Search NASA⌕ Search

SEARCH · Search NASA

Results for “Behavior analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Testing $f(R)$ gravity with scale dependent cosmic void velocity profiles

Here, we study the impact of cosmological scale modifications to general relativity on the dynamics of halos within voids by comparing N-body simulations incorporating Hu-Sawicki f(R) gravity, with |f R0 | = 10 -6 and 10 -5 , to those of Λ CDM. By examining the radial velocity statistics within voids classified based on their size and density-profile, as “rising” (R-type) or “shell” (S-type), we find that halo motions in small R-type voids, with effective radius <15 Mpc/h, reveal distinctive differences between f(R) and Λ CDM cosmologies. To understand this observed effect, we study the linear and nonlinear fifth forces, and develop an iterative algorithm to accurately solve the nonlinear fifth force equation. We use this to characterize the Chameleon screening mechanism in voids and contrast the behavior with that observed in gravitationally collapsed objects. The force analysis underscores how smaller R-type voids exhibit the highest ratios of fifth force to Newtonian force, which source distinguishable differences in the velocity profiles and thereby provide rich environments in which to constrain gravity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation and Differentiation of Unique High- Q Optical Resonances Near Zero Wave Vector in Macroscopic Photonic Crystal Slabs

We demonstrate and distinguish here experimentally the existence of a special type of Fano resonances at $\mathbf{k}{\approx}\mathbf{0}$ in a macroscopic two-dimensional photonic crystal slab. We fabricate a square lattice array of holes in a silicon nitride layer and perform an angular resolved spectral analysis of the various Fano resonances. We elucidate their radiation behavior using temporal coupled-mode theory and symmetry considerations. The unique simplicity of this system whereby an ultralong lifetime delocalized electromagnetic field can exist above the surface and consequently easily interact with added matter, provides exciting new opportunities for the study of light and matter interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Building a better equation for electron transport estimated from Chl fluorescence: accounting for nonphotosynthetic light absorption

Chlorophyll fluorescence measurements of electron transport rate are an important companion of gas exchange analysis of photosynthesis. Detailed models allow prediction of gas exchange behavior based on fluorescence measurements, critical for converting low–throughput photosynthetic measurements to greater scales. Recently, a problem with using fluorescence–estimated electron transport rates in red vs blue light was discussed. The explanation was that high absorptance of blue light leads to saturation of photosystems near the light–exposed surface, but the red measuring beam may sample deeper in the leaf. In this case, fluorescence will report the quantum yield of photosystem II (ΦII) averaged from different photosystems than those that are important for the carbon–based quantum yield. The photosystems lower in the mesophyll will absorb less light, but will have a higher ΦII than tissues nearer the light–exposed surface, and so electron transport will be overestimated. Here, the overestimation caused by this sampling error will be higher for wavelengths of light that are more strongly absorbed, so it will be highest under blue actinic light and lowest under green actinic light. Based on this effect, some investigators are now choosing to use the minimum amount of blue needed to open stomata to minimize the overestimation of electron transport from blue light during gas exchange measurements.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement with microscopic MRI and simulation of flow in different aneurysm models

Purpose: The impact and the development of aneurysms depend to a significant degree on the exchange of liquid between the regular vessel and the pathological extension. A better understanding of this process will lead to improved prediction capabilities. The aim of the current study was to investigate fluid-exchange in aneurysm models of different complexities by combining microscopic magnetic resonance measurements with numerical simulations. In order to evaluate the accuracy and applicability of these methods, the fluid-exchange process between the unaltered vessel lumen and the aneurysm phantoms was analyzed quantitatively using high spatial resolution. Methods: Magnetic resonance flow imaging was used to visualize fluid-exchange in two different models produced with a 3D printer. One model of an aneurysm was based on histological findings. The flow distribution in the different models was measured on a microscopic scale using time of flight magnetic resonance imaging. The whole experiment was simulated using fast graphics processing unit-based numerical simulations. The obtained simulation results were compared qualitatively and quantitatively with the magnetic resonance imaging measurements, taking into account flow and spin–lattice relaxation. Results: The results of both presented methods compared well for the used aneurysm models and the chosen flow distributions. The results from the fluid-exchange analysis showed comparable characteristics concerning measurement and simulation. Similar symmetry behavior was observed. Based on these results, the amount of fluid-exchange was calculated. Depending on the geometry of the models, 7% to 45% of the liquid was exchanged per second. Conclusions: The result of the numerical simulations coincides well with the experimentally determined velocity field. The rate of fluid-exchange between vessel and aneurysm was well-predicted. Hence, the results obtained by simulation could be validated by the experiment. The observed deviations can be caused by the noise in the measurement and by the limited resolution of the simulation. The resulting differences are small enough to allow reliable predictions of the flow distribution in vessels with stents and for pulsed blood flow.

