Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

RESULTS FROM CAVITATION DAMAGE EXPERIMENTS WITH MERCURY SPALLATION TARGETS AT THE LANSCE WNR IN 2008

Damage assessment from proton beam induced cavitation experiments on mercury spallation targets done at the LANSCE WNR facility has been completed. The experiments investigated two key questions for the Spallation Neutron Source target, namely, how damage is affected by flow velocity in the SNS coolant channel geometry, and how damage scales with proton beam intensity at a given constant charge per pulse. With regard to the former question, prior in-beam experiments indicated that the coolant channel geometry with stagnant mercury was especially vulnerable to damage which might warrant a design change. Yet other results indicated a reduction in damage with the introduction of flow. Using more prototypic to the SNS, the 2008 experiment damage results show the channel is less vulnerable than the bulk mercury side of the vessel wall. They also show no benefit from increasing channel flow velocity beyond nominal SNS speeds. The second question probed a consensus belief that damage scales with beam intensity (protons per unit area) by a power law dependence with exponent of around 4. Results from a 2005 experiment did not support this power law dependence but some observations were inconsistent and unexplained. These latest results show weaker damage dependence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PRESSURE FLUCTUATION BEHAVIOR IN THE CRYOGENIC HYDROGEN SYSTEM CAUSED BY A 100 kW PROTON BEAM INJECTION

Supercritical hydrogen (1.5 MPa and around 20 K) has been selected as a moderator material for the intense spallation neutron source (JSNS) in J-PARC. The cryogenic hydrogen system provides the supercritical hydrogen for the moderators and removes the nuclear heating at the moderators, which is estimated to be 3.8 kW for a proton beam power of 1 MW. The pressure control system was designed to mitigate pressure fluctuation caused by suddenly turning a proton beam on and off, which is composed of a heater as an active controller for thermal compensation and an accumulator as a passive volume controller. A 109 kW proton beam was injected to the JSNS in December 2007. The pressure fluctuation behaviors were studied for the 109 kW proton beam operation. As soon as the proton beam was injected, the accumulator spontaneously started to constrict. The heater control succeeded in maintaining a constant heat load applied to the cryogenic hydrogen system. The pressure control system successfully reduced the pressure fluctuation within 6 kPa. It was confirmed that the pressure control system was effective.

43 PARTICLE ACCELERATORS↗

The First ASME Code Stamped Cryomodule at SNS

The first spare cryomodule for the Spallation Neutron Source (SNS) has been designed, fabricated, and tested by SNS personnel. The approach to design for this cryomodule was to hold critical design features identical to the original design such as bayonet positions, coupler positions, cold mass assembly, and overall footprint. However, this is the first SNS cryomodule that meets the pressure requirements put forth in the 10 CFR 851: Worker Safety and Health Program. The most significant difference is that Section VIII of the ASME Boiler and Pressure Vessel Code was applied to the vacuum vessel of this cryomodule. Applying the pressure code to the helium vessels within the cryomodule was considered. However, it was determined to be schedule prohibitive because it required a code case for materials that are not currently covered by the code. Good engineering practice was applied to the internal components to verify the quality and integrity of the entire cryomodule. The design of the cryomodule, fabrication effort, and cryogenic test results will be reported in this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of SNS Beamline Shielding Configurations using MCNPX Accelerated by ADVANTG

Shielding analyses for the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory pose significant computational challenges, including highly anisotropic high-energy sources, a combination of deep penetration shielding and an unshielded beamline, and a desire to obtain well-converged nearly global solutions for mapping of predicted radiation fields. The majority of these analyses have been performed using MCNPX with manually generated variance reduction parameters (source biasing and cell-based splitting and Russian roulette) that were largely based on the analyst's insight into the problem specifics. Development of the variance reduction parameters required extensive analyst time, and was often tailored to specific portions of the model phase space. We previously applied a developmental version of the ADVANTG code to an SNS beamline study to perform a hybrid deterministic/Monte Carlo analysis and showed that we could obtain nearly global Monte Carlo solutions with essentially uniform relative errors for mesh tallies that cover extensive portions of the model with typical voxel spacing of a few centimeters. The use of weight window maps and consistent biased sources produced using the FW-CADIS methodology in ADVANTG allowed us to obtain these solutions using substantially less computer time than the previous cell-based splitting approach. While those results were promising, the process of using the developmental version of ADVANTG was somewhat laborious, requiring user-developed Python scripts to drive much of the analysis sequence. In addition, limitations imposed by the size of weight-window files in MCNPX necessitated the use of relatively coarse spatial and energy discretization for the deterministic Denovo calculations that we used to generate the variance reduction parameters. We recently applied the production version of ADVANTG to this beamline analysis, which substantially streamlined the analysis process. We also tested importance function collapsing (in space and energy) capabilities in ADVANTG. These changes, along with the support for parallel Denovo calculations using the current version of ADVANTG, give us the capability to improve the fidelity of the deterministic portion of the hybrid analysis sequence, obtain improved weight-window maps, and reduce both the analyst and computational time required for the analysis process.

