Variations in Linear Energy Transfer Within Clinical Proton Therapy Fields and the Potential for Biological Treatment Planning

Purpose: To calculate the linear energy transfer (LET) distributions in patients undergoing proton therapy. These distributions can be used to identify areas of elevated or diminished biological effect. The location of such areas might be influenced in intensity-modulated proton therapy (IMPT) optimization. Methods and Materials: Because Monte Carlo studies to investigate the LET distribution in patients have not been undertaken so far, the code is first validated with simulations in water. The code was used in five patients, for each of them three planning and delivery techniques were simulated: passive scattering, three-dimensional modulation IMPT (3D-IMPT), and distal edge tracking IMPT (DET-IMPT). Results: The inclusion of secondary particles led to significant differences compared with analytical techniques. In addition, passive scattering and 3D-IMPT led to largely comparable LET distributions, whereas the DET-IMPT plans resulted in considerably increased LET values in normal tissues and critical structures. In the brainstem, dose-averaged LET values exceeding 5 keV/{mu}m were observed in areas with significant dose (>70% of prescribed dose). In noncritical normal tissues, even values >8 keV/{mu}m occurred. Conclusion: This work demonstrates that active scanning offers the possibility of influencing the distribution of dose-averaged LET (i.e., the biological effect) without significantly altering the distribution of physical dose. On the basis of this finding, we propose a method to alter deliberately the LET distribution of a treatment plan in such a manner that the LET is maximized within certain target areas and minimized in normal tissues, while maintaining the prescribed target dose and dose constraints for organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Air Activation Calculations for Electron Linear Accelerators - Paper 114

Electron linear accelerators produce x-ray photons when the beam interacts with material such as beam stops or beamline components. These photons subsequently cause radioactivation in air, primarily through ({gamma},n) reactions. While most of these nuclides have short half-lives, they can lead to doses to personnel entering the accelerator or experimental areas and can be released to the environment. Accurate calculations are needed for the production, decay, and clearance of these nuclides. This paper discusses two treatments of air activation. An approximate treatment makes use of the fact that the Bremsstrahlung photon fluence is proportional to beam power and the path length in air, but does not account for heavily shielded loss points or how far the beam energy is above each reaction threshold. Using detailed radiation transport codes like MCNPX avoids these problems. Examples are provided for two electron linear accelerators at Argonne National Laboratory: the Low-Energy Accelerator Facility (LEAF) and the Argonne Wakefield Accelerator (AWA). MCNPX was used to calculate photonuclear reaction rates in the air at two electron accelerators at Argonne. Combined with realistic models for air exhaust, these results were used to calculate effects to facility staff, other personnel, and the environment. (authors)

43 PARTICLE ACCELERATORS↗

TU-AB-201-09: Calibration of An Element of a New Directional Pd-103 Planar Source Array

Purpose: The CivaSheet™ is a new directional Pd-103 planar source array, with a variable number of discrete source elements referred to as “dots”. Each dot consists of a polymer capsule containing {sup 103}Pd and a gold shield that attenuates radiation on one side of the device to define hot and cold dose regions. Fluorescence from the gold shield is observed in the dot spectrum. Since CivaSheet™ is a planar directional source, conventional methods used for calibration of azimuthally symmetric sources are not applicable. The purpose of this work is to establish an air-kerma-strength standard and a transfer to a well chamber for clinical calibration. Methods: Primary air-kerma strength measurement of the dots was performed using a variable-aperture free-air chamber (VAFAC). Charge measurements were recorded using a well chamber with a custom insert. Anisotropy measurements were performed using a Sodium-Iodide detector. Spectral measurements were performed using a low-energy germanium detector and compared to a source without gold. The dot geometry was modeled using the MCNP6 radiation transport code. Results: Air-kerma strength measurements of a batch of four dots performed with the VAFAC were within ±1.5% of the average measured value and the measurement precision was within ±0.5%. Anisotropy measurements indicated uniform emission within the measurement uncertainty for the solid angle defining the VAFAC aperture used. Charge measurements of each dot using the well chamber in four cardinal angle source orientations were within ±1.5% of the average measured values. The spectral study of a dot resulted in identification of fluorescence from the gold shield and primary spectral energies that were compared to MCNP6 simulations. Conclusion: Calibration procedures for the new directional Pd-103 source dot were established for future clinical use, based on the results of experimental and Monte Carlo investigations. This work was partially supported by NCI contract (HHSN261201200052C) through CivaTech Oncology Inc.

