FSA of 0.31 captured 80-100% of FSAs involved in each child's outdoor hand contacts, depending upon the object of interest. These values are much lower than the often conservative assumptions of up to 1 (i.e., the entire hand) that researchers currently make regarding FSAs involved in indoor and outdoor contacts [USEPA, 1997. Standard operating procedures (SOPs) for residential exposure assessments. Contract no. 68-W6-0030. < (http://www.epa.gov/pesticides/trac/science/trac6a05.pdf)>].

60 APPLIED LIFE SCIENCES↗

In Situ Measurements of the Reflectances of the LSSTCam Optics and Assessing the Impact of Optical Ghosts

Optical ghosts are image artifacts caused by successive reflections of light between optical surfaces such as lenses, filters, and detectors. These artifacts are unavoidable due to the nonzero reflectances of optical elements and are a major source of contamination for low-surface-brightness science. We use optical ray tracing simulations tuned to observations from LSST Commissioning to quantify the impact of optical ghosts on the LSST data. In particular, we find that ~0.57% of the LSSTCam focal plane is impacted by optical ghosts when averaged across all bands. We also use data from the Collimated Beam Projector to measure the reflectances of various optical elements, generally confirming estimates of ~2% from the systems engineering throughput predictions.

Pai, Aashay↗

Calendar Year 2008 Groundwater Monitoring Report, U.S. Department of Energy Y-12 National Security Complex, Oak Ridge, Tennessee

This report contains the groundwater and surface water monitoring data that were obtained during calendar year (CY) 2008 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (hereafter referenced as Y-12) on the DOE Oak Ridge Reservation (ORR) in Oak Ridge, Tennessee. The CY 2008 monitoring data were obtained from wells, springs, and surface water sampling locations in three hydrogeologic regimes at Y-12 (Figure A.1). The Bear Creek Hydrogeologic Regime (Bear Creek Regime) encompasses a section of Bear Creek Valley (BCV) between the west end of Y-12 and the west end of the Bear Creek Watershed (directions are in reference to the Y-12 grid system). The Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime) encompasses the Y-12 industrial facilities and support structures in BCV. The Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime) encompasses a section of Chestnut Ridge directly south of Y-12. Section 2 of this report provides background information pertinent to groundwater and surface water quality monitoring in each hydrogeologic regime, including the topography and bedrock geology, surface water drainage, groundwater system, and extent of groundwater contamination. The CY 2008 groundwater and surface water monitoring data in this report were obtained from sampling and analysis activities implemented under the Y-12 Groundwater Protection Program (GWPP) managed by Babcock & Wilcox Technical Services Y-12, LLC (B&W Y-12) and from sampling and analysis activities implemented under several monitoring programs managed by Bechtel Jacobs Company LLC (BJC). Cooperative implementation of the monitoring programs directed by the Y-12 GWPP and BJC (i.e., coordinating sample collection and sharing data) ensures that the CY 2008 monitoring results fulfill requirements of all the applicable monitoring drivers with no duplication of sampling and analysis efforts. Section 3 of this report contains a summary of information regarding the groundwater and surface water sampling and analysis activities implemented under the Y-12 GWPP including sampling locations and frequency; quality assurance (QA)/quality control (QC) sampling; sample collection and handling; field measurements and laboratory analytes; data management and data quality objective (DQO) evaluation; and groundwater elevation monitoring. However, this report does not include equivalent QA/QC or DQO evaluation information regarding the groundwater and surface water sampling and analysis activities associated with the monitoring programs implemented by BJC. Such details are deferred to the respective programmatic plans and reports issued by BJC (see Section 3.0).

54 ENVIRONMENTAL SCIENCES↗

A Survey of Environmental Microbial Flora During Closed Chamber Studies

Services, Inc. and NASA Johnson Space Center, Houston, TX As NASA prepares for long-term missions aboard the International Space Station and the eventual exploration of Mars, closed-environment chambers on Earth have become important test beds for systems evaluations. During 2 separate studies of a selfcontained ecosystem containing 4 crewmembers, microbial surveys of samples from 13 surface and 3 air sites were performed. Microbial concentration of samples from surface sites with frequent water contact (e.g., urinal, sink) did not indicate significantly higher levels of contamination than drier areas, though surface cleaning by the crew may have influenced this conclusion. Changes in bacterial diversity on surface sites implied that the number of transient species was high, suggesting movement by crew activities, aerosols, or both. A non-linear relationship between bacterial diversity and enumeration from surface samples indicated that a rapid increase occurred in the number of species as cell concentration increased to 5 CFU/sq cm. Above this concentration, the number of different bacterial species varied between 11 and 16. Airborne bacteria and fungi averaged only 160 and 1 CFU/m3, respectively. Microbial contamination of the potable water system primarily consisted of 3 species of Gram negative bacteria; however, after 60 days during one study, several species of Bacillus became the dominant flora. This study suggests that under these conditions, microbial contamination in the air and water was suppressed by the life-support systems, though contamination was possible. Conversely, the crew and their activities controlled microbial levels on surfaces. Understanding the factors that affect microbial control will improve the design of microbial testing both during space flight and in analogous Earth-based environments.

