Search NASA⌕ Search

SEARCH · Search NASA

Results for “time synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

A Full Mesh ATCA-based General Purpose Data Processing Board (Pulsar II)

The Pulsar II is a custom ATCA full mesh enabled FPGA-based processor board which has been designed with the goal of creating a scalable architecture abundant in flexible, non-blocking, high bandwidth interconnections. The design has been motivated by silicon-based tracking trigger needs for LHC experiments. In this technical memo we describe the Pulsar II hardware and its performance, such as the performance test results with full mesh backplanes from different vendors, how the backplane is used for the development of low-latency time-multiplexed data transfer schemes and how the inter-shelf and intra-shelf synchronization works.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamical characteristics of Phobos and Deimos.

The orbital properties of the two small Martian satellites, Phobos and Deimos, are discussed, as well as those dynamical constants of Mars that can be determined from the satellite orbits. The secular acceleration of the mean motion of Phobos is shown to be very small. Of mechanisms that could cause any such acceleration, only tidal friction appears to be important. From the orbital evolution of the Martian satellites under tidal forces, Phobos and Deimos seem to have originated in nearly circular orbits of low inclination fairly close to the distance at which a satellite's orbital period is the planet's rotation period. It is proposed that the Martian satellites were born at the same time as Mars from equatorial dust clouds. The satellites are predicted to be locked in synchronous rotation, with their axes of minimum moment of inertia pointing on the average toward Mars, whereas their maximum axes are approximately normal to their orbit planes.

Burns, J. A.↗

Instrumentation for one-way satellite PTTI applications

A review of general principles and operational procedures illustrates how the typical passive user and omni receiving antenna can recover Precise Time and Time Interval (PTTI) information from a low altitude navigation satellite system for clock calibration and synchronization. Detailed discussions of concepts and theory of the receiver design are presented. The importance of RF correlation of the received and local PN encoded sequences is emphasized as a means of reducing delay uncertainties of the instrumentation to values compatible with nanosecond to submicrosecond PTTI objectives. Two receiver configurations were fabricated for use in satellite-to-laboratory experiments. In one receiver the delay-locked loop for PN signals synchronization used a dithered amplitude detection process while the second receiver used a complex sums phase detection method for measurement of delay error. The necessity for compensation of Doppler shift is discussed. Differences in theoretical signal acquisition and tracking performance of the design concepts are noted.

Osborne, A. E.↗

A study of the icy tails of the distant comets

Properties are studied of the icy grain model for the tails of comets Baade 1955 VI and Haro-Chavira 1956 I, which have large perihelion distances. The general profiles and orientations of the tails are compared with a set of synchrones, or theoretical trajectories of particles ejected from a cometary nucleus at given instants of time. Several features observed in these comets are shown to be explained by the icy grain model, including jet activity in the coma and no appreciable broadening of the tail with increasing distance from the nucleus. It is demonstrated that the transition region between 2 and 3 AU, where water snow begins to experience rapid evaporation, has a significant effect on the dynamics of icy tails. It is suggested that the icy grains constituting these cometary tails may carry fine particles of meteoric dust which are released when the grains begin to disintegrate by evaporation.

Sekanina, Z.↗

Satellite communication performance evaluation: Computational techniques based on moments

Computational techniques that efficiently compute bit error probabilities when only moments of the various interference random variables are available are presented. The approach taken is a generalization of the well known Gauss-Quadrature rules used for numerically evaluating single or multiple integrals. In what follows, basic algorithms are developed. Some of its properties and generalizations are shown and its many potential applications are described. Some typical interference scenarios for which the results are particularly applicable include: intentional jamming, adjacent and cochannel interferences; radar pulses (RFI); multipath; and intersymbol interference. While the examples presented stress evaluation of bit error probilities in uncoded digital communication systems, the moment techniques can also be applied to the evaluation of other parameters, such as computational cutoff rate under both normal and mismatched receiver cases in coded systems. Another important application is the determination of the probability distributions of the output of a discrete time dynamical system. This type of model occurs widely in control systems, queueing systems, and synchronization systems (e.g., discrete phase locked loops).

