Novel highly ordered core–shell nanoparticles
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Streambed sediment physical properties such as surface area, are difficult to quantify in situ but exert a high-level control on a wide range of biogeochemical processes and sorption of contaminants. We introduce the use of complex electrical conductivity (CC) methods (also known as spectral-induced polarization (SIP)) that measure both real and imaginary conductivity to noninvasively and efficiently characterize shallow streambed sediments. We explore the method through synthetic modeling, laboratory, and field measurements to demonstrate the sensitivity of imaginary conductivity to sediment surface area, controlled in part by fine-grained iron oxides produced by anoxic groundwater discharge. Laboratory measurements verify expected relationships between CC parameters and sediment properties. Synthetic modeling using a 1D analytical model illustrates the influence of water layer depth and conductivity on the field CC measurements made at the streambed-stream water interface. Specifically, the inverted sediment imaginary conductivity is less impacted by uncertainty in the water layer depth and conductivity relative to the real conductivity and phase shift. Field CC measurements along a landfill-impacted river reveal discrete streambed zones with enhanced bulk surface area generally corresponding to anoxic groundwater discharge zones with high concentrations of fine-grained iron oxide precipitates.
Explore the source record for details and available documents.
The electric grid is in the beginning stage of a transformation, driven by a combination of shutdowns of coal-fired plants, commissioning of new natural-gas plants, and tremendous growth in energy supply from renewables such as wind, and solar. As utilities navigate this transformation, their progress is supported by advances in Operational Technologies (OT), and Informational Technologies (IT), such as automation, smart inverters, cloud computing, mobile computing, machine learning, big data analytics, which have the potential to enable advanced capabilities more efficiently and at a lower cost. This white paper focuses on the architectural considerations that will allow the industry to transition in a planned manner. It introduces and formalizes two architectural constructs –the data bus and the control bus. The data bus is responsible for carrying all non-operational models and information necessary to drive utility decisions. In contrast, the control bus is responsible for carrying all operational data and control actions taken at the local level, centralized level, or other levels in-between. The paper reviews those architectural considerations, their requirements and how they will evolve. This paper intends to provide a context for vendors, utilities, and their service providers to review and understand the changes that are coming and get ready for them.
Some of the more important developments and progress in jet and fan noise reduction and flight effects are reviewed. Experiments are reported which show that nonaxisymmetric coannular nozzles have the potential to reduce jet noise for conventional and inverted velocity profiles. It is shown that an improved understanding of suppressive linear behavior, coupled with the new understanding of fan source noise, will soon allow the joint optimization of acoustic liner and fan design for low noise. It is also shown that fan noise source reduction concepts are applicable to advanced turboprops. Advances in inflow control device design are reviewed that appear to offer an adequate approach to the ground simulation of inflight fan noise.
As the penetration level of power electronics-interfaced renewables such as photovoltaics (PV) and wind has surged in modern electric grids, new operational risks caused by the dynamics of those inverter-based resources (IBRs) are emerging in parallel. Lessons learned from various grid events include that the impact of IBRs on system-level grid stability will become prominent along with the increase of renewables and that the short-timescale dynamic impacts of IBRs on grid stability are not fully captured by current commercial dynamic simulation tools [1] [2]. For example, IBRs can be controlled to mitigate those destabilizing interactions, but conventional phasor-domain tools (e.g. PSS/E, PSLF) often cannot capture that; likewise, the existing electromagnetic transient (EMT) simulation tools (e.g. PSCAD, EMTP) can simulate detailed IBR controls, but for large power systems with many IBRs, slow simulation speeds severely impede the ability to study dynamic events [3] [4]. Massively paralleling simulations using high-performance computing (HPC) can help address this, especially now that cloud-based HPC capability is widely available, but today s EMT tools are not HPC-compatible, and parallelization of dynamic simulation solvers is not trivial because each region can dynamically affect the others. Thus, dynamic simulation of grids with very large numbers of IBRs potentially poses a barrier to the ongoing energy transition.