43 PARTICLE ACCELERATORS↗

SNS Injection Foil Experience

The Spallation Neutron Source comprises a 1 GeV, 1.4 MW linear accelerator followed by an accumulator ring and a liquid mercury target. To manage the beam loss caused by the H0 excited states created during the H charge exchange injection into the accumulator ring, the stripper foil is located inside one of the chicane dipoles. This has some interesting consequences that were not fully appreciated until the beam power reached about 840 kW. One consequence was sudden failure of the stripper foil system due to convoy electrons stripped from the incoming H beam, which circled around to strike the foil bracket and cause bracket failure. Another consequence is that convoy electrons can reflect back up from the electron catcher and strike the foil and bracket. An additional contributor to foil system failure is vacuum breakdown due to the charge developed on the foil by secondary electron emission. In this paper we will detail these and other interesting failure mechanisms, and describe the improvements we have made to mitigate them.

43 PARTICLE ACCELERATORS↗

The IPNS second harmonic RF upgrade.

The intense pulsed neutron source (IPNS) rapid cycling synchrotron (RCS) is used to accelerate protons from 50 MeV to 450 MeV, at a repetition rate of 30 Hz. The original ring design included two identical rf systems, each consisting of an accelerating cavity, cavity bias supply, power amplifiers and low-level analog electronics. The original cavities are located 180 degrees apart in the ring and provide a total peak accelerating voltage of {approx}21 kV over the 2.21-MHz to 5.14-MHz revolution frequency sweep. A third rf system has been constructed and installed in the RCS. The third rf system is capable of operating at the fundamental revolution frequency for the entire acceleration cycle, providing an additional peak accelerating voltage of up to {approx}11 kV, or at the second harmonic of the revolution frequency for the first {approx}4 ms of the acceleration cycle, providing an additional peak voltage of up to {approx}11 kV for bunch shape control. We describe here the hardware implementation and operation to date of the third rf cavity in the second harmonic mode.

43 PARTICLE ACCELERATORS↗

Analysis of Archived Prompt Pulse Data from the SNS HYSPEC Instrument - Paper 68

This is an investigation by the Neutronics team at the Spallation Neutron Source (SNS) to understand the Hybrid-Spectrometer (HYSPEC) pulsed background problem and ultimately lend qualitative insight toward future shielding considerations. The archived user data from HYSPEC was accessed and manipulated via Mantidplot. Algorithms have been written to identify the background feature, or 'prompt pulse', in these data files and how it fluctuates as a function of time. Correlations between these fluctuations and external/internal physical changes are being analyzed in an attempt to model the behavior of the pulsed background in the SNS target building. Understanding the contributing factors of the background may help mitigate current effects as well as potential effects in future target facilities. This information is initially being used to indicate how the local shielding arrangements and general geometry of the target building and/or greater facility affect the prompt pulse as received by HYSPEC. Additionally, this better understanding of the pulsed background will continue to help our team lend increasingly accurate advice concerning future shielding improvements, minimization of prompt pulse features in the HYSPEC data, other inelastic instruments in the current target facility and suggestions for second target station planning. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RF Distribution System for High Power Test of the SNS Cryomodule

A four-way waveguide RF power distribution system for testing the Spallation Neutron Source (SNS) multi-cavity cryomodule to investigate the collective behavior has been developed. A single klystron operating at 805MHz for 1.3 msec at 60Hz powers the 4-way waveguide splitter to deliver up to 400 kW to individual cavities. Each cavity is fed through a combination of waveguide splitters and vector modulators (VM) to provide independent magnitude and phase controls. The waveguide vector modulator consists of two quadrature hybrids and two motorized waveguide phase shifters. The phase shifters and the assembled waveguide vector modulators were individually tested and characterized for low power and high RF power in the SNS RF test facility. Precise calibrations of magnitude and phase were performed to generate the look up tables (LUTs) to provide operational references during the cryomodule test. An I-Q demodulator module was developed and utilized to measure relative phases in pulsed high RF power operation. PLC units were developed for mechanical control of the phase shifters. Initial low/high power measurements were made using LabVIEW. An operation algorithm has been implemented into EPICS control for the cryomodule test stand.

