Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerating cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

RF CONTROL OF HIGH QL SUPERCONDUCTING CAVITIES

In the last 20 years the requirements for RF Control have increased as the target use has broadened from electron/ion accelerators for Nuclear and Particle Physics to light sources such as Free Electron Lasers. The increasing requirement of cavity field control to meet the spectral and jitter performance specifications for light sources has led system designers to a more rigorous approach in designing the RF controls. Design attention must be applied not only to the hardware and control algorithms but also to the overall accelerating system to meet performance and cost requirements. As an example, cavity QL in Energy Recovery Linacs (ERL) must be optimized such that the RF controls can accommodate the lowest possible RF power given the background cavity microphonics. This paper presents the status and future directions of high QL superconducting RF control systems.

Hovater, James↗

Comparison of G4beamline and ICOOL Simulations of a Neutrino Factory/Muon Collider Front End and Simplification in RF Structure Requirements

Earlier studies on the front end of a neutrino factory or muon collider have relied on a single simulation tool, ICOOL. We present here a cross-check against another simulation tool, G4beamline. We also perform a study to simplify the RF structure requirements by reducing the number of RF cavity frequencies and gradients. This investigation is also pertinent to engineering tolerances expected of these structures. We conclude with a discussion of future studies.

43 PARTICLE ACCELERATORS↗

Observation of quenching-induced magnetic flux trapping using a magnetic field and temperature mapping system

Highly efficient superconducting radio-frequency cavities exhibit low heat loss and are used as components in accelerators and superconducting devices due to their high Q-values. The precise location of magnetic flux trapping in cavities is necessary to identify its effects on the performance of superconducting cavities. In this study, we report a new combined mapping system to measure the temperature and magnetic field on the equator. The proposed system comprehensively maps local magnetic field changes as magnetic flux trapping due to quenching. Our experimental results show that magnetic flux trapping due to quenching increases the local surface resistance of superconducting cavities at 2 K. Thus, the proposed system elucidates the relationship between local flux trapping due to quenching and surface resistance in superconducting cavities and highlights the effect of quenching on the surface resistance. This system can aid in the development of superconducting cavities with higher Q values.

43 PARTICLE ACCELERATORS↗

Numerical study of a bucked-coil system for muon transport and cooling

A Neutrino Factory, which can deliver an intense flux of {approx}10{sup 21} neutrinos per year from a multi-GeV stored muon-beam is seemingly the ideal tool for studying neutrino oscillations and CP-violations for leptons. The front-end of this facility plays a critical role in determining the number of muons that can be accepted by the downstream accelerators. Delivering peak performance requires transporting the muon beams through long sections of a beam channel containing high-gradient rf cavities and strong focusing solenoids. Here, we propose a novel scheme to improve the performance of the cavities, thereby increasing the number of muons within the acceptance of the accelerator chain. The key element of our new scheme is to apply a set of bucked coils along the lattice, thus forcing the external magnetic field to drop substantially within the cavity. We incorporate this idea into a new lattice design for a Neutrino Factory, and detail its performance numerically.

43 PARTICLE ACCELERATORS↗

RF Breakdown Studies Using a 1.3 GHZ Test Cell

Many present and future particle accelerators are limited by the maximum electric gradient and peak surface fields that can be realized in RF cavities. Despite considerable effort, a comprehensive theory of RF breakdown has not been achieved and mitigation techniques to improve practical maximum accelerating gradients have had only limited success. Recent studies have shown that high gradients can be achieved quickly in 805 MHz RF cavities pressurized with dense hydrogen gas without the need for long conditioning times, because the dense gas can dramatically reduce dark currents and multipacting. In this project we use this high pressure technique to suppress effects of residual vacuum and geometry found in evacuated cavities to isolate and study the role of the metallic surfaces in RF cavity breakdown as a function of magnetic field, frequency, and surface preparation. A 1.3-GHz RF test cell with replaceable electrodes (e.g. Mo, Cu, Be, W, and Nb) and pressure barrier capable of operating both at high pressure and in vacuum has been designed and built, and preliminary testing has been completed. A series of detailed experiments is planned at the Argonne Wakefield Accelerator. At the same time, computer simulations of the RF Breakdown process will be carried out to help develop a consistent physics model of RF Breakdown. In order to study the effect of the radiofrequency on RF Breakdown, a second test cell will be designed, fabricated, and tested at a lower frequency, most likely 402.5 MHz.