The frequency response of SG-dominated power grids is predictable ahead of an occurrence of a frequency event because the frequency response of SGs is consistent, and it can be inferred from the swing equation [1]. However, increasing the portion of IBRs in an SG-dominated power grid might make the characteristics of the conventional power grids no longer valid because this changing resource mix affects grid dynamics and controls [2]. Thus, maintaining these characteristics greatly benefits the control and operation of the power grids with high penetration of IBRs. To maintain these characteristics in IBR-dominated power grids, IBRs should have frequency response capability similar to that of an SG. The WECC modeling validation subcommittee has developed generic IBR models for large system planning [3]-[5]. These models can represent various vendors' dynamic behavior for WTG, PV, and ESS [5]. The current generic IBR models approved by WECC can provide frequency response only from droop control loops in REPC models [6], [7]. The contribution of the loops is proportional to the frequency deviation from the nominal frequency. Thus, it presents an insufficient contribution to arrest frequency variation compared to the frequency response of SGs because it allows a high ROCOF in the early stage of frequency events. This shortfall will become greater as the PL of IBRs increases in power grids. Controller enhancement for the generic IBR models is required to secure the frequency stability under high PL of IBRs as in the SG-dominated power grids. This paper proposes a control extension for the generic IBR models to enhance the frequency support capabilities and discusses the classification of frequency support for the different types of IBR considering their operating constraints. An inertial control scheme is implemented in the REPC and REEC models of the generic IBR models to achieve these objectives. The inertial control scheme includes the following stages: Control area data acquisition, inertia time constant estimation, IBR-related constraint check, IBR contribution determination, and inertial response provision. In the scheme, a REPC acquires control area data from a system operator and estimates a total inertia time constant for the control area the applicable IBR power plant belongs. Then, the estimated inertial time constant is transferred to each IBR controller—REEC—within the power plant. Each REEC checks the availability of applicable IBR for inertial response participation. If the IBR is available, the REEC amplifies the estimated inertial time constant to utilize it for inertial response provision. In this way, the proposed inertial response scheme extends the functionality of the generic IBR models to provide SG-like frequency response within their constraints. Various scenarios considering different IBR types, IBR penetration levels, and frequency control schemes were simulated and compared in an IEEE 39-bus system using PSCAD simulator to verify the effectiveness of the proposed scheme.
The power distribution system with its reliance on automated monitoring and control infrastructure makes it a complicated cyber-physical system and vulnerable to various cyber-attacks. This paper proposes a moving target defense inspired false data injection attack (FDIA) detection mechanism for an unbalanced distribution system. In the proposed grid diagnosis service framework, the distribution system operator judiciously manipulates power outputs of a subset of inverter-based distribution energy resources (DERs) to create secret low magnitude voltage perturbations which are inconsequential to the normal operation of the grid. A mixed-integer-linear-programming algorithm is developed to select the optimal set of DERs that can create a voltage perturbation signal of the required magnitude at each sensor location at a minimum cost. Then, a sequential detector is applied that detects for the FDIA as measurements are received from individual sensors. The performance of the proposed perturbation-based FDIA detection framework is demonstrated via simulation of the IEEE 123 bus test system.
A detailed simulation of a dc inductor resonant driver and receiver is used to demonstrate the transient characteristics of a 20 kHz resonant power system during fault and overload conditions. The simulated system consists of a dc inductor resonant inverter (driver), a 50-meter transmission cable, and a dc inductor resonant receiver load. Of particular interest are the driver and receiver performance during fault and overload conditions and on the recovery characteristics following removal of the fault. The information gained from these studies sets the stage for further work in fault identification and autonomous power system control.
Typical laboratory flames for the scientific investigation of flame/turbulence interactions are prone to buoyancy effects. Buoyancy acts on these open flame systems and provides upstream feedbacks that control the global flame properties as well as local turbulence/flame interactions. Consequently the flame structures, stabilization limits, and turbulent reaction rates are directly or indirectly coupled with buoyancy. The objective of this study is to characterize the differences between premixed turbulent flames pointing upwards (1g), pointing downwards (-1g), and in microgravity (mg). The configuration is an inverted conical flame stabilized by a small cone-shaped bluff body that we call CLEAN Flames (Cone-Stabilized Lean Flames). We use two laser diagnostics to capture the velocity and scalar fields. Particle image velocimetry (PIV) measures the mean and root mean square velocities and planar imaging by the flame fronts method outlines the flame wrinkle topology. The results were obtained under typical conditions of small domestic heating systems such as water heaters, ovens, and furnaces. Significant differences between the 1g and -1g flames point to the need for including buoyancy contributions in theoretical and numerical calculations. In Earth gravity, there is a complex coupling of buoyancy with the turbulent flow and heat release in the flame. An investigation of buoyancy-free flames in microgravity will provide the key to discern gravity contributions. Data obtained in microgravity flames will provide the benchmark for interpreting and analyzing 1g and -1g flame results.