Omura, J. K.↗

Precluding nonlinear ISI in direct detection long-haul fiber optic systems

Long-distance, high-rate fiber optic systems employing directly modulated 1.55-micron single-mode lasers and conventional single-mode fiber suffer severe intersymbol interference (ISI) with a large nonlinear component. A method of reducing the nonlinearity of the ISI, thereby making linear equalization more viable, is investigated. It is shown that the degree of nonlinearity is highly dependent on the choice of laser bias current, and that in some cases the ISI nonlinearity can be significantly reduced by biasing the laser substantially above threshold. Simulation results predict that an increase in signal-to-nonlinear-distortion ratio as high as 25 dB can be achieved for synchronously spaced samples at an optimal sampling phase by increasing the bias current from 1.2 times threshold to 3.5 times threshold. The high SDR indicates that a linear tapped delay line equalizer could be used to mitigate ISI. Furthermore, the shape of the pulse response suggests that partial response precoding and digital feedback equalization would be particularly effective for this channel.

Swenson, Norman L.↗

General technique for discrete retardation-modulation polarimetry

The general theory and rigorous solutions of the Stokes parameters of light of a new technique in time-resolved ellipsometry are outlined. In this technique the phase of the linear retarder is stepped over three discrete values over a time interval for which the Stokes vector is determined. The technique has an advantage over synchronous detection techniques, as it can be implemented as a digitizable system.

Saxena, Indu↗

Inferences About the Early Moon from Gravity and Topography

Recent spacecraft missions to the Moon have significantly improved our knowledge of the lunar gravity and topography fields and have raised some new and old questions about the early lunar history. It has frequently been assumed that the shape of the Moon today reflects an earlier equilibrium state and that the Moon has retained some internal strength. Recent analysis indicating a superisostatic state of some lunar basins lends support to this hypothesis. On its simplest level the present shape of the Moon is slightly flattened by 2.2 +/- 0.2 km while its gravity field, represented by an equipotential surface, is flattened only about 0.5 km. The hydrostatic component to the flattening arising from the Moon's present-day rotation contributes only 7 m. This difference between the topographic shape of the Moon and the shape of its gravitational equipotential has frequently been explained as the "memory" of an earlier Moon that was rotating faster and had a correspondingly larger hydrostatic flattening. To obtain this amount of hydrostatic flattening from rotation alone, and accounting for the contribution of the present-day gravity field, the Moon's rotation rate would need to be about 15 times greater than at present leading to a period of under 2 days. Maintaining its synchronous rotation with Earth would require a radius for the Moon's orbit of order 9 earth radii. Unfortunately, our confidence in the observed lunar flattening is not as great as we would like.

Smith, David E.↗

Cameleon calcium indicator reports cytoplasmic calcium dynamics in Arabidopsis guard cells

Cytoplasmic free calcium ([Ca2+]cyt) acts as a stimulus-induced second messenger in plant cells and multiple signal transduction pathways regulate [Ca2+]cyt in stomatal guard cells. Measuring [Ca2+]cyt in guard cells has previously required loading of calcium-sensitive dyes using invasive and technically difficult micro-injection techniques. To circumvent these problems, we have constitutively expressed the pH-independent, green fluorescent protein-based calcium indicator yellow cameleon 2.1 in Arabidopsis thaliana (Miyawaki et al. 1999; Proc. Natl. Acad. Sci. USA 96, 2135-2140). This yellow cameleon calcium indicator was expressed in guard cells and accumulated predominantly in the cytoplasm. Fluorescence ratio imaging of yellow cameleon 2.1 allowed time-dependent measurements of [Ca2+]cyt in Arabidopsis guard cells. Application of extracellular calcium or the hormone abscisic acid (ABA) induced repetitive [Ca2+]cyt transients in guard cells. [Ca2+]cyt changes could be semi-quantitatively determined following correction of the calibration procedure for chloroplast autofluorescence. Extracellular calcium induced repetitive [Ca2+]cyt transients with peak values of up to approximately 1.5 microM, whereas ABA-induced [Ca2+]cyt transients had peak values up to approximately 0.6 microM. These values are similar to stimulus-induced [Ca2+]cyt changes previously reported in plant cells using ratiometric dyes or aequorin. In some guard cells perfused with low extracellular KCl concentrations, spontaneous calcium transients were observed. As yellow cameleon 2.1 was expressed in all guard cells, [Ca2+]cyt was measured independently in the two guard cells of single stomates for the first time. ABA-induced, calcium-induced or spontaneous [Ca2+]cyt increases were not necessarily synchronized in the two guard cells. Overall, these data demonstrate that that GFP-based cameleon calcium indicators are suitable to measure [Ca2+]cyt changes in guard cells and enable the pattern of [Ca2+]cyt dynamics to be measured with a high level of reproducibility in Arabidopsis cells. This technical advance in combination with cell biological and molecular genetic approaches will become an invaluable tool in the dissection of plant cell signal transduction pathways.

