Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Low-phase-noise surface-acoustic-wave oscillator using an edge mode of a phononic band gap

Low-phase-noise microwave-frequency integrated oscillators provide compact solutions for various applications in signal processing, communications, and sensing. Surface acoustic waves (SAWs), featuring orders-of-magnitude shorter wavelength than electromagnetic waves at the same frequency, enable integrated microwave-frequency systems with much smaller footprint on chip. SAW devices also allow higher-quality (Q) factors than electronic components at room temperature. Here, we demonstrate a low-phase-noise gigahertz-frequency SAW oscillator on 128°Y-cut lithium niobate, where the SAW resonator occupies a footprint of 0.05 mm 2 . Leveraging phononic crystal band-gap-edge modes to balance between Q factors and insertion losses, our 1-GHz SAW oscillator features a low phase noise of -132.5 dBc/Hz at a 10-kHz offset frequency and an overlapping Hadamard deviation of 6.5 × 10 -10 at an analysis time of 64 ms. The SAW resonator-based oscillator holds high potential in developing low-noise sensors and acousto-optic integrated circuits.

42 ENGINEERING↗

Spatiotemporal optical pulse transformation by a resonant diffraction grating

The diffraction of a spatiotemporal optical pulse by a resonant diffraction grating is considered. The pulse diffraction is described in terms of the signal (the spatiotemporal incident pulse envelope) passage through a linear system. An analytic approximation in the form of a rational function of two variables corresponding to the angular and spatial frequencies has been obtained for the transfer function of the system. A hyperbolic partial differential equation describing the general form of the incident pulse envelope transformation upon diffraction by a resonant diffraction grating has been derived from the transfer function. A solution of this equation has been obtained for the case of normal incidence of a pulse with a central frequency lying near the guided-mode resonance of a diffraction structure. The presented results of numerical simulations of pulse diffraction by a resonant grating show profound changes in the pulse envelope shape that closely correspond to the proposed theoretical description. The results of the paper can be applied in creating new devices for optical pulse shape transformation, in optical information processing problems, and analog optical computations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Airborne Visible/Infrared Imaging Spectrometer 3 (AVIRIS-3)

The Airborne Visible/Infrared Imaging Spectrometer 3 (AVIRIS-3) is the third of the NASA AVIRIS spectrometer series and is being developed in parallel with the Compact Wide-swath Imaging Spectrometer II (CWIS-II) for the University of Zurich, Switzerland. The core spectrometer of AVIRIS-3 is a copy of the optically fast, F/1.8 Dyson imaging spectrometer used by the Earth Surface Mineral Dust Source Investigation (EMIT) that is in development and scheduled for launch to the International Space Station (ISS) in 2022. AVIRIS-3 is intended to provide state-of-the-art imaging spectroscopy measurements for NASA science and application through the next decade and beyond. AVIRIS-3 uses the EMIT spectrometer design interfaced with a scaled two mirror telescope enclosed in a portable vacuum vessel to enable measurements from airborne platforms ranging from a Twin Otter to a business jet or a NASA ER-2. AVIRIS-3 is a cryogenic instrument with advanced system control and real-time onboard spectroscopic data processing algorithms evolved from AVIRIS-NG. The spectral range of AVIRIS-3 is 380 to 2500 nm with 7.4 nm sampling. The radiometric range is from 0 to max terrestrial Lambertian radiance with higher signal-to-noise ratio performance than AVIRIS-Classic or AVIRIS-Next Generation. The spatial field-of-view is 39.5 degrees with 0.56 milliradian sampling. This paper describes the design and development of AVIRIS-3 and presents its characteristics in comparison to the previous generation imaging spectrometers.