60 APPLIED LIFE SCIENCES↗

An Updated Performance Assessment For A New Low-Level Radioactive Waste Disposal Facility In West Texas - 12192

This Performance Assessment (PA) submittal is an update to the original PA that was developed to support the licensing of the Waste Control Specialists LLC Low-Level Radioactive Waste (LLRW) disposal facility. This update includes both the Compact Waste Facility (CWF) and the Federal Waste Facility (FWF), in accordance with Radioactive Material License (RML) No. R04100, License Condition (LC) 87. While many of the baseline assumptions supporting the initial license application PA were incorporated in this update, a new transport code, GoldSim, and new deterministic groundwater flow codes, including HYDRUS and MODFLOWSURFACT{sup TM}, were employed to demonstrate compliance with the performance objectives codified in the regulations and RML No. R04100, LC 87. A revised source term, provided by the Texas Commission on Environmental Quality staff, was used to match the initial 15 year license term. This updated PA clearly confirms and demonstrates the robustness of the characteristics of the site's geology and the advanced engineering design of the disposal units. Based on the simulations from fate and transport models, the radiation doses to members of the general public and site workers predicted in the initial and updated PA were a small fraction of the criterion doses of 0.25 mSv and 50 mSv, respectively. In a comparison between the results of the updated PA against the one developed in support of the initial license, both clearly demonstrated the robustness of the characteristics of the site's geology and engineering design of the disposal units. Based on the simulations from fate and transport models, the radiation doses to members of the general public predicted in the initial and updated PA were a fraction of the allowable 25 mrem/yr (0.25 m sievert/yr) dose standard for tens-of-thousands of years into the future. Draft Texas guidance on performance assessment (TCEQ, 2004) recommends a period of analysis equal to 1,000 years or until peak doses from the more mobile radionuclides occur. The EPA National Emissions Standards for Hazardous Air Pollutants limits radionuclide doses through the air pathway to 10 mrem/yr. Gaseous radionuclide doses from the CWF and the FWF, due to decomposition gases, are a small fraction of the dose limit. The radon flux from the CWF and FWF were compared to the flux limit of 20 pCi/m{sup 2}-s from 40 CFR 192. Because of the thick cover system, the calculated radon flux was a very small fraction of the limit. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structural Modification of Graphene on Copper Substrates Irradiated by Nanosecond High-Intensity Ion Beams

Interaction of a nanosecond high-intensity pulsed ion beam with thin graphene films on copper substrates is analyzed. Methods of Raman spectroscopy are used to investigate the degree of graphene degradation depending on the integral implanted dose. The role of the substrate in the structural degradation of graphene irradiated by charged particle beams is demonstrated using the software package SRIM, intended for modeling radiative defect cascades under irradiation by charged particle beams, and the data on radiation resistance of graphene available in the literature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Marine Sciences Laboratory Radionuclide Air Emissions Report for Calendar Year 2013

The U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest Site Office (PNSO) has oversight and stewardship duties associated with the Pacific Northwest National Laboratory (PNNL) Marine Sciences Laboratory (MSL) located on Battelle Land – Sequim (Sequim). This report is prepared to document compliance with the Code of Federal Regulations (CFR), Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (NESHAP), Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code (WAC) Chapter 246-247, “Radiation Protection–Air Emissions.” The EDE to the Sequim MEI due to routine operations in 2013 was 5E-05 mrem (5E-07 mSv). No non-routine emissions occurred in 2013. The MSL is in compliance with the federal and state 10 mrem/yr standard.

