Large scale maximum average power multiple inference on time-course count data with application to RNA-seq analysis
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Abstract A surrogate model is a common tool to approximate system response at untested points for design space exploration. Adaptive sampling has been studied for improving the accuracy of surrogates iteratively by introducing additional samples (simulations and experiments). New samples are often selected based on the estimated uncertainty in the design space. While some surrogates such as kriging have readily available uncertainty models for their predictions, other surrogates do not. Consequently, there have been studies of using the process of leaving-samples-out (LSO) used in cross-validation tools to estimate prediction uncertainty, such as the universal prediction distribution (UPD). In this paper, an adaptive sampling scheme for general surrogates is proposed based on LSO, similar to cross-validation and interquartile range (IQR). Multiple submodels are first developed from LSO. The uncertainty is then estimated from the IQR of these surrogates at a given point. New samples are added iteratively at the point with maximum IQR for design space exploration. The proposed scheme is illustrated using kriging, radial basis function, and neural network surrogates. The proposed scheme is evaluated using four algebraic test functions. Multiple sets of initial samples were produced to account for randomness. For these test functions, the proposed scheme was found to be more accurate and robust than kriging with its own uncertainty model. The proposed scheme was more accurate than the UPD for three out of the four test functions. For a fixed number of samples, the IQR-based adaptive sampling also proved to be more accurate than all-at-once sampling in most cases even when the estimated uncertainty was only mildly correlated with prediction errors.
Increasing deployment of advanced sensing, controls, and communication infrastructure enables buildings to provide services to the power grid, leading to the concept of grid-interactive efficient buildings. Since occupant activities and preferences primarily drive the availability and operational flexibility of building devices, there is a critical need to develop occupant-centric approaches that prioritize devices for providing grid services, while maintaining the desired end-use quality of service. In this paper, we present a decision-making framework that facilitates a building owner/operator to effectively prioritize loads for curtailment service under uncertainties, while minimizing any adverse impact on the occupants. The proposed framework uses a stochastic (Markov) model to represent the probabilistic behavior of device usage from power consumption data, and a load prioritization algorithm that dynamically ranks building loads using a stochastic multi-criteria decision-making algorithm. The proposed load prioritization framework is illustrated via numerical simulations in a residential building use-case, including plug-loads, air-conditioners, and plug-in electric vehicle chargers, in the context of load curtailment as a grid service. Suitable metrics are proposed to evaluate the closed-loop performance of the proposed prioritization algorithm under various scenarios and design choices. Scalability of the proposed algorithm is established via computational analysis, while time-series plots are used for intuitive explanation of the ranking choices.
Each year, more than 20% of electricity generated in the United States is consumed for meeting the thermal demands (e.g., space cooling, space heating, and water heating) in residential and commercial buildings. Integrating thermal energy storage (TES) with building’s HVAC systems has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable generation and the demand of buildings. A novel ground source heat pump (GSHP) system integrated with underground thermal energy storage (UTES) has been proposed to level the electric demand of buildings while still satisfying their thermal demands. This study assessed the potential impacts of the proposed system with a bottom-up approach. The impacts on the electricity demand in various electricity markets were quantified. The results show that, within the capacity of the existing electric grids, the maximum penetration rate of the proposed system in different wholesale markets could range from 51% to 100%. Altogether, about 46 million single-family detached houses can be retrofitted into the proposed system without increasing the annual peak demand of the corresponding markets. By implementing the proposed system at its maximum penetration rate, the grid-level summer peak demand can be reduced by 9.1% to 18.2%. Meanwhile, at the grid level, the annual electricity consumption would change by –12% to 2%. The nationwide total electricity consumption would be reduced by 9%.
The current rules for elevated temperature ASME Section III, Division 5, Class B components, other than piping, were basically adapted from the Design-by-Rule approach for Section VIII, Division 1 vessels. A goal of the proposed new rules is to explicitly account for the design life and cyclic service while recognizing the less-rigorous requirements commensurate with lesser safety consideration. Further goals are to maximize the use of modern computational technology, for example finite element analysis in conjunction with reference stress concepts, and to avoid the need for stress classification. This paper summarizes the work done to address these issues. A summary of the design-by-analysis for primary loads, strain limit evaluation, and creep-fatigue damage assessment is presented. The proposed design-by-analysis creep-fatigue damage calculation approach uses a new elastic follow-up-based Isochronous Stress Strain Curve stress relaxation procedure. A set of sample problems are selected to validate the proposed design-by-analysis rules for creep-fatigue damage assessment. The proposed Class B rules are evaluated against the Class A elastic design rules and the experimental data obtained from a family of a simplified model test-based key-feature test results. The proposed Class B creep-fatigue damage assessment methodology yields conservative design cycles estimates compared to the experimental results.