60 APPLIED LIFE SCIENCES↗

Role of dynamical effects in the formation of T-Odd asymmetries for products of polarized-neutron-induced ternary fission of nuclei

Basic dynamical effects that accompany the cold-polarized-neutron-induced binary and ternary fission of actinide nuclei and which determine the properties of T -odd asymmetries in angular distributions of various prescission and evaporated light third particles emitted in true and delayed ternary fission are analyzed on the basis of quantum-mechanical fission theory. It is emphasized that effects associated with the conservation of axial symmetry of the fissioning system under study at all stages of its evolution from the formation of neutron resonance states of the fissile compound nucleus to the separation of its fission fragments, including the appearance of zero wriggling vibrations of the cold compound nucleus in the vicinity of its scission point, are of particular importance, the influence of quantum collective rotation of the polarized fissile system on the asymmetry of the angular distribution of both fission fragments and third particles being taken into account. It is shown that the difference in the behavior of the coefficients characterizing the T -odd asymmetries under analysis for the target nuclei being studied can be explained, upon taking into account the interference between the fission amplitudes for the neutron resonance states of fissile compound nuclei, by the difference in the contributions of even and odd components of the amplitudes of angular distributions of third particles to the coefficients in question.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Compatibilization Strategy and Mechanism for Co-stabilizing Commingled Plastics and Pyrolyzed Rubber in Asphalt

Hot mix asphalt mixture is considered the ideal approach to reuse waste plastics in high-value applications because of its very high amount of usage in highway construction. However, the differences in polarity and density between polymers and asphalt lead to polymer coalescence and therefore the poor storage stability of modified asphalt. These challenges are exalted when recycling commingled plastics. This study introduced an innovative compatibilization strategy and mechanism for co-stabilizing commingled plastics and pyrolyzed rubber in asphalt. Commingled plastics were first grafted with maleic anhydride for surface activation, followed by reactive kneading with pyrolyzed rubber and crosslinking agent to form an integrated thermoplastic elastomer (ITPE) for asphalt modification. The mechanical, thermal, and interfacial behaviors of the ITPE were evaluated through tensile testing, thermogravimetric analysis, and scanning electron microscopy. The storage stability and rheological properties of the modified binder blends were evaluated through the cigar tube test and dynamic shear rheometer testing. Results demonstrated a successful formation of imide bonds in the ITPE, which can improve the strength, ductility, and thermal stability of rubber–plastic composites. Appropriate utilization of crosslinking agents can improve both rutting and fatigue resistance of ITPE-modified asphalt with good storage stability because of the co-existence of rigid plastic and soft rubbery regimes and the formation of a crosslink network. Furthermore, excessive content of crosslinker led to severe phase separation and reduced storage stability of modified binder blends. Extra crosslinker tended to float in asphalt because of its low density and caused an excessive formation of the crosslink network in the top section of the asphalt.

asphalt binder modifiers↗

A National Survey of Skin Infections, Care Behaviors and MRSA Knowledge in the United States

A nationally representative sample of approximately 2000 individuals was surveyed to assess SSTI infections over their lifetime and then prospectively over six-months. Knowledge of MRSA, future likelihood to self-treat a SSTI and self-care behaviors was also queried. Chi square tests, linear and multinomial regression were used for analysis. About 50% of those with a reported history of a SSTI typical of MRSA had sought medical treatment. MRSA knowledge was low: 28% of respondents could describe MRSA. Use of protective self-care behaviors that may reduce transmission, such as covering a lesion, differed with knowledge of MRSA and socio-demographics. Those reporting a history of a MRSA-like SSTI were more likely to respond that they would self-treat than those without such a history (OR 2.05 95% CI 1.40, 3.01; p<0.001). Since half of respondents reported not seeking care for past lesions, incidence determined from clinical encounters would greatly underestimate true incidence. MRSA knowledge was not associated with seeking medical care, but was associated with selfcare practices that may decrease transmission.

59 BASIC BIOLOGICAL SCIENCES↗

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Typhoon IB Performance

While running fundamental IB verbs testing on the Typhoon cluster, it was discovered that IB performance was not satisfactory for a QDR system. The theoretical maximum bandwidth expected on a QDR system is 32Gb/sec. After significant testing and analysis, RDMA read performance was consistently shown to be 50% lower than RDMA write performance, resulting in significantly less than half the theoretical maximum. Thorough testing and analysis identified a BIOS setting as the reason for this behavior.

97 MATHEMATICS AND COMPUTING↗

Fracture Toughness Prediction for MWCNT Reinforced Ceramics

This report describes the development of a micromechanics model to predict fracture toughness of multiwall carbon nanotube (MWCNT) reinforced ceramic composites to guide future experimental work for this project. The modeling work described in this report includes (i) prediction of elastic properties, (ii) development of a mechanistic damage model accounting for matrix cracking to predict the composite nonlinear stress/strain response to tensile loading to failure, and (iii) application of this damage model in a modified boundary layer (MBL) analysis using ABAQUS to predict fracture toughness and crack resistance behavior (R-curves) for ceramic materials containing MWCNTs at various volume fractions.