air emissions↗

Marine Sciences Laboratory Radionuclide Air Emissions Report for Calendar Year 2014

The U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest Site Office (PNSO) has oversight and stewardship duties associated with the Pacific Northwest National Laboratory (PNNL) Marine Sciences Laboratory (MSL) located on Battelle Land – Sequim.This report is prepared to document compliance with the Code of Federal Regulations (CFR), Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (NESHAP), Subpart H, ''National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code (WAC) Chapter 246-247, “Radiation Protection–Air Emissions.'' The EDE to the MSL MEI due to routine operations in 2014 was 9E-05 mrem (9E-07 mSv). No non-routine emissions occurred in 2014. The MSL is in compliance with the federal and state 10 mrem/yr standard.

54 ENVIRONMENTAL SCIENCES↗

TU-F-BRE-06: Flattening-Filter-Free Beam Quality Correction Factor Determination Using Experimental and Monte Carlo Methods

Purpose: To investigate beam quality correction factors for the flattening-filter-free (FFF) energies of the TrueBeam™ accelerator based on a dosimetry formalism for small and nonstandard fields. Methods: Three detectors - an Exradin W1 scintillator, Sun Nuclear EDGE diode, and LiF(Mg,Tl) TLD-100 chips - were investigated to determine their applicability as tools to measure quality correction factors for ionization chambers in the small and nonstandard fields of the TrueBeam™. Volume-averaging effects and energy dependence were observed in fields ranging from 1×1 to 40×40 cm{sup 2} for 6 MV and 10 MV beam energies using both FFF and flattened beam modes. Correction factors were determined for three ionization chambers: an Exradin A12 Farmer-type chamber, an Exradin A1SL scanning chamber, and an Exradin A26 reference-class microchamber. Beam quality corrections were also obtained using a benchmarked model of the TrueBeam™ created with the BEAMnrc user code of EGSnrc. Results: All three detectors demonstrated measureable energy dependence in the megavoltage range. The EDGE diode was deemed the most appropriate tool for beam quality correction factor measurements due to its low energy dependence and small size; however, alanine will be used in the future to reduce energy dependent effects even further. Measured k{sub Qmsr,Q} corrections of up to 4% were found for the 6MV FFF and 10 MV FFF beams, corresponding to a discrepancy of up to 3% compared to TG-51-determined dose. Up to a 10% k{sub Qclin,Qmsr} correction was measured for small fields referenced to a 10×10 cm{sup 2} field of the same energy. Much larger corrections were determined using the Monte Carlo model, and these discrepancies require further investigation. Conclusion: Progress has been made toward determining beam quality correction factors for the small and nonstandard fields of the TrueBeam™ accelerator. Further work must be done to ensure greater accuracy in patient treatments with this new modality.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-308: Mobius FX Evaluation and Comparison Against a Commercial 4D Detector Array for VMAT Plan QA

Purpose: To evaluate the use of MobiusFX as a pre-treatment verification IMRT QA tool and compare it with a commercial 4D detector array for VMAT plan QA. Methods: 15 VMAT plan QA of different treatment sites were delivered and measured by traditional means with the 4D detector array ArcCheck (Sun Nuclear corporation) and at the same time measurement in linac treatment logs (Varian Dynalogs files) were analyzed from the same delivery with MobiusFX software (Mobius Medical Systems). VMAT plan QAs created in Eclipse treatment planning system (Varian) in a TrueBeam linac machine (Varian) were delivered and analyzed with the gamma analysis routine from SNPA software (Sun Nuclear corporation). Results: Comparable results in terms of the gamma analysis with 99.06% average gamma passing with 3%,3mm passing rate is observed in the comparison among MobiusFX, ArcCheck measurements, and the Treatment Planning System dose calculated. When going to a stricter criterion (1%,1mm) larger discrepancies are observed in different regions of the measurements with an average gamma of 66.24% between MobiusFX and ArcCheck. Conclusion: This work indicates the potential for using MobiusFX as a routine pre-treatment patient specific IMRT method for quality assurance purposes and its advantages as a phantom-less method which reduce the time for IMRT QA measurement. MobiusFX is capable of produce similar results of those by traditional methods used for patient specific pre-treatment verification VMAT QA. Even the gamma results comparing to the TPS are similar the analysis of both methods show that the errors being identified by each method are found in different regions. Traditional methods like ArcCheck are sensitive to setup errors and dose difference errors coming from the linac output. On the other hand linac log files analysis record different errors in the VMAT QA associated with the MLCs and gantry motion that by traditional methods cannot be detected.

