Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Point Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Effective defect diffusion lengths in Ar-ion bombarded 3C-SiC

Above room temperature, SiC exhibits pronounced processes of diffusion and interaction of radiation-generated point defects. Here, we use the recently developed pulsed ion beam method to measure effective defect diffusion lengths in 3C-SiC bombarded in the temperature range of 25–200 °C with 500 keV Ar ions. Results reveal a diffusion length of ~10 nm, which exhibits a weak temperature dependence, changing from 9 to 13 nm with increasing temperature. Lastly, these results have important implications for understanding and predicting radiation damage in SiC and for the development of radiation-resistant materials via interface-mediated defect reactions.

36 MATERIALS SCIENCE↗

Ab initio ultrafast spin dynamics in solids

Spin relaxation and decoherence is at the heart of spintronics and spin-based quantum information science. Currently, theoretical approaches that can accurately predict spin relaxation of general solids including necessary scattering pathways and are capable of nanosecond to millisecond simulation time are urgently needed. We present a first-principles real-time density-matrix approach based on Lindblad dynamics to simulate ultrafast spin dynamics for general solid-state systems. Through the complete first-principles descriptions of pump, probe, and scattering processes including electron-phonon, electron-impurity, and electron-electron scatterings with self-consistent electronic spin-orbit couplings, our method can directly simulate the ultrafast pump-probe measurements for coupled spin and electron dynamics over nanoseconds at any temperatures and doping levels. We first apply this method to a prototypical system GaAs and obtain excellent agreement with experiments. We found that the relative contributions of different scattering mechanisms and phonon modes differ considerably between spin and carrier relaxation processes. In sharp contrast to previous work based on model Hamiltonians, we point out that the electron-electron scattering is negligible at room temperature but becomes dominant at low temperatures for spin relaxation in n-type GaAs. We further examine ultrafast dynamics in novel spin-valleytronic materials: monolayer and bilayer WSe 2 with realistic defects. We find that spin relaxation is highly sensitive to local symmetry and chemical bonds around defects. For the bilayer WSe 2 , we identify the scattering pathways in ultrafast dynamics and determine relevant dynamical properties, essential to its utilization of unique spin-valley-layer locking effects. In conclusion, our work provides a predictive computational platform for spin dynamics in solids, which has potential for designing new materials ideal for spintronics and quantum information technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Topological Exact Flat Bands in Two-Dimensional Materials under Periodic Strain

Here we study flat bands and their topology in 2D materials with quadratic band crossing points under periodic strain. In contrast to Dirac points in graphene, where strain acts as a vector potential, strain for quadratic band crossing points serves as a director potential with angular momentum . We prove that when the strengths of the strain fields hit certain “magic” values, exact flat bands with emerge at charge neutrality point in the chiral limit, in strong analogy to magic angle twisted-bilayer graphene. These flat bands have ideal quantum geometry for the realization of fractional Chern insulators, and they are always fragile topological. The number of flat bands can be doubled for certain point group, and the interacting Hamiltonian is exactly solvable at integer fillings. We further demonstrate the stability of these flat bands against deviations from the chiral limit, and discuss possible realization in 2D materials.

36 MATERIALS SCIENCE↗

Optical properties of Mo and amorphous MoOx, and application to antireflection coatings for metals

To form antireflection (AR) coatings to hide metal architecture in display technologies, we deposited thin films of metal Mo and oxide MoOx by sputtering targets of various compositions using pure Ar sputter gas. The optical constants [n,k] of these samples were measured by the direct numerical solution of reflectance and transmittance at each wavelength point measured. We find that 50 nm films are uniform in the growth direction, but for thicker 100 nm samples, evidence exists for nonuniform growth, where the top 20 nm appears to be metal rich. From these [n,k], negative Tauc bandgap energies show these oxides are semi-metals. We then identified the specific composition (x) that optimizes the AR response for a host of metals (Al, Cu, Ag, Au). Finally, two methods were used to understand why these MoOx materials function well as AR media, including (i) using phasor rays and (ii) developing a universal expression for the AR condition that applies to both dielectric and metal substrates. In (i), we find two characteristics for AR of metals: (a) its optical thickness should be roughly π3, not the π2 for dielectrics, since for MoOx, their [r^ij,t^ij] Fresnel phases differ from the usual [180°, 0°] of dielectrics; and (b) the medium incorporates a k-dominant strategy whose function is to absorb the energy that is reflected at the AR/metal interface. In (ii), the universal AR condition is found to be r^01+r^12z^=0. For dielectrics, this reduces to the well-known nAR=nairnsub condition. However, for metals, a concise analytic expression is lacking since this expression is highly nonlinear but is easily solved by numerical methods.