Helmlinger, Mark↗

Application of beam emission spectroscopy to NBI plasmas of Heliotron J

This paper describes the application of the beam emission spectroscopy (BES) to Heliotron J, having the nonsymmetrical helical-magnetic-axis configuration. The spectral and spatial profile of the beam emission has been estimated by the numerical calculation taking the collisional excitation processes between plasmas (electrons/ions) and beam atoms. Two sets of the sightlines with good spatial resolution are presented. One is the optimized viewing chords which have 20 sightlines and observe the whole plasma region with the spatial resolution {Delta}{rho} less than {+-}0.055 using the newly designed viewing port. The other is 15 sightlines from the present viewing port of Heliotron J for the preliminary measurement to discuss the feasibility of the density fluctuation measurement by BES. The beam emission has been measured by a monochromator with a CCD camera. A good consistency has been obtained between the spectral profiles of the beam emission measured by the monochromator and the beam emission spectrum deduced by the model calculation. An avalanche photodiode with an interference filter system was also used to evaluate the signal-to-noise (S/N) ratio of the beam emission in the present experimental setup. The modification of the optical system is being planned to improve the S/N ratio, which will enable us to estimate the density fluctuation in Heliotron J.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses that may not be important in longer wavelength designs. This paper describes the design of multi- bandwidth filters operating in the 1-5 micrometer wavelength range. This work follows on a previous design. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using microlithographic techniques and used in spectral imaging applications will be presented.

Cwik, Tom↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses tha_ may not be important in longer wavelength designs. This paper describes the design of multi-bandwidth filters operating in the I-5 micrometer wavelength range. This work follows on previous design [1,2]. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using micro-lithographic techniques and used ir spectral imaging applications will be presented.

Cwik, Tom↗

Highly sensitive and accurate optical thermometer through Er doped tellurite glasses

Highlights: • Upconversion mechanisms of transparent Er{sup 3+} doped tellurite glasses are discussed. • Sensitivity of the thermometer based on the FIR technique increases monotonously with the decreasing doping concentration. • Highly sensitive and accurate optical thermometer is achieved using low doping sample as the probe and high power laser as the pumping source. - Abstract: We investigate the thermal effects of Er{sup 3+} doped tellurite glasses on the upconversion properties. It is found that the sensitivity of the thermometer based on the FIR technique increases monotonously with the decreasing doping concentration. However, low doping leads to weak upconversion intensity and further decrease the sensing accuracy, which makes it difficult to achieve the high sensitivity and accuracy simultaneously. Influences of the irradiating laser power on the sensing behaviors were studied in the purpose of enhancing the signal intensity. It is found that the heating effect of incident laser (up to hundreds of mW) can be neglected, indicating the feasibility of using high laser power and low doping sample to produce both high sensitivity and high accuracy. In addition, this paper respectively discusses the mechanisms of the upconversion processes and the concentration dependent sensitivity.

36 MATERIALS SCIENCE↗

Development of Research Infrastructure in Nevada for the Exploitation of Hyperspectral Image Data to Address Proliferation and Detection of Chemical and Biological Materials.

