Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

NASA Tech Briefs, February 2005

Topics discussed include: Instrumentation for Sensitive Gas Measurements; Apparatus for Testing Flat Specimens of Thermal Insulation; Quadrupole Ion Mass Spectrometer for Masses of 2 to 50 Da; Miniature Laser Doppler Velocimeter for Measuring Wall Shear; Coherent Laser Instrument Would Measure Range and Velocity; Printed Microinductors for Flexible Substrates; Digital Receiver for Microwave Radiometry; Printed Antennas Made Reconfigurable by Use of MEMS Switches; Traffic-Light-Preemption Vehicle-Transponder Software Module; Intersection-Controller Software Module; Central-Monitor Software Module; Estimating Effects of Multipath Propagation on GPS Signals; Parallel Adaptive Mesh Refinement Library; Predicting Noise From Aircraft Turbine-Engine Combustors; Generating Animated Displays of Spacecraft Orbits; Diagnosis and Prognosis of Weapon Systems; Training Software in Artificial-Intelligence Computing Techniques; APGEN Version 5.0; Single-Command Approach and Instrument Placement by a Robot on a Target; Three-Dimensional Audio Client Library; Isogrid Membranes for Precise, Singly Curved Reflectors; Nickel-Tin Electrode Materials for Nonaqueous Li-Ion Cells; Photocatalytic Coats in Glass Drinking-Water Bottles; Fast Laser Shutters With Low Vibratory Disturbances; Series-Connected Buck Boost Regulators; Space Physics Data Facility Web Services; Split-Resonator, Integrated-Post Vibratory Microgyroscope; Blended Buffet-Load-Alleviation System for Fighter Airplane; Gifford-McMahon/Joule-Thomson Refrigerator Cools to 2.5 K; High-Temperature, High-Load-Capacity Radial Magnetic Bearing; Fabrication of Spherical Reflectors in Outer Space; Automated Rapid Prototyping of 3D Ceramic Parts; Tissue Engineering Using Transfected Growth-Factor Genes; Automation of Vapor-Diffusion Growth of Protein Crystals; Atom Skimmers and Atom Lasers Utilizing Them; Gears Based on Carbon Nanotubes; Patched Off-Axis Bending/Twisting Actuators for Thin Mirrors; and Improving Control in a Joule-Thomson Refrigerator.

Source record↗

Seismic anisotropy of serpentinite from Val Malenco, Italy

Serpentinites, deformed in mantle subduction zones, are thought to contribute significantly to seismic anisotropy of the upper mantle and have therefore been of great interest with studies on deformation, preferred orientation, and elastic properties. Here we present a combined study of a classical sample from Val Malenco, Italy, investigating the microstructure and texture with state-of-the art synchrotron X-ray and neutron diffraction methods and measuring ultrasonic velocities both with a multi-anvil apparatus and a novel instrument to measure 3-D velocities on spheres. Both, results from diffraction methods and velocity measurements are compared, discussing advantages and disadvantages. From spherical velocities, elastic tensor properties can be derived by inversion. Also from quantitative texture measurements, elastic properties can be modeled by self-consistent averaging. We report good agreement between the velocity and microstructural models is observed.

58 GEOSCIENCES↗

CFD modeling of natural circulation in LiCl-KCl molten salt closed loop

Characterizing flow within a molten salt closed-loop system is crucial for assessing system requirements, evaluating performance, and identifying potential flaws. Direct flow measurement using instrumentation is challenging due to extreme environmental conditions and the limitations associated with measuring molten salt flow under natural convection. Here, this study aims to provide comprehensive insights into the thermal-hydraulic behavior of a closed loop, with a particular focus on temperature distribution and velocity prediction. The Computational Fluid Dynamics (CFD) model demonstrated the capability to effectively simulate and predict both temperature distributions and flow velocities within the molten salt loop. The CFD model's predictive capability was validated by its ability to replicate temperature measurements under varying boundary conditions. The analysis revealed that the CFD model tends to underpredict temperatures in the cold leg and overpredict them in the hot leg, highlighting the need for continuous model refinement and acknowledging the limitations of using a steady-state approach. Furthermore, the potential of using external temperature measurements to estimate internal molten salt temperatures and predict flow velocity was explored, revealing that this approach could introduce up to a 5.5% error in flow velocity calculations. Line probes mapping temperature distributions across the tube's cross-section and molten salt provided valuable insights into temperature gradients, emphasizing the need for a thermal conductivity equation for molten salt with lower uncertainty to achieve more accurate temperature predictions of the system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of the Neutron Fields in the Lawrence Livermore National Laboratory (LLNL) Radiation Calibration Laboratory Low Scatter Facility

