Search NASA⌕ Search

SEARCH · Search NASA

Results for “Adding Nuclear”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Beirut Explosion Yield and Mushroom Cloud Height - Effects of the Source Environment

I use crater dimensions to estimate the yield of the August 4th, 2020 Beirut explosion to be equivalent to approximately 1.4 kilotons of TNT with a lower bound of about 0.7 kilotons. Based on the amount of ammonium nitrate reported to have been stored at the Beirut harbor, I assume an upper bound for the yield of 2.75 kilotons. However, it is highly likely that the yield was less than 2.75 kilotons, since reported values for TNT equivalence of ammonium nitrate are typically much less than one hundred percent. The crater-size based yield estimates are based on crater radius estimates from satellite imagery and empirical curves and data for scaled crater radius from past chemical and nuclear explosions. I present evidence that suggests that the relatively large crater radius is due to a high degree of coupling of shock wave energy to the surrounding medium and a reduction of the effective stress because of a high level of saturation of the geologic media beneath the explosion. I provide yield estimates based on seismic body-wave magnitude and crater depth as corroborating evidence. I compare preliminary estimates for the maximum debris cloud height, based on cell phone videos/images, with predicted maximum heights for this yield range from empirical formulas and numerical cloud-rise models. Based on a preliminary analysis of cell phone footage, the observed maximum cloud height appears to be approximately 1600 m. This is much lower than that predicted using standard empirical formulas and buoyant cloud rise models. I present results from a modified buoyant cloud rise model that more accurately predicts the maximum cloud height by allowing for the inclusion of a fixed amount of air and/or water into the fireball at the start of cloud rise. The amount of mass that needs to be added at the start, to reproduce the observed maximum cloud height, is relatively small compared to the total mass entrained during cloud rise. A much greater amount of dry air or debris is required, relative to water, for an equivalent reduction in maximum cloud height. The ammonium nitrate is one possible source for water in the fireball since it was being stored in a very humid environment and ammonium nitrate is known to be hygroscopic. The ground beneath the explosion, especially if it were saturated, and the nearby harbor could also have been sources for water or debris in the fireball.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

NuSTAR Observations of Abell 2163: Constraints on Non-thermal Emission

Since the first non-thermal reports of inverse Compton (IC) emission from the intracluster medium (ICM) of galaxy clusters at hard X-ray energies, we have yet to unambiguously confirm IC emission in observations with newer facilities. RXTE detected IC emission in one of the hottest known clusters, Abell 2163 (A2163), a massive merging cluster with a giant radio halo—the presumed source of relativistic electrons IC scattering CMB photons to X-ray energies. The cluster's redshift (z ~ 0.2) allows its thermal and non-thermal radio emission to fit the field of view of the Nuclear Spectroscopic Telescope Array (NuSTAR), permitting a deep observation capable of confirming or ruling out the RXTE report. The IC flux provides constraints on the average magnetic field strength in a cluster. To determine the global diffuse IC emission in A2163, we fit its global NuSTAR spectrum with four models: single- (1T) and two-temperature (2T), 1T+power-law component (T+IC), and multi-temperature+power law (9T+IC). Each represents different characterizations of the thermal ICM emission, with power-law components added to represent IC emission. We find that the 3–30 keV spectrum can be described by purely thermal emission, with a global average temperature of kT = (11.8 ± 0.2) keV. The IC flux is constrained to <4.0 × 10 –12 erg s –1 cm –2 using the 1T+IC model and <1.6 × 10 –12 erg s –1 cm –2 with the more physical 9T+IC model, both to 90% confidence levels. Here, combining these limits with 1.4 GHz diffuse radio data from the VLA, we find the average magnetic field strength to be >0.22 μG and >0.35 μG, respectively, providing the strongest constraints on these values in A2163 to date.

79 ASTRONOMY AND ASTROPHYSICS↗

DECOVALEX-2015: an international collaboration for advancing the understanding and modeling of coupled thermo-hydro-mechanical-chemical (THMC) processes in geological systems

Here, an important part of the performance and safety assessment of disposal systems for radioactive waste and spent nuclear fuel in deep geological formations is to evaluate the impact of the coupled effects of mechanical deformation, fluid and gas flow through the repository, and thermal loading from the decaying waste. It was recognized early on in safety and performance assessments conducted for geologic disposal sites that to be able to conduct such an evaluation, there was a need to rigorously enhance the theoretical background and to develop models capable of simulating coupled thermo-hydro-mechanical (THM) processes. More recently, chemical processes have also been added to enable the study of fully coupled THMC processes in geosystems.