This research was to exploit hyperspectral reflectance imaging technology for the detection and mapping variability (clutter) of the natural background against which gases in the atmosphere are imaged. The natural background consists of landscape surface cover composed of consolidated rocks, unconsolidated rock weathering products, soils, coatings on rock materials, vegetation, water, materials constructed by humans, and mixtures of the above. Human made gases in the atmosphere may indicate industrial processes important to detecting non-nuclear chemical and biological proliferation. Our research was to exploit the Visible and Near-Infrared (NIR) and the Short-wave Infrared (SWIR) portions of the electromagnetic spectrum to determine the properties of solid materials on the earth’s surface that could influence the detection of gases in the Long-Wave Infrared (LWIR). We used some new experimental hyperspectral imaging technologies to collect data over the Non-Proliferation Test and Evaluation Center (NPTEC) located on the Nevada Test Site (NTS). The SpecTIR HyperSpecTIR (HST) and Specim Dual hyperspectral sensors were used to understand the variability in the imaged background (clutter), that detected, measured, identified and mapped with operational commercial hyperspectral techniques. The HST sensors were determined to be more experimental than operational because of problems with radiometric and atmospheric data correction. However the SpecTIR Dual system, developed by Specim in Finland, eventually was found to provide cost-effective hyperspectral image data collection and it was possible to correct the Dual system’s data for specific areas. Batch processing of long flightlines was still complex, and if comparison to laboratory spectra was desired, the Dual system data still had to be processed using the empirical line method. This research determined that 5-meter spatial resolution was adequate for mapping natural background variations. Furthermore, this research determined that spectral resolution of 10um was adequate, but a signal to noise above 300:1 was desirable for hyperspectral sensors with this spectral resolution. Finally, we acquired a hyperspectral thermal dataset (SEBASS) at 3m spatial resolution over our study area in Beatty, Nevada that can be co-registered with the hyperspectral reflectance, LIDAR and digital Orthophoto data sets. This data set will enable us to quantify how measurements in the reflected infrared can be used to make inferences about the response of materials in the thermal infrared, the topic of our follow-on NA-22 investigation ending in 2008. These data provide the basis for our investigations proposed for the NA-22 2008 Broad Area Announcement. Beginning in June 2008, SpecTIR Corporation and Aerospace Corporation plan to fly the SpecTIR Dual and SEBASS in a stabilized mount in a twin Otter aircraft. This research provides the foundation for using reflected and emitted hyperspectral measurements together for mapping geologic and soil materials in arid to semi-arid regions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental upper bounds for resonance-enhanced entangled two-photon absorption cross section of indocyanine green

Resonant intermediate states have been proposed to increase the efficiency of entangled two-photon absorption (ETPA). Although resonance-enhanced ETPA (r-ETPA) has been demonstrated in atomic systems using bright squeezed vacuum, it has not been studied in organic molecules. We investigate for the first time r-ETPA in an organic molecular dye, indocyanine green (ICG), when excited by broadband entangled photons in near-IR. Similar to many reported virtual state mediated ETPA (v-ETPA) measurements, no r-ETPA signals are measured, with an experimental upper bound for the cross section placed at 6(±2) × 10 −23 cm 2 . In addition, the classical resonance-enhanced two-photon absorption (r-TPA) cross section of ICG at 800 nm is measured for the first time to be 20(±13) GM, where 1 GM equals 10 −50 cm 4 s, suggesting that having a resonant intermediate state does not significantly enhance two-photon processes in ICG. Furthermore, the spectrotemporally resolved emission signatures of ICG excited by entangled photons are also presented to support this conclusion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Role of Margin in Link Design and Optimization

Link analysis is a system engineering process in the design, development, and operation of communication systems and networks. Link models that are mathematical abstractions representing the useful signal power and the undesirable noise and attenuation effects (including weather effects if the signal path transverses through the atmosphere) that are integrated into the link budget calculation that provides the estimates of signal power and noise power at the receiver. Then the link margin is applied which attempts to counteract the fluctuations of the signal and noise power to ensure reliable data delivery from transmitter to receiver. (Link margin is dictated by the link margin policy or requirements.) A simple link budgeting approach assumes link parameters to be deterministic values typically adopted a rule-of-thumb policy of 3 dB link margin. This policy works for most S- and X-band links due to their insensitivity to weather effects. But for higher frequency links like Ka-band, Ku-band, and optical communication links, it is unclear if a 3 dB link margin would guarantee link closure. Statistical link analysis that adopted the 2-sigma or 3-sigma link margin incorporates link uncertainties in the sigma calculation. (The Deep Space Network (DSN) link margin policies are 2-sigma for downlink and 3-sigma for uplink.) The link reliability can therefore be quantified statistically even for higher frequency links. However in the current statistical link analysis approach, link reliability is only expressed as the likelihood of exceeding the signal-to-noise ratio (SNR) threshold that corresponds to a given bit-error-rate (BER) or frame-error-rate (FER) requirement. The method does not provide the true BER or FER estimate of the link with margin, or the required signalto-noise ratio (SNR) that would meet the BER or FER requirement in the statistical sense. In this paper, we perform in-depth analysis on the relationship between BER/FER requirement, operating SNR, and coding performance curve, in the case when the channel coherence time of link fluctuation is comparable or larger than the time duration of a codeword. We compute the "true" SNR design point that would meet the BER/FER requirement by taking into account the fluctuation of signal power and noise power at the receiver, and the shape of the coding performance curve. This analysis yields a number of valuable insights on the design choices of coding scheme and link margin for the reliable data delivery of a communication system - space and ground. We illustrate the aforementioned analysis using a number of standard NASA error-correcting codes.

