Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Accurate and Data‐Efficient Micro X‐ray Diffraction Phase Identification Using Multitask Learning: Application to Hydrothermal Fluids

Traditional analysis of highly distorted micro X‐ray diffraction (μ‐XRD) patterns from hydrothermal fluid environments is a time‐consuming process, often requiring substantial data preprocessing and labeled experimental data. Herein, the potential of deep learning with a multitask learning (MTL) architecture to overcome these limitations is demonstrated. MTL models are trained to identify phase information in μ‐XRD patterns, minimizing the need for labeled experimental data and masking preprocessing steps. Notably, MTL models show superior accuracy compared to binary classification convolutional neural networks. Additionally, introducing a tailored cross‐entropy loss function improves MTL model performance. Most significantly, MTL models tuned to analyze raw and unmasked XRD patterns achieve close performance to models analyzing preprocessed data, with minimal accuracy differences. This work indicates that advanced deep learning architectures like MTL can automate arduous data handling tasks, streamline the analysis of distorted XRD patterns, and reduce the reliance on labor‐intensive experimental datasets.

97 MATHEMATICS AND COMPUTING↗

Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet-printed CNT Electrodes-droplet Based Paracetamol Detection in Biological Fluids for “Point-of-care” Applications

A disposable acetaminophen biosensor based on inkjet-printed CNT electrodes (IJPCNT) modified with amidase/cerium dioxide@graphene nanoribbons composite was developed (ACeO2@GNR/IJPCNT). The enzyme amidase A was used for the first time as a recognition element. Inkjet-printed CNT electrodes served as a basis for the construction of a biosensor that enables droplet detection using 5 μL sample volume. The biosensor showed high selectivity, sensitivity, a low detection limit of 0.18 μM and a wide working linear range from 1 to 100 μM. The proposed approach allows fast and reliable detection of acetaminophen in biological fluids with negligible matrix effect and remarkable reproducibility. © 2019 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of individual mouse cerebrospinal fluid proteomes

Analysis of cerebrospinal fluid (CSF) offers key insight into the status of the central nervous system. Characterization of murine CSF proteomes can provide a valuable resource for studying central nervous system injury and disease in animal models. However, the small volume of CSF in mice has thus far limited individual mouse proteome characterization. Through non-terminal CSF extractions in C57Bl/6 mice and high-resolution liquid chromatography-mass spectrometry analysis of individual murine samples, we report the most comprehensive proteome characterization of individual murine CSF to date. Utilizing stringent protein inclusion criteria that required the identification of at least two unique peptides (1% false discovery rate at the peptide level) we identified a total of 566 unique proteins, including 128 proteins from three individual CSF samples that have been previously identified in brain tissue. Our methods and analysis provide a mechanism for individual murine CSF proteome analysis.

Cerebrospinal fluid↗

Speculation on measurements of the viscosity of shocked fluid water

Different reports of the viscosities of shocked water, relying on measurements of ionic drift speeds in dilute aqueous solution, of propagation of corrugations impressed on the shock front, and of the acceleration of entrained cylinders, disagree by six orders of magnitude across overlapping ranges of shock pressure. Measurements made at static pressures have proven that viscosities vary little along the Hugoniot, verifying the results from ionic drift speed. Why the other two proceedures yield such different results has been a matter of speculation. Here, I show reason to believe that the trajectories of the entrained cylinders were in a region of drag in which viscosities of 0.001 Pa-s and 1 Pa-s were experimentally indistinguishable, resulting in much larger supposed viscosities than warranted by the data. It follows that damping of corrugations are best explained as due to dissipative processes distinct from the shear viscosity of the equilibrated fluid.

36 MATERIALS SCIENCE↗

Microscale depletion of high abundance proteins in human biofluids using IgY14 immunoaffinity resin: Analysis of human plasma and cerebrospinal fluid

Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 µL) due to low yields stemming from losses caused by nonspecific binding to the column matrix. Additionally, the cost of the depletion media can be prohibitive for larger scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large scale studies. We characterized the performance of a 346 µL column volume micro-scale depletion system, using four different flow rates to determine the most effective depletion conditions for ~6 μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10 mL depletion column served as the control. Results showed depletion efficiency of the micro-scale column increased as flow rate decreased, and that our micro-depletion was reproducible. We found, in an initial application, a 600 µL sample of human cerebral spinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.