43 PARTICLE ACCELERATORS↗

Study of effects of failure of beamline elements and their compensation in CW superconducting linac

Project-X is the proposed high intensity proton facility to be built at Fermilab, US. First stage of the Project-X consists of superconducting linac which will be operated in continuous wave (CW) mode to accelerate the beam from 2.5 MeV to 3 GeV. The operation at CW mode puts high tolerances on the beam line components, particularly on radiofrequency (RF) cavity. The failure of beam line elements at low energy is very critical as it results in mis-match of the beam with the following sections due to different beam parameters than designed parameter. It makes the beam unstable which causes emittance dilution, and ultimately results in beam losses. In worst case, it could affect the reliability of the machine and may lead to the shutdown of the Linac to replace the failed elements. Thus, it is important to study these effects and their compensation to get smooth beam propagation in linac. This paper describes the results of study performed for the failure of RF cavity & solenoid in SSR0 section.

43 PARTICLE ACCELERATORS↗

HIGH Q0 AT MEDIUM FIELDS IN Nb3Sn SRF CAVITIES AT 4.2 K

Nb3Sn has proven itself to be a very promising alternative SRF material. With twice the critical temperature of niobium cavities, 1.3 GHz Nb3Sn cavities can achieve quality factors on the order of 1010 even at 4.2 K, significantly reducing cryogenic infrastructure and operational costs. In addition, its large predicted superheating field may allow for maximum accelerating gradients up to twice that of niobium for high energy applications. In this work, we report on new cavity results fromthe CornellNb3Sn SRF program demonstrating a significant improvement in the maximum field achieved with high Q0 in a Nb3Sn cavity. At 4.2 K, accelerating gradients above 16MV/m were obtainedwith Q0 of 8 × 109, showing the potential of this material for future applications. In addition to this result, current limitations are discussed.

Nb3Sn↗

Commissioning of a two-target DC cylindrical magnetron sputter coater for depositing Nb 3 Sn film on Nb superconducting radiofrequency cavities

A DC cylindrical magnetron sputter coater was commissioned and used to coat Nb 2.6 GHz superconducting radiofrequency (SRF) cavity with Nb 3 Sn. The sputter coater has two identical cylindrical magnetrons that can move, with a controlled speed, along the axis of the SRF cavity to coat the inside surface of the cavity. The design of the sputter coater is discussed, along with its performance. Initially, a sample holder that allows coating on flat substrates at positions similar to the equator and beam tubes of a 2.6 GHz SRF cavity was used to test conditions for fabricating Nb 3 Sn layers. Multilayers of Nb and Sn were sequentially sputtered on flat Nb and sapphire substrates mounted on the equivalent positions of the cavity's beam tubes and the equator using the two identical cylindrical magnetrons. Then, the Nb/Sn multilayers were annealed at 950 °C for 3 h. Here, the ~1.2 μm thick Nb 3 Sn film did not show any other Nb–Sn compounds and had a superconducting transition temperature of 17.61–17.76 K. The 2.6 GHz SRF cavity was coated using similar conditions as flat samples. Cryogenic RF testing of the Nb 3 Sn-coated cavity demonstrated a quality factor of 3.2 × 10 8 at an accelerating gradient of 5 MV/m at 4.4 K.

43 PARTICLE ACCELERATORS↗

Determination of bulk and surface superconducting properties of N 2 -doped cold worked, heat treated and electro-polished SRF grade niobium

In this study, nitrogen-doped cavities show significant performance improvement in the medium accelerating field regime due to a lowered RF surface resistivity. However, the mechanism of enhancement has not been clearly explained. Our experiments explore how N 2 -doping influences Nb bulk and surface superconducting properties, and compare the N 2 -doped properties with those obtained previously with conventionally treated samples. High purity Nb-rod was mechanically deformed and post treated based on a typical SRF cavity treatment recipe. The onset of flux penetration at H c1 , and the upper and the surface critical fields, H c2 and H c3 , were characterized by magnetic hysteresis and AC susceptibility techniques. The surface depth profile responsible for superconductivity was examined by changing AC amplitude in AC susceptibility, and the microstructure was directly observed with EBSD-OIM. We are also investigating surface chemistry for detailed composition using XPS. We have found that N 2 -doping at 800 °C significantly reduces the H c3 /H c2 ratio towards the ideal value of ~1.7, and conclude that AC susceptibility is capable of following changes to the surface properties induced by N 2 -doping.