The issuance of Part 10 CFR 835 (2007) with revised radiation weighting factors and the installation of a new Hopewell N40 irradiator necessitated a re-characterization of the neutron fields in RCL's Low Scatter Calibration Facility (B255, Room 183 A). The emission rates of the RCL's two 252 Cf calibration sources were re-evaluated and the updated emission rates are provided in Appendix A. The neutron dose rates from the new Hopewell N40 irradiator configuration were evaluated using three different instruments. the measurement methodology and the experimental set up as well as calibration of the instruments are discussed in detail.

61 RADIATION PROTECTION AND DOSIMETRY↗

An optical quality meter suitable for cryogenic liquids

Construction of instrument to measure ratio of liquid to gas of flowing transparent cryogenic fluid is described. Instrument consists of collimated light source and photoconductive cell. Operation of instrument is described and illustration of equipment is provided.

Hobart, H. F.↗

Energetic atomic and molecular ions of ionospheric origin observed in distant magnetotail flow-reversal events

Energetic atomic (O(+1) and N(+1)) and molecular (O2(+1), NO(+1), and N2(+1)) ions of ionospheric origin were observed in Earth's magnetotail at X approximately -146 R(sub E) during two plasma sheet sunward/tailward flow-reversal events measured by instruments on the GEOTAIL spacecraft. These events were associated with concurrent ground-measured geomagnetic disturbance intensification at auroral-and mid-latitudes (Kp = 7(-)). Energetic ions in the sunward-component and tailward flows were from both the solar wind and ionosphere. Plasma and energetic ions participated in the flows. During tailward flow, ionospheric origin ion abundance ratios at approximately 200-900 km/s in the rest frame were N(+1)/O(+1) = approximately 25-30% and ((O2(+1), NO(+1), and N2(+1))/O(+1) = approximately 1-2%. We argue that tailward flow most likely initiated approximately 80-100 R(sub E) tailward of Earth and molecular ions were in the plasma sheet prior to geomagnetic intensification onset.

Christon, S. P.↗

Photolysis Rate Coefficient Calculations in Support of SOLVE Campaign

The objectives for this SOLVE project were 3-fold. First, we sought to calculate a complete set of photolysis rate coefficients (j-values) for the campaign along the ER-2 and DC-8 flight tracks. En route to this goal, it would be necessary to develop a comprehensive set of input geophysical conditions (e.g., ozone profiles), derived from various climatological, aircraft, and remotely sensed datasets, in order to model the radiative transfer of the atmosphere accurately. These j-values would then need validation by comparison with flux-derived j-value measurements. The second objective was to analyze chemistry along back trajectories using the NASA/Goddard chemistry trajectory model initialized with measurements of trace atmospheric constituents. This modeling effort would provide insight into the completeness of current measurements and the chemistry of Arctic wintertime ozone loss. Finally, we sought to coordinate stellar occultation measurements of ozone (and thus ozone loss) during SOLVE using the MSX/UVISI satellite instrument. Such measurements would determine ozone loss during the Arctic polar night and represent the first significant science application of space-based stellar occultation in the Earth's atmosphere.