36 MATERIALS SCIENCE↗

FINAL REPORT. DOE Grant Award Number DE-SC0004062

With the support of the DOE-OFES Early Career Award and the Tufts startup support the PI has developed experimental and analytical expertise on the electromechanical characterization of Low Temperature Superconductor (LTS) and High Temperature Superconductor (HTS) for high magnetic field applications. These superconducting wires and cables are used in fusion and high-energy physics magnet applications. In a short period of time, the PI has built a laboratory and research group with unique capabilities that include both experimental and numerical modeling effort to improve the design and performance of superconducting cables and magnets. All the projects in the PI’s laboratory explore the fundamental electromechanical behavior of superconductors but the types of materials, geometries and operating conditions are chosen to be directly relevant to real machines, in particular fusion machines like ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Annular Core Research Reactor Pulse History Report: 2003-2017

This report documents and describes the tabulation and analysis of historical pulse operation data from the Annular Core Research Reactor (ACRR) at Sandia National Laboratories (SNL). The pulse data was obtained from a combination of pulse log files generated at the control console and pulse diagnostics system data. The pulses presented were performed within the time period of April 2003 and December 2017. A brief analysis of the data is included to characterize the aggregate behavior of ACRR pulses with respect to theoretical treatments based on the point reactor kinetics model. It is expected that the data presented will provide an organized and consolidated resource to reference historical pulse data at the ACRR for use in analyses, verification and validation, and general understanding of the machine. A comprehensive set of data is presented to the reader in the appendices.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spark Breakdown Threshold in Non-Uniform Fields

We develop a criterion for spark breakdown in non-uniform field geometries with positive polarity and small electrode separations so that breakdown evolves without the formation of a leader. We arrive at the spark-breakdown criterion by framing it in terms of gain and instability conditions, whose relative importance are established from an analysis of the experimental breakdown characteristics and correlations with streamer behavior in short gaps. Results are presented in the context of two generic geometries having coaxial and point-plane electrodes. For nearly uniform field situations, we re-confirm that the breakdown criterion obtained by the usual extension of either the Townsend or Meek criteria satisfactorily predicts the experimental results. On the other hand, for increasing non-uniformity, the results for the corona and spark branches of the breakdown characteristics are shown inconsistent with a breakdown criterion solely based on either the Townsend or streamer mechanisms. In particular, the avalanche gain factor, the primary component of the Townsend and streamer criteria does not determine the spark breakdown criterion. Streamers can cross the gap for a significantly wide range of applied voltages without triggering a spark. We find that it is the instability condition, derived from a relation between the minimum Laplacian field in the gap and the local streamer body field (which we relate to the streamer sustaining field), that is sufficient for determining the spark threshold thereby yielding a breakdown criterion. We examine the physics of the discharge occurring in the several parts of the nonuniform field gap to elucidate the underpinning of the threshold criterion. These include streamer stability and branching in the stressed electrode region, cathode fall setup near the planar-type electrode, and importantly, the renewed ionization of the discharge resulting from neutral expansion of the gas discharge driven by currents, which are critically dependent on the minimum field level in the gap. We also discuss experiments which were carried out to examine instabilities associated with the streamer breakdown of uniform gaps with triggering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Methodology to Evaluate the Grid Reliability Impact of Oscillations Induced by Large Loads

The rapid growth of hyperscale AI data centers is bringing renewed attention to the reliability risk that sustained forced oscillations pose to bulk power systems, with cyclic computational workloads emerging as a new forcing source. Unlike the broadband, stochastic disturbances from traditional industrial loads such as arc furnaces, AI training and inference facilities can inject large active power swings concentrated at specific frequencies over extended durations - characteristics that existing grid planning practices do not account for. While the North American Electric Reliability Corporation (NERC) has recognized this gap and called for system-level studies of large load interconnections, no standardized methodology exists to screen, simulate, and quantify these risks at the planning stage. This report presents the Risk Assessment Tool for Large Load-induced Events (RATLLE), a Python-based, publicly available script suite developed at the Pacific Northwest National Laboratory to evaluate bulk power system reliability risks from data center-induced oscillations. RATLLE implements a three-module workflow: a screening module that identifies vulnerable interconnection locations and excitable system modes; a simulation module that models cyclic data center load behavior using a commercial positive sequence simulation platform; and an analysis module that computes risk metrics and generates interactive visualization dashboards. The risk metrics, formulated around simulation observables, map oscillation impacts to a three-stage severity scale spanning latent equipment fatigue through imminent cascading failure. The methodology is demonstrated on two Western Electricity Coordinating Council (WECC) system models: a publicly available 240-bus reduced representation and a detailed 2031 Heavy Winter planning case. Case studies illustrate that even modest 50 MW forced oscillations at resonant frequencies can produce wide-area power swings, N-1 security constraint violations, and cascading generator trips through protection actions - outcomes that would not occur under normal operating conditions without oscillations present. The results underscore the need for standardized oscillation impact assessment in large load interconnection studies and provide a reproducible, extensible framework for utilities to adopt or customize within their existing planning workflows.

