Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Effects of hydraulic fluid CVCM on silver-Teflon

Changes in the solar absorptance of silver-Teflon (Ag/FEP) surfaces were measured after contamination by the outgassing products of hydraulic fluid and irradiation by solar simulators. Although radiator surfaces are selected for stability to the solar ultraviolet and particulate environment, contaminant deposition and their interaction with solar exposure can degrade their performance. The test procedure to deposit the hydraulic fluid collected volatile condensible material (CVCM), irradiate, and determine solar absorptance changes by reflectance measurements using a spectrophotometer and a solar simulator is described. The tests showed that for the estimated deposition rates on the Ag/FEP, the hydraulic fluid CVCM fraction remaining under normal conditions (above -40 C) would not degrade its performance. The residual CVCM can be easily removed from Ag/FEP by wiping with a solvent saturated flannel. The changes in solar absorptance with the CVCM film thickness and the radiation exposure duration are reported, concluding that vacuum ultraviolet radiation did not prevent easy removal of CVCM.

Muscari, J. A.↗

Origin of longitudinal grooving in Tiu Vallis, Mars - Isolation of responsible fluid-types

Fluid instability analysis developed for the growth or decay of large, longitudinal roller vortex perturbations imposed at the base of fluids of exponentially stratified viscosities is presented. The origin of longitudinal grooving and fluting in a region of converging flow in Tiu Vallis, Mars, is analyzed, and the propensity of fluids, such as water, mudflow/debris flow, and lava, to develop longitudinal roll patterns as part of their flow field is tested. It is found that the grooving pattern in Tiu Vallis was probably formed by vortex motion in a mudflow or debris-laden slurry, but exact representation of sediment/debris concentration or sediment transport machanism is not yet possible. It is concluded that longitudinal vortex motion modelled in this analysis can develop in water, lava, or ice, but that the specific flow characteristics of these models which include the vortex motion are unreasonable for flow in Tiu Vallis.

Thompson, D. E.↗

Two-phase working fluids for the temperature range of 50 to 350 deg, phase 2

Several two phase heat transfer fluids were tested in aluminum and carbon steel reflux capsules for over 25,000 hours at temperatures up to 300 C. Several fluids showed very good stability and would be useful for long duration heat transfer applications over the range 100 to 350 C. Instrumentation for the measurement of surface tension and viscosity were constructed for use with heat transfer fluids over the temperature range 0 to 300 C and with pressures from 0 to 10 atmospheres. The surface tension measuring device constructed requires less than a 1.0 cc sample and displays an accuracy of about 5 percent in preliminary tests, while the viscometer constructed for this program requires a 0.05 cc sample and shows an accuracy of about 5 percent in initial tests.

Saaski, E. W.↗

Geophysical fluid flow experiment

The essential fluid flow processes associated with the solar and Jovian atmospheres will be examined in a laboratory experiment scheduled for performance on Spacelab Missions One and Three. The experimental instrumentation required to generate and to record convective fluid flow is described. Details of the optical system configuration, the lens design, and the optical coatings are described. Measurement of thermal gradient fields by schlieren techniques and measurement of fluid flow velocity fields by photochromic dye tracers is achieved with a common optical system which utilizes photographic film for data recording. Generation of the photochromic dye tracers is described, and data annotation of experimental parameters on the film record is discussed.

Broome, B. G.↗

Spectroscopic study of the effect on an EHD contact of trichloroethane addition to a traction fluid

Addition of trichloroethane to a traction fluid was studied in a ball/diamond plate EHD apparatus by infrared emission spectroscopy of the radiation transmitted through the plate. Small concentrations of an organic chloride at first increased infrared radiance, then decreased it. Large concentrations caused a rapid decrease. During running, the infrared spectrum showed an increase of aromatics and olefins. A polymeric deposit formed on the plate. X-ray examination of the ball surface showed the presence of chlorine. Reuse of the same ball with fresh fluid resulted in similar chain of events, indicating that adsorbed chloride could promote fluid deterioration.

Lauer, J. L.↗

Measurement of velocity fields in fluid dynamics experiments

A microcomputer-video system was used to measure both spatial and temporal variations of two dimensional fluid flow velocity fields. The system utilizes two methods: the first method is the traditional one in which tracers are introduced into the fluid and their position compared at two closely spaced times; and the second method involves scattering coherent light in the fluid and obtaining motion by analyzing the multiple exposed speckle pattern recorded on photographic film.