60 APPLIED LIFE SCIENCES↗

Experiment design for the neutron irradiation of $\mathrm{PM-HIP}$ alloys for nuclear reactors

Here, this article describes the design of an Advanced Test Reactor (ATR) drop-in neutron irradiation experiment aiming to directly compare the performance of nuclear structural alloys fabricated by powder metallurgy with hot isostatic pressing (PM-HIP) against conventional casting or forging. There is growing interest in PM-HIP alloys for nuclear applications because of their microstructural uniformity, superior mechanical properties, and reduced dependence on welding and machining, compared to cast/forged alloys. Nuclear code-qualification of PM-HIP alloys requires neutron irradiation testing to demonstrate performance under relevant conditions. In this experiment, six nuclear structural alloys were irradiated: Ni-based alloys 625 and 690, Grade 91 ferritic steel, SA508 pressure vessel steel, and 304L and 316L austenitic stainless steels. The experiment is assembled into seven capsules in four test trains and irradiated in three ATR inboard A positions. Both the PM-HIP and cast/forged versions of each alloy were irradiated under nearly identical conditions for comparative purposes, to target doses of 1 ± 0.2 and 3 ± 0.2 dpa at temperatures of 300 ± 50 °C and 400 ± 50 °C. A thorough description of the experiment design and thermal, structural and neutronic analyses performed to ensure the targeted irradiation conditions are met is provided. Specimens were configured as small disks, compact tension specimens and tensile bars to facilitate post-irradiation examination (PIE) that will include mechanical testing, microstructure characterization, and fracture toughness testing. Given the considerations for ASTM standardized mechanical testing, comparative fluence and temperature across specimen pairs, and comprehensive PIE planning herein, this work serves as a template for future nuclear materials qualification experiment designs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of SPECT corrections on 3D-dosimetry for liver transarterial radioembolization using the patient relative calibration methodology

Purpose: Many centers aim to plan liver transarterial radioembolization (TARE) with dosimetry, even without CT-based attenuation correction (AC), or with unoptimized scatter correction (SC) methods. This work investigates the impact of presence vs absence of such corrections, and limited spatial resolution, on 3D dosimetry for TARE. Methods: Three voxelized phantoms were derived from CT images of real patients with different body sizes. Simulations of {sup 99m}Tc-SPECT projections were performed with the SIMIND code, assuming three activity distributions in the liver: uniform, inside a “liver’s segment,” or distributing multiple uptaking nodules (“nonuniform liver”), with a tumoral liver/healthy parenchyma ratio of 5:1. Projection data were reconstructed by a commercial workstation, with OSEM protocol not specifically optimized for dosimetry (spatial resolution of 12.6 mm), with/without SC (optimized, or with parameters predefined by the manufacturer; dual energy window), and with/without AC. Activity in voxels was calculated by a relative calibration, assuming identical microspheres and {sup 99m}Tc-SPECT counts spatial distribution. 3D dose distributions were calculated by convolution with {sup 90}Y voxel S-values, assuming permanent trapping of microspheres. Cumulative dose-volume histograms in lesions and healthy parenchyma from different reconstructions were compared with those obtained from the reference biodistribution (the “gold standard,” GS), assessing differences for D95%, D70%, and D50% (i.e., minimum value of the absorbed dose to a percentage of the irradiated volume). γ tool analysis with tolerance of 3%/13 mm was used to evaluate the agreement between GS and simulated cases. The influence of deep-breathing was studied, blurring the reference biodistributions with a 3D anisotropic gaussian kernel, and performing the simulations once again. Results: Differences of the dosimetric indicators were noticeable in some cases, always negative for lesions and distributed around zero for parenchyma. Application of AC and SC reduced systematically the differences for lesions by 5%–14% for a liver segment, and by 7%–12% for a nonuniform liver. For parenchyma, the data trend was less clear, but the overall range of variability passed from −10%/40% for a liver segment, and −10%/20% for a nonuniform liver, to −13%/6% in both cases. Applying AC, SC with preset parameters gave similar results to optimized SC, as confirmed by γ tool analysis. Moreover, γ analysis confirmed that solely AC and SC are not sufficient to obtain accurate 3D dose distribution. With breathing, the accuracy worsened severely for all dosimetric indicators, above all for lesions: with AC and optimized SC, −38%/−13% in liver’s segment, −61%/−40% in the nonuniform liver. For parenchyma, D50% resulted always less sensitive to breathing and sub-optimal correction methods (difference overall range: −7%/13%). Conclusions: Reconstruction protocol optimization, AC, SC, PVE and respiratory motion corrections should be implemented to obtain the best possible dosimetric accuracy. On the other side, thanks to the relative calibration, D50% inaccuracy for the healthy parenchyma from absence of AC was less than expected, while the optimization of SC was scarcely influent. The relative calibration therefore allows to perform TARE planning, basing on D50% for the healthy parenchyma, even without AC or with suboptimal corrections, rather than rely on nondosimetric methods.

