Search NASA⌕ Search

SEARCH · Search NASA

Results for “Package performance study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Turbofan Engine Simulated in a Graphical Simulation Environment

Recently, there has been an increase in the development of intelligent engine technology with advanced active component control. The computer engine models used in these control studies are component-level models (CLM), models that link individual component models of state space and nonlinear algebraic equations, written in a computer language such as Fortran. The difficulty faced in performing control studies on Fortran-based models is that Fortran is not supported with control design and analysis tools, so there is no means for implementing real-time control. It is desirable to have a simulation environment that is straightforward, has modular graphical components, and allows easy access to health, control, and engine parameters through a graphical user interface. Such a tool should also provide the ability to convert a control design into real-time code, helping to make it an extremely powerful tool in control and diagnostic system development. Simulation time management is shown: Mach number versus time, power level angle versus time, altitude versus time, ambient temperature change versus time, afterburner fuel flow versus time, controller and actuator dynamics, collect initial conditions, CAD output, and component-level model: CLM sensor, CAD input, and model output. The Controls and Dynamics Technologies Branch at the NASA Glenn Research Center has developed and demonstrated a flexible, generic turbofan engine simulation platform that can meet these objectives, known as the Modular Aero-Propulsion System Simulation (MAPSS). MAPSS is a Simulink-based implementation of a Fortran-based, modern high pressure ratio, dual-spool, low-bypass, military-type variable-cycle engine with a digital controller. Simulink (The Mathworks, Natick, MA) is a computer-aided control design and simulation package allows the graphical representation of dynamic systems in a block diagram form. MAPSS is a nonlinear, non-real-time system composed of controller and actuator dynamics (CAD) and component-level model (CLM) modules. The controller in the CAD module emulates the functionality of a digital controller, which has a typical update rate of 50 Hz. The CLM module simulates the dynamics of the engine components and uses an update rate of 2500 Hz, which is needed to iterate to balance mass and energy among system components. The actuators in the CAD module use the same sampling rate as those in the CLM. Two graphs of normalized spool speed versus time in seconds and one graph of normalized average metal temperature versus time in seconds is shown. MAPSS was validated via open-loop and closed-loop comparisons with the Fortran simulation. The preceding plots show the normalized results of a closed-loop comparison looking at three states of the model: low-pressure spool speed, high-pressure spool speed, and the average metal temperature measured from the combustor to the high-pressure turbine. In steady state, the error between the simulations is less than 1 percent. During a transient, the difference between the simulations is due to a correction in MAPSS that prevents the gas flow in the bypass duct inlet from flowing forward instead of toward the aft end, which occurs in the Fortran simulation. A comparison between MAPSS and the Fortran model of the bypass duct inlet flow for power lever angles greater than 35 degrees is shown.

Parker, Khary I.↗

Real time side-by-side experimental validation of energy and comfort performance of a zero net energy retrofit package for small commercial buildings

Making buildings zero-net energy (ZNE) is one of the major strategies for achieving carbon emission reduction goals. For this strategy to be successful, it entails a very significant reduction in energy use – 50% or more. In small commercial buildings, however, owners and building management teams usually have limited resources for identifying, analyzing, and procuring appropriate retrofit measures for reducing such use. An approach to overcome this limitation is the development of bundles of energy efficiency measures that can be presented to building owners/operators as a comprehensive package. The research presented in this paper focuses on an experimental evaluation of the impacts of a retrofit package developed for small office buildings in California. Performing this evaluation in a full-scale whole-building integrated systems test facility allowed a side-by-side evaluation in real time, against a reference case, of the impact of the retrofit package not only on energy use but also on visual and thermal comfort. Here, the retrofit package evaluated is comprised of a combination of HVAC, lighting (including daylighting), and plug load measures. The evaluation occurred at different times of the year in order to account for seasonal variations in environmental conditions, including solar angles and weather. The experimental facility allowed testing for two different façade orientations: south and west. Results show that the proposed ZNE retrofit package can save significant amounts of energy for small commercial buildings. During cooling-prevalent periods, total energy savings were 65% for south orientation and 68% for west orientation; during heating-prevalent periods total energy savings were 22% for south orientation and 25% for west orientation. Measurements indicate that the ZNE retrofit package resulted in small but not very significant changes in comfort levels for building occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential vertical movement of large heat-generating waste packages in salt.

