Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Evaluation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

MOOSE ProbML: Parallelizable Probabilistic Machine Learning and Uncertainty Quantification Capabilities

The Multiphysics Object Oriented Simulation Environment (MOOSE) is a widely used open- source finite element software for performing multiphysics multiscale simulations in a massively parallel fashion. Recently, the computational team at Idaho National Laboratory (INL) has implemented Probabilistic Machine Learning (ProbML) capabilities in MOOSE—in a parallelized fashion—and enable active learning with large-scale computational models for tasks such as surrogate model development, scale bridging, forward/inverse uncertainty quantification (UQ), Bayesian optimization, etc. This presentation summarizes these developments in MOOSE along with demonstrations on several real applications relevant to nuclear energy. At the fundamental level, samplers like Monte Carlo/Latin Hypercube, variance reduction, parallelized Markov Chain Monte Carlo (MCMC) support uncertainty propagation in both forward and inverse settings. These samplers can be integrated with the Gaussian processes (GP) suite in MOOSE, which offer several variants like scalar GPs, multi-output GPs, and deep GPs, to enable active learning. These GPs can be tuned using gradient-based optimization methods like Adam and its variants or gradient-free methods like the elliptical slice sampler (a variant of MCMC adept under Gaussian settings) for more complex covariance kernels or likelihoods whose gradient computations can be cumbersome. A variety of batch acquisition functions permit parallelized evaluation of the computational model and support different learning objectives with high efficiency like Bayesian inference, global surrogate development, optimization, etc. Furthermore, libtorch integration supports training, evaluation, and re-training of neural networks and other complex machine learning models in active learning settings. The impacts of these developments are shown on several real applications: (1) nuclear fuel inverse UQ and model inadequacy assessment using the Kennedy O’Hagan framework; (2) uncertainty aware surrogate modeling for additive manufacturing to predict field quantities; (3) nuclear reactor rare events analysis; and (4) complex fluid flow prediction using a global surrogate with quantified prediction uncertainty. Finally, the outlook of MOOSE ProbML is discussed for both outer-loop and inner-loop computations in the broad view to accelerate fuels and materials qualification, address gaps in knowledge and data, and assess new reactor/fuel systems.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analyzing power and cross section distributions of the {sup 12}C(p,p{alpha}){sup 8}Be cluster knockout reaction at an incident energy of 100 MeV

The (p,p{alpha}) reaction on {sup 12}C was investigated experimentally using polarized incident protons of 100 MeV. The scattered proton and {alpha} particle, from the knockout reaction, were detected in coincidence. Coincident data, which were obtained at ten quasifree angle pairs for proton angles ranging from 25 deg. to 110 deg., were analyzed in terms of the distorted-wave impulse approximation (DWIA). Calculated energy-sharing cross section and analyzing power distributions reproduce the data reasonably well, indicating that a quasifree knockout mechanism dominates the reaction. Since measurements of analyzing powers were made, spin-orbit distortions were included in the DWIA calculations. The effects of this were found to be very small near zero recoil momentum and did not destroy the validity of the factorization approximation where the two-body p-{alpha} cross section enters as a multiplicative factor in the three-body (p,p{alpha}) cross section expression. Spectroscopic factors derived from the data are consistent with theoretical predictions. Analyzing power data also follow the trend of free p-{sup 4}He scattering data, and comparisons with DWIA predictions are in reasonable agreement. Because the two-body interaction response between the projectile and the {alpha} cluster was found to resemble the scattering of protons from a free {alpha} particle to a remarkable degree, the present results would strongly imply the existence of preformed {alpha} clusters in {sup 12}C.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-595: Output Factor Calculation for a Uniform Scanning Proton Therapy System

