Search NASA⌕ Search

SEARCH · Search NASA

Results for “MicroED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Pilot study for compact microbeam radiation therapy using a carbon nanotube field emission micro-CT scanner

Purpose: Microbeam radiation therapy (MRT) is defined as the use of parallel, microplanar x-ray beams with an energy spectrum between 50 and 300 keV for cancer treatment and brain radiosurgery. Up until now, the possibilities of MRT have mainly been studied using synchrotron sources due to their high flux (100s Gy/s) and approximately parallel x-ray paths. The authors have proposed a compact x-ray based MRT system capable of delivering MRT dose distributions at a high dose rate. This system would employ carbon nanotube (CNT) field emission technology to create an x-ray source array that surrounds the target of irradiation. Using such a geometry, multiple collimators would shape the irradiation from this array into multiple microbeams that would then overlap or interlace in the target region. This pilot study demonstrates the feasibility of attaining a high dose rate and parallel microbeam beams using such a system. Methods: The microbeam dose distribution was generated by our CNT micro-CT scanner (100μm focal spot) and a custom-made microbeam collimator. An alignment assembly was fabricated and attached to the scanner in order to collimate and superimpose beams coming from different gantry positions. The MRT dose distribution was measured using two orthogonal radiochromic films embedded inside a cylindrical phantom. This target was irradiated with microbeams incident from 44 different gantry angles to simulate an array of x-ray sources as in the proposed compact CNT-based MRT system. Finally, phantom translation in a direction perpendicular to the microplanar beams was used to simulate the use of multiple parallel microbeams. Results: Microbeams delivered from 44 gantry angles were superimposed to form a single microbeam dose distribution in the phantom with a FWHM of 300μm (calculated value was 290 μm). Also, during the multiple beam simulation, a peak to valley dose ratio of ∼10 was found when the phantom translation distance was roughly 4x the beam width. The first prototype CNT-based x-ray tube dedicated to the development of compact MRT technology development was proposed and planned based on the preliminary experimental results presented here and the previous corresponding Monte Carlo simulations. Conclusions: The authors have demonstrated the feasibility of creating microbeam dose distributions at a high dose rate using a proposed compact MRT system. The flexibility of CNT field emission x-ray sources could possibly bring compact and low cost MRT devices to the larger research community and assist in the translational research of this promising new approach to radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-BRE-01: A High Resolution Micro Fiber Scintillator Detector Optimized for SRS and SBRT in Vivo Real Time Treatment Verification

Purpose: We have built a high resolution real time scintillating fiber detector prototype to determine in real time the accuracy of stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT) treatments when only a fraction of the planned dose was delivered. The motivation of this work is to enhance dose delivery accuracy and to achieve error free radiosurgery. Methods: A high density array of scintillating fibers and a high speed photo detectors array were integrated to implement a high resolution real time dosimeter that can sample with high resolution pulsed SRS and SBRT beams cross sections. The high efficiency of the developed system allows to read each linac pulse in real time and to compute the accumulated dose and dose errors when only a fraction of the beam was delivered. The fibers are highly packed in a substrate that is directly coupled to two 128 pixel arrays with a pitch matching the fiber spacing to achieve accurate spatial localization. The small cross section of the fiber array allows stacking multiple fiber arrays to measure independent angular profiles that are digitally processed in parallel for real time dosimetry. Results: We implemented a high density array detector prototype with a pitch of 0.5 mm, readout speed of 1.2 msec, and a response time of 0.5 usec. The fast reading speed has the capability to determining the dose in flattening free filter beams. The detector can be installed in transmission mode at the output port of a micro-MLC. Treatment deviations smaller than 3% are detected when less than 1/100 of the planned dose was delivered. Conclusions: We built a prototype of a high resolution fiber scintillator array detector for SRS and SBRT in vivo dosimetry. Results show that the developed detector has the potential to assure error free SRS and SBRT treatments.