With renewed interest in disposal of heat-generating waste in bedded or domal salt formations, scoping analyses were conducted to estimate rates of waste package vertical movement. Vertical movement is found to result from thermal expansion, from upward creep or heave of the near-field salt, and from downward buoyant forces on the waste package. A two-pronged analysis approach was used, with thermal-mechanical creep modeling, and coupled thermal-viscous flow modeling. The thermal-mechanical approach used well-studied salt constitutive models, while the thermal-viscous approach represented the salt as a highly viscous fluid. The Sierra suite of coupled simulation codes was used for both approaches. The waste package in all simulations was a right-circular cylinder with the density of steel, in horizontal orientation. A time-decaying heat generation function was used to represent commercial spent fuel with typical burnup and 50-year age. Results from the thermal-mechanical base case showed approximately 27 cm initial uplift of the package, followed by gradual relaxation closely following the calculated temperature history. A similar displacement history was obtained with the package density set equal to that of salt. The slight difference in these runs is attributable to buoyant displacement (sinking) and is on the order of 1 mm in 2,000 years. Without heat generation the displacement stabilizes at a fraction of millimeter after a few hundred years. Results from thermal-viscous model were similar, except that the rate of sinking was constant after cooldown, at approximately 0.15 mm per 1,000 yr. In summary, all calculations showed vertical movement on the order of 1 mm or less in 2,000 yr, including calculations using well-established constitutive models for temperature-dependent salt deformation. Based on this finding, displacement of waste packages in a salt repository is not a significant repository performance issue.

Clayton, Daniel James↗

Field Results from New Tensor Borehole Optical Fiber Strainmeter Installations in Oklahoma and Utah

The time evolving strain field contains a wealth of information that can be used to interpret subsurface behavior. For example, injecting or removing fluids from reservoirs or aquifers causes deformation that can be used as a diagnostic signal in some cases, while it can interfere with geodetic interpretations in other cases. We've previously demonstrated the feasibility of measuring the strain tensor at a depth of 30m caused by injection into a reservoir at 530m. The observed strain signals were interpreted using four independent analytic and numerical methods that resulted in estimates of the poroelastic properties and geometry of the reservoir that was consistent with data from well logs. However, studies like these are only possible if these deformations can be reliably measured. Years of lab and field work has culminated in the development of a novel borehole strainmeter capable of resolving multiple components of strain using embedded optical fibers configured as Michelson interferometers. It features four horizontal gauges separated by 45° to resolve the horizontal strain tensor as well as a vertical strain gauge and a sixth null component for state-of-health monitoring. The downhole sensing package also includes an open pipe through its center for grout circulation during single-trip deployments and a fully welded stainless steel exterior for robustness and longevity. These instruments have a resolution of 2x10-13 strain that can easily measure the solid earth tides. Preliminary data are available from four strainmeters in shale at our Oklahoma site and four in compacted sand and gravel in Utah. These are deployed from 40-60m, except one of the strainmeters in Oklahoma is deployed at 500m. The data include strains from the initial grout curing, comparisons to predicted earth tide models and in-situ calibration results, barometric pressure admittances and spectral analyses as well as signals from underground injections and surface waves from teleseismic events. Preliminary analyses indicate behavior consistent with other strainmeter deployments, and comparison to data from a Gladwin strainmeter at the Oklahoma site validate the performance of the new design. Analyses from a suite of six well tests at the Oklahoma site show for the first time how the strain tensor field varies with location during well testing.

DeWolf, Scott↗

Visualization Methods for Viability Studies of Inspection Modules for the Space Shuttle

An effective simulation of an object, process, or task must be similar to that object, process, or task. A simulation could consist of a physical device, a set of mathematical equations, a computer program, a person, or some combination of these. There are many reasons for the use of simulators. Although some of the reasons are unique to a specific situation, there are many general reasons and purposes for using simulators. Some are listed but not limited to (1) Safety, (2) Scarce resources, (3) Teaching/education, (4) Additional capabilities, (5) Flexibility and (6) Cost. Robot simulators are in use for all of these reasons. Virtual environments such as simulators will eliminate physical contact with humans and hence will increase the safety of work environment. Corporations with limited funding and resources may utilize simulators to accomplish their goals while saving manpower and money. A computer simulation is safer than working with a real robot. Robots are typically a scarce resource. Schools typically don t have a large number of robots, if any. Factories don t want the robots not performing useful work unless absolutely necessary. Robot simulators are useful in teaching robotics. A simulator gives a student hands-on experience, if only with a simulator. The simulator is more flexible. A user can quickly change the robot configuration, workcell, or even replace the robot with a different one altogether. In order to be useful, a robot simulator must create a model that accurately performs like the real robot. A powerful simulator is usually thought of as a combination of a CAD package with simulation capabilities. Computer Aided Design (CAD) techniques are used extensively by engineers in virtually all areas of engineering. Parts are designed interactively aided by the graphical display of both wireframe and more realistic shaded renderings. Once a part s dimensions have been specified to the CAD package, designers can view the part from any direction to examine how it will look and perform in relation to other parts. If changes are deemed necessary, the designer can easily make the changes and view the results graphically. However, a complex process of moving parts intended for operation in a complex environment can only be fully understood through the process of animated graphical simulation. A CAD package with simulation capabilities allows the designer to develop geometrical models of the process being designed, as well as the environment in which the process will be used, and then test the process in graphical animation much as the actual physical system would be run . By being able to operate the system of moving and stationary parts, the designer is able to see in simulation how the system will perform under a wide variety of conditions. If, for example, undesired collisions occur between parts of the system, design changes can be easily made without the expense or potential danger of testing the physical system.