Purpose: To develop an analytical model that predicts dose output factors for patient treatment fields in a uniform scanning proton therapy system. Methods: A model to predict output factors for patient specific treatment fields was produced based on the methods developed by Kooy et al. (2003). The Kooy model predicts the output factor based on the ratio of the entrance dose under calibration conditions to that for a given range and modulation corrected for the inverse square effect. Field specific output factors were plotted as a function of a single parameter r, where r = (Range-Modulation)/Modulation. The model targeted user range 1 sub-span 3 through user range 2 sup-span 2 of the IBA uniform scanning proton therapy system. The data set included points measured using the 10 cm and 18 cm snout sizes to eliminate stem effects on the monitor unit chambers. The data was fit using equation 15 from Kooy et al. (2003), and the resulting model was tested against measurements that were not included in the original data set. Results: For the range and sub span investigated, 120 data points were tested against the model prediction. The model predicted the output factor within 2% for 96% of the points tested and within 2.5% for 99% of the points tested. All points were within 3% of the predicted values. Conclusion: Monitor units for patient treatment fields with proton ranges that fall within the tested interval can be predicted using a model based on the methods developed at MGH. With further evaluation, it will be possible to model all user ranges and sub-spans of the IBA system. Further testing is also needed to predict output factors using a 25 cm snout which introduces variable scanning pattern sizes and stem effects on the monitor unit chambers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Alternative Method for Performing As-Built, As-Irradiated Neutronics Analyses

Neutronics analyses have been used to assist in the design, development, and qualification of miniature fuel (MiniFuel) experiments irradiated in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) since their conception almost a decade ago. In recent years, upon completion of a MiniFuel target’s irradiation, neutronics analyses that reflect the as-built, as-irradiated conditions of an experiment have also been performed to validate postirradiation examination (PIE) efforts. Several radiation transport and depletion/activation software wrapper programs have been developed to increase the fidelity of these calculations; at ORNL, a program called HFIRCON is the primary software method employed. However, the utilization of these wrapper programs comes at a cost. To produce accurate results, the radiation transport portion of these analyses requires significant time and resources to execute. Therefore, this report discusses an alternative methodology for calculating some of the desired output for PIE validation—specifically, the output used in evaluating the experiment’s fuel burnup—without complete reliance on ORNL’s wrapper program. The alternative method is not a new software but rather a procedure for utilizing the depletion/activation software, SCALE, in conjunction with limited input data and reasonable assumptions to bypass most of the radiation transport calculations and thereby reduce the time required for the completion of a standard analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) for engineering flow measurements

Increasingly, fully 3D experimental measurements of flow in complex engineering geometries are required to validate computational fluid dynamics models that support and inform reactor design and licensing. One barrier to such measurements is the complexity of typical reactor components and subsequent lack of optical access in these systems. To overcome this, the deployment of coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) is explored for flow measurement in reactor thermal hydraulic components and model (scaled) systems. Through this methodology, fully 3D flow information (via PEPT) and detailed internal geometry (via CT) are captured in opaque systems such as pipes, rod bundles, packed beds, etc. The reconstructed flow field and geometry can then be overlain to reveal detailed flow features around internal structures within a given test section. This is enabled through the use of a combined preclinical PET/CT scanner with overlapping PET and CT fields of view. Such measurements are useful for characterizing flow inside such intricate nuclear thermal hydraulic components as core geometries and heat exchangers, among others, and providing valuable 3D validation data for CFD models. In this work, basic tests of this 3D flow/geometry mapping are presented, and the implications of such measurements are discussed. Further, preliminary measurements are made with both point sources and flow in a simple pipe flow geometry to evaluate the capabilities of this technique. PEPT and CT features are coregistered with up to 0.1 mm precision, and pipe flow mean velocity and Reynolds stresses are reconstructed with similar accuracy to previous PEPT demonstrations. The utility of PEPT/CT is shown herein, and suggestions for future measurements are made.