Ott, C. Mark↗

Peptoid-Loaded Microgels Self-Defensively Inhibit Staphylococcal Colonization of Titanium in a Model of Operating-Room Contamination

Bacterial contamination of an exposed implantable medical device by the atmosphere of an operating room (OR) is increasingly implicated as a cause of device-associated infection. Here, OR contamination is modeled in vitro using an aerosolizing system to spray small quantities of staphylococci onto titanium rods. Contaminated rods always manifest culturable bacteria. Self-assembly is used to create a self-defensive Ti surface that substantially enhances the rod's resistance to such contamination. Poly(acrylic acid) microgels are electrostatically deposited onto small Ti rods and subsequently loaded by complexation with a cationic antimicrobial peptoid (TM1). The microgels are visualized in situ by optical microscopy, and changes in microgel diameter indicate the loading state. Further, these measurements show that TM1 can be quickly loaded from low-ionic-strength buffer and subsequently remained sequestered within the microgels for up to 4 weeks when soaked in phosphate buffered saline. TM1-loaded microgel-modified Ti surfaces are contaminated with aerosolized staphylococci, and subsequent assays indicate few or no culturable bacteria. In the absence of nutrients to enable metabolism, this finding suggests that bacteria trigger local TM1 release by contact transfer. The modified surfaces exhibit good in vitro cytocompatibility as manifested by the adhesion, spreading, and metabolic activity of human fetal osteoblasts.

36 MATERIALS SCIENCE↗

The role of nanopores on U(VI) sorption and redox behavior in U(VI)-contaminated subsurface sediments

Most reactive surfaces in clay-dominated sediments are present within nanopores (pores of nm dimension). The behavior of geological fluids and minerals in nanopores is significantly different from those in normal non-nanoporous environments. The effect of nanopore surfaces on U(VI) sorption/desorption and reduction is likely to be significant in clay-rich subsurface environments. Our research results from both model nanopore system and natural sediments from both model system (synthetic nanopore alumina) and sediments from the ORNL Field Research Center prove that U(VI) sorption on nanopore surfaces can be greatly enhanced by nanopore confinement environments. The results from the project provide advanced mechanistic, quantitative information on the physiochemical controls on uranium sorption and redox behavior in subsurface sediments. The influence of nanopore surfaces on coupled uranium sorption/desorption and reduction processes is significant in virtually all subsurface environments, because most reactive surfaces are in fact nanopore surfaces. The results will enhance transfer of our laboratory-based research to a major field research initiative where reductive uranium immobilization is being investigated. Our results will also provide the basic science for developing in-situ colloidal barrier of nanoporous alumina in support of environmental remediation and long term stewardship of DOE sites.

54 ENVIRONMENTAL SCIENCES↗

IUS solid rocket motor contamination prediction methods

A series of computer codes were developed to predict solid rocket motor produced contamination to spacecraft sensitive surfaces. Subscale and flight test data have confirmed some of the analytical results. Application of the analysis tools to a typical spacecraft has provided early identification of potential spacecraft contamination problems and provided insight into their solution; e.g., flight plan modifications, plume or outgassing shields and/or contamination covers.

Mullen, C. R.↗

Suitport Feasibility - Development and Test of a Suitport and Space Suit for Human Pressurized Space Suit Donning Tests

The suitport concept has been recently implemented as part of the small pressurized lunar rover (Currently the Space Exploration vehicle, or SEV) and the Multi-Mission Space Exploration Vehicle (MMSEV) concept demonstrator vehicle. Suitport replaces or augments the traditional airlock function of a spacecraft by providing a bulkhead opening, capture mechanism, and sealing system to allow ingress and egress of a spacesuit while the spacesuit remains outside of the pressurized volume of the spacecraft. This presents significant new opportunities to EVA exploration in both microgravity and surface environments. The suitport concept will enable three main improvements in EVA by providing reductions in: pre-EVA time from hours to less than thirty minutes; airlock consumables; contamination returned to the cabin with the EVA crewmember. To date, the first generation suitport has been tested with mockup suits on the rover cabins and pressurized on a bench top engineering unit. The work on the rover cabin has helped define the operational concepts and timelines, and has demonstrated the potential of suitport to save significant amounts of crew time before and after EVAs. The work with the engineering unit has successfully demonstrated the pressurizable seal concept including the ability to seal after the introduction and removal of contamination to the sealing surfaces. Using this experience, a second generation suitport was designed. This second generation suitport has been tested with a spacesuit prototype using the pressure differentials of the spacecraft. This test will be performed using the JSC B32 Chamber B, a human rated vacuum chamber. This test will include human rated suitports, the suitport compatible prototype suit, and chamber modifications. This test will bring these three elements together in the first ever pressurized donning of a rear entry suit through a suitport. This paper presents design of a human rated second generation suitport, modifications to the JSC human rated chamber B to accept a suitport, and a compatible space suit to support pressurized human donning of the pressurized suit through a suitport. Design challenges and solutions and compromises required to develop the system are presented. Initial human testing results are presented.