Tsu, David V. (ORCID:0000000295903418)↗

In vivo dosimetry with optically stimulated luminescent dosimeters, OSLDs, compared to diodes; the effects of buildup cap thickness and fabrication material

Purpose: For external beam in vivo measurements, the dosimeter is normally placed on the patient's skin, and the dose to a point of interest inside the patient is derived from surface measurements. In order to obtain accurate and reliable measurements, which correlate with the dose values predicted by a treatment planning system, a dosimeter needs to be at a point of electronic equilibrium. This equilibrium is accomplished by adding material (buildup) above the detector. This paper examines the use of buildup caps in a clinical setting for two common detector types: OSLDs and diodes. Clinically built buildup-caps and commercially available hemispherical caps are investigated. The effects of buildup cap thickness and fabrication material on field-size correction factors, C{sub FS}, are reported, and differences between the effects of thickness and fabrication material are explained based on physical parameters. Methods: Measurements are made on solid water phantoms for 6 and 15 MV x-ray beams. Two types of dosimeters are used: OSLDs, InLight/OSL Nanodot dosimeters (Landauer, Inc., Glenwood, IL) and a P-type surface diode (Standard Imaging, Madison, WI). Buildup caps for these detectors were fabricated out of M3, a water-equivalent material, and sheet-metal stock of Al, Cu, and Pb. Also, commercially available hemispherical buildup caps made of plastic water and brass (Landauer, Inc., Glenwood, IL) were used with Nanodots. OSLDs were read with an InLight microStar reader (Landauer, Inc., Glenwood, IL). Dose calculations were carried out with the XiO treatment planning system (CMS/Elekta, Stockholm) with tissue heterogeneity corrections. Results: For OSLDs and diodes, when measurements are made with no buildup cap a change in C{sub FS} of 200% occurs for a field-size change from 3 cm x 3 cm to 30 cm x 30 cm. The change in C{sub FS} is reduced to about 4% when a buildup cap with wall thickness equal to the depth of maximum dose is used. Buildup caps with larger wall thickness do not cause further reduction in C{sub FS}. The buildup cap fabrication material has little or no effect on C{sub FS}. The perturbation to the delivered dose caused by placing a detector with a buildup cap on the surface of a patient is measured to be 4%-7%. A comparison between calculated dose and dose measured with a Nanodot and a diode for 6 and 15 MV x-rays is made. When C{sub FS} factors are carefully determined and applied to measurements made on a phantom, the differences between measured and calculated doses were found to be between {+-}1.3%. Conclusions: OSLDs and diodes with appropriate buildup caps can be used to measure dose on the surface of a patient and predict the delivered dose to depth dmax in a range of {+-}1.3% for 100 cGy. The buildup cap: can be fabricated from any material examined in this work, is best with wall thickness dmax, and causes a perturbation to the delivered dose of 4%-7% when the wall thickness is dmax. OSLDs and diodes with buildup caps can both give accurate measurements of delivered dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Olivine electrode engineering impact on the electrochemical performance of lithium-ion batteries.

High energy and power density lithium iron phosphate was studied for hybrid electric vehicle applications. This work addresses the effects of porosity in a composite electrode using a four-point probe resistivity analyzer, galvanostatic cycling, and electrochemical impedance spectroscopy (EIS). The four-point probe result indicates that the porosity of composite electrode affects the electronic conductivity significantly. This effect is also observed from the cell's pulse current discharge performance. Compared to the direct current (dc) methods used, the EIS data are more sensitive to electrode porosity, especially for electrodes with low porosity values.