Purpose: In computed tomographic colonography (CTC), a patient will be scanned twice--Once supine and once prone--to improve the sensitivity for polyp detection. To assist radiologists in CTC reading, in this paper we propose an automated method for colon registration from supine and prone CTC scans. Methods: We propose a new colon centerline registration method for prone and supine CTC scans using correlation optimized warping (COW) and canonical correlation analysis (CCA) based on the anatomical structure of the colon. Four anatomical salient points on the colon are first automatically distinguished. Then correlation optimized warping is applied to the segments defined by the anatomical landmarks to improve the global registration based on local correlation of segments. The COW method was modified by embedding canonical correlation analysis to allow multiple features along the colon centerline to be used in our implementation. Results: We tested the COW algorithm on a CTC data set of 39 patients with 39 polyps (19 training and 20 test cases) to verify the effectiveness of the proposed COW registration method. Experimental results on the test set show that the COW method significantly reduces the average estimation error in a polyp location between supine and prone scans by 67.6%, from 46.27{+-}52.97 to 14.98 mm{+-}11.41 mm, compared to the normalized distance along the colon centerline algorithm (p<0.01). Conclusions: The proposed COW algorithm is more accurate for the colon centerline registration compared to the normalized distance along the colon centerline method and the dynamic time warping method. Comparison results showed that the feature combination of z-coordinate and curvature achieved lowest registration error compared to the other feature combinations used by COW. The proposed method is tolerant to centerline errors because anatomical landmarks help prevent the propagation of errors across the entire colon centerline.
Purpose: In the segmentation of sequential treatment-time CT prostate images acquired in image-guided radiotherapy, accurately capturing the intrapatient variation of the patient under therapy is more important than capturing interpatient variation. However, using the traditional deformable-model-based segmentation methods, it is difficult to capture intrapatient variation when the number of samples from the same patient is limited. This article presents a new deformable model, designed specifically for segmenting sequential CT images of the prostate, which leverages both population and patient-specific statistics to accurately capture the intrapatient variation of the patient under therapy. Methods: The novelty of the proposed method is twofold: First, a weighted combination of gradient and probability distribution function (PDF) features is used to build the appearance model to guide model deformation. The strengths of each feature type are emphasized by dynamically adjusting the weight between the profile-based gradient features and the local-region-based PDF features during the optimization process. An additional novel aspect of the gradient-based features is that, to alleviate the effect of feature inconsistency in the regions of gas and bone adjacent to the prostate, the optimal profile length at each landmark is calculated by statistically investigating the intensity profile in the training set. The resulting gradient-PDF combined feature produces more accurate and robust segmentations than general gradient features. Second, an online learning mechanism is used to build shape and appearance statistics for accurately capturing intrapatient variation. Results: The performance of the proposed method was evaluated on 306 images of the 24 patients. Compared to traditional gradient features, the proposed gradient-PDF combination features brought 5.2% increment in the success ratio of segmentation (from 94.1% to 99.3%). To evaluate the effectiveness of online learning mechanism, the authors carried out a comparison between partial online update strategy and full online update strategy. Using the full online update strategy, the mean DSC was improved from 86.6% to 89.3% with 2.8% gain. On the basis of full online update strategy, the manual modification before online update strategy was introduced and tested, the best performance was obtained; here, the mean DSC and the mean ASD achieved 92.4% and 1.47 mm, respectively. Conclusions: The proposed prostate segmentation method provided accurate and robust segmentation results for CT images even under the situation where the samples of patient under radiotherapy were limited. A conclusion that the proposed method is suitable for clinical application can be drawn.