Non-NASA Center↗

Biomolecule Sequencer: Next-Generation DNA Sequencing Technology for In-Flight Environmental Monitoring, Research, and Beyond

On the International Space Station (ISS), technologies capable of rapid microbial identification and disease diagnostics are not currently available. NASA still relies upon sample return for comprehensive, molecular-based sample characterization. Next-generation DNA sequencing is a powerful approach for identifying microorganisms in air, water, and surfaces onboard spacecraft. The Biomolecule Sequencer payload, manifested to SpaceX-9 and scheduled on the Increment 4748 research plan (June 2016), will assess the functionality of a commercially-available next-generation DNA sequencer in the microgravity environment of ISS. The MinION device from Oxford Nanopore Technologies (Oxford, UK) measures picoamp changes in electrical current dependent on nucleotide sequences of the DNA strand migrating through nanopores in the system. The hardware is exceptionally small (9.5 x 3.2 x 1.6 cm), lightweight (120 grams), and powered only by a USB connection. For the ISS technology demonstration, the Biomolecule Sequencer will be powered by a Microsoft Surface Pro3. Ground-prepared samples containing lambda bacteriophage, Escherichia coli, and mouse genomic DNA, will be launched and stored frozen on the ISS until experiment initiation. Immediately prior to sequencing, a crew member will collect and thaw frozen DNA samples, connect the sequencer to the Surface Pro3, inject thawed samples into a MinION flow cell, and initiate sequencing. At the completion of the sequencing run, data will be downlinked for ground analysis. Identical, synchronous ground controls will be used for data comparisons to determine sequencer functionality, run-time sequence, current dynamics, and overall accuracy. We will present our latest results from the ISS flight experiment the first time DNA has ever been sequenced in space and discuss the many potential applications of the Biomolecule Sequencer for environmental monitoring, medical diagnostics, higher fidelity and more adaptable Space Biology Human Research Program investigations, and even life detection experiments for astrobiology missions.

Sequencer↗

Geodetic Reference Instrument Transponder for Small Satellites

The local ties between Satellite Laser Ranging stations and other collocated geodetic stations are an important component of the realization of the International Terrestrial Reference Frame but the survey accuracies are limited due to the inaccessibility of the instrument reference points. The NASA Geodetic Reference Instrument Transponder for Small Satellites (GRITSS) technology demonstration mission is designed to overcome this limitation by using a small satellite as a space-based reference point for tying together the measurement points of collocated geodetic stations. The GRITSS instrument upconverts the Global Positioning System (GPS) signals received at the satellite in real-time to S and X band and transmits them to a VLBI Global Observing System (VGOS) antenna ground station. The measurement observables do not require the satellite to be in view of more than one VLBI station at a time. The GRITSS demonstration mission utilizes a 12-UL CubeSat in a Low Earth, Sun Synchronous orbit. Tracking by the global ILRS network throughout the life of the mission is critical to establishing the space-based reference along with the precision orbit determination required by the measurement concept. Due to limitations in spacecraft power and other constraints, the initial phase of the mission will only broadcast the GRITSS VLBI signals twice a day to each of the NASA VGOS stations in Maryland, Hawaii, and Texas, but other international VGOS stations may be added during the second half of the mission. An overview of the GRITSS mission and measurement concept will be presented.

Stephen M Merkowitz↗

Experiments with Memory-to-Memory Coupling for End-to-End fusion Simulation Workflows

Scientific applications are striving to accurately simulate multiple interacting physical processes that comprise complex phenomena being modeled. Efficient and scalable parallel implementations of these coupled simulations present challenging interaction and coordination requirements, especially when the coupled physical processes are computationally heterogeneous and progress at different speeds. In this paper, we present the design, implementation and evaluation of a memory-to-memory coupling framework for coupled scientific simulations on high-performance parallel computing platforms. The framework is driven by the coupling requirements of the Center for Plasma Edge Simulation, and it provides simple coupling abstractions as well as efficient asynchronous (RDMA-based) memory-to-memory data transport mechanisms that complement existing parallel programming systems and data sharing frameworks. The framework enables flexible coupling behaviors that are asynchronous in time and space, and it supports dynamic coupling between heterogeneous simulation processes without enforcing any synchronization constraints. We evaluate the performance and scalability of the coupling framework using a specific coupling scenario, on the Jaguar Cray XT5 system at Oak Ridge National Laboratory.