43 PARTICLE ACCELERATORS↗

High Purity Americium-241 for Fuel Cycle R&D Program

Previously the U.S. Department of Energy released Am-241 for various applications such as smoke detectors and Am-Be neutron sources for oil wells. At this date there is a shortage of usable, higher purity Am-241 in metal and oxide form available in the United States. Recently, the limited source of Am-241 has been from Russia with production being contracted to existing customers. The shortage has resulted in the price per gram rising dramatically over the last few years. DOE-NE currently has need for high purity Am-241 metal and oxide to fabricate fuel pellets for reactor testing in the Fuel Cycle R&D program. All the available high purity americium has been gathered from within the DOE system of laboratories. However, this is only a fraction of the projected needs of FCRD over the next 10 years. Therefore, FCR&D has proposed extraction and purification concepts to extract Am-241 from a mixed AmO2-PuO2 feedstock stored at the Savannah River Site. The most simple extraction system is based upon high temperature reduction using lanthanum metal with concurrent evaporation and condensation to produce high purity Am metal. Metallic americium has over a four order of magnitude higher vapor pressure than plutonium. Results from small-scale reduction experiments are presented. These results confirm thermodynamic predictions that at 1000 deg C metallic lanthanum reduces both PuO2 and AmO2. Faster kinetics are expected for temperatures up to about 1500 deg C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PRESSURE DROP EVALUATION OF THE HYDROGEN CIRCULATION SYSTEM FOR JSNS

In J-PARC, an intense spallation neutron source (JSNS) driven by a proton beam of 1 MW has selected supercritical hydrogen with a temperature of around 20 K and the pressure of 1.5 MPa as a moderator material. A hydrogen-circulation system, which consists of two pumps, an ortho-para hydrogen converter, a heater, an accumulator and a helium-hydrogen heat exchanger, has been designed to provide supercritical hydrogen to the moderators and remove the nuclear heating there. A hydrogen-circulation system is cooled through the heat exchanger by a helium refrigerator with the refrigeration power of 6.45 kW at 15.5 K. It is important for the cooling design of the hydrogen-circulation system to understand the pressure drops through the equipments. In this work, the pressure drop through each component was analyzed by using a CFD code, STAR-CD. The correlation of the pressure drops through the components that can describe the analytical results within 14% differences has been derived. It is confirmed that the pressure drop in the hydrogen circulation system would be estimated to be 37 kPa for the circulation flow rate of 160 g/s by using the correlations derived here, and is sufficiently lower than the allowable pump head of 100 kPa.

42 ENGINEERING↗

Impact of post-irradiation annealing on mechanical performance of irradiated 718 alloy

Here, the effect of post-irradiation annealing on solution-annealed 718 alloy was investigated using advanced mechanical testing, fractography, scanning electron microscopy, and transmission electron microscopy. Specimens were extracted from a proton beam window operated at the Spallation Neutron Source, irradiated with 940 MeV protons to a maximum dose of approximately 9.7 displacements per atom (dpa) at a calculated temperature not exceeding 110 °C while in service. Helium and hydrogen concentrations reached about 1700 and 6900 atomic parts per million (appm), respectively. Despite irradiation and high tensile strength (yield stress over 1 GPa), the material exhibited significant ductility. Annealing at 500 °C, 700 °C, and 900 °C for 30 min resulted in an appreciable decrease in yield strength and an increase in ductility for annealing treatments at 500 °C and 900 °C relative to the strength and ductility of the as-irradiated material. The presence of helium and hydrogen led to cavity formation and cleavage-like brittle features on fractured surfaces; however, high-magnification imaging revealed the presence of small-scale ductile dimples, indicating that the fracture mechanism remained mixed. The annealed specimens retained total elongation levels of 14–33 %, and there was no sudden drop in ductility after heat treatments. The ductility level in the irradiated and annealed material is notable despite the presence of helium and hydrogen.

36 MATERIALS SCIENCE↗

Operational status of the Los Alamos neutron science center (LANSCE)

The Los Alamos Neutron Science Center (LANSCE) accelerator and beam delivery complex generates the proton beams that serve three neutron production sources; the thermal and cold source for the Manuel Lujan Jr. Neutron Scattering Center, the Weapons Neutron Research (WNR) high-energy neutron source, and a pulsed Ultra-Cold Neutron Source. These three sources are the foundation of strong and productive multi-disciplinary research programs that serve a diverse and robust user community. The facility also provides multiplexed beams for the production of medical radioisotopes and proton radiography of dynamic events. The recent operating history of these sources will be reviewed and plans for performance improvement will be discussed, together with the underlying drivers for the proposed LANSCE Refurbishment project. The details of this latter project are presented in a separate contribution.