Fitzjarrald, D. E.↗

Formulation and evaluation of C-Ether fluids as lubricants useful to 260 C

Three base stocks were evaluated in bench and bearing tests to determine their suitability for use at bulk oil temperatures (BOT) from -40 C to +260 C. A polyol ester gave good bearing tests at a bulk temperature of 218 C, but only a partially successful run at 274 C. These results bracket the fluid's maximum operating temperature between these values. An extensive screening program selected lubrication additives for a C-ether (modified polyphenyl ether) base stock. One formulation lubricated a bearing for 111 hours at 274 C (BOT), but this fluid gave many deposit related problems. Other C-ether blends produced cage wear or fatigue failures. Studies of a third fluid, a C-ether/disiloxane blend, consisted of bench oxidation and lubrication tests. These showed that some additives react differently in the blend than in pure C-ethers.

Clark, F. S.↗

Micro-fluid exchange coupling apparatus

In a macro-fluid exchange, a hollow needle, such as a syringe needle, is provided for penetrating the fluid conduit of the animal. The syringe needle is coupled to a plenum chamber having an inlet and outlet port. The plenum chamber is coupled to the syringe needle via the intermediary of a standard quick disconnect coupling fitting. The plenum chamber is carried at the end of a drive rod which is coupled to a micrometer drive head. The micrometer drive head is slidably and pivotably coupled to a pedestal for adjusting the height and angle of inclination of the needle relative to a reference base support. The needle is positioned adjacent to the incised trachea or a blood vessel of a small animal and the micrometer drive head is operated for penetrating the fluid conduit of the animal.

Johnson, J. E., Jr.↗

Laser beam manifold and particle photography system for use in fluid velocity measurements

A laser beam manifold and particle photography system has been developed for use in fluid velocity measurements. The laser manifold is a device which transforms a single laser beam into several uniform parallel beams. By orienting two manifolds mutually perpendicular, an optical grid can be formed which acts as a reference for fluid velocity measurements. This optical grid is for all practical purposes totally nonperturbing to the flow. Tracer particles moving in the plane of the grid are then photographed to yield fluid velocities that can be measured relative to the optical grid. System construction and theory are presented.

Owen, R. B.↗

Effect of the fluid core on changes in the length of day due to long period tides

The long period luni-solar tidal potential is known to cause periodic changes in the earth's rotation rate. It is found that the effect of a dissipationless fluid outer core is to reduce the amplitudes of these tidal perturbations by about 11 percent. When the fluid core effect is added to Agnew and Farrell's (1978) estimate of the effect of an equilibrium ocean, the result is in accord with observation. The effects of dissipative processes within the fluid core are also examined. Out-of-phase perturbations are found which could be as large as about 10 ms at 18.6 yr. It is concluded, however, that the poorly understood decade fluctuations in the earth's rotation rate will prohibit observation of this effect.

Wahr, J. M.↗

Improved perfect-fluid energy-momentum tensor with spin in Einstein-Cartan space-time

The description of the spin given here is classical in that it is intrinsic but not quantized. The approach in this matter is similar to, for example, the work of Bailey and Israel (1973, 1975, 1979), where the fluid particles, which have intrinsic spin, may be galaxies or clusters of galaxies. The elementary particles of these objects and the 'ferromagnetic alignment' of their quantum spins are not resorted to in order to describe a fluid with spin. Physically this means that the equation of motion for the spin tensor is a modified Fermi-Walker transport equation (Misner et al., 1973), arising as a direct result of the inclusion of spin as an intrinsic variable in the thermodynamic description of the internal energy. The variables in this description are classical variables throughout and are not microscopic fields. An improved perfect-fluid energy-momentum tensor that includes spin and torsion is presented. Use is made of a Lagrangian variational principle based on the tetrad formalism of Halbwach (1960) and the method od constraints of Ray (1972).

Ray, J. R.↗

Measurement of interstage fluid-annulus dynamical properties

The work described in this paper is part of an Electric Power Research Institute sponsored effort to improve rotor vibrational performance on power plant feed water pumps. A major objective of this effort is to reduce vibration levels by devising inter-stage sealing configurations with optimized damping capacity, realizing that the typical multi-stage centrifugal pump has several ore inter-stage fluid annuli than it has journal bearings. Also, the fluid annuli are distributed between the journal bearings where vibration levels are highest and can therefore be 'exercised' more as dampers than can the bearings. Described in this paper is a test apparatus which has been built to experimentally determine fluid-annulus dynamical coefficients for various configurations of inter-stage sealing geometry.