Lloyd, Steven A.↗

Kinetic Temperature and Carbon Dioxide from Broadband Infrared Limb Emission Measurements Taken from the TIMED/SABER Instrument

The Sounding of the Atmosphere using Broadband Emission Radiometry (SABER) experiment is one of four instruments on NASA's Thermosphere-Ionosphere-Energetics and Dynamics (TIMED) satellite. SABER measures broadband infrared limb emission and derives vertical profiles of kinetic temperature (Tk) from the lower stratosphere to approximately 120 km, and vertical profiles of carbon dioxide (CO2) volume mixing ratio (vmr) from approximately 70 km to 120 km. In this paper we report on SABER Tk/CO2 data in the mesosphere and lower thermosphere (MLT) region from the version 1.06 dataset. The continuous SABER measurements provide an excellent dataset to understand the evolution and mechanisms responsible for the global two-level structure of the mesopause altitude. SABER MLT Tk comparisons with ground-based sodium lidar and rocket falling sphere Tk measurements are generally in good agreement. However, SABER CO2 data differs significantly from TIME-GCM model simulations. Indirect CO2 validation through SABER-lidar MLT Tk comparisons and SABER-radiation transfer comparisons of nighttime 4.3 micron limb emission suggest the SABER-derived CO2 data is a better representation of the true atmospheric MLT CO2 abundance compared to model simulations of CO2 vmr.

Mertens, Christopher J.↗

The Mark III stellar interferometer

The Mark III interferometer is an operational long baseline stellar interferometer on Mt. Wilson with four-possible baseline configurations from 9m NE-SW to 20m N-S. The interferometer was designed to be a highly automated astronomical instrument to measure stellar positions and diameters to a magnitude limit of seven. Initial fringe observations were made in September 1986 with a 12-m N-S baseline. In the following months, semi-automated astrometric and stellar diameter measurements were also made. This paper describes the hardware and software components of the instrument and its operational characteristics. The interferometer has several novel features. One is the use of optimal estimation and control algorithms (e.g. Kalman filters) in the control loops. Another is the ability to operate both as a closed-loop phased interferometer and eventually as an open-loop or absolute coherent interferometer. High thermal stability and mechanical accuracy should permit the instrument to point blind at an astronomical object and maintain optical path equality to within the limits set by the atmosphere. In this absolute interferometric mode of operation, it should be possible to observe faint astronomical objects that are too dim for phase tracking. In theory, measurements of amplitude, group delay, and closure phase will be possible to 14 mag.

Shao, M.↗

GeoCarb Calibration Campaign Field Campaign Report

The GeoCarb Calibration Campaign, referred to as the Total Carbon Column Observing Network (TCCON) calibration campaign within this report for clarity, involved a series of single- and multiple-day Bruker EM27/SUN Fourier transform infrared (FTIR) spectrometer deployments at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory in Oklahoma. The EM27/SUN instruments directly measure infrared solar radiation in a wavelength range from 4000 to 11000 cm -1 at a spectral resolution of 0.5 cm -1 and varied temporal resolution of approximately 15 seconds. The solar radiation observed by these spectrometers contains information about the concentrations of atmospheric constituents present between the instruments and the top of the atmosphere, as every gas and particle in the atmosphere absorbs solar radiation at different wavelengths depending on their physical and chemical makeup. Through retrieval algorithm processing, the solar radiation data collected by EM27/SUN instruments can be used to infer total column dry-air mole fractions, or total column concentrations, of different trace gases present in the atmosphere. These total column concentrations, denoted as Xgas , represent the concentration, in ppb or ppm, of a trace gas in the column of atmosphere between an instrument and the top of the atmosphere. EM27/SUN instruments are primarily used to infer total column concentrations of carbon dioxide (CO 2 ), carbon monoxide (CO), methane (CH 4 ), and water vapor.