42 ENGINEERING↗

Early Fault Detection in Particle Accelerator Power Electronics Using Ensemble Learning

Early fault detection and fault prognosis are crucial to ensure efficient and safe operations of complex engineering systems such as the Spallation Neutron Source (SNS) and its power electronics (high voltage converter modulators). Following an advanced experimental facility setup that mimics SNS operating conditions, the authors successfully conducted 21 early fault detection experiments, where fault precursors are introduced in the system to a degree enough to cause degradation in the waveform signals, but not enough to reach a real fault. Nine different machine learning techniques based on ensemble trees, convolutional neural networks, support vector machines, and hierarchical voting ensembles are proposed to detect the fault precursors. Although all 9 models have shown a perfect and identical performance during the training and testing phase, the performance of most models has decreased in the next test phase once they got exposed to realworld data from the 21 experiments. The hierarchical voting ensemble, which features multiple layers of diverse models, maintains a distinguished performance in early detection of the fault precursors with 95% success rate (20/21 tests), followed by adaboost and extremely randomized trees with 52% and 48% success rates, respectively. The support vector machine models were the worst with only 24% success rate (5/21 tests). The study concluded that a successful implementation of machine learning in the SNS or particle accelerator power systems would require a major upgrade in the controller and the data acquisition system to facilitate streaming and handling big data for the machine learning models. In addition, this study shows that the best performing models were diverse and based on the ensemble concept to reduce the bias and hyperparameter sensitivity of individual models.

43 PARTICLE ACCELERATORS↗

Comparative analysis of the possibility of applying low-melting metals with the capillary-porous system in tokamak conditions

The use of capillary-porous systems (CPSs) with liquid Li, Ga, and Sn is considered as an alternative for solving the problem of creating plasma-facing elements (PFEs) of the fusion neutron source (FNS) and the DEMO-type reactor. The main advantages of CPSs with liquid metal compared with hard materials are their stability with respect to the degradation of properties in tokamak conditions and capability of surface self-restoration. The evaluation of applicability of liquid metals is performed on the basis of the analysis of their physical and chemical properties, the interaction with the tokamak plasma, and constructive and process features of in-vessel elements with CPSs implementing the application of these metals in a tokamak. It is shown that the upper limit of the PFE working temperature for all low-melting metals under consideration lies in the range of 550–600°Ð¡. The decisive factor for PFEs with Li is the limitation on the admissible atomic flux into plasma, while for those with Ga and Sn it is the corrosion resistance of construction materials. The upper limit of thermal loads in the steady-state operating mode for the considered promising PFE design with the use of Li, Ga, and Sn is close to 18–20 MW/m{sup 2}. It is seen from the analysis that the use of metals with a low equilibrium vapor pressure of (Ga, Sn) gives no gain in extension of the region of admissible working temperatures of PFEs. However, with respect to the totality of properties, the possibility of implementing the self-restoration and stabilization effect of the liquid surface, the influence on the plasma discharge parameters, and the ability to protect the PFE surface in conditions of plasma perturbations and disruption, lithium is the most attractive liquid metal to create CPS-based PFEs for the tokamak.

36 MATERIALS SCIENCE↗

Measurement of the -3 keV resonance in the {sup 13}C({alpha},n){sup 16}O reaction and its influence on the synthesis of s-process nuclei

The {sup 13}C({alpha},n){sup 16}O reaction is the neutron source for the main component of the s-process, responsible of the production of most nuclei in the mass range 90 < A < 204. It is active inside the helium-burning shell in asymptotic giant branch stars, at temperatures < 10{sup 8} K, corresponding to an energy interval where the {sup 13}C({alpha},n){sup 16}O is effective of 140 - 230 keV. In this region, the astrophysical S(E)-factor is dominated by the -3 keV sub-threshold resonance due to the 6.356 MeV level in {sup 17}O, giving rise to a steep increase of the S-factor. Notwithstanding that it plays a crucial role in astrophysics, no direct measurements exist. Therefore, we have applied the Trojan Horse Method (THM) to the {sup 13}C({sup 6}Li,n{sup 16}O)d quasi-free reaction to achieve an experimental estimate of such contribution. For the first time, the ANC for the 6.356 MeV level has been deduced through the THM as well as the n-partial width, allowing to attain an unprecedented accuracy in the {sup 13}C({alpha},n){sup 16}O study. Though a larger ANC for the 6.356 MeV level is measured, our experimental S(E) factor agrees with the most recent extrapolation in the literature in the 140 - 230 keV energy interval, the accuracy being greatly enhanced thanks to this innovative approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Compact deuterium-tritium neutron generator using a novel field ionization source