All-dielectric metasurfaces have become a new paradigm for flat optics as they allow flexible engineering of the electromagnetic space of propagating waves. Such metasurfaces are usually composed of individual subwavelength elements embedded into a host medium or placed on a substrate, which often diminishes the quality of the resonances. The substrate imposes limitations on the metasurface functionalities, especially for infrared and terahertz frequencies. Here a novel concept of membrane Huygens' metasurfaces is introduced. The metasurfaces feature an inverted design, and they consist of arrays of holes made in a thin membrane of high-index dielectric material, with the response governed by the electric and magnetic Mie resonances excited within dielectric domains of the membrane. Highly efficient transmission combined with the 2π phase coverage in the freestanding membranes is demonstrated. Several functional metadevices for wavefront control are designed, including beam deflector, a lens, and an axicon. Lastly, such membrane metasurfaces provide novel opportunities for efficient large-area metadevices, whose advanced functionality is defined by structuring rather than by chemical composition.
Conservation voltage reduction (CVR) is implemented in the distribution system to reduce the voltage along the feeder with the objective to reduce the power consumption. Due to the increased penetration of distributed generators in the distribution system the centralized control is cumbersome. Hence, in this paper, a distributed algorithm is proposed for volt-var optimization (VVO) with CVR objective in a three-phase unbalanced distribution network. The proposed method is based on alternating direction method of multipliers (ADMM) algorithm. Mathematically the problem is formulated as a convex optimization problem with reactive power support from smart inverters. The convexity guarantees the solution obtained using the proposed method is a converged solution. The proposed method is validated on IEEE 4-bus and 13-bus three-phase unbalanced systems.
Renewable portfolio standards are targeting high levels of variable solar photovoltaics (PV) in electric distribution systems, which makes reliability more challenging to maintain for distribution system operators (DSOs). Distributed energy resources (DERs), including smart, connected appliances and PV inverters, represent responsive grid resources that can provide flexibility to support the DSO in actively managing their networks to facilitate reliability under extreme levels of solar PV. This flexibility can also be used to optimize system operations with respect to economic signals from wholesale energy and ancillary service markets. Here, we present a novel hierarchical scheme that actively controls behind-the-meter DERs to reliably manage each unbalanced distribution feeder and exploits the available flexibility to ensure reliable operation and economically optimizes the entire distribution network. Each layer of the scheme employs advanced optimization methods at different timescales to ensure that the system operates within both grid and device limits. The hierarchy is validated in a large-scale realistic simulation based on data from the industry. Simulation results show that coordination of flexibility improves both system reliability and economics, and enables greater penetration of solar PV. Discussion is also provided on the practical viability of the required communications and controls to implement the presented scheme within a large DSO.
Double-difference waveform inversion is a potential tool for quantitative monitoring for geologic carbon storage. It jointly inverts time-lapse seismic data for changes in reservoir geophysical properties. Due to the ill-posedness of waveform inversion, it is a great challenge to obtain reservoir changes accurately and efficiently, particularly when using time-lapse seismic reflection data. Regularization techniques can be utilized to address the issue of ill-posedness. The regularization parameter controls the smoothness of inversion results. A constant regularization parameter is normally used in waveform inversion, and an optimal regularization parameter has to be selected. The resulting inversion results are a trade off among regions with different smoothness or noise levels; therefore the images are either over regularized in some regions while under regularized in the others. In this paper, we employ a spatially-variant parameter in the Tikhonov regularization scheme used in double-difference waveform tomography to improve the inversion accuracy and robustness. We compare the results obtained using a spatially-variant parameter with those obtained using a constant regularization parameter and those produced without any regularization. We observe that, utilizing a spatially-variant regularization scheme, the target regions are well reconstructed while the noise is reduced in the other regions. We show that the spatially-variant regularization scheme provides the flexibility to regularize local regions based on the a priori information without increasing computational costs and the computer memory requirement.