60 APPLIED LIFE SCIENCES↗

New Meteorlogical Data for Ventsar XL

Every five years Savannah River National Laboratory (SRNL) generates an updated meteorological database to facilitate dosimetric calculations of accident and routine release scenarios for onsite and offsite populations. This information becomes the input of various environmental dosimetry codes run by the Environmental Dosimetry Group (EDG) at SRNL. The three most recent databases prior to the current one were completed for the time periods 1987-1991, 1992-1996, and 1997-2001. The current database covers the period 2002-2006. This study represents a portion of a larger study to compare the meteorological data among these four five-year periods and focuses on updating VENTSAR XL{copyright} for the current meteorological database. The updated meteorological data are also applied in other dosimetry models approved for risk and dose assessment at Savannah River Site (SRS). VENTSAR XL{copyright} is a Gaussian Plume model that includes building effects and plume rise. The typical input involves the location of the release, building dimensions, distance to the building, release height, vent diameter, vent gas temperature, gas molecular weight, ambient air temperature, breathing rate, meteorological conditions, radionuclides and their amount released. The output is easily converted into tables and graphs for further analysis and shows the concentrations and pathway doses for each of the incremental downwind distances. VENTSAR XL{copyright} has been used at SRS to investigate building effects such as reactor cooling towers in support of safety analyses. VENTSAR XL{copyright} has also been applied to Good Engineering Practice (GEP) stack height evaluations for various projects at SRS. In accordance with the Clean Air Act Amendments of 1977, GEP must be used in determining the height of any stack that will be used to disperse routine emissions. With respect to stack heights, the GEP height is 'the height necessary to ensure that emissions from the stack do not result in excessive concentrations of any air pollutant in the immediate vicinity of the source as a result of atmospheric downwash, eddies and wakes which may be created by the source itself, nearby structures or nearby terrain obstacles.' The EPA has set specific criteria to determine if a stack is of the acceptable height. These criteria have been used to determine a GEP stack height for several emission assessments at SRS. The EPA documents contain detailed information on how the height of a stack is determined. The general rule for stack height determination is to make the stack at least 2 1/2 times the height of nearby buildings. This estimated height can be increased or decreased based on other factors such as plume rise, downwash, and building wake effects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sub-Sampled Imaging for STEM: Maximising Image Speed, Resolution and Precision Through Reconstruction Parameter Refinement