99 GENERAL AND MISCELLANEOUS↗

TH-CD-201-10: Highly Efficient Synchronized High-Speed Scintillation Camera System for Measuring Proton Range, SOBP and Dose Distributions in a 2D-Plane

Purpose: Proton therapy (PT) delivery is complex and extremely dynamic. Therefore, quality assurance testing is vital, but highly time-consuming. We have developed a High-Speed Scintillation-Camera-System (HS-SCS) for simultaneously measuring multiple beam characteristics. Methods: High-speed camera was placed in a light-tight housing and dual-layer neutron shield. HS-SCS is synchronized with a synchrocyclotron to capture individual proton-beam-pulses (PBPs) at ∼504 frames/sec. The PBPs from synchrocyclotron trigger the HS-SCS to open its shutter for programmed exposure-time. Light emissions within 30×30×5cm3 plastic-scintillator (BC-408) were captured by a CCD-camera as individual images revealing dose-deposition in a 2D-plane with a resolution of 0.7mm for range and SOBP measurements and 1.67mm for profiles. The CCD response as well as signal to noise ratio (SNR) was characterized for varying exposure times, gains for different light intensities using a TV-Optoliner system. Software tools were developed to analyze ∼5000 images to extract different beam parameters. Quenching correction-factors were established by comparing scintillation Bragg-Peaks with water scanned ionization-chamber measurements. Quenching corrected Bragg-peaks were integrated to ascertain proton-beam range (PBR), width of Spared-Out-Bragg-Peak (MOD) and distal.

07 ISOTOPE AND RADIATION SOURCES↗

Performance Analysis of and Tool Support for Transactional Memory on BG/Q

Martin Schindewolf worked during his internship at the Lawrence Livermore National Laboratory (LLNL) under the guidance of Martin Schulz at the Computer Science Group of the Center for Applied Scientific Computing. We studied the performance of the TM subsystem of BG/Q as well as researched the possibilities for tool support for TM. To study the performance, we run CLOMP-TM. CLOMP-TM is a benchmark designed for the purpose to quantify the overhead of OpenMP and compare different synchronization primitives. To advance CLOMP-TM, we added Message Passing Interface (MPI) routines for a hybrid parallelization. This enables to run multiple MPI tasks, each running OpenMP, on one node. With these enhancements, a beneficial MPI task to OpenMP thread ratio is determined. Further, the synchronization primitives are ranked as a function of the application characteristics. To demonstrate the usefulness of these results, we investigate a real Monte Carlo simulation called Monte Carlo Benchmark (MCB). Applying the lessons learned yields the best task to thread ratio. Further, we were able to tune the synchronization by transactifying the MCB. Further, we develop tools that capture the performance of the TM run time system and present it to the application's developer. The performance of the TM run time system relies on the built-in statistics. These tools use the Blue Gene Performance Monitoring (BGPM) interface to correlate the statistics from the TM run time system with performance counter values. This combination provides detailed insights in the run time behavior of the application and enables to track down the cause of degraded performance. Further, one tool has been implemented that separates the performance counters in three categories: Successful Speculation, Unsuccessful Speculation and No Speculation . All of the tools are crafted around IBM's xlc compiler for C and C++ and have been run and tested on a Q32 early access system.

97 MATHEMATICS AND COMPUTING↗

An Overview of the Earth Observing System Moderate Resolution Imaging Spectroradiometer (MODIS) Data Products and Availability for Environmental Applications and Global Change Studies

The Moderate Resolution Imaging Spectroradiometer (MODIS) on the Earth Observing System (EOS) Terra Mission began to produce data in February 2000. The Terra MODIS is in a sun-synchronous orbit going north to south in the daylight portion of the orbit crossing the equator at about 1030 hours local time. The spacecraft, instrument, and data systems are performing well and are producing a wide variety of data products useful for scientific and applications studies in relatively consistent fashion extending from November 2000 to the present. Within the approximately 40 MODIS data products, several are new and represent powerful and exciting capabilities such the ability to provide observations over the globe of fire occurrences, microphysical properties of clouds and sun-stimulated fluorescence from phytoplankton in the surface waters of the ocean. The remainder of the MODIS products exceeds or, at a minimum, matches the capabilities of products from heritage sensors such as, for example, the Advanced Very High Resolution Radiometer (AVHRR). Efforts are underway to provide data sets for the greater Earth science community and to improve access to these products at the various Distributed Active Archive Centers (DAACs) or through Direct Broadcast (DB) stations. The EOS Aqua mission was launched successfully May 4,2002 with another MODIS on it. The Aqua spacecraft operates in a sun-synchronous orbit going south to north in the daylight portion of the orbit crossing the equator at approximately 1330 hours local time. Subsequently the Aqua MODIS observations will substantially add to the capabilities of the Terra MODIS for environmental applications and global change studies.