Cheung, K.↗

Design of the Trigger Interface and Distribution Board for TJNAF 12 GeV Upgrade

The design of the Trigger Interface and Distribution (TID) board for the 12 GeV Upgrade at Thomas Jefferson National Accelerator Facility (TJNAF) is described. The TID board distributes a low jitter system clock, synchronized trigger, and synchronized multi-purpose SYNC signal. The TID also initiates readout for the data acquisition front-end crate. With the TID boards, a multi-crate system can be setup for large scale nuclear physics experiments. The TID board can be selectively populated as a Trigger Interface (TI) board, or a Trigger Distribution (TD) board for the 12 GeV upgrade experiments. When the TID is populated as a TI, The TID can be located in the VXS crate and distribute the CLOCK/TRIGGER/SYNC (CTS) through the VXS/P0 connector; it can also be located in the standard VME64 crate, and distribute the CTS through the VME/P2 connector or front panel connectors. It initiates the data acquisition for the front-end crate where the TI is positioned in. When the TID is populated as a TD, it fans out the CTS from the trigger supervisor to the front-end crates through optical fibres. The TD board monitors the trigger processing on the TI boards, and sends feedback to the Trigger Supervisor (TS) board for event readout flow control. A Field Programmable Gate Arrays (FPGA) is utilised on the TID board to provide programmability. The TID board was intensively tested on the bench. The TID production version has been released to industry for contract manufacturing.

Gu, Jianhui W.↗

Optical tailoring of xFEL beams

There is an inherent flexibility unique to free electron lasers (FELs) that lends well to experimental approaches normally too difficult for other light sources to accomplish. This includes the ability to optically shape the electron bunch prior to final its acceleration for the final FEL process. Optical pulse shaping of the electron bunch can enable both femtosecond and attosecond level FEL pulse control. Pulse shaping is currently implemented, not optically but mechanically, in LCLS-I with an adjustable foil slit that physically spoils the momentum phase of the electron bunch. This selectively suppresses the downstream FEL process of spoiled electrons. Such a mechanical spoiling method fails for both the soft x-ray regime as well as the high repetition rates that are planned in LCLS-II. Our proposed optical spoiling method circumvents this limitation by making use of the existing ultrafast laser beam that is typically used for adjusting the energy spread for the initial electron bunch. Using Fourier domain shaping we can nearly arbitrarily shape the laser pulses to affect the electron bunch. This can selectively spoil electrons within each bunch. Here we demonstrate the viability of this approach with a programmable acousto-optic dispersive filter. This method is not only well suited for LCLS-II but also has several advantages over mechanical spoiling, including lack of radiation concerns, experiment specific FEL pulse shapes, and real-time adjustment for applications that require high duty-cycle variation such as lock-in amplification of small signals.

43 PARTICLE ACCELERATORS↗

Clear as mud redefined: Tunable transparent mineral scaffolds for visualizing microbial processes below ground