60 APPLIED LIFE SCIENCES↗

TU-F-18C-08: Micro-Calcification Detectability Using Spectral Breast CT Based On a Si Strip Detector

Purpose: To investigate the feasibility of micro-calcification (μCa) detectability by using an energy-resolved photon-counting Si strip detector for spectral breast computed tomography (CT). Methods: A bench-top CT system was constructed using a tungsten anode x-ray source with a focal spot size of 0.8 mm and a single line 256-pixel Si strip photon counting detector with a pixel pitch of 100 μm. The slice thickness was 0.5 mm. Five different size groups of calcium carbonate grains, from 105 to 215 μm in diameter, were embedded in a cylindrical resin phantom with a diameter of 16 mm to simulate μCas. The phantoms were imaged at 65 kVp with an Entrance Skin Air Kerma (ESAK) of 1.2, 3, 6, and 8 mGy. The images were reconstructed using a standard filtered back projection (FBP) with a ramp filter. A total of 200 μCa images (5 different sizes of μCas × 4 different doses × 10 images for each setting) were combined with another 200 control images without μCas, to ultimately form 400 images for the reader study. The images were displayed in random order to three blinded observers, who were asked to give a binary score on each image regarding the presence of μCas. The μCa detectability for each image was evaluated in terms of binary decision theory metrics. The sensitivity, specificity, and accuracy were calculated to study the size and dose-dependence for μCa detectability. Additionally, the influence of the partial volume effect on the μCa detectability was investigated by simulation. Results: For a μCa larger than 140 μm in diameter, detection accuracy of above 90 % was achieved with the investigated prototype spectral CT system at ESAK of 1.2 mGy. Conclusion: The proposed Si strip detector is expected to offer superior image quality with the capability to detect μCas for low dose breast imaging.

60 APPLIED LIFE SCIENCES↗

SU-C-BRE-01: 3D Conformal Micro Irradiation Results of Four Treatment Sites for Preclinical Small Animal and Clinical Treatment Plans

Purpose: Small animal irradiation can provide preclinical insights necessary for clinical advancement. In order to provide clinically relevant data, these small animal irradiations must be designed such that the treatment methods and results are comparable to clinical protocols, regardless of variations in treatment size and modality. Methods: Small animal treatments for four treatment sites (brain, liver, lung and spine) were investigated, accounting for change in treatment energy and target size. Up to five orthovoltage (300kVp) beams were used in the preclinical treatments, using circular, square, and conformal tungsten apertures, based on the treatment site. Treatments were delivered using the image guided micro irradiator (microIGRT). The plans were delivered to a mouse sized phantom and dose measurements in axial and coronal planes were performed using radiochromic film. The results of the clinical and preclinical protocols were characterized in terms of conformality number, CTV coverage, dose nonuniformity ratio, and organ at risk sparing. Results: Preclinical small animal treatment conformality was within 1–16% of clinical results for all treatment sites. The volume of the CTV receiving 100% of the prescription dose was typically within 10% of clinical values. The dose non-uniformity was consistently higher for preclinical treatments compared to clinical treatments, indicating hot spots in the target. The ratios of the mean dose in the target to the mean dose in an organ at risk were comparable if not better for preclinical versus clinical treatments. Finally, QUANTEC dose constraints were applied and the recommended morbidity limits were satisfied in each small animal treatment site. Conclusion: We have shown that for four treatment sites, preclinical 3D conformal small animal treatments can be clinically comparable if clinical protocols are followed. Using clinical protocols as the standard, preclinical irradiation methods can be altered and iteratively improved to achieve a clinically relevant irradiation model.

60 APPLIED LIFE SCIENCES↗

SU-E-I-53: Comparison of Kerma-Area-Product Between the Micro-Angiographic Fluoroscope (MAF) and a Flat Panel Detector (FPD) as Used in Neuro-Endovascular Procedures

Purpose: To determine the reduction of integral dose to the patient when using the micro-angiographic fluoroscope (MAF) compared to when using the standard flat-panel detector (FPD) for the techniques used during neurointerventional procedures. Methods: The MAF is a small field-of-view, high resolution x-ray detector which captures 1024 x 1024 pixels with an effective pixel size of 35μm and is capable of real-time imaging up to 30 frames per second. The MAF was used in neuro-interventions during those parts of the procedure when high resolution was needed and the FPD was used otherwise. The technique parameters were recorded when each detector was used and the kerma-area-product (KAP) per image frame was determined. KAP values were calculated for seven neuro interventions using premeasured calibration files of output as a function of kVp and beam filtration and included the attenuation of the patient table for the frontal projections to be more representative of integral patient dose. The air kerma at the patient entrance was multiplied by the beam area at that point to obtain the KAP values. The ranges of KAP values per frame were determined for the range of technique parameters used during the clinical procedures. To appreciate the benefit of the higher MAF resolution in the region of interventional activity, DA technique parameters were generally used with the MAF. Results: The lowest and highest values of KAP per frame for the MAF in DA mode were 4 and 50 times lower, respectively, compared to those of the FPD in pulsed fluoroscopy mode. Conclusion: The MAF was used in those parts of the clinical procedures when high resolution and image quality was essential. The integral patient dose as represented by the KAP value was substantially lower when using the MAF than when using the FPD due to the much smaller volume of tissue irradiated. This research was supported in part by Toshiba Medical Systems Corporation and NIH Grant R01EB002873.

