Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Contamination character of materials in space technology testing.

Determination of the nature and degree of contamination of mirrors in a vacuum environment in the presence of UV irradiation by outgases from some materials that are candidates for use inside spacecraft and simulated spacecraft environments. A vacuum apparatus was developed for testing contamination of mirrors. Offgases from heated test materials are deposited on a refrigerated mirror, half of which is UV irradiated. Reflectance is measured between 1100 and 25,000 A. Thermofit RNF-100, insulated wire TRT-24-19-V-93, and Eccofoam FS and FPH gave heavier deposits on the nonirradiated mirror. Moxness MS60 SO8, Scotch Tape Y-9050, RTV-577, RTV-41, Stycast 1090, and Epon 934 and 828 gave heavier deposits on the irradiated mirror. Raychem wire 44/0411, polyimide tape X1156, Insulgrease G-640, High Vacuum Silicone Grease, and RTV-602 gave only slight deposits on the irradiated and nonirradiated areas of the mirror.

Coulson, D. M.↗

Estimating sorber capacity for multiple contaminants

Computer program estimates quantity of activated charcoal required to control multiple contaminants. Program scans all contaminants by potential parameter value and then orders them from lowest to highest values. It calculates quantity of sorbent required to remove most strongly adsorbed material; and then, using potential plot data, capacity of other materials is calculated on basis of corrected capacity.

Olcott, T. M.↗

The probabilistic structure of planetary contamination models

The analytical basis for planetary quarantine standards and procedures is presented. The heirarchy of planetary quarantine decisions is explained and emphasis is placed on the determination of mission specifications to include sterilization. The influence of the Sagan-Coleman probabilistic model of planetary contamination on current standards and procedures is analyzed. A classical problem in probability theory which provides a close conceptual parallel to the type of dependence present in the contamination problem is presented.

Harrison, J. M.↗

Analytical study of spacecraft deposition contamination by internal reflection spectroscopy

Infrared absorption spectra of ten individual contaminant materials and four binary mixtures of these have been studied using the internal reflection spectroscopy technique. The effect of ultraviolet radiation on these contaminants has also been studied. It has been observed that all siloxanes, silanes, and esters are drastically affected by ultraviolet irradiation. In most cases polymerization and tar formation results.

Mookherji, T.↗

Probabilistic models of planetary contamination

Likely fundamental inadequacies in the model of planetary contamination advanced by Sagan and Coleman are discussed. It is shown that a relatively minor modification of the basic Sagan-Coleman formula yields approximations that are generally adequate with data in the range of interest. This approximation formula differs from the original Sagan-Coleman version only through an initial conditioning on landing outcome. It always yields an upper (conservative) bound for the total probability of contamination, this appealing feature is lost if the conditioning on landing outcome is deleted.

Harrison, J. M.↗

ATS-F radiant cooler contamination test in a hydrazine thruster exhaust

A test was conducted under simulated space conditions to determine the potential thermal degradation of the ATS-F radiant cooler from any contaminants generated by a 0.44-N(0.1-lbf) hydrazine thruster. The radiant cooler, a 0.44-N(0.1-lbf)hydrazine engine, and an aluminum plate simulating the satellite interface were assembled to simulate their flight configuration. The cooler was provided with platinum sensors for measuring temperature, and its surfaces were instrumented with six quartz crystal microbalance units (QCM) to measure contaminant mass deposits. The complete assembly was tested in the molecular sink vacuum facility (Molsink) at the Jet Propulsion Laboratory. This was the first time that a radiant cooler and a hydrazine engine were tested together in a very-high-vacuum space simulator, and this test was the first successful measurement of detectable deposits from hydrazine rocket engine plumes in a high vacuum. The engine was subjected to an accelerated duty cycle of 1 pulse/min, and after 2-hr of operation, the QCMs began to shift in frequency. The tests continued for several days and, although there was considerable activity in the QCMs, the cooler never experienced thermal degradation.

Chirivella, J. E.↗

Design principles for contamination abatement in scientific satellites.

It is shown that deposition of contamination films on satellite optics can be controlled by the following means: isolating critical optical surfaces from the rest of the spacecraft; avoiding or minimizing the use of nonmetallic material, particularly near or in line of sight of optical surfaces; avoiding materials with high vapor pressures; subjecting materials to vacuum baking prior to use, to drive off the volatile outgassing products; keeping the critical surfaces at temperatures above the ambient; avoiding elevated operational temperatures for nonmetallic materials; paying special attention to optics exposed to intense UV-, X-ray, or particular radiation; avoiding water-vapor sources; and directing RCS plumes away from critical surfaces. Methods of controlling particulate contaminants are also proposed.

Naumann, R. J.↗

ATM C and D panel/EREP cooling system contamination problem

This report presents the history of a preflight contamination problem that occurred in the ATM C and D panel/EREP cooling system on the Skylab, the studies that were made to determine the cause of the problem, and corrective actions that were made prior to lift-off. The results of all the observations, analyses and laboratory testing indicated that the contamination came from one or more of the EREP tape recorder coldplates and was caused by some abnormal electrolytic action, either during bench testing or in the spacecraft. Studies indicate that no such electrolytic action is likely to occur under normal operating conditions.