Mobasher, Amir A.↗

Technical Note: On the calculation of stopping-power ratio for stoichiometric calibration in proton therapy

Purpose: The quantitative effects of assumptions made in the calculation of stopping-power ratios (SPRs) are investigated, for stoichiometric CT calibration in proton therapy. The assumptions investigated include the use of the Bethe formula without correction terms, Bragg additivity, the choice of I-value for water, and the data source for elemental I-values. Methods: The predictions of the Bethe formula for SPR (no correction terms) were validated against more sophisticated calculations using the SRIM software package for 72 human tissues. A stoichiometric calibration was then performed at our hospital. SPR was calculated for the human tissues using either the assumption of simple Bragg additivity or the Seltzer-Berger rule (as used in ICRU Reports 37 and 49). In each case, the calculation was performed twice: First, by assuming the I-value of water was an experimentally based value of 78 eV (value proposed in Errata and Addenda for ICRU Report 73) and second, by recalculating the I-value theoretically. The discrepancy between predictions using ICRU elemental I-values and the commonly used tables of Janni was also investigated. Results: Errors due to neglecting the correction terms to the Bethe formula were calculated at less than 0.1% for biological tissues. Discrepancies greater than 1%, however, were estimated due to departures from simple Bragg additivity when a fixed I-value for water was imposed. When the I-value for water was calculated in a consistent manner to that for tissue, this disagreement was substantially reduced. The difference between SPR predictions when using Janni’s or ICRU tables for I-values was up to 1.6%. Experimental data used for materials of relevance to proton therapy suggest that the ICRU-derived values provide somewhat more accurate results (root-mean-square-error: 0.8% versus 1.6%). Conclusions: The conclusions from this study are that (1) the Bethe formula can be safely used for SPR calculations without correction terms; (2) simple Bragg additivity can be reasonably assumed for compound materials; (3) if simple Bragg additivity is assumed, then the I-value for water should be calculated in a consistent manner to that of the tissue of interest (rather than using an experimentally derived value); (4) the ICRU Report 37 I-values may provide a better agreement with experiment than Janni’s tables.

60 APPLIED LIFE SCIENCES↗

Genarris 2.0: A Random Structure Generator for Molecular Crystals

Genarris is an open source Python package for generating random molecular crystal structures with physical constraints for seeding crystal structure prediction algorithms and training machine learning models. Here we present a new version of the code, containing several major improvements. A MPI-based parallelization scheme has been implemented, which facilitates the seamless sequential execution of user-defined workflows. A new method for estimating the unit cell volume based on the single molecule structure has been developed using a machine-learned model trained on experimental structures. A new algorithm has been implemented for generating crystal structures with molecules occupying special Wyckoff positions. A new hierarchical structure check procedure has been developed to detect unphysical close contacts efficiently and accurately. New intermolecular distance settings have been implemented for strong hydrogen bonds. To demonstrate these new features, we study two specific cases: benzene and glycine. Genarris finds the experimental structures of the two polymorphs of benzene and the three polymorphs of glycine. Program summary Program Title: Genarris 2.0 Program Files doi: http://dx.doi.org/10.17632/grx6mz4pjn.1 Licensing provisions: BSD-3 Clause Programming language: Python, C External routines/libraries: Spglib, ASE, pymatgen, SciPy, mpi4py, scikit-learn, PyTorch, FHI-aims. Nature of problem: Molecular crystal structure prediction. Solution method: Genarris 2.0 generates molecular crystal structures over the 230 space groups, on general and special Wyckoff positions, using physical constraints. Down-sampling of the generated structures may be performed subsequently, based on molecular crystal packing descriptors and an unsupervised machine learning algorithm. Lastly, ab initio structure relaxation may be performed for the final pool. Depending on the user-defined workflow implemented, Genarris may be used to generate diverse molecular crystal datasets to seed evolutionary algorithms or to train machine learning algorithms or as a standalone crystal structure prediction method. Restrictions: For crystal structure generation, the molecule of interest must be semi-rigid with no bond rotational degrees of freedom. Unusual features: Genarris 2.0 is a highly distributed program, making use of MPI for Python parallelization. The user has the ability to design and implement workflows by executing a user-defined list of procedures. Genarris 2.0 offers new features including a machine learning model for estimating the molecular volume in the solid state from the single molecule structure, structure generation in special Wyckoff positions of space groups, hierarchical structure checks including rigorous treatment of non-orthogonal structures, and clustering and down-selection workflows combining first principles simulations with machine learning. (C) 2020 Elsevier B.V. All rights reserved.