36 MATERIALS SCIENCE↗

Phase I Final Technical Report

Two subscale coils of Bi-2212 wire have been made and tested in a DOE 2018 STTR collaboration between Cryomagnetics and the Applied Superconductivity Center at Florida State University. These coils are used to test the feasibility of using small-diameter wire in a solenoidal configuration where single strand wire performance is crucial. If successful, the implementation of small-diameter wire into high field Bi-2212 HTS solenoids will allow for high J_E operation with moderate currents, making feasible the use of more modest control equipment, power supplies, and current leads. Furthermore, lower operating currents may allow series-connected design configurations with LTS background magnets, allowing for better, simpler, and more effective quench protection methods. A 25-Tesla magnet design, consisting of an 8-Tesla Bi-2212 coil with a 17-Tesla LTS coil, is fully underway at Cryomagnetics, and considerations of critical current, hoop stress, and quench protection will all be fully addressed. This document reports our findings up to this point, the end of the Phase I period.

36 MATERIALS SCIENCE↗

Radiological Verification for the Remediation of LLRW at the Port Granby Project - 19210

The Port Granby Project is part of the Port Hope Area Initiative (PHAI) that Canadian Nuclear Laboratory (CNL) is using to manage long-term historic low level radioactive waste (LLRW) resulting from 60 years of uranium and radium processing operations in the urban setting of Port Hope, Ontario. Port Granby remediation scope includes constructing a new, secure long-term waste management facility (LTWMF) and supporting infrastructure and excavating and relocating LLRW and marginally contaminated soil from the Port Granby Waste Management Facility (PGWMF) which accepted waste until the 1980's to the newly constructed LTWMF. The PGWMF contains an estimated 450,000 cubic meters of LLRW deposited in unmarked and unlined trenches throughout the southern portion of the site that borders Lake Ontario. Project requirements include excavating contaminated material, verifying that the trench bottoms are below action levels using Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) guidance, and final restoration. This paper describes challenges of meeting remediation verification requirements using traditional field and laboratory confirmation methods in areas of deep trench areas located in rugged terrain with ponded water and mud and presents a process that has expedited the traditional MARSSIM method for verification with greater productivity, and with enhanced safety and reliability as compared to the use of traditional methods alone. This enhanced process has been successfully employed for in-situ verification so that the excavated area can be backfilled and returned to a vegetative state. This enhanced process has been examined by federal regulatory staff through the course of their onsite audits and outcomes from these examinations have all been positive. The method involves a visual inspection and traditional walkover of the area to identify any areas with radiation measurements above the region's background followed by a full area survey performed using Wood's proprietary Orion ScanPlotSM system. The ScanPlotSM data is evaluated, mapped and overlaid on top of an aerial image of the surveyed area allowing remaining radiological material at surface or near surface to be quickly and easily identified for removal. Field staff then collect soil samples from evenly distributed points within the surveyed area and field screen the samples using an X-ray fluorescence (XRF) analysis for the three primary contaminates of potential concern (CoPCs) (arsenic, uranium and lead) that are indicative of the historical contamination. Samples passing XRF field screening are packaged and sent to a local laboratory for a full suite of analyses and checked against the CoPC list to assess whether the soil matches the profile for nearby native soils and passes the remediation goals. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE DEVELOPMENT OF A PARAMETERIZED SCATTER REMOVAL ALGORITHM FOR NUCLEAR MATERIALS IDENTIFICATION SYSTEM IMAGING