Boyle, Robert M.↗

Suitport Feasibility: Development and Test of a Suitport and Space Suit for Human Pressurized Space Suit Donning Tests

The suitport concept has been recently implemented as part of the small pressurized lunar rover (Currently the Space Exploration vehicle, or SEV) and the Multi-Mission Space Exploration Vehicle (MMSEV) concept demonstrator vehicle. Suitport replaces or augments the traditional airlock function of a spacecraft by providing a bulkhead opening, capture mechanism, and sealing system to allow ingress and egress of a space suit while the space suit remains outside of the pressurized volume of the spacecraft. This presents significant new opportunities to EVA exploration in both microgravity and surface environments. The suitport concept will enable three main improvements in EVA by providing reductions in: pre-EVA time from hours to less than thirty minutes; airlock consumables; contamination returned to the cabin with the EVA crewmember. To date, the first generation suitport has been tested with mockup suits on the rover cabins and pressurized on a bench top engineering unit. The work on the rover cabin has helped define the operational concepts and timelines, and has demonstrated the potential of suitport to save significant amounts of crew time before and after EVAs. The work with the engineering unit has successfully demonstrated the pressurizable seal concept including the ability to seal after the introduction and removal of contamination to the sealing surfaces. Using this experience, a second generation suitport was designed. This second generation suitport has been tested with a space suit prototype on the second generation MMSEV cabin, and testing is planned using the pressure differentials of the spacecraft. Pressurized testing will be performed using the JSC B32 Chamber B, a human rated vacuum chamber. This test will include human rated suitports, a suitport compatible prototype suit, and chamber modifications. This test will bring these three elements together in the first ever pressurized donning of a rear entry suit through a suitport. This paper presents the design of a human rated second generation suitport, the design of a suit capable of supporting pressurized human donning through a suitport, ambient pressure testing of the suit with the suitport, and modifications to the JSC human rated chamber B to accept a suitport. Design challenges and solutions, as well as compromises required to develop the system, are presented. Initial human testing results are presented.

Boyle, Robert M.↗

Pulsed power accelerator surface Joule heating models

Understanding the effects of contaminant plasmas generated within the Z machine at Sandia is critical to understanding current loss mechanisms. The plasmas are generated at the accelerator electrode surfaces and include desorbed species found in the surface and substrate of the walls. These desorbed species can become ionized. The timing and location of contaminant species desorbed from the wall surface depend non-linearly on the local surface temperature. For accurate modeling, it is necessary to utilize wall heating models to estimate the amount and timing of material desorption. One of these heating mechanisms is Joule heating. In this paper, we propose several extended semi-analytic magnetic diffusion heating models for computing surface Joule heating and demonstrate their effects for several representative current histories. We quantitatively assess under what circumstances these extensions to classical formulas may provide a validatable improvement to the understanding of contaminant desorption timing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Relationships between PEMFC Cathode Kinetic Losses and Contaminants’ Dipole Moment and Adsorption Energy on Pt

A database summarizing the effects of 21 contaminants on the performance of proton exchange membrane fuel cells (PEMFCs) was used to examine relationships between cathode kinetic losses and contaminant physicochemical parameters. Impedance spectroscopy data were employed to obtain oxygen reduction kinetic resistances by fitting data in the 10-158 Hz range to a simplified equivalent circuit. The contaminant dipole moment and the adsorption energy of the contaminant on a Pt surface were chosen as parameters. Dipole moments did not correlate with dimensionless cathode kinetic resistances. In contrast, adsorption energies were quantitatively and linearly correlated with minimum dimensionless cathode kinetic resistances. Contaminants influence the oxygen reduction for contaminant adsorption energies smaller than -24.5 kJ mol -1 , a value near the high limit of the adsorption energy of O 2 on Pt. Dimensionless cathode kinetic resistances linearly increase with decreasing O 2 adsorption energies below -24.5 kJ mol -1 . Measured total cell voltage losses are mostly larger than the cathode kinetic losses calculated from kinetic resistance changes, which indicates the existence of other sources of performance degradation. Modifications to the experimental procedure are proposed to ensure that data are comparable on a similar basis and improve the correlation between contaminant adsorption energy and kinetic cell voltage losses.