A power circuit substantially canceling ripples at the source. The power circuit includes a switching circuit configured to control a power flow between an input and an output, a main storage element electrically connected in series with the switching circuit, and a resonant tank electrically coupled to the switching circuit and configured to compensate for switching ripples in the main storage element. Aspects of the invention can be applied to a converter circuit or to an inverter circuit.
Quantifying fast frequency response (FFR) of inverter-based resources (IBRs) is crucial for robust frequency regulation, managing resources, and improving system reliability in the power grids with high penetration levels of IBRs. This paper proposes a concept of frequency response scheme that its response is quantifiable and applicable to the generic IBR models. To achieve this, a stepwise-energy function is derived as a control module by considering operational constraints of IBRs. Then the module is implemented along with generic IBR models in electromagnetic transient (EMT) and electromechanical-based software. To quantify the FFR, the implemented module calculates available incremental active power for a specific time duration. This energy profile is being updated depending on IBR’s operating conditions and is provided into a power grid upon detecting a frequency event. Thus, due to this characteristic, this scheme can quantify the FFR and enable applicable IBRs to provide their available headroom within frequency arrest period. Thereby, this scheme can help estimate IBRs’ frequency response and is more effective in improving the initial frequency response than frequency-dependent control schemes: rate-of-change-of-frequency based and droop-based control schemes. The performance of the proposed scheme was tested under different IBR penetration levels using PSLF and PSCAD simulators.
Medium-voltage DC (MVDC) grids are attractive for electric aircraft and ship power systems, battery energy storage system (BESS), fast charging electric vehicle (EV), etc. Such EV or BESS applications need isolated bidirectional MVDC to LVDC or LVAC converters. However, the existing Si-based solutions cannot fulfill the requirements of a high-efficiency and robust converter for MVDC grids. This paper presents a 5 kV SiC-based universal modular solid-state transformer (SST). This universal current-source SST can interface either a LVAC or LVDC grid with a MVDC grid in single-stage power conversion, while the conventional dual active bridge (DAB) converter needs an additional inverter. The proposed SST module using 3.3 kV SiC MOSFETs and diodes is bidirectional and can serve as a building block in series or parallel for higher-voltage higher-power systems. The topology of each module is based on the soft-switching solid-state transformer (S4T) with reduced conduction loss, which features reduced EMI through controlled dv/dt, and high efficiency with full-range ZVS for main devices and ZCS for auxiliary devices. Operation principle of the modular S4T (M-S4T), capacitor voltage balancing control between the cascaded modules, design of components including a medium-voltage (MV) medium-frequency transformer (MFT) to realize a 50 kVA 5 kV DC to 600 V DC or 480 V AC M-S4T are presented. Importantly, the MV MFT prototype achieves very low leakage inductance (0.13%) and 15 kV insulation with coaxial cables and nanocrystalline cores. Here, the proposed universal modular SST is compared against the DAB solution and verified with DC-DC and DC-AC simulation and 4 kV experimental results. Significantly, the MV experimental results of a modular DC transformer with each module at MVDC are rarely covered in the literature and reported for the first time.
The Rhodopseudomonas palustris transcriptional regulator RpaR responds to the RpaI-synthesized quorum-sensing signal p-coumaroyl-homoserine lactone (pC-HSL). Other characterized RpaR homologs respond to fatty acyl-HSLs. We show here that RpaR functions as a transcriptional activator, which binds directly to the rpaI promoter. We developed an RNAseq method that does not require a ribosome depletion step to define a set of transcripts regulated by pC-HSL and RpaR. The transcripts include several noncoding RNAs. A footprint analysis showed that purified His-tagged RpaR (His6-RpaR) binds to an inverted repeat element centered 48.5 bp upstream of the rpaI transcript start site, which we mapped by S1 nuclease protection and primer extension analyses. Although pC-HSL-RpaR bound to rpaI promoter DNA, it did not bind to the promoter regions of a number of RpaR-regulated genes not in the rpaI operon. This indicates that RpaR control of these other genes is indirect. Because the RNAseq analysis allowed us to track transcript strand specificity, we discovered that there is pC-HSL-RpaR-activated antisense transcription of rpaR. These data raise the possibility that this antisense RNA or other RpaR-activated noncoding RNAs mediate the indirect activation of genes in the RpaR-controlled regulon.