Microbes inhabiting complex porous microenvironments in sediments and aquifers catalyze reactions that are critical to global biogeochemical cycles and ecosystem health. However, the opacity and complexity of porous sediment and rock matrices have considerably hindered the study of microbial processes occurring within these habitats. Here, we generated microbially compatible, optically transparent mineral scaffolds to visualize and investigate microbial colonization and activities occurring in these environments, in laboratory settings and in situ. Using inexpensive synthetic cryolite mineral, we produced optically transparent scaffolds mimicking the complex 3D structure of sediments and rocks by adapting a suspension-based, freeze-casting technique commonly used in materials science. Fine-tuning of parameters, such as freezing rate and choice of solvent, provided full control of pore size and architecture. The combined effects of scaffold porosity and structure on the movement of microbe-sized particles, tested using velocity tracking of fluorescent beads, showed diverse yet reproducible behaviors. The scaffolds we produced are compatible with epifluorescence microscopy, allowing the fluorescence-based identification of colonizing microbes by DNA-based staining and fluorescence in situ hybridization (FISH) to depths of 100 µm. Additionally, Raman spectroscopy analysis indicates minimal background signal in regions used for measuring deuterium and 13 C enrichment in microorganisms, highlighting the potential to directly couple D 2 O or 13 C stable isotope probing and Raman-FISH for quantifying microbial activity at the single-cell level. To demonstrate the relevance of cryolite scaffolds for environmental field studies, we visualized their colonization by diverse microorganisms within rhizosphere sediments of a coastal seagrass plant using epifluorescence microscopy. The tool presented here enables highly resolved, spatially explicit, and multimodal investigations into the distribution, activities, and interactions of underground microbes typically obscured within opaque geological materials until now.

36 MATERIALS SCIENCE↗

Hamiltonian structure of propagation equations for ultrashort optical pulses

A Hamiltonian framework is developed for a sequence of ultrashort optical pulses propagating in a nonlinear dispersive medium. To this end a second-order nonlinear wave equation for the electric field is transformed into a first-order propagation equation for a suitably defined complex electric field. The Hamiltonian formulation is then introduced in terms of normal variables, i.e., classical complex fields referring to the quantum creation and annihilation operators. The derived z-propagated Hamiltonian accounts for forward and backward waves, arbitrary medium dispersion, and four-wave mixing processes. As a simple application we obtain integrals of motion for the pulse propagation. The integrals reflect time-averaged fluxes of energy, momentum, and photons transferred by the pulse. Furthermore, pulses in the form of stationary nonlinear waves are considered. They yield extremal values of the momentum flux for a given energy flux. Simplified propagation equations are obtained by reduction of the Hamiltonian. In particular, the complex electric field reduces to an analytic signal for the unidirectional propagation. Solutions of the full bidirectional model are numerically compared to the predictions of the simplified equation for the analytic signal and to the so-called forward Maxwell equation. The numerics is effectively tested by examining the conservation laws.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterizing the epoch of reionization with the small-scale CMB: Constraints on the optical depth and duration

Patchy reionization leaves a number of imprints on the small-scale cosmic microwave background (CMB) temperature fluctuations, the largest of which is the kinematic Sunyaev-Zel'dovich (kSZ), the Doppler shift of CMB photons scattering off moving electrons in ionized bubbles. It has long been known that in the CMB power spectrum, this imprint of reionization is largely degenerate with the kSZ signal produced by late-time galaxies and clusters, thus limiting our ability to constrain reionization. Following Smith & Ferraro (2017), it is possible to isolate the reionization contribution in a model independent way, by looking at the large scale modulation of the small scale CMB power spectrum. In this paper we extend the formalism to use the full shape information of the small scale power spectrum (rather than just its broadband average), and argue that this is necessary to break the degeneracy between the optical depth τ and parameters setting the duration of reionization. In particular, we show that the next generation of CMB experiments could achieve up to a factor of 3 improvement on the optical depth τ and at the same time, constrain the duration of reionization to ~25%. Finally, this can help tighten the constrains on neutrino masses, which will be limited by our knowledge of τ, and shed light on the physical processes responsible for reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of modified uni-traveling carrier photodiode for cryogenic microwave photonic links

