Calculation of Glycolate Concentration Factors Across the 242-25H (3H) Evaporator System
Two models were developed to predict glycolate concentration factors across the 242-25H (3H) Evaporator system. The first model, identified as the Unrestricted Evaporation Model, was designed to evaluate concentration of typical 3H feed material to relatively high densities in order to calculate the concentration factor of glycolate in a given feed stream. This model may be used to understand the potential of glycolate to concentrate from a generic feed material through the 3H system. The second model, identified as the Holistic Evaporation Model, was designed to evaluate the evaporation of dilute, glycolate-containing Defense Waste Processing Facility (DWPF) waste with the requirement that high silicon concentrations typical of recycle material require dilution to adhere to current technical safety requirements. This model may be used to understand the potential of glycolate from DWPF recycle material to concentrate as a result of feeding through the 3H system.