36 MATERIALS SCIENCE↗

Preliminary Results from Multi-cell seamless niobium cavities fabricated by hydroforming

The technology of forming multi-cell seamless niobium cavities has been developed at DESY within the European CARE (Coordinated Accelerator Research in Europe) program. Three-cell units have been manufactured successfully and a 9-cell cavity has recently been completed from three sub-sections and has been successfully tested at DESY. Additionally, we have equipped two 3-cell units ? one center unit of a 9-cell cavity and one end-unit ? with niobium beam pipes, have tuned these units and carried out cryogenic radio-frequency (RF) tests after standard BCP surface treatments had been applied to these cavities. In addition, we have taken temperature maps with JLab?s two-cell thermometry system to compare with standard electron-beam welded cavities. This contribution will report about the preliminary cryogenic test results and the T-mapping ? this is an ongoing investigation.

Singer, X.↗

Design of coupler for the NSLS-II storage ring superconducting RF cavity

NSLS-II is a 3GeV, 500mA, high brightness, 1 MW beam power synchrotron facility that is designed with four superconducting cavities working at 499.68 MHz. To operate the cavities in over-damped coupling condition, an External Quality Factor (Qext) of {approx}65000 is required. We have modified the existing coupler for the CESR-B cavity which has a Qext of {approx}200,000 to meet the requirements of NSLS-II. CESR-B cavity has an aperture coupler with a coupler 'tongue' connecting the cavity to the waveguide. We have optimized the length, width and thickness of the 'tongue' as well as the width of the aperture to increase the coupling using the three dimensional electromagnetic field solver, HFSS. Several possible designs will be presented. We have modified the coupler of the CESR-B cavity to be used in the storage ring at the NSLS-II project using HFSS and verified using CST Microwave Studio. Using a combination of increasing the length and width of the coupler tongue and increasing the width of the aperture, the external Q of the cavity coupler was decreased to {approx}65000 as required for the design of the NSLS-II storage ring design.

3GeV↗

Field, frequency, and temperature dependencies of the surface resistance of nitrogen diffused niobium superconducting radio frequency cavities

We investigate the rf performance of several single-cell superconducting radio-frequency cavities subjected to low temperature heat treatment in nitrogen environment. The cavities were treated at temperature 120 – 165 ° C for an extended period of time (24–48 h) either in high vacuum or in a low partial pressure of ultrapure nitrogen. The improvement in Q 0 with a Q rise was observed when nitrogen gas was injected at ∼ 300 ° C during the cavity cooldown from 800 ° C and held at 165 ° C , without any degradation in accelerating gradient over the baseline performance. The treatment was applied to several elliptical cavities with frequency ranging from 0.75 to 3.0 GHz, showing an improved quality factor as a result of low temperature nitrogen treatments. The Q rise feature is similar to that achieved by nitrogen alloying Nb cavities at higher temperature, followed by material removal by electropolishing. The surface modification was confirmed by the change in electronic mean free path and tuned with the temperature and duration of heat treatment. The decrease of the temperature-dependent surface resistance with increasing rf field, resulting in a Q rise, becomes stronger with increasing frequency and decreasing temperature. The data suggest a crossover frequency of ∼ 0.95 GHz above that the Q rise phenomenon occurs at 2 K. Some of these results can be explained qualitatively with an existing model of intrinsic field-dependence of the surface resistance with both equilibrium and nonequilibrium quasiparticle distribution functions. The change in the Q slope below 0.95 GHz may result from masking contribution of trapped magnetic flux to the residual surface resistance. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