58 GEOSCIENCES↗

Megavoltage Cone Beam Computed Tomography Dose and the Necessity of Reoptimization for Imaging Dose-Integrated Intensity-Modulated Radiotherapy for Prostate Cancer

Purpose: Megavoltage cone beam computed tomography (MV-CBCT) dose can be integrated with the patient's prescription. Here, we investigated the effects of imaging dose and the necessity for additional optimization when using intensity-modulated radiotherapy (IMRT) to treat prostate cancer. Methods and Materials: An arc beam mimicking MV-CBCT was generated using XiO (version 4.50; Elekta, Stockholm, Sweden). The monitor units (MU) for dose calculation were determined by conforming the calculated dose to the dose measured using an ionization chamber. IMRT treatment plans of 22 patients with prostate cancer were retrospectively analyzed. Arc beams of 3, 5, 8, and 15 MU were added to the IMRT plans, and the dose covering 95% of the planning target volume (PTV) was normalized to the prescribed dose with (reoptimization) or without optimization (compensation). Results: PTV homogeneity and conformality changed negligibly with MV-CBCT integration. For critical organs, an imaging dose-dependent increase was observed for the mean rectal/bladder dose (D{sub mean}), and reoptimization effectively suppressed the D{sub mean} elevations. The bladder generalized equivalent uniform dose (gEUD) increased with imaging dose, and reoptimization suppressed the gEUD elevation when 5- to 15-MU CBCT were added, although rectal gEUD changed negligibly with any imaging dose. Whereas the dose elevation from the simple addition of the imaging dose uniformly increased rectal and bladder dose, the rectal D{sub mean} increase of compensation plans was due mainly to low-dose volumes. In contrast, bladder high-dose volumes were increased by integrating the CBCT dose, and reoptimization reduced them when 5- to 15-MU CBCT were added. Conclusion: Reoptimization is clearly beneficial for reducing dose to critical organs, elevated by addition of high-MU CBCT, especially for the bladder. For low-MU CBCT aimed at bony structure visualization, compensation is sufficient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Under conditions of large geometric miss, tumor control probability can be higher for static gantry intensity-modulated radiation therapy compared to volume-modulated arc therapy for prostate cancer

The purpose of this work was to compare static gantry intensity-modulated radiation therapy (IMRT) with volume-modulated arc therapy (VMAT) in terms of tumor control probability (TCP) under scenarios involving large geometric misses, i.e., those beyond what are accounted for when margin expansion is determined. Using a planning approach typical for these treatments, a linear-quadratic–based model for TCP was used to compare mean TCP values for a population of patients who experiences a geometric miss (i.e., systematic and random shifts of the clinical target volume within the planning target dose distribution). A Monte Carlo approach was used to account for the different biological sensitivities of a population of patients. Interestingly, for errors consisting of coplanar systematic target volume offsets and three-dimensional random offsets, static gantry IMRT appears to offer an advantage over VMAT in that larger shift errors are tolerated for the same mean TCP. For example, under the conditions simulated, erroneous systematic shifts of 15 mm directly between or directly into static gantry IMRT fields result in mean TCP values between 96% and 98%, whereas the same errors on VMAT plans result in mean TCP values between 45% and 74%. Random geometric shifts of the target volume were characterized using normal distributions in each Cartesian dimension. When the standard deviations were doubled from those values assumed in the derivation of the treatment margins, our model showed a 7% drop in mean TCP for the static gantry IMRT plans but a 20% drop in TCP for the VMAT plans. Although adding a margin for error to a clinical target volume is perhaps the best approach to account for expected geometric misses, this work suggests that static gantry IMRT may offer a treatment that is more tolerant to geometric miss errors than VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cyberknife stereotactic radiosurgery and radiation therapy treatment planning system