54 ENVIRONMENTAL SCIENCES↗

Micrometeoroid and Lunar Secondary Ejecta Flux Measurements: Comparison of Three Acoustic Systems

This report examines the inherent capability of three large-area acoustic sensor systems and their applicability for micrometeoroids (MM) and lunar secondary ejecta (SE) detection and characterization for future lunar exploration activities. Discussion is limited to instruments that can be fabricated and deployed with low resource requirements. Previously deployed impact detection probes typically have instrumented capture areas less than 0.2 square meters. Since the particle flux decreases rapidly with increased particle size, such small-area sensors rarely encounter particles in the size range above 50 microns, and even their sampling the population above 10 microns is typically limited. Characterizing the sparse dust population in the size range above 50 microns requires a very large-area capture instrument. However it is also important that such an instrument simultaneously measures the population of the smaller particles, so as to provide a complete instantaneous snapshot of the population. For lunar or planetary surface studies, the system constraints are significant. The instrument must be as large as possible to sample the population of the largest MM. This is needed to reliably assess the particle impact risks and to develop cost-effective shielding designs for habitats, astronauts, and critical instrument. The instrument should also have very high sensitivity to measure the flux of small and slow SE particles. is the SE environment is currently poorly characterized, and possess a contamination risk to machinery and personnel involved in exploration. Deployment also requires that the instrument add very little additional mass to the spacecraft. Three acoustic systems are being explored for this application.

Corsaro, R. D.↗

PACE UV-VIS Polarimetric Remote Sensing of Atmosphere-Ocean Systems: Sensitivity to Variations in Brown Carbon

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission, scheduled for launch in 2024, will carry two instruments that measure ultraviolet (UV) radiance emerging from the top of the atmosphere: the Ocean Color Instrument (OCI) and the Spectro-Polarimeter for Planetary Exploration (SPEXone) instrument. OCI will provide single-view, hyperspectral radiometric data, whereas SPEXone will provide multi-angle, multispectral polarimetric data. Together, these instruments will be the most advanced in NASA’s history for the combined observation of ocean color and atmospheric aerosols in the UV, and they will therefore provide unprecedented research opportunities for the ocean color and atmospheric aerosol communities. In particular, UV observations are best suited to retrieve properties of Colored Dissolved Organic Matter (CDOM) in the ocean, and of Brown Carbon (BrC) aerosols in the atmosphere. However, both CDOM and BrC exhibit very similar absorption spectra in the UV and the visible (VIS) spectrum; hence, care must be taken in accurately modeling these spectra for analyses of OCI and SPEXone measurements. In this presentation, we summarize a simple but highly accurate three-parameter model for complex refractive index spectra of BrC in the UV and VIS. We apply this model to simulations of PACE-like total and polarized multiangle radiance in the UV, and demonstrate that the impact of BrC and CDOM variations can be similar in total radiance, but is easy to distinguish in polarized radiance.

PACE↗

Experimental methods for laboratory measurements of helium spectral line broadening in white dwarf photospheres

White Dwarf (WD) stars are the most common stellar remnant in the universe. WDs usually have a hydrogen or helium atmosphere, and helium WD (called DB) spectra can be used to solve outstanding problems in stellar and galactic evolution. DB origins, which are still a mystery, must be known to solve these problems. DB masses are crucial for discriminating between different proposed DB evolutionary hypotheses. Current DB mass determination methods deliver conflicting results. The spectroscopic mass determination method relies on line broadening models that have not been validated at DB atmosphere conditions. We performed helium benchmark experiments using the White Dwarf Photosphere Experiment (WDPE) platform at Sandia National Laboratories' Z-machine that aims to study He line broadening at DB conditions. Using hydrogen/helium mixture plasmas allows investigating the importance of He Stark and van der Waals broadening simultaneously. Accurate experimental data reduction methods are essential to test these line-broadening theories. In this paper, we present data calibration methods for these benchmark He line shape experiments. We give a detailed account of data processing, spectral power calibrations, and instrument broadening measurements. Uncertainties for each data calibration step are also derived. We demonstrate that our experiments meet all benchmark experiment accuracy requirements: WDPE wavelength uncertainties are <1 Å, spectral powers can be determined to within 15%, densities are accurate at the 20% level, and instrumental broadening can be measured with 20% accuracy. Fulfilling these stringent requirements enables WDPE experimental data to provide physically meaningful conclusions about line broadening at DB conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Pioneer Venus Orbiter Electron Temperature Probe