Sub-sampling during image acquisition in scanning transmission electron microscopy (STEM) has been shown to provide a means to increase the overall speed of acquisition while at the same time providing an efficient means to control the dose, dose rate and dose overlap delivered to the sample. In this paper, we discuss specifically the parameters used to reconstruct sub-sampled images and highlight their effect on inpainting using the beta-process factor analysis (BPFA) methodology. The selection of the main control parameters can have a significant effect on the resolution, precision and sensitivity of the final inpainted images, and here we demonstrate a method by which these parameters can be optimised for any image in STEM. As part of this paper, we also provide a link to open source code and a tutorial on its use, whereby these parameters can be tested for any datasets. When coupled with the hardware necessary to rapidly sub-sample images in STEM, this approach can have significant implications for imaging beam sensitive materials and dynamic processes.

47 OTHER INSTRUMENTATION↗

SU-E-T-608: Performance Comparison of Four Commercial Treatment Planning Systems Applied to Intensity-Modulated Radiotherapy

Purpose: To compare the performances of four commercial treatment planning systems (TPS) used for the intensity-modulated radiotherapy (IMRT). Methods: Ten patients of nasopharyngeal (4 cases), esophageal (3 cases) and cervical (3 cases) cancer were randomly selected from a 3-month IMRT plan pool at one radiotherapy center. For each patient, four IMRT plans were newly generated by using four commercial TPS (Corvus, Monaco, Pinnacle and Xio), and then verified with Matrixx (two-dimensional array/IBA Company) on Varian23EX accelerator. A pass rate (PR) calculated from the Gamma index by OminiPro IMRT 1.5 software was evaluated at four plan verification standards (1%/1mm, 2%/2mm, 3%/3mm, 4%/4mm and 5%/5mm) for each treatment plan. Overall and multiple pairwise comparisons of PRs were statistically conducted by analysis of covariance (ANOVA) F and LSD tests among four TPSs. Results: Overall significant (p>0.05) differences of PRs were found among four TPSs with F test values of 3.8 (p=0.02), 21.1(>0.01), 14.0 (>0.01), 8.3(>0.01) at standards of 1%/1mm to 4%/4mm respectively, except at 5%/5mm standard with 2.6 (p=0.06). All means (standard deviation) of PRs at 3%/3mm of 94.3 ± 3.3 (Corvus), 98.8 ± 0.8 (Monaco), 97.5± 1.7 (Pinnacle), 98.4 ± 1.0 (Xio) were above 90% and met clinical requirement. Multiple pairwise comparisons had not demonstrated a consistent low or high pattern on either TPS. Conclusion: Matrixx dose verification results show that the validation pass rates of Monaco and Xio plans are relatively higher than those of the other two; Pinnacle plan shows slight higher pass rate than Corvus plan; lowest pass rate was achieved by the Corvus plan among these four kinds of TPS.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP3-02: Benchmarks of a Proton Relative Biological Effectiveness (RBE) Model for DNA Double Strand Break (DSB) Induction in the FLUKA, MCNP, TOPAS, and RayStation™ Treatment Planning System

Purpose: Validate implementation of a published RBE model for DSB induction (RBEDSB) in several general purpose Monte Carlo (MC) code systems and the RayStation™ treatment planning system (TPS). For protons and other light ions, DSB induction is a critical initiating molecular event that correlates well with the RBE for cell survival. Methods: An efficient algorithm to incorporate information on proton and light ion RBEDSB from the independently tested Monte Carlo Damage Simulation (MCDS) has now been integrated into MCNP (Stewart et al. PMB 60, 8249–8274, 2015), FLUKA, TOPAS and a research build of the RayStation™ TPS. To cross-validate the RBEDSB model implementation LET distributions, depth-dose and lateral (dose and RBEDSB) profiles for monodirectional monoenergetic (100 to 200 MeV) protons incident on a water phantom are compared. The effects of recoil and secondary ion production ({sub 2}H{sub +}, {sub 3}H{sub +}, {sub 3}He{sub 2+}, {sub 4}He{sub 2+}), spot size (3 and 10 mm), and transport physics on beam profiles and RBEDSB are examined. Results: Depth-dose and RBEDSB profiles among all of the MC models are in excellent agreement using a 1 mm distance criterion (width of a voxel). For a 100 MeV proton beam (10 mm spot), RBEDSB = 1.2 ± 0.03 (− 2–3%) at the tip of the Bragg peak and increases to 1.59 ± 0.3 two mm distal to the Bragg peak. RBEDSB tends to decrease as the kinetic energy of the incident proton increases. Conclusion: The model for proton RBEDSB has been accurately implemented into FLUKA, MCNP, TOPAS and the RayStation™TPS. The transport of secondary light ions (Z > 1) has a significant impact on RBEDSB, especially distal to the Bragg peak, although light ions have a small effect on (dosexRBEDSB) profiles. The ability to incorporate spatial variations in proton RBE within a TPS creates new opportunities to individualize treatment plans and increase the therapeutic ratio. Dr. Erik Traneus is employed full-time as a Research Scientist at RaySearch Laboratories. The research build of the RayStation used in the study was made available to the University of Washington free of charge. RaySearch Laboratories did not provide any monetary support for the reported studies.