CyberKnife is an image-guided stereotactical dose delivery system designed for both focal irradiation and radiation therapy (SRT). Focal irradiation refers the use of many small beams to deliver highly focus dose to a small target region in a few fractions. The system consists of a 6-MV linac mounted to a robotic arm, coupled with a digital x-ray imaging system. The radiation dose is delivered using many beams oriented at a number of defined or nodal positions around the patients. The CyberKnife can be used for both intracranial and extracranial treaments unlike the Gamma Knife which is limited to intracranial cases. Multiplan (Accuray Inc., Sunnyvale, CA) is the treatment planning system developed to cooperate with this accurate and versatile SRS and SRT system, and exploit the full function of Cyberknife in high-precision radiosurgery and therapy. Optimized inverse treatment plan can be achieved by fine-tuning contours and planning parameters. Precision is the newest version of Cyberknife treatment planning system (TPS) and an upgrade to Multiplan. It offers several new features such as Monte Carlo for multileaf collimator (MLC) and retreatment for other modalities that added more support for the Cyberknife system. The Cybeknife TPS is an easy-to-use and versatile inverse planning platform, suitable for stereotactic radiosurgery and radiation therapy. The knowledge and experience of the planner in this TPS is essential to improve the quality of patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toluene nitration in irradiated nitric acid and nitrite solution

The kinetics, mechanisms, and stable products produced for the aryl alkyl mild ortho-para director - toluene, in irradiated nitric acid and neutral nitrite solutions were investigated using ?, and pulse radiolysis. Electron pulse radiolysis was used to determine the bimolecular rate constants for the reaction of toluene with different transient species produced by irradiation. HPLC with UV detection was primarily used to assess the stable reaction products. GC-MS and LC-MS were used to confirm the results from HPLC. Free-radical nitration reaction products were found in irradiated acidic and neutral media. In acidic medium, the ring substitution and side chain substitution and oxidation produced different nitro products. In ring substitution, nitrogen oxide radicals were added mainly to hydroxyl radical-produced cyclohexadienyl radical, and in side chain substitution they were added to the carbon-centered benzyl radical produced by H-atom abstraction. In neutral nitrite toluene solution, radiolytic ring nitration products approached a statistically random distribution, suggesting a free-radical reaction involving addition of the •NO2 radical.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Investigating Ternary Li–Mg–Si Zintl Phase Formation and Evolution for Si Anodes in Li-Ion Batteries with Mg(TFSI) 2 Electrolyte Additive

Improved electrochemical performance of Si was recently reported by adding multivalent cation salts (such as Mg 2+ , Al 3+ , Ca 2+, etc.) in the electrolyte. This is achieved via the formation in an in situ manner of relatively more stable Li-M-Si ternary phases with less chemical reactivity. These phases stabilize Si anions and thus reduce side reactions with electrolytes at the surface and eventually benefit the overall electrochemistry. To understand the mechanism of ternary Zintl phase formation and its dynamics upon lithiation/delithiation, high-resolution solid-state 7 Li and 29 Si nuclear magnetic resonance (NMR) are utilized to directly probe the local Li and Si environments on Si electrodes harvested from coin and pouch cells at various states of (de)lithiation. The NMR spectra along with the electrochemical characterization reveal that lithiation of Si starts from the surface Si-O layer further confirmed by 7 Li– 29 Si cross-polarization NMR. Lithiation progresses with heterogeneous silicon clustering with Si -4 anions at high states of lithiation. At a fully lithiated state, the formation of overlithiated Si species is detected. At a low-voltage region (below 100 mV), direct evidence for Mg-ion insertion is found, postulated by two possible mechanisms: ion exchange with fully or overlithiated binary domains (Li 3.75+x Si) and/or a coinsertion with slightly underlithiated domains (similar to Li 3.55 Si). Upon delithiation, Li extraction starts from overlithiated Si domains. No evidence is found for electrochemical Mg removal. Evidence for a lithium-deficient Li y Mg 0.1 Si phase is found as a result of Li removal during charging. This investigation sheds light on the possible mechanisms of a new Si anode chemistry, which could enable the development of stable Si-based anodes for lithium-ion batteries.