This report presents a novel method for removing scattering effects from Nuclear Materials Identification System (NMIS) imaging. The NMIS uses fast neutron radiography to generate images of the internal structure of objects nonintrusively. If the correct attenuation through the object is measured, the positions and macroscopic cross sections of features inside the object can be determined. The cross sections can then be used to identify the materials, and a 3D map of the interior of the object can be reconstructed. Unfortunately, the measured attenuation values are always too low because scattered neutrons contribute to the unattenuated neutron signal. Previous efforts to remove the scatter from NMIS imaging have focused on minimizing the fraction of scattered neutrons that are misidentified as directly transmitted by electronically collimating and time tagging the source neutrons. The parameterized scatter removal algorithm (PSRA) approaches the problem from an entirely new direction by using Monte Carlo simulations to estimate the point scatter functions (PScFs) produced by neutrons scattering in the object. PScFs have been used to remove scattering successfully in other applications, but only with simple 2D detector models. This work represents the first time PScFs have ever been applied to an imaging detector geometry as complicated as the NMIS. By fitting the PScFs using a Gaussian function, they can be parameterized, and the proper scatter for a given problem can be removed without the need for rerunning the simulations each time. In order to model the PScFs, an entirely new method for simulating NMIS measurements was developed for this work. The development of the new models and the codes required to simulate them are presented in detail. The PSRA was used on several simulated and experimental measurements, and chi-squared goodness of fit tests were used to compare the corrected values to the ideal values that would be expected with no scattering. Using the PSRA resulted in an improvement of the chi-squared test by a factor of 60 or more when applied to simple homogeneous objects.

Grogan, Brandon R↗

Displacement Threshold Energy and Recovery in an Al-Ti Nanolayered System with Intrinsic Point Defect Partitioning

A method is established and validated using molecular dynamics (MD) to determine the displacement threshold energies as Ed in nanolayered, multilayered systems of dissimilar metals. The method is applied to specifically oriented nanolayered films of Al-Ti where the crystal structure and interface orientations are varied in atomic models and Ed is calculated. Methods for defect detection are developed and discussed based on prior research in the literature and based on specific crystallographic directions available in the nanolayered systems. These are compared and contrasted to similar calculations in corresponding bulk materials, including fcc Al, fcc Ti, hcp Al, and hcp Ti. In all cases, the calculated Ed in the multilayers are intermediate to the corresponding bulk values but exhibit some important directionality. In the nanolayer, defect detection demonstrated systematic differences in the behavior of Ed in each layer. Importantly, collision cascade damage exhibits significant defect partitioning within the Al and Ti layers that is hypothesized to be an intrinsic property of dissimilar nanolayered systems. This type of partitioning could be partly responsible for observed asymmetric radiation damage responses in many multilayered systems. In addition, a pseudo-random direction was introduced to approximate the average Ed without performing numerous simulations with random directions.

Al-Ti↗

An Atlas-Based Electron Density Mapping Method for Magnetic Resonance Imaging (MRI)-Alone Treatment Planning and Adaptive MRI-Based Prostate Radiation Therapy

Purpose: Prostate radiation therapy dose planning directly on magnetic resonance imaging (MRI) scans would reduce costs and uncertainties due to multimodality image registration. Adaptive planning using a combined MRI-linear accelerator approach will also require dose calculations to be performed using MRI data. The aim of this work was to develop an atlas-based method to map realistic electron densities to MRI scans for dose calculations and digitally reconstructed radiograph (DRR) generation. Methods and Materials: Whole-pelvis MRI and CT scan data were collected from 39 prostate patients. Scans from 2 patients showed significantly different anatomy from that of the remaining patient population, and these patients were excluded. A whole-pelvis MRI atlas was generated based on the manually delineated MRI scans. In addition, a conjugate electron-density atlas was generated from the coregistered computed tomography (CT)-MRI scans. Pseudo-CT scans for each patient were automatically generated by global and nonrigid registration of the MRI atlas to the patient MRI scan, followed by application of the same transformations to the electron-density atlas. Comparisons were made between organ segmentations by using the Dice similarity coefficient (DSC) and point dose calculations for 26 patients on planning CT and pseudo-CT scans. Results: The agreement between pseudo-CT and planning CT was quantified by differences in the point dose at isocenter and distance to agreement in corresponding voxels. Dose differences were found to be less than 2%. Chi-squared values indicated that the planning CT and pseudo-CT dose distributions were equivalent. No significant differences (p > 0.9) were found between CT and pseudo-CT Hounsfield units for organs of interest. Mean {+-} standard deviation DSC scores for the atlas-based segmentation of the pelvic bones were 0.79 {+-} 0.12, 0.70 {+-} 0.14 for the prostate, 0.64 {+-} 0.16 for the bladder, and 0.63 {+-} 0.16 for the rectum. Conclusions: The electron-density atlas method provides the ability to automatically define organs and map realistic electron densities to MRI scans for radiotherapy dose planning and DRR generation. This method provides the necessary tools for MRI-alone treatment planning and adaptive MRI-based prostate radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Topological enhancement of nonlinear transport in unconventional point-node semimetals