Purpose: In image-guided surgery (IGS) systems, image-to-physical registration is critical for reliable anatomical information mapping and spatial guidance. Conventional stereotactic frame-based or fiducial-based approaches provide accurate registration but are not patient-friendly. This study proposes a frameless cranial IGS system that uses computer vision techniques to replace the frame or fiducials with the natural features of the patient. Methods: To perform a cranial surgery with the proposed system, the facial surface of the patient is first reconstructed by stereo vision. Accuracy is ensured by capturing parallel-line patterns projected from a calibrated LCD projector. Meanwhile, another facial surface is reconstructed from preoperative computed tomography (CT) images of the patient. The proposed iterative closest point (ICP)-based algorithm [fast marker-added ICP (Fast-MICP)] is then used to register the two facial data sets, which transfers the anatomical information from the CT images to the physical space. Results: Experimental results reveal that the Fast-MICP algorithm reduces the computational cost of marker-added ICP (J.-D. Lee et al., ''A coarse-to-fine surface registration algorithm for frameless brain surgery,'' in Proceedings of International Conference of the IEEE Engineering in Medicine and Biology Society, 2007, pp. 836-839) to 10% and achieves comparable registration accuracy, which is under 3 mm target registration error (TRE). Moreover, two types of optical-based spatial digitizing devices can be integrated for further surgical navigation. Anatomical information or image-guided surgical landmarks can be projected onto the patient to obtain an immersive augmented reality environment. Conclusion: The proposed frameless IGS system with stereo vision obtains TRE of less than 3 mm. The proposed Fast-MICP registration algorithm reduces registration time by 90% without compromising accuracy.
Purpose: Applications of cone-beam CT (CBCT) to image-guided radiation therapy (IGRT) are hampered by shading artifacts in the reconstructed images. These artifacts are mainly due to scatter contamination in the projections but also can result from uncorrected beam hardening effects as well as nonlinearities in responses of the amorphous silicon flat panel detectors. While currently, CBCT is mainly used to provide patient geometry information for treatment setup, more demanding applications requiring high-quality CBCT images are under investigation. To tackle these challenges, many CBCT correction algorithms have been proposed; yet, a standard approach still remains unclear. In this work, we propose a shading correction method for CBCT that addresses artifacts from low-frequency projection errors. The method is consistent with the current workflow of radiation therapy. Methods: With much smaller inherent scatter signals and more accurate detectors, diagnostic multidetector CT (MDCT) provides high quality CT images that are routinely used for radiation treatment planning. Using the MDCT image as ''free'' prior information, we first estimate the primary projections in the CBCT scan via forward projection of the spatially registered MDCT data. Since most of the CBCT shading artifacts stem from low-frequency errors in the projections such as scatter, these errors can be accurately estimated by low-pass filtering the difference between the estimated and raw CBCT projections. The error estimates are then subtracted from the raw CBCT projections. Our method is distinct from other published correction methods that use the MDCT image as a prior because it is projection-based and uses limited patient anatomical information from the MDCT image. The merit of CBCT-based treatment monitoring is therefore retained. Results: The proposed method is evaluated using two phantom studies on tabletop systems. On the Catphan(c)600 phantom, our approach reduces the reconstruction error from 348 Hounsfield unit (HU) without correction to 4 HU around the object center after correction, and from 375 HU to 17 HU in the high-contrast regions. In the selected regions of interest (ROIs), the average image contrast is increased by a factor of 3.3. When noise suppression is implemented, the proposed correction substantially improves the contrast-to-noise ratio (CNR) and therefore the visibility of low-contrast objects, as seen in a more challenging pelvis phantom study. Besides a significant improvement in image uniformity, a low-contrast object of {approx}25 HU, which is otherwise buried in the shading artifacts, can be clearly identified after the proposed correction due to a CNR increase of 3.1. Compared to a kernel-based scatter correction method coupled with an analytical beam hardening correction, our approach also shows an overall improved performance with some residual artifacts. Conclusions: By providing effective shading correction, our approach has the potential to improve the accuracy of more advanced CBCT-based clinical applications for IGRT, such as tumor delineation and dose calculation.