25 ENERGY STORAGE↗

Core excitation contributions to the breakup of the one-neutron halo nucleus {sup 11}Be on a proton

The effect of the core excitation in the breakup of a one-neutron halo nucleus is studied within two different reaction formalisms, namely, the core excited model and the single-scattering approximation of the three-body Faddeev-Alt-Grassberger-Sandhas equations with target-core potential allowing for the core excitation. As an example, we consider the breakup of {sup 11}Be on a proton target at 63.7 MeV/nucleon incident energy and calculate the semi-inclusive cross section in the excitation energy interval E{sub x}=3.0-5.5 MeV (E{sub rel}=2.5-5 MeV) containing the 3/2{sup +} resonance with dominant contribution of the {sup 10}Be(2{sup +}) core excited state. The effect of the core excitation to the breakup cross section integrated around this resonance is found to be very significant. Moreover, when resonant and nonresonant contributions are added, the resulting semi-inclusive cross section is in reasonable agreement with the existing data, demonstrating the relevance of the core excitation mechanism for this observable. The present calculations also show the importance of incorporating the energy dependence of the core-target transition operators in the reaction formalism.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Update on the Benchmark Analysis of the Jupiter Experiments: Plutonium Moderated by Lead

The Jupiter experiment was a series of measurements in the summer of 2017 to analyze the effects of voids in lead moderated plutonium assemblies. This experiment was part of a larger campaign that took place at the National Criticality Experiments Research Center (NCERC) in collaboration with the Japan Atomic Energy Agency (JAEA) that also investigated assemblies with differing uranium enrichments. The purpose for this campaign was to provide data useful for a potential lead-bismuth cooled accelerator driven system. This data is needed due to the low number of benchmarks involving lead. Given the wide use of lead for shielding in addition to new reactor designs, there is a need for further benchmarking that this experiment could help fulfill. In addition, adding more benchmarks to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) is helpful for further validation of simulation methods used for criticality safety. This summary is an update on the current progress of this analysis, and all results shown are preliminary.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Supervisory Control System for Multi-Modular Advanced Reactors

The proposed supervisory control system (SCS) may provide considerable benefits to advanced small modular reactors, including reduced plant staffing, optimized maintenance activities, greater plant availability, and higher operating efficiency. The SCS makes risk-informed decisions based on (1) a probabilistic assessment of the likelihood of success given the status of the plant/systems and component health, and (2) a deterministic assessment between plant operating parameters and reactor protection parameters to prevent unnecessary trips and challenges to plant safety system—one measure of SCS success. The probabilistic portion of the decision-making engine of the SCS is based on the control actions associated with an advanced liquid-metal reactor (ALMR) Power Reactor, Innovative, Small Module (PRISM). Within the SCS, the probabilistic assessment provides a ranking of viable control actions; however, certain instructions generated by the probabilistic model only include an abstract notion of action without specifications. For instance, one instruction may be to reduce power without specifying how much reduction is needed. The prognostic/diagnostic models incorporate the health of components into the decision-making process. Once the control options are identified and ranked based on the likelihood of success, the SCS transmits the options to the deterministic portion of the platform. The performance-based system models assess and rank each of the probabilistically identified control actions by taking into account the physical behavior (current and projected) of the system. The performance-based decision making module receives inputs from the probabilistic decision-making module and the ERM module to generate a single solution. Interfaces to these modules are defined later in the section. A utility theory algorithm factors into the decision making by estimating the distance from and approach to a trip setpoint for each control option. If the magnitude of a negative utility value increases rapidly as the system approaches the trip setpoint, that option is not likely to be the preferred option. This can lead to a re-ranking of the control options. The SCS then transmits a control signal(s) to a component or system and informs the operator of actions taken based on the action chosen. The SCS successfully coupled probabilistic and performance-based system models to arrive at optimal control decisions based on the actual status of the plant and components. The automatic, autonomous, and real-time performance requirements for a control system were met by the SCS. The value of coupling probabilistic and performance-based system models was demonstrated by the re-ranking of control options based on the use of a utility algorithm. The use of ERM monitors provides added value to the SCS as demonstrated by the re-ranking of control options based on a components degraded state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Plans for Expanded Data Testing at ORNL [Slides]