Adams, M. L.↗

Assessment of critical-fluid extractions in the process industries

The potential for critical-fluid extraction as a separation process for improving the productive use of energy in the process industries is assessed. Critical-fluid extraction involves the use of fluids, normally gaseous at ambient conditions, as extraction solvents at temperatures and pressures around the critical point. Equilibrium and kinetic properties in this regime are very favorable for solvent applications, and generally allow major reductions in the energy requirements for separating and purifying chemical component of a mixture.

Source record↗

Non-Newtonian Fluid Model Incorporated into Elastohydrodynamic Lubrication of Rectangular Contacts

A procedure is outlined for the numerical solution of the complete elastohydrodynamic lubrication of rectangular contacts incorporating a non-Newtonian fluid model. The approach uses a Newtonian model as long as the shear stress is less than a limiting shear stress. If the shear stress exceeds the limiting value, the shear stress is set equal to the limiting value. The numerical solution requires the coupled solution of the pressure, film shape, and fluid rheology equations from the inlet to the outlet. Isothermal and no-side-leakage assumptions were imposed in the analysis. The influence of dimensionless speed, load, materials, and sliding velocity and limiting-shear-strength proportionality constant on dimensionless minimum film thickness was investigated. Fourteen cases were used in obtaining the minimum-film-thickness equation for an elastohydrodynamically lubricated rectangular contact incorporating a non-Newtonian fluid model. Computer plots are also presented that indicate in detail pressure distribution, film shape, shear stress at the surfaces, and flow throughout the conjunction.

Jacobson, B. O.↗

Fluid signatures of rotational discontinuities at Earth's magnetopause

Fluid signatures in the MHD approximation at rotational discontinuities (RD) of finite width called rotational shear layers (RSL) are examined for general flow and magnetic geometries. Analytical and geometrical arguments illustrate that the fluid speed can either go up or down across an RSL for a fixed normal mass flux. The speed profile may or may not be monotonic depending on the boundary conditions. The flow velocity may or may not be field aligned or ""jetting'' as a result of traversing the RSL. In general, significant ""convection'' is expected in the layer. The observable signatures of (MHD) RSL's depend on 7 (boundary condition) parameters are (1) the mass density, (2 to 5) the incident normal and transverse components of the magnetic field and fluid velocity, (6) the angle epsilon between the incident tangential flow velocity and tangential magnetic field, and (7) the size of the magnetic angular rotation implemented by the layer delta phi.

Scudder, J. D.↗

The rapid dissipation of magnetic fields in highly conducting fluids

The dynamical conditions that exist when long straight parallel twisted flux tubes in a highly conducting fluid are packed together in a broad array are treated. It is shown that in general there is no hydrostatic equilibrium. In place of equilibrium, there is a dynamical nonequilibrium, which leads to neutral point reconnection and progressive coalescence of neighboring tubes (with the same sense of twisting); this in turn forms tubes of large diameter and reduced twist. The magnetic energy in the twisting of each tube declines toward zero, being dissipated into small-scale motions of the fluid and thence into heat. Referring to the sun, it is pointed out that the twisting and mutual wrapping is converted directly into fluid motion and heat by the dynamical nonequilibrium, so that the work done by the convection of the footpoints goes directly into heating the corona above.

Parker, E. N.↗

Spinning fluids in general relativity

General relativity field equations are employed to examine a continuous medium with internal spin. A variational principle formerly applied in the special relativity case is extended to the general relativity case, using a tetrad to express the spin density and the four-velocity of the fluid. An energy-momentum tensor is subsequently defined for a spinning fluid. The equations of motion of the fluid are suggested to be useful in analytical studies of galaxies, for anisotropic Bianchi universes, and for turbulent eddies.

Ray, J. R.↗

Fluid shifts in vascular and extravascular compartments of humans during and after simulated weightlessness

A study is presented of the transcapillary pressures and the possible fluid shifts in muscles and subcutaneous tissue of the lower leg before, during, and after head-down tilt. Results showed that the subjects experienced facial edema, headache, nasal congestion, diuresis, and decreased lower-leg volume in response to 8 hours of 5 degree head-down tilt. Also found were significant decreases in systolic and diastolic pressures 2 hours after initiation of tilt, although blood pressure normalized thereafter. The lower-leg volume, urine output and interstitial fluid pressures of the tibialis anterior muscle and overlying subcutaneous tissue also changed significantly. No significant change was found in the colloid osmotic pressures of blood or interstitial fluid. It is concluded that these results indicate the need for countermeasures to maintain precapillary-muscle tone during long space flights in order to prevent swelling of lower-leg tissues upon readjustment to earth's gravity.

Hargens, A. R.↗