Purpose: Biological soft tissues encountered in clinical and preclinical imaging mainly consists of atoms of light elements with low atomic numbers and their elemental composition is nearly uniform with little density variation. Hence, x-ray attenuation contrast is relatively poor and cannot achieve satisfactory sensitivity and specificity. In contrast, x-ray phase-contrast provides a new mechanism for soft tissue imaging. The x-ray phase shift of soft tissues is about a thousand times greater than the x-ray absorption over the diagnostic x-ray energy range, yielding a higher signal-to-noise ratio than the attenuation contrast counterpart. Thus, phase-contrast imaging is a promising technique to reveal detailed structural variation in soft tissues, offering a high contrast resolution between healthy and malignant tissues. Here the authors develop a novel phase retrieval method to reconstruct the phase image on the object plane from the intensity measurements. The reconstructed phase image is a projection of the phase shift induced by an object and serves as input to reconstruct the 3D refractive index distribution inside the object using a tomographic reconstruction algorithm. Such x-ray refractive index images can reveal structural features in soft tissues, with excellent resolution differentiating healthy and malignant tissues. Methods: A novel phase retrieval approach is proposed to reconstruct an x-ray phase image of an object based on the paraxial Fresnel-Kirchhoff diffraction theory. A primary advantage of the authors' approach is higher-order accuracy over that with the conventional linear approximation models, relaxing the current restriction of slow phase variation. The nonlinear terms in the autocorrelation equation of the Fresnel diffraction pattern are eliminated using intensity images measured at different distances in the Fresnel diffraction region, simplifying the phase reconstruction to a linear inverse problem. Numerical experiments are performed to demonstrate the accuracy and stability of the proposed approach. Results: The proposed reconstruction formula is a generalization of the transport of intensity equation (TIE). It has the second-order accuracy compared to the linear model used in the conventional phase retrieval approach. The numerical experiments demonstrate that the accuracy and stability of the proposed phase reconstruction method outperforms the TIE-based reconstruction method. Conclusions: A novel approach has been proposed to retrieve an x-ray phase shift image induced by an object from intensity images measured at different distances in the Fresnel diffraction region. The authors' approach has the second-order accuracy and is able to retrieve the phase shift of an object stably, overcoming the restriction of slow phase variation assumed by the conventional phase retrieval techniques.
Purpose: To develop a method to reconstruct an interior region-of-interest (ROI) image with sufficient accuracy that uses differentiated backprojection (DBP) projection onto convex sets (POCS) [H. Kudo et al., ''Tiny a priori knowledge solves the interior problem in computed tomography'', Phys. Med. Biol. 53, 2207-2231 (2008)] and a tiny knowledge that there exists a nearly piecewise constant subregion. Methods: The proposed method first employs filtered backprojection to reconstruct an image on which a tiny region P with a small variation in the pixel values is identified inside the ROI. Total variation minimization [H. Yu and G. Wang, ''Compressed sensing based interior tomography'', Phys. Med. Biol. 54, 2791-2805 (2009); W. Han et al., ''A general total variation minimization theorem for compressed sensing based interior tomography'', Int. J. Biomed. Imaging 2009, Article 125871 (2009)] is then employed to obtain pixel values in the subregion P, which serve as a priori knowledge in the next step. Finally, DBP-POCS is performed to reconstruct f(x,y) inside the ROI. Clinical data and the reconstructed image obtained by an x-ray computed tomography system (SOMATOM Definition; Siemens Healthcare) were used to validate the proposed method. The detector covers an object with a diameter of {approx}500 mm. The projection data were truncated either moderately to limit the detector coverage to diameter 350 mm of the object or severely to cover diameter 199 mm. Images were reconstructed using the proposed method. Results: The proposed method provided ROI images with correct pixel values in all areas except near the edge of the ROI. The coefficient of variation, i.e., the root mean square error divided by the mean pixel values, was less than 2.0% or 4.5% with the moderate or severe truncation cases, respectively, except near the boundary of the ROI. Conclusions: The proposed method allows for reconstructing interior ROI images with sufficient accuracy with a tiny knowledge that there exists a nearly piecewise constant subregion.