60 APPLIED LIFE SCIENCES↗

SU-E-T-44: A Micro-Raman Spectroscopy Study of the Dose-Dependence of EBT3 GafChromicTM Films for Quantifying the Degree of Molecular Polymerization

Purpose: Radiochromic films, such as the poly-diacetylene-based EBT3 GafChromic{sup TM} films (Ashland Specialty Ingredients, Wayne, NY, USA), are widely used for dosimetry applications because of their clear energy independence, high spatial resolution, near tissue equivalence and easy handling. The films undergo a slight color change by radiation-induced polymerization of diacetylene monomers. But more importantly, the film becomes optically less transparent with increasing radiation dose, with a saturation starting between 10 and 20 Gy, i.e. a common SBRT dose level. In contrast to the chromatic properties, less attention has been given to the underlying molecular mechanism that induces this partial color change and strongly reduces the transparency. Therefore, the current work investigates the variation of the molecular composition of the active layer of EBT3 films for an SBRT dose range. Method: Uncoated EBT3 films were irradiated with a 6 MV photon beam using dose levels between 0 and 20 Gy. The relative variation of the polymer content as a function of the applied radiation dose was studied using micro-Raman spectroscopy. Raman spectroscopy with a 633 nm probe laser incident on the active layer allowed to identify the film constituents and to estimate the amount of poly-diacetylenes from the intensities of the unique molecular vibrations of the molecule. Results: The normalized intensity of all polymeric vibrations, and most notably the polymeric triple and double carbon-carbon bonds at 2058 cm{sup −1} and 1446 cm{sup −1} respectively, increase with increasing dose up to a saturation level starting at about 10 Gy, indicating a corresponding increase and saturation of the amount of polymers. This molecular saturation process is the main cause of the non-linear dose response (i.e. a transparency reduction) and of the limited dose range of the studied films. Conclusion: Raman spectroscopy provides new and more fundamental insights in the mechanism of the dose-dependence of EBT3 films. This work was funded by the Research Foundation - Flanders (FWO)

60 APPLIED LIFE SCIENCES↗

SU-E-T-771: Two Dimensional Raman Mapping of Carbon Bonds of Radiochromic Films: An Approach to Micro-Dosimetry

Purpose: To study a feasibility of micro-dosimetry with high dose-sensitivity and resolution using two-dimensional Raman mapping on the basis of carbon bonds concentration of radiochromic films Methods: Unlaminated EBT3 films with the purpose of maximal Raman data acquisition were irradiated by 6 MV beam from 5 MU to 1000 MU at the reference condition. Each film was irradiated with shielding material of lead blocking on the half of film as well as the jaw open in half for distinct dose contrast. Raman peaks of 2070 cm-1, 2095 cm-1, and 2115 cm-1 were major subjects to study, which are assumed to be the spectroscopy of carbon triple bonds of monomers, carbon double bonds of polymers, and carbon triple bonds of polymers, respectively. Laser exposure for Raman spectroscopy generated peak’s trend due to polymerization by laser output and this trend was utilized to find out basic peaks related to polymerization process. The relative dose contrast in each one film was detected by Raman spectroscopy with the aid of an auto-scanning stage, comparing the dose contrast between non-irradiated area and irradiated area. Raman spatial resolution was enhanced up to 20 micrometers, assuming the spatial uniformity of radio¬active rod-shaped LiPCDA crystals. An optical scanner with 9600 dpi was used to scan the red-channel intensity to read the dose contrast for 5 MU delivered film. Results: The peak intensity for Raman wavenumber of 2070 cm-1 was used for mapping since it reflected the different peak intensities based on polymerization degree by irradiation. Dose contrast from 1000MU to 5 MU was distinguished by Raman mapping analysis, whereas optical intensity of red-channel didn’t show any difference. Conclusion: In consideration of laser effect, the quantitative analysis based on raw data of Raman mapping could provide more statistically reliable dosimetry than point measurements.