VALID expansion is on-going and should provide coverage over a wider range of systems in the future. Adding additional application types beyond critical experiments can also be used in expanded data testing. Two other test suites have been developed at ORNL for other purposes, but never waste a good test suite. These suites are more likely to be relevant to testing differences in data as compared to assessing accuracy of evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diffusional creep in UO 2 informed by lower length scale simulations

Using molecular dynamics, we predict information at the atomistic scale used to develop a mechanistic UO 2 creep model for use in higher length-scale fuel performance codes. The ultimate objective of the model is to not only to capture the creep rates of UO 2 but to determine the dominant mechanism in the diffusional regime, which is still debated in the literature. It is important to have a model to capture the correct mechanisms for creep in UO 2 as this can be used as the foundation when applying to other fuels, such as doped UO 2 , and when irradiation is accounted. In last years NEAMS milestone (FY22), we developed a prelimnary model, however there were issues, for example, excessively high values of uranium vacancy concentrations at the grain boundary. This year we have addressed the issues with the previous version of the model, added a new term that accounts for the nucleation of dislocations at stress raisers (e.g., triple junctions) within the microstructure and discussed where there was disagreement in the literature about the underpinning physics (uranium self-diffusion at the grain boundary).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Multi-Layer Phoswich Radioxenon Detection System

Laboratory radioactive sources were used to characterize the phoswich detector. The CaF{sub 2} scintillator has a low light-yield and slow decay time, thus produces very small signals due to low-energy gamma rays or X-rays. Therefore, detection of 30 keV X-rays (from the xenon radioisotopes) using this layer and discriminating its very small signals from electronic noise was a challenging task. Several solutions were considered and experimentally evaluated. We found that the best solution would be extending the fast triangular filter from 10 taps to 30 taps. This will extend the peaking time of this filter from 25 nsec to 75 nsec. The digital filter is implemented in FPGA on our DPP2.0 and is used to trigger the detection system. Functionality of the new filter in capturing and discriminating 30 keV X-rays was confirmed by using a {sup 133}Ba gamma-ray source. Development of the DPP GUI software has continued with the addition of two new panels to display histograms of beta/gamma and beta/x-ray coincidence events. This includes coincidence events from a single channel, as well as two-channel, coincidence event. A pileup rejection algorithm has been implemented in the FPGA code, and controls to adjust its sensitivity have been added to the GUI. Work has begun on a new prototype system to develop a USB host interface between the PC and the FPGA to end reliance on Opal Kelly prototyping boards; the hardware for this system has been completely assembled, and the PC-side software is currently in development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Protection of Hardware: Powering Systems (Power Converter, Normal Conducting, and Superconducting Magnets)

Along with the protection of magnets and power converters, we have added a section on personnel protection because this is our highest priority in the design and operation of power systems. Thus, our topics are the protection of people, power converters, and magnet loads (protected from the powering equipment), including normal conducting magnets and superconducting magnets.

43 PARTICLE ACCELERATORS↗

Using Radiochromic Films to Characterize the Dispersion of ZrO{sub 2} Nano-sized Grain Clusters in Protective Polymer Composites