RF Breakdown Studies Using a 1.3-GHz Text Cell

Many present and future particle accelerators are limited by the maximum electric gradient and peak surface fields that can be realized in RF cavities. Despite considerable effort, a comprehensive theory of RF breakdown has not been achieved and mitigation techniques to improve practical maximum accelerating gradients have had only limited success. Recent studies have shown that high gradients can be achieved quickly in 805 MHz RF cavities pressurized with dense hydrogen gas without the need for long conditioning times, because the dense gas can dramatically reduce dark currents and multipacting. In this project we use this high pressure technique to suppress effects of residual vacuum and geometry found in evacuated cavities to isolate and study the role of the metallic surfaces in RF cavity breakdown as a function of magnetic field, frequency, and surface preparation. A 1.3-GHz RF test cell with replaceable electrodes (e.g. Mo, Cu, Be, W, and Nb) and pressure barrier capable of operating both at high pressure and in vacuum has been designed and built, and preliminary testing has been completed. A series of detailed experiments is planned at the Argonne Wakefield Accelerator. At the same time, computer simulations of the RF Breakdown process will be carried out to help develop a consistent physics model of RF Breakdown. In order to study the effect of the radiofrequency on RF Breakdown, a second test cell will be designed, fabricated, and tested at a lower frequency, most likely 402.5 MHz.

43 PARTICLE ACCELERATORS↗

Direct observation of dislocation structure evolution in SRF cavity niobium using electron channeling contrast imaging

Two major goals of superconducting radio frequency cavity research and development are achieving higher accelerating gradient and gaining the highest quality factor, a measure of efficiency. However, the consistent improvement of these performance metrics is restricted by many factors, one of which is microstructural defects, such as dislocation substructures within the material. In this work, dislocation evolution is compared in four samples extracted from a 2.8 mm thick large-grain niobium slice, with tensile axes chosen to generate specific dislocation structures during subsequent deformation. The four samples are (1) as-extracted, (2) extracted and annealed, (3) extracted and then deformed to 40% tensile strain, and (4) extracted, annealed at 800 °C 2 h, and then deformed to 40% strain. Electron channeling contrast imaging was performed on all samples to characterize initial dislocation density and dislocation structure evolution due to annealing and deformation, and related to the mechanical behavior observed in stress-strain curves. A fundamental understanding of dislocation evolution in niobium is necessary to develop computational models to simulate cavity forming, which could enable new processing methods for cavity fabrication to be identified that could lead to improved performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A 3-cell deflecting rf cavity for emittance exchange experiment at ANL.

An RF deflecting structure has been designed and fabricated for a transverse-to-longitudinal emittance exchange experiment at Argonne National Laboratory (ANL) [Y.-E. Sun, et al., Design study of a transverse-to-longitudinal emittance exchange proof-of-principle experiment, in: Proceedings of PAC-2007, Albuquerque, NM, USA, 2007, pp. 3441-3443]. The structure is a 1300 MHz normal conducting RF cavity consisting of three cells operating in a dipole (TM{sub 110}-like) mode. As high as 3.4 MV deflecting voltage is required for the experiment. In this paper, we present detailed RF design of the cavity, particle tracking simulations in the cavity and low power RF measurement results in comparison with numerical simulations. The cavity cell geometries (gaps in particular) are optimized to giving a zero orbit offset for particles crossing the cavity with zero-phase.

43 PARTICLE ACCELERATORS↗

Investigation of Accelerated Partial Breast Patient Alignment and Treatment With Helical Tomotherapy Unit

Purpose: To determine the precision of megavoltage computed tomography (MVCT)-based alignment of the seroma cavity for patients undergoing partial breast irradiation; and to determine whether accelerated partial breast irradiation (APBI) plans can be generated for TomoTherapy deliveries that meet the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 protocol guidelines for target coverage and normal tissue dose limitations. Methods and Materials: We obtained 50 MVCT images from 10 patients. An interuser study was designed to assess the alignment precision. Using a standard helical and a fixed beam prototype ('topotherapy') optimizer, two APBI plans for each patient were developed. Results: The precision of the MVCT-based seroma cavity alignment was better than 2 mm if averaged over the patient population. Both treatment techniques could be used to generate acceptable APBI plans for patients that fulfilled the recommended NSABP B-39/RTOG-0413 selection criteria. For plans of comparable treatment time, the conformation of the prescription dose to the target was greater for helical deliveries, while the ipsilateral lung dose was significantly reduced for the topotherapy plans. Conclusions: The inherent volumetric imaging capabilities of a TomoTherapy Hi-Art unit allow for alignment of patients undergoing partial breast irradiation that is determined from the visibility of the seroma cavity on the MVCT image. The precision of the MVCT-based alignment was better than 2 mm ({+-} standard deviation) when averaged over the patient population. Using the NSABP B-39/RTOG-0413 guidelines, acceptable APBI treatment plans can be generated using helical- or topotherapy-based delivery techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep-learning-based domain adaptation for cavity fault prediction at Jefferson Laboratory