Crystal structure prediction↗

RELAP-7 Level 2 Milestone Report: Demonstration of a Steady State Single Phase PWR Simulation with RELAP-7

The document contains the simulation results of a steady state model PWR problem with the RELAP-7 code. The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at Idaho National Laboratory (INL). The code is based on INL's modern scientific software development framework - MOOSE (Multi-Physics Object-Oriented Simulation Environment). This report summarizes the initial results of simulating a model steady-state single phase PWR problem using the current version of the RELAP-7 code. The major purpose of this demonstration simulation is to show that RELAP-7 code can be rapidly developed to simulate single-phase reactor problems. RELAP-7 is a new project started on October 1 st , 2011. It will become the main reactor systems simulation toolkit for RISMC (Risk Informed Safety Margin Characterization) and the next generation tool in the RELAP reactor safety/systems analysis application series (the replacement for RELAP5). The key to the success of RELAP-7 is the simultaneous advancement of physical models, numerical methods, and software design while maintaining a solid user perspective. Physical models include both PDEs (Partial Differential Equations) and ODEs (Ordinary Differential Equations) and experimental based closure models. RELAP-7 will eventually utilize well posed governing equations for multiphase flow, which can be strictly verified. Closure models used in RELAP5 and newly developed models will be reviewed and selected to reflect the progress made during the past three decades. RELAP-7 uses modern numerical methods, which allow implicit time integration, higher order schemes in both time and space, and strongly coupled multi-physics simulations. RELAP-7 is written with object oriented programming language C++. Its development follows modern software design paradigms. The code is easy to read, develop, maintain, and couple with other codes. Most importantly, the modern software design allows the RELAP-7 code to evolve with time. RELAP-7 is a MOOSE-based application. MOOSE (Multiphysics Object-Oriented Simulation Environment) is a framework for solving computational engineering problems in a well-planned, managed, and coordinated way. By leveraging millions of lines of open source software packages, such as PETSC (a nonlinear solver developed at Argonne National Laboratory) and LibMesh (a Finite Element Analysis package developed at University of Texas), MOOSE significantly reduces the expense and time required to develop new applications. Numerical integration methods and mesh management for parallel computation are provided by MOOSE. Therefore RELAP-7 code developers only need to focus on physics and user experiences. By using the MOOSE development environment, RELAP-7 code is developed by following the same modern software design paradigms used for other MOOSE development efforts. There are currently over 20 different MOOSE based applications ranging from 3-D transient neutron transport, detailed 3-D transient fuel performance analysis, to long-term material aging. Multi-physics and multiple dimensional analyses capabilities can be obtained by coupling RELAP-7 and other MOOSE based applications and by leveraging with capabilities developed by other DOE programs. This allows restricting the focus of RELAP-7 to systems analysis-type simulations and gives priority to retain and significantly extend RELAP5's capabilities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PTT System Performance Evaluation in 3-D Imaging of Calibrated Defects: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Research activity in this project is aimed at developing pulsed thermal tomography (PTT) architecture and algorithms for in-service non-destructive examination (NDE) of additively manufactured (AM) reactor components and materials. Recent advances in AM technology could allow cost-efficient fabrication of parts for operating reactors. However, because of stringent safety requirements, long-term performance of AM reactor components needs to be investigated before AM is widely accepted. Because of the complex shapes and significant surface roughness of components due to layer-by-layer welding process in AM, conventional methods might not be useful for in-service NDE of AM components. PTT is ideally suited for in-service NDE of AM metallic components because the method is non-contact, and offers high resolution #-D imaging of material flaws. The objective of this report is to provide initial evaluate of PTT performance sin detecting calibrated flaws in reactor structural materials. Preliminary COMSOL models were developed to conduct super computing simulations of PTT. In the experimental studies, high strength Stainless Steel 316 and Inconel 718 alloys were considered, as well as lower grade Stainless Steel 304, Nickel 200, and Hastelloy C276. Specimens investigated in this report consisted of approximately 1/4in-thick plates made out of these alloys using conventional manufacturing methods. The calibrated defects were created in the form of flat bottom holes (FBH) drilled in metallic plates. The diameters of FBH's varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. The size of the smallest FBH was limited to 1mm because conventional mechanic drills were used for creating the holes. PTT imaging results have shown that 1mm-diameter FBH located 1mm and 2mm below the surface were detectable. Larger size FBH were detectable at greater depth. For example, 6mm-diameter FBH could be detected at 8mm depth. Image contrast varied slightly between the specimens, with the best reconstructions obtained in SS316 and C276 plates. In addition, a 2/3in-thick Inconel 718 nozzle plate produced with additive manufacturing method was imaged with PTT. It was shown that PTT can scan through the plate in approximately 20s. Several modes of 3-D data visualization were explored, including using ImageJ and MATLAB software packages.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Study of Shape Memory Polymer Based Slat-Cove Filler