Radiation dosimetry is commonly used to prevent deterministic radiation effects in high dose medical procedures. Radiochromic films find nowadays widely application in radiotherapy, interventional procedures and CT exams for isodose and maximum skin dose measurements. Moreover the size of the irradiated area and its distribution can be performed through the reading of the individual components in the RGB-spectrum. Particularly, radiochromic film has multiple advantages over alternative dosimeters for low-kV X-rays dosimetry. Concerned to spatial resolution it is far superior to that of ionization chambers and thermoluminescent dosimeters. For high energy photon fields (keV to MeV) the most used radiochromic film commercially available belongs to the EBT Gafchromic{sup R} series. On the other hand, for low energy photon fields in the x-ray range (20 kVp to 200 kVp) the best choice belongs to the XR-QA Gafchromic{sup R} film series. In this work we demonstrate the possibility of generating 2D images of thin polymeric composites films using EBT3 and XR-QA2 Gafchromic{sup R} films exposed to 6 MeV and 40 keV x-ray photons, respectively, using the digital filtering tools of the ImageJ{sup R} free software. In this context, EBT3 films were placed on the surface of a rigid anthropomorphic phantom. Then, they were covered with a thermoplastic mask made of PCL polymer. This setup was then exposed to 2.0 Gy absorbed dose in the Linear Accelerator beam. The EBT3 films were then scanned in the high resolution mode in a commercial scanner and the images subsequently treated with digital filters. It is somehow possible to see the image of the thermoplastic mask in the scanned image. However, in the treated image it is easy to observe the mask arrangement. The unexpected phenomenon here is the EB3 film ability to detect the attenuation of high energy photons by a plastic material, which in turn has a very low mass-energy attenuation coefficient, producing a very clear 2D image. This result is discussed in terms of the high Z halides added to the sensitive layer of EB3 film, once the main components are C (42.3%), H (39.7%) and O (16.0%)1-2. Based on the above results, we have speculated about the abilities of XR-AQ films in the detection of the distribution of nano-sized particles that has high mass-energy attenuation coefficients for low energy x-rays, in polymer composites. In another investigation we tested the ability of XR-QA2 Gafchromic{sup R} films to evaluate the dispersion of ZrO{sub 2} nano-sized grain clusters in protective composites. The P(VDFTrFE)/ ZrO{sub 2} film was sandwiched between two XR-QA2 radiochromic films. In this setup, one radiochromic film is directly exposed to 100 mGy of the x-rays beam and another one measures the attenuated beam. After storage for 24 hours at room temperature under no light conditions, the irradiated radiochromic films were scanned under the same conditions in order to obtain a more reliable result. All films were scanned using the same size ROI in high resolution mode and saved as tagged image file format (TIFF). The untreated scanned image of the XR-AQ2 film directed exposed to the X-ray beam and the correspondent treated image with digital filters are shown. The untreated and treated image of the XR-AQ2 film that was exposed to the attenuated x-ray beam is shown. The image treated with digital filters seems to reproduce the dispersion of ZrO{sub 2} nano-sized grain clusters in the P(VDF-TrFE) copolymer matrix. This result is also discussed in terms of the high Z halides added to the sensitive layer of XR-AQ2 film and compared to the MEV images obtained from the P(VDF-TrFE)/ZrO{sub 2} composites. The results indicate a clear correlation between the 2D radiochromic image and the MEV photography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ x-ray absorption study of copper films in ground watersolutions

This study illustrates how the damage from copper corrosion can be reduced by modifying the chemistry of the copper surface environment. The surface modification of oxidized copper films induced by chemical reaction with Cl{sup -} and HCO{sub 3}{sup -} in aqueous solutions was monitored by in situ X-ray absorption spectroscopy. The results show that corrosion of copper can be significantly reduced by adding even a small amount of sodium bicarbonate. The studied copper films corroded quickly in chloride solutions, whereas the same solution containing 1.1 mM HCO{sub 3}{sup -} prevented or slowed down the corrosion processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DEVELOPMENT OF ENSEMBLE-BASED PROBABILISTIC FLOOD MAPS FOR PROBABLE MAXIMUM FLOOD

The magnitude and frequency of hydro-meteorological extremes are expected to increase in a changing environment that threaten the security of US energy-water assets. This includes probable maximum precipitation (PMP) and probable maximum flood (PMF) which are used as hydraulic design standards for critical infrastructures such as major hydropower reservoirs and nuclear power plants. To assess the potential flood hazards due to PMP/PMF, an integrated high resolution process-based hydro-meteorologic modeling framework was utilized to develop ensemble-based probabilistic flood maps based on best-available historic observations and future climate projections. A graphical process unit accelerated 2-dimensional hydrodynamic model was used to simulate the surface inundation areas corresponding to a total of PMF hydrographs. These ensemble-based PMF maps were compared with flood maps obtained from the conventional deterministic PMP/PMF approach, revealing added information of conditional probability of flooding. Further, a relative sensitivity test was conducted to explore the effects of various factors in the framework such as meteorological forcings, antecedent hydrologic conditions, reservoir storage, and flood model input resolution and parameters. The proposed framework better illustrates the uncertainties associated with model inputs, parameterization and hydro-meteorological factors allowing more informed decision-making for future emergency preparation.

13 HYDRO ENERGY↗