60 APPLIED LIFE SCIENCES↗

Molten Salt Reactor Experiment Simulation using Shift/Griffin

The Department of Energy (DOE)’s NEAMS focuses its efforts on the development of advanced modeling and simulation (M&S) tools for light-water reactors (LWRs) and non–LWRs (i.e., molten salt reactors, high-temperature gas reactors, microreactors, and fast reactors). In the previous fiscal year, the Multiphysics Applications Driver Technical Area funded molten salt reactor (MSR) M&S at Oak Ridge National Laboratory (ORNL) to generate multigroup macroscopic cross sections with Shift for a MSRE 2D lattice model in Griffin. In addition, Shift’s capability to calculate gamma dose rates from activated components in the primary exchangers in a molten salt breeder reactor was also demonstrated. In fiscal year 2023, ORNL generated multigroup macroscopic cross sections using Shift for a 3D MSRE core model. MSRE depletion calculations using Griffin were also demonstrated in this fiscal year. For the depletion calculation, one-group microscopic cross sections for the 3D MSRE core were generated using Shift, and the decay transmutation library from ORIGEN was converted to an ISOXML file, which is required as input in Griffin. Several Monte Carlo codes, such as OpenMC and Serpent, were also used to benchmark and supplement multigroup cross sections generated by Shift. Multigroup libraries were generated with 8 and 20 group structures, and the study found the 8-group structure to be more accurate when comparing Griffin results to continuous energy (CE) Monte Carlo results. The average flux from CE Shift calculations is up to ~6% higher than the CE Serpent calculations because of different values applied for the energy released per fission (κ values). The average flux in the fuel salt calculated by Griffin using cross sections generated with Shift agrees well with the reference CE Shift solution; the same is valid for the corresponding Serpent results. The maximum relative error is ~6% and ~2% compared to the CE Shift and Serpent reference solutions, respectively. Meanwhile, the average flux calculated by Griffin in the graphite moderator shows a higher difference in the thermal range when compared to both reference Monte Carlo solutions; this result suggests a need for improvement in cross section generation for the graphite moderator in the thermal range in both Monte Carlo codes. Griffin depletion calculations using cross sections from Shift and Serpent were performed and compared against ORIGEN calculations, and the nuclide densities calculated by Griffin were found to be generally in agreement with those of ORIGEN. Because a different approach was taken to calculate the energy released per fission ( κ values) in Shift and Serpent, a difference in nuclide densities from differences in the average flux was observed between Griffin using Serpent and Shift cross sections. Griffin calculations with Shift cross sections produced higher average flux in the salt than with Serpent cross sections, leading to higher consumption of 235 U and higher production of 135 Xe. For time-dependent depletion calculations, cross sections were generated with Serpent, and Griffin’s results using these cross sections were compared to CE Serpent depletion results, demonstrating good agreement. The average difference in keff between Serpent and Griffin as a function of burnup is about 155 pcm. Similarly, good agreement with small differences up to ~0.5% was also noticed in the nuclide density of 235 U and 135 Xe. More details regarding the methodologies invoked to generate the cross section to make code-to-code comparisons are discussed further in this report. User feedback on Griffin and Shift capabilities that will enhance these calculations is provided in this report for future consideration. The work performed this fiscal year can be extended further for multiphysics coupling of Griffin-Pronghorn/SAM with Mole to study precursor flow and salt chemistry.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-T-129: Impact of Radial Fluctuations in RBE for Therapeutic Proton Beams