59 BASIC BIOLOGICAL SCIENCES↗

Remarks on Hierarchic Control for a Linearized Micropolar Fluids System in Moving Domains

We study a Stackelberg strategy subject to the evolutionary linearized micropolar fluids equations in domains with moving boundaries, considering a Nash multi-objective equilibrium (non necessarily cooperative) for the “follower players” (as is called in the economy field) and an optimal problem for the leader player with approximate controllability objective. We will obtain the following main results: the existence and uniqueness of Nash equilibrium and its characterization, the approximate controllability of the linearized micropolar system with respect to the leader control and the existence and uniqueness of the Stackelberg–Nash problem, where the optimality system for the leader is given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Potential of Computational Fluid Dynamics Simulation on Serial Monitoring of Hemodynamic Change in Type B Aortic Dissection

PurposeWe aimed to assess the potential of computational fluid dynamics simulation (CFD) in detecting changes in pressure and flow velocity in response to morphological changes in type B aortic dissection.Materials and MethodsPressure and velocity in four morphological models of type B aortic dissection before and after closure of the entry tear were calculated with CFD and analyzed for changes among the different scenarios. The control model (Model 1) was patient specific and built from the DICOM data of CTA, which bore one entry tear and three re-entry tears. Models 2–4 were modifications of Model 1, with two re-entry tears less in Model 2, one re-entry tear more in Model 3, and a larger entry tear in Model 4.ResultsThe pressure and velocity pertaining to each of the morphological models were unique. Changes in pressure and velocity findings were accountable by the changes in morphological features of the different models. There was no blood flow in the false lumen across the entry tear after its closure, the blood flow direction across the re-entry tears was reversed after closure of the entry tear.ConclusionCFD simulation is probably useful to detect hemodynamic changes in the true and false lumens of type B aortic dissection in response to morphological changes, it may potentially be developed into a non-invasive and patient-specific tool for serial monitoring of hemodynamic changes of type B aortic dissection before and after treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fluid–Structure Interaction Analysis of Papillary Muscle Forces Using a Comprehensive Mitral Valve Model with 3D Chordal Structure

Numerical models of native heart valves are being used to study valve biomechanics to aid design and development of repair procedures and replacement devices. These models have evolved from simple two-dimensional approximations to complex three-dimensional, fully coupled fluid-structure interaction (FSI) systems. Such simulations are useful for predicting the mechanical and hemodynamic loading on implanted valve devices. A current challenge for improving the accuracy of these predictions is choosing and implementing modeling boundary conditions. In order to address this challenge, we are utilizing an advanced in-vitro system to validate FSI conditions for the mitral valve system. Explanted ovine mitral valves were mounted in an in vitro setup, and structural data for the mitral valve was acquired with *CT. Experimental data from the in-vitro ovine mitral valve system were used to validate the computational model. As the valve closes, the hemodynamic data, high speed lea et dynamics, and force vectors from the in-vitro system were compared to the results of the FSI simulation computational model. The total force of 2.6 N per papillary muscle is matched by the computational model. In vitro and in vivo force measurements are important in validating and adjusting material parameters in computational models. The simulations can then be used to answer questions that are otherwise not possible to investigate experimentally. This work is important to maximize the validity of computational models of not just the mitral valve, but any biomechanical aspect using computational simulation in designing medical devices.