60 APPLIED LIFE SCIENCES↗

Controlling the macro- and micro-processes influenсing harmonic generation in laser-produced plasmas

We review the studies of the spatial conditions for the quasi-phase-matching in the multi-jet laserproduced silver plasma. These studies of the off-axis and on-axis spatial components of harmonics allowed the demonstration of significant enhancement of a group of harmonics in the latter case. We analyze the role of plasma emission, together with phase-mismatch, that deteriorate the conditions of high-order harmonic generation due to significant phase distortion between the interacting waves. We also discuss the resonanceinduced enhancement of single harmonic and the quasi-phase-matching-induced enhancement of the group of harmonics during propagation of the tunable mid-infrared femtosecond pulses through the perforated laser-produced indium plasma. Those studies have shown that the enhancement of harmonics using the macro-process of quasi-phase-matching is comparable with the one using micro-process of resonantly enhanced harmonic. We conclude that joint implementation of the two methods of the increase of harmonic yield could be a useful tool for generation of strong short-wavelength radiation in different spectral regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-Photon Counting in Luminescent Analysis with Micro- and Millisecond Decay Times

Main methods of photon counting, as well as particularities in detecting micro- and millisecond decay times using a single-photon gated avalanche photodiode, are considered. The influence of the background radiation level on linearity of counting has been determined and the effect of photon superposition during asynchronous counting has been demonstrated. In addition, recommendations for the detection of long-living or delayed fluorescence and phosphorescence are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Finely Dispersed Micro- and Nano-Gold Recovery Using Thermomorphic Polymer with Diphenylphosphine

The article reports test data on adsorption and flotation characteristics of thermomorphic polymer joined with diphenylphosphine—TMPD. The test materials are natural pyrite and arsenopyrite, and models of gold-bearing sulfide minerals. Electron microscopy and X-ray structure analysis prove that reductive adsorption of gold at the surface of sulfide minerals from HAuCl{sub 4} solution allows modeling natural aggregates of sulfides and finely dispersed gold. UV spectrophotometry proves selective adsorption of TMPD at gold. Laser scanning microscopy shows connection of TMPD with micro- and nano-size gold on polished sections of pyrite and arsenopyrite. During monomineral flotation, joint use of TMPD and butyl xanthate at a ratio of 1:1 doubles the yield of gold-bearing sulfides and enables maximum recovery of gold minerals at the total consumption of reagents reduced by 30–50%. It is found that TMPD is selective relative to gold-bearing minerals and its combination with xanthate ensures a considerable increment in gold-bearing mineral recovery by flotation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Lepton mixing under the lepton charge nonconservation, neutrino masses and oscillations and the 'forbidden' decay Micro-Sign {sup -} {yields} e{sup -} + {gamma}

The lepton-charge (L{sub e}, L{sub {mu}}, L{sub {tau}}) nonconserving interaction leads to the mixing of the electron, muon, and tau neutrinos, which manifests itself in spatial oscillations of a neutrino beam, and also to the mixing of the electron, negative muon, and tau lepton, which, in particular, may be the cause of the 'forbidden' radiative decay of the negative muon into the electron and {gamma} quantum. Under the assumption that the nondiagonal elements of the mass matrices for neutrinos and ordinary leptons, connected with the lepton charge nonconservation, are the same, and by performing the joint analysis of the experimental data on neutrino oscillations and experimental restriction for the probability of the decay Micro-Sign {sup -} {yields} e{sup -} + {gamma} per unit time, the following estimate for the lower bound of neutrino mass has been obtained: m{sup ({nu})} > 1.5 eV/c{sup 2}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dynamics of local micro-breakdown in the Geiger mode of avalanche photodiodes

Mathematical modeling methods were used to study the dynamics of micro-breakdown development in structures of silicon avalanche photodiodes. The constructed model considers the locality of the avalanchexs multiplication region appearing during single photon absorption and the delay of the avalanchexs current spreading over the rear electrode of the diode. The calculations showed two different phases of transient process of the formation of the electrical signal, i.e., the rapid and slow ones due to current spreading and ordinary RC recharge, respectively. The load resistances required to implement the pulsed mode of operation of the structures of the avalanche photodiode were calculated for a series of actual diode capacitances and spreading resistances of the rear electrode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray diffraction analysis and scanning micro-Raman spectroscopy of structural irregularities and strains deep inside the multilayered InGaN/GaN heterostructure