3D flow measurement↗

First hydrogen operation of NIO1: Characterization of the source plasma by means of an optical emission spectroscopy diagnostic

NIO1 (Negative Ion Optimization 1) is a compact and flexible radio frequency H{sup −} ion source, developed by Consorzio RFX and INFN-LNL. The aim of the experimentation on NIO1 is the optimization of both the production of negative ions and their extraction and beam optics. In the initial phase of its commissioning, NIO1 was operated with nitrogen, but now the source is regularly operated also with hydrogen. To evaluate the source performances, an optical emission spectroscopy diagnostic was installed. The system includes a low resolution spectrometer in the spectral range of 300-850 nm and a high resolution (50 pm) one, to study, respectively, the atomic and the molecular emissions in the visible range. The spectroscopic data have been interpreted also by means of a collisional-radiative model developed at IPP Garching. Besides the diagnostic hardware and the data analysis methods, the paper presents the first plasma measurements across a transition to the full H mode, in a hydrogen discharge. The characteristic signatures of this transition in the plasma parameters are described, in particular, the sudden increase of the light emitted from the plasma above a certain power threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remaining Useful Strength (RUS) Prediction of SiCf-SiCm Composite Materials Using Deep Learning and Acoustic Emission

Prognosis techniques for prediction of remaining useful life (RUL) are of crucial importance to the management of complex systems for they can lead to appropriate maintenance interventions and improvements in reliability. While various data-driven methods have been introduced to predict the remaining useful life (RUL) of machinery systems or batteries, no research has been reported on the remaining useful strength (RUS) prediction of silicon carbide fiber reinforced silicon carbide matrix (SiCf-SiCm) materials with pivotal role in its potential usage as a structural material in nuclear reactors and turbine engines. Knowledge of its degradation process is of the utmost importance to the manufacturers. For this purpose, two approaches based on the machine-learning techniques of random-forest (RF) and convolutional neural network (CNN) are proposed to predict the RUS of SiCf-SiCm using only acoustic emission (AE) signals generated during the material’s stress applying process. Experimental results show that the CNN models achieved better predictive performance than the RF models but the latter with expert-engineered features achieves better prediction for AE signals in the early stage of degradation. Additionally, our results demonstrate that both models can correctly predict the SiCf-SiCm RUS as evaluated by our robust testing method from which the best average root mean square error (RMSE) and Pearson correlation coefficient of 3.55 ksi units and 0.85 were obtained.

36 MATERIALS SCIENCE↗

Multipinhole SPECT helical scan parameters and imaging volume

Purpose: The authors developed SPECT imaging capability on an animal PET scanner using a multiple-pinhole collimator and step-and-shoot helical data acquisition protocols. The objective of this work was to determine the preferred helical scan parameters, i.e., the angular and axial step sizes, and the imaging volume, that provide optimal imaging performance. Methods: The authors studied nine helical scan protocols formed by permuting three rotational and three axial step sizes. These step sizes were chosen around the reference values analytically calculated from the estimated spatial resolution of the SPECT system and the Nyquist sampling theorem. The nine helical protocols were evaluated by two figures-of-merit: the sampling completeness percentage (SCP) and the root-mean-square (RMS) resolution. SCP was an analytically calculated numerical index based on projection sampling. RMS resolution was derived from the reconstructed images of a sphere-grid phantom. Results: The RMS resolution results show that (1) the start and end pinhole planes of the helical scheme determine the axial extent of the effective field of view (EFOV), and (2) the diameter of the transverse EFOV is adequately calculated from the geometry of the pinhole opening, since the peripheral region beyond EFOV would introduce projection multiplexing and consequent effects. The RMS resolution results of the nine helical scan schemes show optimal resolution is achieved when the axial step size is the half, and the angular step size is about twice the corresponding values derived from the Nyquist theorem. The SCP results agree in general with that of RMS resolution but are less critical in assessing the effects of helical parameters and EFOV. Conclusions: The authors quantitatively validated the effective FOV of multiple pinhole helical scan protocols and proposed a simple method to calculate optimal helical scan parameters.