Comprehensive Computational Model↗

One-Dimensional Fluids with Second Nearest–Neighbor Interactions

As is well known, one-dimensional systems with interactions restricted to first nearest neighbors admit a full analytically exact statistical-mechanical solution. This is essentially due to the fact that the knowledge of the first nearest–neighbor probability distribution function, p{sub 1}(r), is enough to determine the structural and thermodynamic properties of the system. On the other hand, if the interaction between second nearest–neighbor particles is turned on, the analytically exact solution is lost. Not only the knowledge of p{sub 1}(r) is not sufficient anymore, but even its determination becomes a complex many-body problem. In this work we systematically explore different approximate solutions for one-dimensional second nearest–neighbor fluid models. We apply those approximations to the square-well and the attractive two-step pair potentials and compare them with Monte Carlo simulations, finding an excellent agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The separation of lanthanides and actinides in supercritical fluid carbon dioxide

Supercritical fluid carbon dioxide presents an attractive alternative to conventional solvents for recovery of the actinides and lanthanides. Carbon dioxide is a good solvent for fluorine and phosphate-containing ligands, including the traditional tributylphosphate ligand used in process-scale uranium separations. Actinide and lanthanide oxides may even be directly dissolved in carbon dioxide containing the complexes formed between these ligands and mineral acids, obviating the need for large volumes of acids for leaching and dissolution, and the corresponding organic liquid–liquid solvent extraction solutions. As a result, examples of the application of this novel technology for actinide and lanthanide separations are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitive parameter identification and uncertainty quantification for the stability of pipeline conveying fluid

In this study, several uncertainty quantification and sensitivity analysis methods are used to determine the most sensitive geometric and material input parameters of a cantilevered pipeline conveying fluid when uncertainty is introduced to the system at the onset of instability. The full nonlinear equations of motion are modeled using the extended Hamilton’s principle and then discretized using Galerkin’s method. A parametric study is first performed, and the Morris elementary effects are calculated to obtain a preliminary understanding of how the onset speed changes when each parameter is introduced to a ± 5% uncertainty. Then, four different input uncertainty distributions, mainly, uniform and Gaussian distribution, are chosen to investigate how input distributions affect uncertainty in the output. A convergence analysis is used to determine the number of samples needed to maintain simulation accuracy while saving the most computational time. Then, Monte Carlo simulations are run, and the output distributions for each input distribution at ± 1%, ± 3% and ± 5% input uncertainty range are found and discussed. Additionally, the Pearson correlation coefficients are evaluated for different uncertainty ranges. A final Monte Carlo study is performed in which single parameters are held constant while all others still have uncertainty. Overall, the flow speed at the onset of instability is the most sensitive to changes in the outer diameter of the pipe.

36 MATERIALS SCIENCE↗

Consequences and benefits of utilizing continuous vibro-impact representations in constrained pipeline conveying fluid systems

Here, the effectiveness of continuous vibro-impact forcing representations for the cantilevered pipe that conveys fluid is explored and analyzed. The previously accepted forcing model utilizing a smoothened trilinear spring is estimated using three continuous forcing representations, namely, polynomial, rational polynomial, and hyperbolic tangent. The accuracy of the estimated forcing functions is investigated and analyzed by calculating the root mean square error, and bifurcation diagrams are generated and compared to the nominal system. Additionally, the dynamic response of the system is further characterized using Poincare maps, power spectra, and basins of attraction. Once all continuous forcing representations are analyzed and compared to the nominal system, the computational cost of each method is examined, and further limitations of the hyperbolic tangent method are discovered. It is proved that the hyperbolic tangent forcing representation most accurately captures the dynamic response of the pipeline, and the least accurate representation is the rational polynomial representation. Additionally, considerable computational cost is saved when employing the hyperbolic tangent representation compared to the discontinuous representation.

42 ENGINEERING↗

Metastable Fluid Decay During Electric Explosion of Metallic Foils

Results of experimental investigations into overheated metastable fluid decay during electric explosion of metallic foils are presented. Experiments have been performed using an experimental complex consisting of three current generators, one of which provides explosion of foil and two others – X-pinch-based radiographs – are used for diagnostic purposes. The upper limit of the decay time of an overheated metastable metal is determined experimentally. For aluminum conductor with deposited energy of (5.3 ± 0.5) kJ/g, the metastable state decay time is ~110 ns; for copper foil with deposited energy of (2.4 ± 0.2) kJ/g, it is ~260 ns; and for nickel foil with deposited energy of (1.3 ± 0.3) kJ/g, it is ~350 ns.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Approach to Cerebrospinal Fluid (CSF) Biomarker Discovery and Evaluation in HIV Infection