Active interrogation using neutrons is an effective method for detecting shielded nuclear material. A lightweight, lunch-box-sized, battery-operated neutron source would enable new concepts of operation in the field. We have developed at-scale components for a highly portable, completely self-contained, pulsed Deuterium-Tritium (DT) neutron source producing 14 MeV neutrons with average yields of 10{sup 7} n/s. A gated, field ionization ion source using etched electrodes has been developed that produces pulsed ion currents up to 500 nA. A compact Cockcroft-Walton high voltage source is used to accelerate deuterons into a metal hydride target for neutron production. The results of full scale DT tests using the field ionization source are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of a Commercial Scale Accelerator Driven Subcritical Aqueous Assembly

SHINE Medical Technologies is working towards producing a reliable, domestic supply of medical isotopes, including molybdenum-99 (Mo-99), xenon-133, and iodine 131, without using highly enriched uranium. Approximately 88% of Mo-99 decays to technetium-99m, which is the most widely used medical isotope in the world, accounting for approximately 80% of all nuclear medicine procedures. A novel aqueous, subcritical nuclear assembly has been designed by SHINE Medical Technologies. The assembly can produce medical radioisotopes in significant quantities for U.S. and foreign needs. The assembly produces isotopes without using a reactor, instead using a fusion-based neutron source coupled to a fission-based aqueous assembly. The subcritical nature of the aqueous assembly has safety and licensing benefits, including the elimination of the reactor control system and elimination of high level waste. SHINE plans to construct eight subcritical assemblies with a plant capacity of greater than 3000 6-day Curies, which is more than one-quarter of the world's Mo-99 requirements. From a nuclear design standpoint, the aqueous subcritical assembly needs to be able to generate sufficient fission power to meet the production capacity requirements while remaining subcritical at all times with an acceptable margin. To address these conflicting design goals, a simple nuclear design and reactivity control philosophy has been developed that allows for high power operation with a high degree of safety. A fusion-driven subcritical fission assembly has been designed by SHINE Medical Technologies to provide a reliable, domestic supply of medical isotopes. Nuclear models have been created and show that the assembly can be started up, operated, and shutdown in a safe manner without active reactivity control systems. A unique reactivity control strategy allows SHINE to operate the aqueous subcritical assembly at much higher power levels than would otherwise be practical, while still retaining the benefits of subcritical operation and avoiding the need for complex subcritical measurement techniques. Based on the current design, the subcritical target is capable of generating significant fission power (on the order of 100 kW) when being driven by a simple, low-cost deuterium-tritium accelerator, enabling the SHINE facility to supply over one-fourth of the worldwide demand of Mo- 99. SHINE has recently been issued a construction permit by the U.S. Nuclear Regulatory Commission to build the commercial facility in Janesville, WI, with eight subcritical assemblies and the associated production equipment. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

International MNSR Training Center

Plans for the conversion of the Chinese origin miniature neutron source reactors (MNSRs) to low-enriched uranium (LEU), and the return of the high- enriched uranium (HEU) core to China, were initiated in February 2011 when an international MNSR Working Group (WG) was established to coordinate these activities. Based on a Ghana Atomic Energy Commission (GAEC) decision, the MNSR core at the GHARR-1 facility was selected for pilot shipment. Working on the preparation of the HEU MNSR materials’ removal from the GHARR-1 facility as a training tool, a mock-up MNSR vessel was built for operator training. Experiencing the usefulness of the mock-up vessel in operator training in the Ghana case has since been developed further into a full-scale training facility, named the International MNSR Training Center (IMTC), which is now available for training operators from MNSR operating countries. The main objective of this Book is to document the IMTC as a full-scale MNSR training facility in operator training for HEU MNSR core discharge and packaging. The goal is to describe the IMTC in its full complexity — that is: (1) to present the IMTC’s buildings with its internal and outer areas; (2) to provide a full listing of the installed equipment, as well as a functional description, available at the IMTC site; (3) to introduce the training materials, tutorials, and training program; and (4) to present the training sessions and Dry-run demonstration of the recently completed NIRR-1 operator training, with their experiences and lessons-learned included. This Book serves as a kind of user manual for the IMTC, which contains all of the information to launch training courses at the site at any time. The target audience for this Book is the MNSR community, especially MNSR operators and regulators who are facing HEU-LEU core conversion and HEU material transportation, who require operator training to carry out their jobs safely and professionally.

99 - GENERAL AND MISCELLANEOUS↗