High-resolution X-ray diffraction analysis and scanning confocal Raman spectroscopy are used to study the spatial distribution of strains in the In{sub x}Ga{sub 1-x}N/GaN layers and structural quality of these layers in a multilayered light-emitting diode structure produced by metal-organic chemical vapor deposition onto (0001)-oriented sapphire substrates. It is shown that elastic strains almost completely relax at the heterointerface between the thick GaN buffer layer and In{sub x}Ga{sub 1-x}N/GaN buffer superlattice. It is established that the GaN layers in the superlattice are in a stretched state, whereas the alloy layers are in a compressed state. In magnitude, the stretching strains in the GaN layers are lower than the compressive strains in the InGaN layers. It is shown that, as compared to the buffer layers, the layers of the superlattice contain a smaller number of dislocations and the distribution of dislocations is more randomly disordered. In micro-Raman studies on scanning through the thickness of the multilayered structure, direct evidence is obtained for the asymmetric gradient distributions of strains and crystal imperfections of the epitaxial nitride layers along the direction of growth. It is shown that the emission intensity of the In{sub x}Ga{sub 1-x}N quantum well is considerably (more than 30 times) higher than the emission intensity of the GaN barrier layers, suggesting the high efficiency of trapping of charge carriers by the quantum well.

36 MATERIALS SCIENCE↗

New Technology of High-Sensitivity Ferro/Piezoelectric Materials Based on Micro- and Nanostructured Hybrid Polymers

Fabrication of composites based on micro- and nanostructured hybrid polymers have been studied. A new technology for nanoparticle immobilization in the polymer matrix of the composite has been suggested. Its essence is to produce functional electronegative polymer segments in the polymer matrix, which are the main agents preventing nanoparticle mobilization in the polymer phase of a composite.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Micro-Scale Model for Oxygen Reduction on LSM-YSZ Cathode

In this study, a micro-scale model is developed to simulate the oxygen reduction on LSM-YSZ composite cathode. The model incorporates the effects of cathode microstructural properties on the local transport phenomena and electrochemistry inside the cathode. A detailed reaction mechanism is used in the model which has two parallel routes for oxygen conversion into oxide ions, namely two-phase boundary and three-phase boundary pathways. The model predicts field distributions of local thermodynamic values, over-potential, Faradaic current and other parameters relevant to cathode performance. Electrochemical impedance simulations are performed using the current model to analyze the contribution of various processes to the overall impedance.

30 DIRECT ENERGY CONVERSION↗

Perspective—Lithium Metal Nucleation and Growth on Conductive Substrates: A Multi-Scale Understanding from Atomistic, Nano-, Meso-, to Micro-Scales

Reversible lithium (Li) deposition and stripping on conductive substrates like copper is vital for long-life high-energy rechargeable Li batteries. The reversibility is believed hindered by solid electrolyte interphase (SEI) formation and Li dendritic growth. Via in situ, operando cryo-microscopy and molecular dynamics simulation, we discovered amorphous Li before a disorder-order phase transition to bcc phase. The kinetics plays a significant role in Li nucleation and morphology evolution. This perspective on Li nucleation and growth from atomistic to nano- (<20 nm), meso- (20–100 nm), and micro-scales (>100 nm) provides a practical guidance on regulating dense Li deposits reversibly for long life performance.

25 ENERGY STORAGE↗

Quantifying the Temperature Dependence of the Multi-Species, Multi-Reaction Model: Part II. Estimation of Entropy Coefficient for Meso-Carbon Micro-Bead Graphite

In Part 1 of this paper, the temperature impact on the Multi-Species, Multi Reaction (MSMR) model was studied. This was accomplished by acquiring data from slow rate lithiation and delithiation of a meso-carbon micro-bead (MCMB) graphite. Through this analysis, the temperature impact on the total fraction of available host sites in a particular MSMR gallery (X j ), the impact on the reference potential (U$^o_j$), and the impact on the parameter detailing the deviation from Nernstian behavior (ω j ) was determined. Here, the intercalation material is discussed, compared to traditional methods of acquiring the entropy coefficient, and comparison is made to previous mathematical estimates. Some of the challenges in using temperature dependent constant rate charge and discharge data as compared to the potentiodynamic entropy coefficient calculation method are also discussed, and a recommendation for future applications is proposed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