60 APPLIED LIFE SCIENCES↗

Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons

Purpose: The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides ({sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Methods: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source {beta}{sup -}, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the {sup 192}Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Results: Electronic equilibrium within 1% is reached for {sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for {sup 60}Co and {sup 192}Ir, respectively. Electron emissions become important (i.e., >0.5%) within 3.3 mm of {sup 60}Co and 1.7 mm of {sup 192}Ir sources, yet are negligible over all distances for {sup 137}Cs and {sup 169}Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Conclusions: Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

61 RADIATION PROTECTION AND DOSIMETRY↗

Production of NBL PO plutonium isotopic standards CRM 136A, CRM 137A, and CRM 138A

Lawrence Livermore National Laboratory (LLNL) produced approximately 1 mg units of purified Pu from the parent New Brunswick Laboratory (NBL) certified reference materials (CRM) 137, 136 and 138 isotopic standards for the NBL Program Office (NBL PO) as detailed in the revised project plan. As stated in the plan, three representative units of each material were dispensed at the same time to be characterized at LLNL and provide informational values for the quantity of Pu and progeny nuclides in each unit. NBL PO intends to collect and evaluate isotopic measurement data from multiple laboratories and certify these materials as new isotopic standards C137A, C136A, and C138A, respectively. Soon after production eleven units of each analytical standard were shipped to other analytical laboratories for the certification effort, and 121, 119, and 119 units of C137A, C136A and C138A, respectively were shipped to Mickey Finch at Y12 NBL distribution center in November 2024 (30-gallon drum, TID 003777 PRL 7000005043). Residual purified Pu from the effort is being stored indefinitely in B332 at LLNL. Detailed methods can be found in the production plan, and this report describes and documents aspects of the production effort that are not in or were modified from the original production plan.

and nuclear chemistry↗

Genetic approaches to the conservation of migratory bats: a study of the eastern red bat ( Lasiurus borealis )

Documented fatalities of bats at wind turbines have raised serious concerns about the future impacts of increased wind power development on populations of migratory bat species. However, for most bat species we have no knowledge of the size of populations and their demographic trends, the degree of structuring into discrete subpopulations, and whether different subpopulations use spatially segregated migratory routes. Here, we utilize genetic data from eastern red bats (Lasiurus borealis), one of the species most highly affected by wind power development in North America, to (1) evaluate patterns of population structure across the landscape, (2) estimate effective population size (N e ), and (3) assess signals of growth or decline in population size. Using data on both nuclear and mitochondrial DNA variation, we demonstrate that this species forms a single, panmictic population across their range with no evidence for the historical use of divergent migratory pathways by any portion of the population. Further, using coalescent estimates we estimate that the effective size of this population is in the hundreds of thousands to millions of individuals. The high levels of gene flow and connectivity across the population of eastern red bats indicate that monitoring and management of eastern red bats must integrate information across the range of this species.

Effective population size↗

Self-Management of Patient Body Position, Pose, and Motion Using Wide-Field, Real-Time Optical Measurement Feedback: Results of a Volunteer Study

Purpose: We present the results of a clinical feasibility study, performed in 10 healthy volunteers undergoing a simulated treatment over 3 sessions, to investigate the use of a wide-field visual feedback technique intended to help patients control their pose while reducing motion during radiation therapy treatment. Methods and Materials: An optical surface sensor is used to capture wide-area measurements of a subject's body surface with visualizations of these data displayed back to them in real time. In this study we hypothesize that this active feedback mechanism will enable patients to control their motion and help them maintain their setup pose and position. A capability hierarchy of 3 different level-of-detail abstractions of the measured surface data is systematically compared. Results: Use of the device enabled volunteers to increase their conformance to a reference surface, as measured by decreased variability across their body surfaces. The use of visual feedback also enabled volunteers to reduce their respiratory motion amplitude to 1.7 ± 0.6 mm compared with 2.7 ± 1.4 mm without visual feedback. Conclusions: The use of live feedback of their optically measured body surfaces enabled a set of volunteers to better manage their pose and motion when compared with free breathing. The method is suitable to be taken forward to patient studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving Ligand Geometry in Protein Data Bank Structures Computationally