Quantum devices present the potential for unparalleled computing and communications capabilities; however, the cryogenic temperatures required to successfully control and read out many qubit platforms can prove to be very challenging to scale. Recently, there has emerged an interest in using microwave photonics to deliver control signals down to ultracold stages via optical fiber, thereby reducing thermal load and facilitating dense wavelength multiplexing. Photodetectors can then convert this optical energy to electrical signals for qubit control. The fidelity of the quantum operations of interest therefore depend heavily upon the characteristics of the photodiode, yet experimental demonstrations of fiber-coupled photodetection systems at low temperatures are relatively few in number, leaving important open questions regarding how specific detectors may perform in real-world cryogenic settings. In this work, we examine a highly linear modified uni-traveling carrier photodiode (MUTC-PD) under C-band illumination (1530–1565 nm) at three temperature regimes (300 K, 80 K, and ∼4 K) and multiple bias conditions. Our findings of reduced responsivity but preserved bandwidth are consistent with previous studies, while our saturation tests suggest a variety of potential applications for MUTC-PDs in cryogenic microwave photonics with and without electrical bias. Overall, our results should provide a valuable foundation for the continued and expanding use of this detector technology in quantum information processing.

47 OTHER INSTRUMENTATION↗

Luminescent Materials for the Detection of Economically Critical Metals in Harsh Environments

Renewable energy technologies used for electric vehicles and wind turbines are heavily reliant upon metals, such as rare earth elements, cobalt, lithium, and nickel. Indeed, there are 50 minerals that are currently considered “economically critical” by the 2022 United States Geological Survey. With anticipated global adoption of renewable energy technologies, producing sufficient metals to meet this demand presents a significant challenge, particularly due to the current monopolistic market for many of these metals. The production of metals from unconventional sources, such as coal utilization byproducts, is one of many promising strategies to boost domestic supply. However, sensitive, rapid, and inexpensive characterization technologies are needed to minimize production costs associated with metals prospecting and processing. Photoluminescence-based sensing techniques are particularly intriguing due to their potential for low cost and portability, coupled with high sensitivity and selectivity. This presentation focuses on the development of high-performance sensing materials for a range of critical metals, including metal-organic frameworks capable of sensitizing detection of parts-per-billion concentrations of six different rare earth elements, nanoparticles that can detect down to 600 parts-per-billion levels of cobalt, and thin films that sense aluminum down to 120 parts-per-billion. These materials are highly selective, capable of withstanding low pH conditions, and provide a response within minutes. Importantly, each sensing material is integrated with a custom-built, fully portable fiber-optic spectrometer for potential field deployment, providing significant cost savings over commercial instruments, along with potential advantages such as material regeneration for use across multiple sensing cycles and solvent removal for enhanced emission signal. These results highlight the exciting potential of luminescence platforms as cost-effective alternatives for metals characterization.

Crawford, Scott↗

Semiselective Optoelectronic Sensors for Monitoring Microbes

Sensor systems are under development for use in real-time detection and quantitation of microbes in water without need for sampling. These systems include arrays of optical sensors; miniature, portable electronic data-acquisition circuits; and optoelectronic interfaces between the sensor arrays and data-acquisition circuits. These systems are intended for original use in long-term, inline monitoring of waterborne micro-organisms in water-reclamation systems aboard future spacecraft. They could also be adapted to similar terrestrial uses with respect to municipal water supplies, stored drinking water, and swimming water; for detecting low-level biological contamination in biotechnological, semiconductor, and pharmaceutical process streams; and in verifying the safety of foods and beverages. In addition, they could be adapted to monitoring of airborne microbes and of surfaces (e.g., to detect and/or quantitate biofilms). The designs of the sensors in these systems are based partly on those of sensors developed previously for monitoring airborne biological materials. The designs exploit molecular- recognition and fluorescence-spectroscopy techniques, such that in the presence of micro-organisms of interest, fluorescence signals change and the changes can be measured. These systems are characterized as semiselective because they respond to classes of micro-organisms and can be used to discriminate among the classes. This semiselectivity is a major aspect of the design: It is important to distinguish between (1) the principle of detection and quantitation of classes of micro-organisms by use of these sensors and (2) the principle of detection and quantitation of individual microbiological species by means of prior immuno-diagnostic and/or molecular-biology techniques. Detection of classes (in contradistinction to species) is particularly valuable when the exact nature of a contaminant is unknown.

Tabacco, Mary Beth↗