25 ENERGY STORAGE↗

Molten Salt Corrosion Tests of Additively Manufactured Stainless Steel 316H

Molten salt reactors (MSRs) have drawn considerable interest due to their favorable safety features, high thermal efficiency, and compatibility with different fuel cycles. Yet, the success of MSRs hinges critically on the performance of structural materials to be used in these aggressive molten salt environments, where corrosion and material compatibility remain primary challenges to long-term reliability. Additively manufactured (AM) nuclear structural materials prompt the use of novel geometries and compositions to enhance material performance and reduce costs of constructing MSRs. The rapid solidification conditions inherent to AM processing impart distinctive microstructural features, including cellular sub-structures, dislocation densities, residual stress, and oxide inclusions, which can influence material performance in MSR components. While the mechanical properties of AM stainless steels have been widely studied, their corrosion behavior, particularly in molten salt environments, has received far less attention. Addressing these needs, the Advanced Materials and Manufacturing Technologies (AMMT) program provides a framework for systematically evaluating how unique microstructures produced by AM processes influence the performance of these materials in these demanding environments and for developing reproducible testing workflows that can support future code qualification efforts and standards development. Bridging this knowledge gap is essential for assessing the viability of AM alloys in MSRs and informing qualification strategies. A further challenge is the absence of standardized protocols for molten salt corrosion testing. Accordingly, this report provides an account of the corrosion evaluation of AM 316H stainless steel in NaCl 2 -MgCl 2 molten salt at 550 °C, with exposure times of 100 and 500 hours. It documents the experimental procedures implemented under the AMMT program, including salt preparation, exposure protocols, and post-test characterization methods, to establish reproducibility and transparency. Importantly, the study examines AM 316H samples in the as-fabricated condition, directly reflecting the surface state most relevant to engineering applications, and compares their behavior to machine-cut surfaces. Overall, preliminary evaluations have noted that surface conditions (e.g. morphology, contamination, etc.) have a noticeable impact on the corrosion resiliency. The impact of the corrosion is difficult to detect at 100h, unless, in the case of AM 316H, the specimen surface is decontaminated. After 500 h, as-fabricated surfaces of AM and wrought 316H display evidence of general versus preferential corrosion attack, respectively. Both AM and wrought 316H machine-cut surfaces exhibit a continuous Cr depletion zone, evident of general corrosion. While the estimated extent of corrosion appears within the same order of magnitude regardless of the surface condition, it is apparent that more predictable behavior is observed on machine-cut surfaces. Nonetheless, further investigation is necessary to fully elucidate the corrosion mechanism under these conditions.

36 - MATERIALS SCIENCE↗

An Evaluation of Long-Term Performance of Liner Systems for Low-Level Waste Disposal Facilities

Traditional liner systems consisting of a geosynthetic membrane underlying a waste disposal facility coupled with a leachate collection system have been proposed as a means of containing releases of low-level radioactive waste within the confines of the disposal facility and thereby eliminating migration of radionuclides into the vadose zone and groundwater. However, this type of hydraulic containment liner system is only effective as long as the leachate collection system remains functional or an overlying cover limits the total infiltration to the volumetric pore space of the disposal system. If either the leachate collection system fails, or the overlying cover becomes less effective during the 1,000’s of years of facility lifetime, the liner may fill with water and release contaminated water in a preferential or focused manner. If the height of the liner extends above the waste, the waste will become submerged which could increase the release rate and concentration of the leachate. If the liner extends near land surface, there is the potential for contamination reaching land surface creating a direct exposure pathway. Alternative protective liner systems can be engineered that eliminate radionuclide releases to the vadose zone during operations and minimizing long term migration of radionuclides from the disposal facility into the vadose zone and aquifer. Non-traditional systems include waste containerization in steel or composite materials. This type of system would promote drainage of clean infiltrating water through the facility without contacting the waste. Other alternatives include geochemical barriers designed to transmit water while adsorbing radionuclides beneath the facility. Facility performance for a hypothetical disposal facility has been compared for the hydraulic and steel containerization liner alternatives. Results were compared in terms of meeting the DOE Order 435.1 low-level waste performance objective of 25 mrem/yr all-pathways dose during the 1) institutional control period (0-100 years), compliance period (0-1000 years) and post-compliance period (>1000 years). Evaluation of the all pathway dose included the dose from ingestion and irrigation of contaminated groundwater extracted from a well 100 meters downgradient, in addition to the dose received from direct contact of radionuclides deposited near the surface resulting from facility overflow. Depending on the disposal facility radionuclide inventory, facility design, cover performance, and the location and environment where the facility is situated, the dose from exposure via direct contact of near surface deposited radionuclides can be much greater than the dose received via transport to the groundwater and subsequent ingestion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