Information about the three‐dimensional structures of complex biological molecules is an indispensable research tool for many fields of study, including biology, chemistry, pharmacology, and computer science. The Protein Data Bank (PDB) is an public digital archive providing access to structures of nucleic acids, proteins, and large macromolecular machines determined experimentally by X‐ray crystallography, nuclear magnetic resonance (NMR) spectroscopy, and 3‐dimensional electron microscopy (3DEM). PDB structures undergo validation for structural plausibility upon their deposition into the PDB using the program Mogul, which cross references each deposited structure against similar data in the Cambridge Structural Database (CSD). Ligands associated with PDB structures are a common source of structural inaccuracy. In this study, a programmatic pipeline was developed to determine if ligand geometric accuracy could be improved using known computational tools. Ligands with dubious geometry were identified through a Python mining code. A sample set of the identified structures was remodeled into minimum energy conformations using the molecular dynamics program AMBER and then fit to the original experimental density maps using the molecular modeling program Coot. The refined models were compared to the original models in the PDB as well as to similar structures in the CSD using the deposition statistical validation server. Preliminary results suggest that the pipeline effectively identifies and improves ligand structures that possess inaccurate geometry. This method can be used to evaluate and improve the accuracy of specific ligands in structures both archived and pending deposition. Support or Funding Information This work was supported by an NSF REU and the RCSB PDB [NSF (DBI‐1338415), NIH, and DOE.] This abstract is from the Experimental Biology 2019 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .

Miller, Beck↗

Three-body decays and R-matrix analyses

The R-matrix simulation of three-body decays is investigated as function of available Q value and the energy and width of the intermediate two-body resonance. We use three {alpha}-decaying unnatural parity states of {sup 12}C for illustration. The energy distributions are shown to be sensitive to the parameters when the two-body energy is significantly smaller than Q and the width is smaller than about 0.5 MeV. The sequential decay inherent in the R-matrix formalism can then be distinguished from direct decay. We provide conditions for the validity of R-matrix analyses. We compare with full three-body computations of the same energy distributions where we also attempt to distinguish between sequential and direct decays. The results give a good reproduction of available experimental data and are consistent with the conclusions from R-matrix analyses. Nodes in the momentum distributions arise from angular momentum and parity conservation. Combined with symmetry requirements this constrains the momentum distributions significantly in some cases. Effects of interactions and decay mechanisms can only be seen in the remaining behavior as, e.g., additional nodes related to nodes in the coordinate wave function at large distance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of Zirconium Redistribution in BISON EBR-II Models Using FIPD and IMIS Databases with Experimental Post Irradiation Examination

Metallic fuels have seen increased interest for future sodium fast reactors due to their material properties: high thermal conductivities and advantageous neutronic properties allow for greater fission densities. One drawback to typical metallic fuels is zirconium redistribution, which impacts this advantageous material and its neutronic properties. Unfortunately, the processes behind zirconium migration behavior are understood using first principles, so before these fuels are implemented in future fast reactors, characterization and fuel qualification regimes must be completed. These activities can be supported through the use of robust modeling using the most accurate empirical models currently available to fuel researchers around the world. The tool that allows researchers to model this complex coupled thermo-mechanical behavior and nuclear properties is BISON. Additionally, BISON model parameters need to be compared against PIE measurements. The current work utilizes two fuel pins from EBR-II experiment X441 to optimize various model parameters, including porosity correction factor, thermal conductivity, phase transition temperature, and diffusion coefficient multipliers, before implementing the final model for seven fuel pins with differing characteristics. To properly evaluate the BISON simulations, the results are compared to PIE metallography data for each fuel pin, to ensure the zirconium redistribution is properly reflected in the simulation results. Six out of seven analyzed fuel pins demonstrate good agreement between the metallography images and BISON results, showing alignment of the Zr-rich, Zr-depleted, and moderately Zr-enriched zones at various axial heights along the fuel pins. Further work is needed to refine the model parameters for general pin use.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Field Trial of LANL On-Line Advanced Enrichment Monitor for UF6 GCEP