Central nervous system (CNS) infection is a nearly universal facet of systemic HIV infection that varies in character and neurological consequences. While clinical staging and neuropsychological test performance have been helpful in evaluating patients, cerebrospinal fluid (CSF) biomarkers present a valuable and objective approach to more accurate diagnosis, assessment of treatment effects and understanding of evolving pathobiology. We review some lessons from our recent experience with CSF biomarker studies. We have used two approaches to biomarker analysis: targeted, hypothesis-driven and non-targeted exploratory discovery methods. We illustrate the first with data from a cross-sectional study of defined subject groups across the spectrum of systemic and CNS disease progression and the second with a longitudinal study of the CSF proteome in subjects initiating antiretroviral treatment. Both approaches can be useful and, indeed, complementary. The first is helpful in assessing known or hypothesized biomarkers while the second can identify novel biomarkers and point to broad interactions in pathogenesis. Common to both is the need for well-defined samples and subjects that span a spectrum of biological activity and biomarker concentrations. Previouslydefined guide biomarkers of CNS infection, inflammation and neural injury are useful in categorizing samples for analysis and providing critical biological context for biomarker discovery studies. CSF biomarkers represent an underutilized but valuable approach to understanding the interactions of HIV and the CNS and to more objective diagnosis and assessment of disease activity. Both hypothesis-based and discovery methods can be useful in advancing the definition and use of these biomarkers.

Biomarkers↗

Effects of Heat Treatment on Corrosion and Wear Behaviors of Mg-6Gd-2Zn-0.4Zr Alloy in Simulated Body Fluid

Mg-6Gd-2Zn-0.4Zr (wt.%, GZ62K) alloy was processed by solution treatment under different temperatures. The microstructure, hardness, corrosion and wear behaviors in simulated body fluid (SBF) have been studied. The results indicate that the (Mg, Zn){sub 3}Gd phase decreases, the precipitated phases gradually increase, and the long-period stacking ordered structure disappears with the increase of solution temperature. The alloy has better corrosion resistance after solution treatment, and that solution treated at 490 °C for 12 h shows the best corrosion resistance. The friction coefficient of the alloy under dry sliding condition decreases slightly, but the mass loss increases with increasing the solution temperature. The alloy solution treated at 460 °C for 12 h exhibits the lowest friction coefficient and mass loss in SBF, and it also has the best wear resistance under dry sliding condition.

36 MATERIALS SCIENCE↗

Electrochemical Corrosion and In vitro Biocompatibility Performance of AZ31Mg/Al{sub 2}O{sub 3} Nanocomposite in Simulated Body Fluid

In this present investigation, AZ31 alloy nanocomposite was prepared with the inclusion of Al{sub 2}O{sub 3} nanoparticles using innovative disintegrated melt deposition (DMD) process followed by hot extrusion to improve the corrosion resistance and in vitro biocompatibility in simulated body fluid (SBF). This investigation systematically inspected the degradation performances of AZ31 alloy with Al{sub 2}O{sub 3} nanoparticles through hydrogen evolution, weight loss and electrochemical methods in SBF. Further, the surface microstructure with the in vitro mineralization of the alloys in SBF was characterized by XRD, XPS, and SEM/EDS analysis. It was seen that the addition of Al{sub 2}O{sub 3} nanoparticles significantly decreased the weight loss of AZ31 alloy substrates after 336 h of exposure in SBF. The corrosion resistance of the monolithic and nanocomposite samples was evaluated using potentiodynamic polarization tests, electrochemical impedance spectroscopy measurements in short- and long-term periods. Accordingly, the electrochemical analysis in SBF showed that the corrosion resistance performance of the AZ31 alloy enhanced considerably due to the incorporation of Al{sub 2}O{sub 3} nanoparticles as reinforcement. Moreover, the rapid formation of bone-like apatite layer on the surface of the nanocomposite substrate demonstrated a good bioactivity of the nanocomposite samples in SBF.

77 NANOSCIENCE AND NANOTECHNOLOGY↗