Purpose: This paper describes a novel method for simultaneous intrafraction tracking of multiple fiducial markers. Although the proposed method is generic and can be adopted for a number of applications including fluoroscopy based patient position monitoring and gated radiotherapy, the tracking results presented in this paper are specific to tracking fiducial markers in a sequence of cone beam CT projection images. Methods: The proposed method is accurate and robust thanks to utilizing the mean shift and random sampling principles, respectively. The performance of the proposed method was evaluated with qualitative and quantitative methods, using data from two pancreatic and one prostate cancer patients and a moving phantom. The ground truth, for quantitative evaluation, was calculated based on manual tracking preformed by three observers. Results: The average dispersion of marker position error calculated from the tracking results for pancreas data (six markers tracked over 640 frames, 3840 marker identifications) was 0.25 mm (at iscoenter), compared with an average dispersion for the manual ground truth estimated at 0.22 mm. For prostate data (three markers tracked over 366 frames, 1098 marker identifications), the average error was 0.34 mm. The estimated tracking error in the pancreas data was < 1 mm (2 pixels) in 97.6% of cases where nearby image clutter was detected and in 100.0% of cases with no nearby image clutter. Conclusions: The proposed method has accuracy comparable to that of manual tracking and, in combination with the proposed batch postprocessing, superior robustness. Marker tracking in cone beam CT (CBCT) projections is useful for a variety of purposes, such as providing data for assessment of intrafraction motion, target tracking during rotational treatment delivery, motion correction of CBCT, and phase sorting for 4D CBCT.
Purpose: To develop a physics-based approach to improve the accuracy and robustness of the ill-conditioned problem of unfolding megavoltage bremsstrahlung spectra from transmission data. Methods: Spectra are specified using a rigorously-benchmarked functional form. Since ion chambers are the typical detector used in transmission measurements, the energy response of a Farmer chamber is calculated using the EGSnrc Monte Carlo code, and the effect of approximating the energy response on the accuracy of the unfolded spectra is studied. A proposal is introduced to enhance spectral sensitivity by combining transmission data measured with multiple detectors of different energy response and by combining data from multiple attenuating materials. Monte Carlo methods are developed to correct for nonideal exponential attenuation (e.g., scatter effects and secondary attenuation). The performance of the proposed methods is evaluated for a diverse set of validated clinical spectra (3.5-25 MV) using analytical transmission data with simulated experimental noise. Results: The approximations commonly used in previous studies for the ion-chamber energy response lead to significant errors in the unfolded spectra. Of the configurations studied, the one with best spectral sensitivity is to measure four full transmission curves using separate low-Z and high-Z attenuators in conjunction with two detectors of different energy response (the authors propose a Farmer-type ion chamber, once with a low-Z, and once with a high-Z buildup cap material), then to feed the data simultaneously to the unfolding algorithm. Deviations from ideal exponential attenuation are as much as 1.5% for the smallest transmission signals, and the proposed methods properly correct for those deviations. The transmission data with enhanced spectral sensitivity, combined with the accurate and flexible spectral functional form, lead to robust unfolding without requiring a priori knowledge of the spectrum. Compared with the commonly-used methods, the accuracy is improved for the unfolded spectra and for the unfolded mean incident electron kinetic energy by at least factors of three and four, respectively. With simulated experimental noise and a lowest transmission of 1%, the unfolded energy fluence spectra agree with the original spectra with a normalized root-mean-square deviation, %{Delta}({psi}), of 2.3%. The unfolded mean incident electron kinetic energies agree, on average, with the original values within 1.4%. A lowest transmission of only 10% still allows unfolding with %{Delta}({psi}) of 3.3%. Conclusions: In the presence of realistic experimental noise, the proposed approach significantly improves the accuracy and robustness of the spectral unfolding problem for all therapy and MV imaging beams of clinical interest.
Purpose: X-ray scatter incurred to detectors degrades the quality of cone-beam computed tomography (CBCT) and represents a problem in volumetric image guided and adaptive radiation therapy. Several methods using a beam blocker for the estimation and subtraction of scatter have been proposed. However, due to missing information resulting from the obstruction of the blocker, such methods require dual scanning or dynamically moving blocker to obtain a complete volumetric image. Here, we propose a half beam blocker-based approach, in conjunction with a total variation (TV) regularized Feldkamp-Davis-Kress (FDK) algorithm, to correct scatter-induced artifacts by simultaneously acquiring image and scatter information from a single-rotation CBCT scan. Methods: A half beam blocker, comprising lead strips, is used to simultaneously acquire image data on one side of the projection data and scatter data on the other half side. One-dimensional cubic B-Spline interpolation/extrapolation is applied to derive patient specific scatter information by using the scatter distributions on strips. The estimated scatter is subtracted from the projection image acquired at the opposite view. With scatter-corrected projections where this subtraction is completed, the FDK algorithm based on a cosine weighting function is performed to reconstruct CBCT volume. To suppress the noise in the reconstructed CBCT images produced by geometric errors between two opposed projections and interpolated scatter information, total variation regularization is applied by a minimization using a steepest gradient descent optimization method. The experimental studies using Catphan504 and anthropomorphic phantoms were carried out to evaluate the performance of the proposed scheme. Results: The scatter-induced shading artifacts were markedly suppressed in CBCT using the proposed scheme. Compared with CBCT without a blocker, the nonuniformity value was reduced from 39.3% to 3.1%. The root mean square error relative to values inside the regions of interest selected from a benchmark scatter free image was reduced from 50 to 11.3. The TV regularization also led to a better contrast-to-noise ratio. Conclusions: An asymmetric half beam blocker-based FDK acquisition and reconstruction technique has been established. The proposed scheme enables simultaneous detection of patient specific scatter and complete volumetric CBCT reconstruction without additional requirements such as prior images, dual scans, or moving strips.