The topological singularity of the Bloch states close to the Fermi level significantly enhances nonlinear electric responses in topological semimetals. Here, we systematically characterize this enhancement for a large class of topological nodal-point fermions, including those with linear, linear-quadratic, and quadratic dispersions. Specifically, we determine the leading power-law dependence of the nonlinear response functions on the chemical potential μ defined relative to the nodal point. We identify two characteristics that qualitatively improve nonlinear transports compared to those of conventional Dirac and Weyl fermions. First, the type-II (overtilted) spectrum leads to the log μ enhancement of nonlinear response functions having zero scaling dimension with respect to μ, which is not seen in a type-I (moderately or not tilted) spectrum. Second, the anisotropic linear-quadratic dispersion increases the power of small-μ divergence for the nonlinear response tensors along the linearly dispersing direction. Furthermore, our work reveals new experimental signatures of unconventional nodal points in topological semimetals as well as provides a guiding principle for giant nonlinear electric responses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Deformable image registration of heterogeneous human lung incorporating the bronchial tree

Purpose: To investigate the effect of the bronchial tree on the accuracy of biomechanical-based deformable image registration of human lungs. Methods: Three dimensional finite element models have been developed using four dimensional computed tomography image data of ten lung cancer patients. Each model is built of a body, left and right lungs, tumor, and bronchial trees. Triangular shell elements are used for the bronchial trees while tetrahedral elements are used for other components. Hyperelastic material properties based on experimental investigation on human lungs are used for the lung parenchyma. Different material properties are assigned for the bronchial tree using five values for the modulus of elasticity of 0.01, 0.12, 0.5, 10, and 18 MPa. Lungs are modeled to slide inside chest cavities by applying frictionless contact surfaces between each lung and corresponding chest cavity. The accuracy of the models is examined using an average of 40 bronchial bifurcation points identified on inhale and exhale images. Relative accuracy is evaluated by comparing the displacement of all nodes within the lungs as well as the dosimetric difference at the exhale position predicted by the model. Results: There is no significant effect of bronchial tree on the model accuracy based on the bifurcation points analysis. However, on the local level, using an average of 38 000 nodes, there is a maximum difference of 8.5 mm in the deformation of the bronchial trees, as the modulus of elasticity of the bronchial trees increases from 0.01 to 18 MPa; however, more than 96% of nodes are within a 2.5 mm difference in each direction. The average dose difference at the predicted exhale position is less than 35 cGy between the models. Conclusions: The bronchial tree has little effect on the global deformation and the accuracy of deformable image registration of lungs. Hence, the homogenous model is a reasonable assumption. Since there are some local deformation differences between nodes as the material properties of the bronchial tree change that may affect the accuracy of dosimetric results, heterogeneity may be required for a smaller scale modeling of lungs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Update and Improve Subsection NH –– Alternative Simplified Creep-Fatigue Design Methods