Salomonson, V. V.↗

An Overview of the Earth Observing System Moderate Resolution Imaging Spectroradiometer (MODIS) Data Products Status and Availability for Environmental Applications and Global Change Studies

The Moderate Resolution Imaging Spectroradiometer (MODIS) on the Earth Observing System (EOS) Terra Mission began to produce data in February 2000. The Terra MODIS is in a sun-synchronous orbit going north to south in the daylight portion of the orbit crossing the equator at about 1030 hours local time. The spacecraft, instrument, and data systems are performing well and are producing a wide variety of data products useful for scientific and applications studies in relatively consistent fashion extending from November 2000 to the present. Within the approximately 40 MODIS data products, several are new and represent powerful and exciting capabilities such the ability to provide observations over the globe of fire occurrences, microphysical properties of clouds and sun-stimulated fluorescence from phytoplankton in the surface waters of the ocean. The remainder of the MODIS products exceed or, at a minimum, match the capabilities of products from heritage sensors such as, for example, the Advanced Very High Resolution Radiometer (AVHRR). Efforts are underway to provide data sets for the greater Earth science community and to improve access to these products at the various Distributed Active Archive Centers (DAAC's) or through Direct Broadcast (DB) stations. The MODIS instrument on the EOS Aqua mission should also be expected to be in orbit and functioning in the Spring of 2002. The Aqua spacecraft will operate in a sun-synchronous orbit going south to north in the daylight portion of the orbit crossing the equator at approximately 1330 hours local time. Subsequently the Aqua MODIS observations will substantially add to the capabilities of the Terra MODIS for environmental applications and global change studies.

Salomonson, Vincent V.↗

Control and Simulation of a Grid-Forming Inverter for Hybrid PV-Battery Plants in Power System Black Start

Power system restoration is an important part of system planning. Power utilities are required to maintain black start capable generators that can energize the transmission system and provide cranking power to non-blackstart capable generators. Traditionally, hydro and diesel units are used as black start capable generators. With the increased penetration of bulk size solar farms, inverter based generation can play an important role in faster and parallel black start thus ensuring system can be brought back into service without the conventional delays that can be expected with limited black start generators. Inverter-based photovoltaic (PV) power plants have advantages that are suitable for black start. This paper proposes the modeling, control, and simulation of a grid-forming inverter-based PV-battery power plant that can be used as a black start unit. The inverter control includes both primary and secondary control loops to imitate the control of a conventional synchronous machine. The proposed approach is verified using a test system modified from the IEEE 9-bus system in the time-domain electromagnetic transient simulation tool PSCAD. The simulation results shows voltage and frequency stability during a multi-step black-start and network energization process.

Nguyen, Quan H.↗

Cherenkov Video Imaging Allows for the First Visualization of Radiation Therapy in Real Time

Purpose: To determine whether Cherenkov light imaging can visualize radiation therapy in real time during breast radiation therapy. Methods and Materials: An intensified charge-coupled device (CCD) camera was synchronized to the 3.25-μs radiation pulses of the clinical linear accelerator with the intensifier set × 100. Cherenkov images were acquired continuously (2.8 frames/s) during fractionated whole breast irradiation with each frame an accumulation of 100 radiation pulses (approximately 5 monitor units). Results: The first patient images ever created are used to illustrate that Cherenkov emission can be visualized as a video during conditions typical for breast radiation therapy, even with complex treatment plans, mixed energies, and modulated treatment fields. Images were generated correlating to the superficial dose received by the patient and potentially the location of the resulting skin reactions. Major blood vessels are visible in the image, providing the potential to use these as biological landmarks for improved geometric accuracy. The potential for this system to detect radiation therapy misadministrations, which can result from hardware malfunction or patient positioning setup errors during individual fractions, is shown. Conclusions: Cherenkoscopy is a unique method for visualizing surface dose resulting in real-time quality control. We propose that this system could detect radiation therapy errors in everyday clinical practice at a time when these errors can be corrected to result in improved safety and quality of radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