The outline of this presentation is: (1) Technology basis of on-line enrichment monitoring; (2) Timescale of trial; (3) Description of installed equipment; (4) Photographs; (5) Results; (6) Possible further development; and (7) Conclusions. Summary of the good things about the Advanced Enrichment Monitor (AEM) performance is: (1) High accuracy - normally better than 1% relative, (2) Active system as accurate as passive system, (3) Fast and accurate detection of enrichment changes, (4) Physics is well understood, (5) Elegant method for capturing pressure signal, and (6) Data capture is automatic, low cost and fast. A couple of negative things are: (1) Some jumps in measured passive enrichment - of around +2% relative (due to clock errors?); and (2) Data handling and evaluation is off-line, expensive and very slow. Conclusions are: (1) LANL AEM is being tested on E23 plant at Capenhurst; (2) The trial is going very well; (3) AEM could detect production of HEU at potentially much lower cost than existing CEMO; (4) AEM can measure {sup 235}U assay accurately; (5) Active system using X-Ray source would avoid need for pressure measurement; (6) Substantial work lies ahead to go from current prototype to a production instrument.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neurohumoral indicators of efficacy radiofrequency cardiac denervation

In this study, we compared pre- and postoperative parameters of the cardiac sympathetic innervation. The aim of the study was to examine the approaches to evaluating the quality of radiofrequency (RF)-induced cardiac denervation by using non-invasive and laboratory methods. The study included 32 people with long-lasting persistent atrial fibrillation (AF). The patients were divided into 2 groups according to the objectives of the study: group 1 (main) - 21 patients with mitral valve diseases, which simultaneously with radiofrequency ablation (RFA) AF carried out on the effects of the paraganglionic nervous plexuses by C. Pappone (2004) and N. Doll (2008) schemes. The second group (control) contained 11 patients with heart diseases in sinus rhythm (the RF denervation not been performed). All patients, who underwent surgical treatment, were received examination of cardiac sympathetic tone by using {sup 123}I-MIBG. All of them made blood analysis from ascending aorta and coronary sinus to determine the level of norepinephrine and its metabolites before and after cardiac denervation. Data of radionuclide examination are correlating with laboratory data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Are We Appropriately Selecting Therapy For Patients With Cervical Cancer? Longitudinal Patterns-of-Care Analysis for Stage IB-IIB Cervical Cancer

Purpose: We performed a patterns-of-care analysis evaluating the effects of newer technology and recent research findings on treatment decisions over 26 years to determine whether patients with cervical cancer are being appropriately selected for treatment to optimize the therapeutic ratio. Methods and Materials: A retrospective analysis was conducted using the Surveillance, Epidemiology and End Results (SEER) program from 1983 to 2009. We identified 10,933 women with stage IB-IIB cervical carcinoma. Results: Of the 10,933 subjects identified, 40.1% received surgery, 26.8% received radiation (RT), and 33.1% received surgery plus RT. RT use increased after 2000 compared to prior to 2000, with a corresponding decrease in surgery and surgery plus RT. Among patients with risk factors including tumor size >4 cm, positive parametria, and positive lymph nodes, declining use of surgery plus RT was observed. However, 23% of patients with tumors >4 cm, 20% of patients with positive parametria, and 55% of node-positive patients continued to receive surgery plus RT as of 2009. Factors associated with increased use of surgery plus RT included patient age <50 and node-positive status. Conclusions: In this largest patterns-of-care analysis to date for patients with locally advanced cervical cancer, we found a substantial proportion of patients continue to undergo surgery followed by radiation, despite randomized data supporting the use of definitive radiation therapy, with lower morbidity than surgery and radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