This report described the results of investigation on Task 10 of DOE/ASME Materials NGNP/Generation IV Project based on a contract between ASME Standards Technology, LLC (ASME ST-LLC) and Japan Atomic Energy Agency (JAEA). Task 10 is to Update and Improve Subsection NH -- Alternative Simplified Creep-Fatigue Design Methods. Five newly proposed promising creep-fatigue evaluation methods were investigated. Those are (1) modified ductility exhaustion method, (2) strain range separation method, (3) approach for pressure vessel application, (4) hybrid method of time fraction and ductility exhaustion, and (5) simplified model test approach. The outlines of those methods are presented first, and predictability of experimental results of these methods is demonstrated using the creep-fatigue data collected in previous Tasks 3 and 5. All the methods (except the simplified model test approach which is not ready for application) predicted experimental results fairly accurately. On the other hand, predicted creep-fatigue life in long-term regions showed considerable differences among the methodologies. These differences come from the concepts each method is based on. All the new methods investigated in this report have advantages over the currently employed time fraction rule and offer technical insights that should be thought much of in the improvement of creep-fatigue evaluation procedures. The main points of the modified ductility exhaustion method, the strain range separation method, the approach for pressure vessel application and the hybrid method can be reflected in the improvement of the current time fraction rule. The simplified mode test approach would offer a whole new advantage including robustness and simplicity which are definitely attractive but this approach is yet to be validated for implementation at this point. Therefore, this report recommends the following two steps as a course of improvement of NH based on newly proposed creep-fatigue evaluation methodologies. The first step is to modify the current approach by incorporating the partial advantages the new method offer, and the second step is to replace the current method by the simplified test approach when it has become technically mature enough. The recommendations are basically in line with the work scope of the Task Force on Creep-Fatigue of the Subgroup on Elevated Temperature Design of the Standards Committee of the ASME Boiler and Pressure Vessel Committee Section III.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Development of a Parameterized Scatter Removal Algorithm for Nuclear Materials Identification System Imaging

This dissertation presents a novel method for removing scattering effects from Nuclear Materials Identification System (NMIS) imaging. The NMIS uses fast neutron radiography to generate images of the internal structure of objects non-intrusively. If the correct attenuation through the object is measured, the positions and macroscopic cross-sections of features inside the object can be determined. The cross sections can then be used to identify the materials and a 3D map of the interior of the object can be reconstructed. Unfortunately, the measured attenuation values are always too low because scattered neutrons contribute to the unattenuated neutron signal. Previous efforts to remove the scatter from NMIS imaging have focused on minimizing the fraction of scattered neutrons which are misidentified as directly transmitted by electronically collimating and time tagging the source neutrons. The parameterized scatter removal algorithm (PSRA) approaches the problem from an entirely new direction by using Monte Carlo simulations to estimate the point scatter functions (PScFs) produced by neutrons scattering in the object. PScFs have been used to remove scattering successfully in other applications, but only with simple 2D detector models. This work represents the first time PScFs have ever been applied to an imaging detector geometry as complicated as the NMIS. By fitting the PScFs using a Gaussian function, they can be parameterized and the proper scatter for a given problem can be removed without the need for rerunning the simulations each time. In order to model the PScFs, an entirely new method for simulating NMIS measurements was developed for this work. The development of the new models and the codes required to simulate them are presented in detail. The PSRA was used on several simulated and experimental measurements and chi-squared goodness of fit tests were used to compare the corrected values to the ideal values that would be expected with no scattering. Using the PSRA resulted in an improvement of the chi-squared test by a factor of 60 or more when applied to simple homogeneous objects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Positional Reproducibility of Pancreatic Tumors Under End-Exhalation Breath-Hold Conditions Using a Visual Feedback Technique

Purpose: To assess positional reproducibility of pancreatic tumors under end-exhalation (EE) breath-hold (BH) conditions with a visual feedback technique based on computed tomography (CT) images. Methods and Materials: Ten patients with pancreatic cancer were enrolled in an institutional review board-approved trial. All patients were placed in a supine position on an individualized vacuum pillow with both arms raised. At the time of CT scan, they held their breath at EE with the aid of video goggles displaying their abdominal displacement. Each three-consecutive helical CT data set was acquired four times (sessions 1-4; session 1 corresponded to the time of CT simulation). The point of interest within or in proximity to a gross tumor volume was defined based on certain structural features. The positional variations in point of interest and margin size required to cover positional variations were assessed. Results: The means {+-} standard deviations (SDs) of intrafraction positional variations were 0.0 {+-} 1.1, 0.1 {+-} 1.2, and 0.1 {+-} 1.0 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively (p = 0.726). The means {+-} SDs of interfraction positional variations were 0.3 {+-} 2.0, 0.8 {+-} 1.8, and 0.3 {+-} 1.8 mm in the LR, AP, and SI directions, respectively (p = 0.533). Population-based margin sizes required to cover 95th percentiles of the overall positional variations were 4.7, 5.3, and 4.9 mm in the LR, AP, and SI directions, respectively. Conclusions: A margin size of 5 mm was needed to cover the 95th percentiles of the overall positional variations under EE-BH conditions, using this noninvasive approach to motion management for pancreatic tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Esophageal Dose Tolerance to Hypofractionated Stereotactic Body Radiation Therapy: Risk Factors for Late Toxicity