The Orbiter Electron Temperature Probe (OETP) instrumentation and measurement technique has been designed to perform in-situ measurements of electron temperature and electron and ion density in the ionosphere of Venus. Adaptive sweep voltage circuitry continuously tracks the changing electron temperature and spacecraft potential while auto-ranging electrometers adjust their gain in response to the changing plasma density. Control signals used in the instrument to achieve this automatic tracking provide a continuous monitor of the ionospheric parameters without telemetering each volt-ampere curve. Internal data storage permits high data rate sampling of selected raw characteristic curves for low rate transmission to earth. These curves are used to verify or correct the inflight processed data. Sample in orbit measurements are presented to demonstrate instrument performance.

Krehbiel, J. P.↗

Cosmological implications of DESI DR2 BAO measurements in light of the latest ACT DR6 CMB data

We report cosmological results from the Dark Energy Spectroscopic Instrument (DESI) measurements of baryon acoustic oscillations (BAO) when combined with recent data from the Atacama Cosmology Telescope (ACT). By jointly analyzing ACT and Planck data and applying conservative cuts to overlapping multipole ranges, we assess how different 𝑃⁢𝑙⁢𝑎⁢𝑛⁢𝑐⁢𝑘 + ACT dataset combinations affect consistency with DESI. While ACT alone exhibits a tension with DESI exceeding 3⁢𝜎 within the Λ⁢ CDM model, this discrepancy is reduced when ACT is analyzed in combination with Planck. For our baseline DESI DR2 BAO + 𝑃⁢𝑙⁢𝑎⁢𝑛⁢𝑐⁢𝑘 P⁢R⁢4 + ACT likelihood combination, the preference for evolving dark energy over a cosmological constant is about 3⁢𝜎, increasing to over 4⁢𝜎 with the inclusion of type Ia supernova data. While the dark energy results remain quite consistent across various combinations of Planck and ACT likelihoods with those obtained by the DESI collaboration, the constraints on neutrino mass are more sensitive, ranging from ∑𝑚 𝜈 < 0.061 eV in our baseline analysis, to ∑𝑚 𝜈 < 0.077 eV (95% confidence level) in the CMB likelihood combination chosen by ACT when imposing the physical prior ∑𝑚 𝜈 > 0 eV.

79 ASTRONOMY AND ASTROPHYSICS↗

Quadrispherical LEPEDEAS for ISEE's-1 and -2 plasma measurements

A new generation of spaceflight instrumentation for comprehensive measurements of plasmas within the earth's magnetosphere and its environs is described. These quadrispherical low energy proton and electron differential energy analyzers (LEPEDEAS) for the ISEE's-1 and -2 spacecraft are capable of determining the directional intensities of positive ions and electrons over all but 2 percent of the 4 pi sr solid angle for charged-particle velocity vectors at the spacecraft positions. The energy range of this instrumentation is E/Q of 1 eV to 45 keV with good energy and angular resolutions. An example of inflight observations within the earth's magnetosheath is presented.

Frank, L. A.↗

TPSAS-NF1676L-11930-DND

Under the NASA Laser Risk Reduction Program (LRRP), funded by Earth Science Technology Office (ESTO), an efficient, injection seeded, high repetition rate Tm:fiber laser pumped Ho:YLF laser has been developed and operation between 100 Hz to 10 kHz has been demonstrated. The work is underway to develop an efficient, high-repetition-rate, pulsed, 2-micron, coherent Differential Absorption Lidar (DIAL) / Integrated Path Differential Absorption (IPDA) instrument for measuring the atmospheric CO2 profiles (DIAL) and column densities (IPDA) from an airborne platform. In DIAL mode, this instrument will provide the first ever range-resolved, high-precision, remote measurements of the CO2 content of the atmospheric boundary layer (ABL) and lower troposphere.

Upendra N Singh↗