Williamson, J. G.↗

Monitoring systems for evaluation of terrestrial contamination in a lunar sample transfer facility

The lunar sample transfer facility used consists of two tandem glove boxes and an entrance vacuum antechamber. Monitoring systems were used to evaluate the contamination levels of water, permanent gases, and lower volatility organic compounds in the glove box atmosphere. The experimental procedures are considered, taking into account the glove box atmosphere, aspects of volatile gas analysis, and lower volatility organic contaminants. The value of high resolution mass spectrometry in the monitoring scheme is illustrated with the aid of an example.

Wszolek, P. C.↗

New methodology for assessing the probability of contaminating Mars

Methodology is proposed to assess the probability that the planet Mars will be contaminated by terrestrial microorganisms aboard a spacecraft. The present NASA methods are extended to permit utilization of detailed information on microbial characteristics, the lethality of release and transport mechanisms, and of other information about the Martian environment. Different types of microbial release are distinguished, and for each release mechanism a probability of growth is computed. Using this new methodology, an assessment was carried out for the 1975 Viking landings on Mars. The resulting probability of contamination for each Viking lander is 6 x 10 to the -6 power, and is amenable to revision as additional information becomes available.

North, D. W.↗

Payload/orbiter contamination control requirement study, volume 2, exhibit A

The computer printout data generated during the Payload/Orbiter Contamination Control Requirement Study are presented. The computer listings of the input surface data matrices, the viewfactor data matrices, and the geometric relationship data matrices for the three orbiter/spacelab configurations analyzed in this study are given. These configurations have been broken up into the geometrical surfaces and nodes necessary to define the principal critical surfaces whether they are contaminant sources, experimental surfaces, or operational surfaces. A numbering scheme was established based upon nodal numbers that relates the various spacelab surfaces to a specific surface material or function. This numbering system was developed for the spacelab configurations such that future extension to a surface mapping capability could be developed as required.

Bareiss, L. E.↗

Skylab atmospheric contamination control

The Skylab contamination removal systems, preflight analysis and testing, and flight results are described. Results indicate that the combination of materials selection, the onboard removal devices, and the offgassing tests proved to be an effective means of controlling spacecraft contaminant levels.

Ray, C. D.↗

Bibliography on contaminants and solubility of organic compounds in oxygen

A compilation of a number of document citations is presented which contains information on contaminants in oxygen. Topics covered include contaminants and solubility of organic compounds in oxygen, reaction characteristics of organic compounds with oxygen, and sampling and detection limits of impurities. Each citation in the data bank contains many items of information about the document. Some of the items are title, author, abstract, corporate source, description of figures pertinent to hazards or safety, key references, and descriptors (keywords) by which the document can be retrieved. Each citation includes an evaluation of the technical contents as to being good/excellent, acceptable, or poor. The descriptors used to define the contents of the documents and subsequently used in the computerized search operations were developed for the cryogenic fluid safety by experts in the cryogenics field.

Ordin, P. M.↗

Determination of space vehicle contamination

The contamination and degradation of externally exposed sensitive experimental and functional surfaces of the Skylab by the self-induced atmosphere surrounding the vehicle are studied. It is shown that the major contamination sources of long-term deposits on Skylab are primarily outgassing from nonmetallic coatings and rocket engine exhaust products. Analysis showed that the characteristic decay time of the outgassing source rate may be as long as 4100 hr, and that essentially 20% of RCS deposits that stick at temperatures of 0 C will remain after sublimating at a rate whose characteristic decay time is 72 hr.

Rantanen, R. O.↗

Experiment to measure enhancement of spacecraft contamination by spacecraft charging

An ambitious effort to measure contamination on a highly instrumental spacecraft is being carried out. Spacecraft contamination enhancement by spacecraft charging is described. A brief summary of the motivation for and the capabilities of the Spacecraft Charging at High Altitudes (SCATHA) Spacecraft is given. The experimental approach is described and summaries are given of previous spaceflight experiments in which similar instrumentation has been used. A description of the experimental flight hardware planned for SCATHA is included.

Hall, D. F.↗

A system for the study of molecular contamination

An experimental vacuum chambers was designed and fabricated to provide a wide range of experimental capability. This work chamber assembly (WCA) was conceived to establish the proof-of-principle of various techniques for studying the kinetics of contaminants and their effects. It incorporates the capability for depositing both optical and contaminant films on temperature-controlled samples, and for in-situ measurements of the vacuum ultraviolet reflectance. Ellipsometer optics are mounted on the chamber for film thickness determinations, and other features include access ports for radiation sources and instrumentation.

Dillow, C. F.↗

Particulate size distribution cascade analyzer for spacecraft contamination monitoring

A cascade particulate analyzer was developed for nearly real time measurement of the contaminating particulate size distribution in the spacecraft interior ambient environment and as a real time total impacting particulate mass monitor under vacuum conditions. The analyzer has four stages, the first stage is a basic 10 MHz quartz crystal microbalance used widely on spacecraft (such as Skylab) for contamination monitoring purposes. In this application the front sensing crystal is coated with a low vapor pressure adhesive grease which captures impacting particles. This first stage has a wide viewing angle and measures total particulate mass impacting the crystal while the unit is exposed to the vacuum environment. The remaining three states form an aerodynamic impaction cascade with individual quartz crystal microbalances at each stage acting as accumulated mass sensing elements. These three stages thus give relative mass distribution of particulates in three ranges, particles having effective diameter greater than 5 micron, particles between 1 and 5 micron diameter and particles 0.3 to 1 micron diameter.

Wallace, D. A.↗