Purpose: To identify factors associated with grade ≥3 treatment related late esophageal toxicity after lung or liver stereotactic body radiation therapy (SBRT). Methods and Materials: This was a retrospective review of 52 patients with a planning target volume within 2 cm of the esophagus from a prospective registry of 607 lung and liver SBRT patients treated between 2005 and 2011. Patients were treated using a risk-adapted dose regimen to a median dose of 50 Gy in 5 fractions (range, 37.5-60 Gy in 3-10 fractions). Normal structures were contoured using Radiation Therapy Oncology Group (RTOG) defined criteria. Results: The median esophageal point dose and 1-cc dose were 32.3 Gy (range, 8.9-55.4 Gy) and 24.0 Gy (range, 7.8-50.9 Gy), respectively. Two patients had an esophageal fistula at a median of 8.4 months after SBRT, with maximum esophageal point doses of 51.5 and 52 Gy, and 1-cc doses of 48.1 and 50 Gy, respectively. These point and 1-cc doses were exceeded by 9 and 2 patients, respectively, without a fistula. The risk of a fistula for point doses exceeding 40, 45, and 50 Gy was 9.5% (n=2/21), 10.5% (n=2/19), and 12.5% (n=2/16), respectively. The risk of fistula for 1-cc doses exceeding 40, 45, and 50 Gy was 25% (n=2/9), 50% (n=2/4), and 50% (n=2/4), respectively. Eighteen patients received systemic therapy after SBRT (11 systemic chemotherapy, and 6 biologic agents, and 1 both). Both patients with fistulas had received adjuvant anti-angiogenic (vascular endothelial growth factor) agents within 2 months of completing SBRT. No patient had a fistula in the absence of adjuvant VEGF-modulating agents. Conclusions: Esophageal fistula is a rare complication of SBRT. In this series, fistula was seen with esophageal point doses exceeding 51 Gy and 1-cc doses greater than 48 Gy. Notably, however, fistula was seen only in those patients who also received adjuvant VEGF-modulating agents after SBRT. The potential interaction of dose and adjuvant therapy should be considered when delivering SBRT near the esophagus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GPU-Accelerated Solution of the Bethe–Salpeter Equation for Large and Heterogeneous Systems

We present a massively parallel GPU-accelerated implementation of the Bethe–Salpeter equation (BSE) for the calculation of the vertical excitation energies (VEEs) and optical absorption spectra of condensed and molecular systems, starting from single-particle eigenvalues and eigenvectors obtained with density functional theory. The algorithms adopted here circumvent the slowly converging sums over empty and occupied states and the inversion of large dielectric matrices through a density matrix perturbation theory approach and a low-rank decomposition of the screened Coulomb interaction, respectively. Further computational savings are achieved by exploiting the nearsightedness of the density matrix of semiconductors and insulators to reduce the number of screened Coulomb integrals. We scale our calculations to thousands of GPUs with a hierarchical loop and data distribution strategy. The efficacy of our method is demonstrated by computing the VEEs of several spin defects in wide-band-gap materials, showing that supercells with up to 1000 atoms are necessary to obtain converged results. We discuss the validity of the common approximation that solves the BSE with truncated sums over empty and occupied states. In conclusion, we then apply our GW-BSE implementation to a diamond lattice with 1727 atoms to study the symmetry breaking of triplet states caused by the interaction of a point defect with an extended line defect.

Absorption spectra↗