Purpose: To evaluate the off axis relative biological effectiveness (RBE) for actively scanned proton beams and determine if a constant radial RBE can be assumed. Methods: The PHITS Monte Carlo code paired with a microscopic analytical function was used to determine probability distribution functions of the lineal energy in 0.3µm diameter spheres throughout a water phantom. Twenty million primary protons were simulated for a 0.6cm diameter pencil beam. Beam energies corresponding to Bragg Peak depths of 50, 100, 150, 200, 250, and 300mm were used and evaluated transversely every millimeter and radially for annuli of 1.0, 2.0, 3.0, 3.2, 3.4, 3.6, 4.0, 5.0, 10.0, 15.0, 20.0 and 25.0mm outer radius. The acquired probability distributions were reduced to dose-mean lineal energies and applied to the modified microdosimetric kinetic model, for human submandibular gland (HSG) cells, to calculate relative biological effectiveness (RBE) compared to 60Co beams at the 10% survival threshold. Results: RBE was generally seen to increase as distance from the central axis (CAX) increased. However, this increase was only seen in low dose regions and its overall effects on the transverse biological dose remains low. In the entrance region of the phantom (10mm depth), minimum and maximum calculated RBEs varied between 15.22 and 18.88% for different energies. At the Bragg peak, this difference ranged from 3.15 to 26.77%. Despite these rather large variations the dose-weighted RBE and the CAX RBE varied by less than 0.14% at 10mm depth and less than 0.16% at the Bragg peak. Similarly small variations were found at all depths proximal of the Bragg peak. Conclusion: Although proton RBE does vary radially, its overall effect on biological dose is minimal and the use of a radially constant RBE in treatment planning for scanned proton beams would not produce large errors.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP2-05: Feasibility Demonstration of High-Voltage Clinical CT and Impact On X-Ray Penetration Through Metal Objects

Purpose: To demonstrate the possibility and quantify the impact of operating a clinical CT scanner at exceptionally high x-ray tube voltage for better penetration through metal objects and facilitating metal artifact reduction. Methods: We categorize metal objects according to the data corruption severeness (level of distortion and complete photon starvation fraction). To demonstrate feasibility and investigate the impact of high voltage scanning we modified a commercial GE LightSpeed VCT scanner (generator and software) to enable CT scans with x-ray tube voltages as high as 175 kVp. A 20 cm diameter water phantom with two metal rods (10 mm stainless and 25 mm titanium) and a water phantom with realistic metal object (spine cage) were used to evaluate the data corruption and image artifacts in the absence of any algorithm correction. We also performed simulations to confirm our understanding of the transmitted photon levels through metal objects with different size and composition. Results: The reconstructed images at 175 kVp still have significant dark shading artifacts, as expected since no special scatter correction or beam hardening was performed but show substantially lower noise and photon starvation than at lower kVp due to better beam penetration. Analysis of the raw data shows that the photon starved data is reduced from over 4% at 140 kVp to below 0.2% at 175 kVp. The simulations indicate that for clinically relevant titanium and stainless objects a 175 kVp tube voltage effectively avoids photon starvation. Conclusion: The use of exceptionally high tube voltage on a clinical CT system is a practical and effective solution to avoid photon starvation caused by certain metal implants. Sparse and hybrid high-voltage protocols are being considered to maintain low patient dose. This opens the door to algorithmic physics-based corrections rather than treating the data as missing and relying on missing data algorithms. Some of the authors are employees of General Electric.

60 APPLIED LIFE SCIENCES↗