Purpose: To investigate the feasibility of using an image-based method to correct for distortions induced by various artifacts in the x-ray spectrum recorded with photon-counting detectors for their application in breast computed tomography (CT). Methods: The polyenergetic incident spectrum was simulated with the tungsten anode spectral model using the interpolating polynomials (TASMIP) code and carefully calibrated to match the x-ray tube in this study. Experiments were performed on a Cadmium-Zinc-Telluride (CZT) photon-counting detector with five energy thresholds. Energy bins were adjusted to evenly distribute the recorded counts above the noise floor. BR12 phantoms of various thicknesses were used for calibration. A nonlinear function was selected to fit the count correlation between the simulated and the measured spectra in the calibration process. To evaluate the proposed spectral distortion correction method, an empirical fitting derived from the calibration process was applied on the raw images recorded for polymethyl methacrylate (PMMA) phantoms of 8.7, 48.8, and 100.0 mm. Both the corrected counts and the effective attenuation coefficient were compared to the simulated values for each of the five energy bins. The feasibility of applying the proposed method to quantitative material decomposition was tested using a dual-energy imaging technique with a three-material phantom that consisted of water, lipid, and protein. The performance of the spectral distortion correction method was quantified using the relative root-mean-square (RMS) error with respect to the expected values from simulations or areal analysis of the decomposition phantom. Results: The implementation of the proposed method reduced the relative RMS error of the output counts in the five energy bins with respect to the simulated incident counts from 23.0%, 33.0%, and 54.0% to 1.2%, 1.8%, and 7.7% for 8.7, 48.8, and 100.0 mm PMMA phantoms, respectively. The accuracy of the effective attenuation coefficient of PMMA estimate was also improved with the proposed spectral distortion correction. Finally, the relative RMS error of water, lipid, and protein decompositions in dual-energy imaging was significantly reduced from 53.4% to 6.8% after correction was applied. Conclusions: The study demonstrated that dramatic distortions in the recorded raw image yielded from a photon-counting detector could be expected, which presents great challenges for applying the quantitative material decomposition method in spectral CT. The proposed semi-empirical correction method can effectively reduce these errors caused by various artifacts, including pulse pileup and charge sharing effects. Furthermore, rather than detector-specific simulation packages, the method requires a relatively simple calibration process and knowledge about the incident spectrum. Therefore, it may be used as a generalized procedure for the spectral distortion correction of different photon-counting detectors in clinical breast CT systems.