Superconducting radio-frequency (SRF) cavities are the core components of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab, providing high-power electron beams for nuclear physics experiments. The facility comprises 418 SRF cavities, and any fault in these cavities can lead to interruptions in the electron beam supply. Cavity faults are the leading cause of beam trips in CEBAF. Predicting and mitigating those faults before onset can help maintain normal operation. Existing models face challenges in distinguishing between normal and fault signals when changes occur in the underlying time-series data, from changes in control software, operational parameters, or the environment. This work proposes a deep learning domain adaptation model that leverages transfer learning to address fault prediction challenges by improving accuracy. The model is trained and fine-tuned using a dataset collected for faulty and normal operation using a data acquisition system in CEBAF. Our deep learning-based domain adaptation model achieves a prediction accuracy of 89.61% of the fault and normal signals. The developed model effectively predicts normal running signals compared to the baseline approach without domain adaptation. This capacity is essential for the fault prediction task in the CEBAF because of heavily imbalanced data containing vast amounts of normal signals. The model performs well for predicting faults several hundred milliseconds before the fault onset compared to other models where no adaptation is applied. Incorporating deep learning-based domain adaptation techniques will significantly improve the fault prediction performance.

Rahman, Md Monibor [Old Dominion Univ., Norfolk, V↗

Materials Science of the Interstitial Doping Process

Particle accelerators are an increasingly important tool for frontier science. Growing initial and operating costs are a significant barrier for upgrades and for new machines. While everything matters, the major cost contributor is the SRF cavities and their ancillary facilities (e.g., cryoplant). Accordingly, the accelerator science community devotes much R&D effort to improving their energy efficiency (increased Q o ) and gradient (E acc ). While improved gradient is at the forefront for certain machines (ILC), improved quality factor has broader impact, benefitting all SRF applications. An important opportunity for accelerator science and technology to move forward arose in the course of building the LCLS-II, the second generation Linac Coherent Light Source at SLAC. At more or less the same time, researchers at Fermilab discovered that introducing a small amount of nitrogen to the niobium surface could improve the mid-range quality factor as much as three-fold. A firm resolution of how nitrogen confers its benefit attracts much current research interest. The key elements of the “nitrogen doping” process were vacuum bake at 800 °C, brief exposure to mTorr of nitrogen at several hundred degrees followed by electropolish (EP) to remove several microns from the surface to eliminate unwanted nitrides: While the process as a whole was novel, the comprising unit operations are familiar to the accelerator community. It was judged reasonable to adopt it as a cost-reduction technology for LCLS-II. Researchers carried out a program of varying process parameters and measuring performance in single-cell cavities, leading to a consensus stable protocol for the project. The transition to vendor fabrication and multiple niobium sources has presented unforeseen challenges of performance variation evidently not connected to anything that could be incorporated in a purchase specification. Moving beyond the high temperature N-doping process above, researchers reported a simplified process consisting entirely of tens of hours anneal in a N atmosphere at low temperatures (~120°C – 160°C) after 800 °C UHV bake. These processes typically yield a few-nm doped layer while the high temperature process yields at least a few to many micron doped layer. Even more recently, oxygen has been used to dope instead of nitrogen which leaves a few-µm O-alloyed layer upon vacuum annealing for 300 °C for ~3 hours. The investigation of these materials is just beginning, but the process simplification they may offer is surely attractive. The very low quantity of material that appears to be significant in the “infusion” process indicates the need for very careful control of gas species available for diffusion into the surface during low temperature treatment, both for process control and research to characterize the underlying dynamics. Oxygen alloying offers the further opportunity to utilize the decomposition of the surface native oxide as the dopant source. It is necessary to understand and (thus) manage this process. We have been supported by the Department of Energy Offices of High Energy Physics and Nuclear Physics to pursue this goal.

36 MATERIALS SCIENCE↗