Biswas, Shuchismita↗

Cascaded Control for Building HVAC Systems in Practice

Actuator hunting is a widespread and often neglected problem in the HVAC field. Hunting is typically characterized by sustained or intermittent oscillations, and can result in decreased efficiency, increased actuator wear, and poor setpoint tracking. Cascaded control loops have been shown to effectively linearize system dynamics and reduce the prevalence of hunting. This paper details the implementation of cascaded control architectures for Air Handling Unit chilled water valves at three university campus buildings. A framework for implementation the control in existing Building Automation software is developed that requires only a single line of additional code. Results gathered for more than a year show that cascaded control not only eliminates hunting in control loops with documented hunting issues, but provides better tracking and more consistent performance during all seasons. A discussion of efficiency losses due to hunting behavior is presented and illustrated with comparative data. Furthermore, an analysis of cost savings from implementing cascaded chilled water valve control is presented. Field tests show 2.2–4.4% energy savings, with additional potential savings from reduced operational costs (i.e., maintenance and controller retuning).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bacterial-Retted Hemp Fiber/PLA Composites

The push for sustainability in all facets of manufacturing has led to an increased interest in biomass as an alternative to non-renewable materials. Hemp bast fiber mats were produced from a bacterial retting process, named BFM, as the fiber reinforcement. The objective of this study was to evaluate the feasibility of laminating BFM with polylactic acid (PLA) for a composite panel product. Since both BFM and PLA are biodegradable, the resulting BFM-PLA composites will be 100% biodegradable. PLA pallets were processed into thin polymer sheets which served as the matrix. The BFM and PLA plates were laminated in five layers and compression-molded into composite panels. Experiments were conducted on the three BFM-to-PLA ratios (35/65, 45/55, and 50/50). Mechanical properties (tensile and bending properties) and physical properties (thickness swell and water absorption) were tested and compared to the currently commercial sheet molding compound (SMC) from fiber glass. The thermal behavior of the BFM/PLA composites was characterized using dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC). The developed BFM/PLA composite product is a sustainable alternative to existing synthetical fiber-reinforced polymer (FRP) that is biodegradable in landfill at the end of life.

Smith, Lee M. (ORCID:0000000264390357)↗

Landscaper v1

Understanding the inner workings of machine learning models through their loss landscapes offers crucial insights into model properties, optimization dynamics, and generalizability. However, accessing these insights has traditionally required specialized mathematical expertise, limiting broader adoption. Landscaper is an open-source Python package designed to bridge this gap. Landscaper seamlessly integrates a suite of multi-dimensional loss landscape analyses with cutting-edge topological data analysis (TDA) methods. This powerful combination makes both fundamental loss landscape analysis and advanced TDA techniques accessible to the broader scientific ML community, without requiring deep pre-existing mathematical knowledge. Landscaper offers three key functionalities: * Construction: Builds detailed loss landscape representations through versatile low and high-dimensional sampling techniques. * Quantification: Applies advanced metrics, including a novel topological data analysis (TDA) based smoothness metric, enabling new perspectives on model behavior. * Visualization: Offers intuitive tools to visualize and interpret loss landscapes, providing actionable insights beyond traditional performance metrics.

Weber, Gunther [Lawrence Berkeley National Laborat↗

Data Filtering Impact on PV Degradation Rates and Uncertainty (Poster)

To sustain the commercial success of photovoltaics (PV) it becomes vital to know how power output decreases with time. In order to predict power delivery, degradation rates must be determined accurately. Data filtering, any data treatment assessment of long-term field behavior, is discussed as part of a more comprehensive uncertainty analysis and can be one of the greatest sources of uncertaintyin long-term performance studies. Several distinct filtering methods such as outlier removal and inclusion of only sunny days on several different metrics such as PVUSA, performance ratio, DC power to plane-of-array irradiance ratio, uncorrected, and temperature-corrected were examined. PVUSA showed the highest sensitivity while temperature-corrected power over irradiance ratio was found to bethe least sensitive to data filtering conditions. Using this ratio it is demonstrated that quantification of degradation rates with a statistical accuracy of +/- 0.2%/year within 4 years of field data is possible on two crystalline silicon and two thin-film systems.

14 SOLAR ENERGY↗