Purpose: Using hybrid x-ray/MR (XMR) systems for image guidance during interventional procedures could enhance the diagnosis and treatment of neurologic, oncologic, cardiovascular, and other disorders. The authors propose a close proximity hybrid system design in which a C-arm fluoroscopy unit is placed immediately adjacent to the solenoid magnet of a MR system with a minimum distance of 1.2 m between the x-ray and MR imaging fields of view. Existing rotating anode x-ray tube designs fail within MR fringe field environments because the magnetic fields alter the electron trajectories in the x-ray tube and act as a brake on the induction motor, reducing the rotation speed of the anode. In this study the authors propose a novel motor design that avoids the anode rotation speed reduction. Methods: The proposed design replaces the permanent magnet stator found in brushed dc motors with the radial component of the MR fringe field. The x-ray tube is oriented such that the radial component of the MR fringe field is orthogonal to the cathode-anode axis. Using a feedback position sensor and the support bearings as electrical slip rings, the authors use electrical commutation to eliminate the need for mechanical brushes and commutators. A vacuum compatible prototype of the proposed motor design was assembled, and its performance was evaluated at various operating conditions. The prototype consisted of a 3.1 in. diameter anode rated at 300 kHU with a ceramic rotor that was 5.6 in. in length and had a 2.9 in. diameter. The material chosen for all ceramic components was MACOR, a machineable glass ceramic developed by Corning Inc. The approximate weight of the entire assembly was 1750 g. The maximum rotation speed, angular acceleration, and acceleration time of the motor design were investigated, as well as the dependence of these parameters on rotor angular offset, magnetic field strength, and field orientation. The resonance properties of the authors' assembly were also evaluated to determine its stability during acceleration, and a pulse width modulation algorithm was implemented to control the rotation speed of the motor. Results: At a magnetic flux density of 41 mT orthogonal to the axis of rotation (on the lower end of the expected flux density in the MR suite) the maximum speed of the motor was found to be 5150 revolutions per minute (rpm). The acceleration time necessary to reach 3000 rpm was found to be approximately 10 s at 59 mT. The resonance frequency of the assembly with the anode attached was 1310 rpm (21.8 Hz) which is far below the desired operating speeds. Pulse width modulation provides an effective method to control the speed of the motor with a resolution of 100 rpm. Conclusions: The proposed design can serve as a direct replacement to the conventional induction motor used in rotating anode x-ray tubes. It does not suffer from a reduced rotation speed when operating in a MR environment. The presence of chromic steel bearings in the prototype prevented testing at the higher field strengths, and future iterations of the design could eliminate this shortcoming. The prototype assembly demonstrates proof of concept of the authors' design and overcomes one of the major obstacles for a MR compatible rotating anode x-ray tube.
Purpose: The appearance of x-ray luminescence computed tomography (XLCT) opens new possibilities to perform molecular imaging by x ray. In the previous XLCT system, the sample was irradiated by a sequence of narrow x-ray beams and the x-ray luminescence was measured by a highly sensitive charge coupled device (CCD) camera. This resulted in a relatively long sampling time and relatively low utilization of the x-ray beam. In this paper, a novel cone beam x-ray luminescence computed tomography strategy is proposed, which can fully utilize the x-ray dose and shorten the scanning time. The imaging model and reconstruction method are described. The validity of the imaging strategy has been studied in this paper. Methods: In the cone beam XLCT system, the cone beam x ray was adopted to illuminate the sample and a highly sensitive CCD camera was utilized to acquire luminescent photons emitted from the sample. Photons scattering in biological tissues makes it an ill-posed problem to reconstruct the 3D distribution of the x-ray luminescent sample in the cone beam XLCT. In order to overcome this issue, the authors used the diffusion approximation model to describe the photon propagation in tissues, and employed the sparse regularization method for reconstruction. An incomplete variables truncated conjugate gradient method and permissible region strategy were used for reconstruction. Meanwhile, traditional x-ray CT imaging could also be performed in this system. The x-ray attenuation effect has been considered in their imaging model, which is helpful in improving the reconstruction accuracy. Results: First, simulation experiments with cylinder phantoms were carried out to illustrate the validity of the proposed compensated method. The experimental results showed that the location error of the compensated algorithm was smaller than that of the uncompensated method. The permissible region strategy was applied and reduced the reconstruction error to less than 2 mm. The robustness and stability were then evaluated from different view numbers, different regularization parameters, different measurement noise levels, and optical parameters mismatch. The reconstruction results showed that the settings had a small effect on the reconstruction. The nonhomogeneous phantom simulation was also carried out to simulate a more complex experimental situation and evaluated their proposed method. Second, the physical cylinder phantom experiments further showed similar results in their prototype XLCT system. With the discussion of the above experiments, it was shown that the proposed method is feasible to the general case and actual experiments. Conclusions: Utilizing numerical simulation and physical experiments, the authors demonstrated the validity of the new cone beam XLCT method. Furthermore, compared with the previous narrow beam XLCT, the cone beam XLCT could more fully utilize the x-ray dose and the scanning time would be shortened greatly. The study of both simulation experiments and physical phantom experiments indicated that the proposed method was feasible to the general case and actual experiments.
Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions: The proposed needle segmentation algorithm is accurate, robust, and suitable for 3D TRUS guided prostate transperineal therapy.