Aircraft noise reduction is an application of current intense interest for which smart materials show significant potential. Specifically, the aeroacoustic noise produced by the unsteady aerodynamic flow about the leading-edge high-lift device, such as leading-edge slat, of typical transport-aircraft wings is of particular interest. Concepts with the most promise to mitigate this noise source, most notably the slat-cove filler concept, have focused on highly reconfigurable structures that change shape between different phases of the flight envelope. These shape changes often involve large deformation, which has stimulated the consideration of shape memory materials. In recent years, shape memory materials (SMMs) have drawn greater interest for applications such as smart fabrics, intelligent medical devices, self-deployable space structures, morphing structures and packaging. Compared to other shape memory materials, like shape memory alloys (SMAs) or shape memory ceramics (SMCs), shape memory polymers (SMPs) have desirable advantages such as high elastic deformation to enable large shape change, broad tailorability of mechanical properties, potential biocompatibility and biodegradability, ductility, light weight and ease of processing. However, SMPs still have some critical disadvantages such as insufficient mechanical and thermal characteristics for structural applications, low recovery stress, and long response time. The new LaRC shape memory thermosetting polymer composite (LaRC-SMPC) discussed herein was synthesized with nontoxic monomers and conductive/magnetic fillers to yield enhanced thermal/mechanical characteristics and faster response times. LaRC-SMPCs with a variety of fiber reinforcements [Kevlar®, carbon fiber (standard and thin-ply), and carbon-nanotube (CNT) sheet] were fabricated to tailor the physical properties and test for suitability as a slat-cove filler (SCF). The performance of SCF prototypes fabricated with the developed LaRC-SMPCs was evaluated using a bench-top test apparatus. The SCFs made of Kevlar® fiber fabric or carbon fiber fabric infused shape memory polymer composite (SMPC) exhibited kinking during simulated deployment and stowage, which can be problematic during operation. The SCF made of CNT sheet/SMP composite did not exhibit kinking, but the deployment was sluggish compared to carbon fiber fabric/SMP composite. This report documents the evolution of designing SMPCs as slat-cove fillers for aircraft noise reduction. In the course of the investigation, several 2 approaches were investigated to address shortcomings in material characteristics based on performance requirements of operational slat-cove fillers.

Kang, Jin Ho↗

Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for a Modular, Scalable Passive Cooling System in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected passive, modular localized cooling solution provided by vendor 4. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a passive, modular, scalable liquid cooling system in this study. The scope is to quantify energy performance of the modular cooling unit corresponding to various server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OVERVIEW OF ENHANCED HANFORD SINGLE-SHELL TANK (SST) INTEGRITY PROJECT - 12128

To improve the understanding of the single-shell tanks integrity, Washington River Protection Solutions, LLC, the USDOE Hanford Site tank contractor, developed an enhanced Single-Shell Tank (SST) Integrity Project in 2009. An expert panel on SST integrity, consisting of various subject matters experts in industry and academia, was created to provide recommendations supporting the development of the project. This panel developed 33 recommendations in four main areas of interest: structural integrity, liner degradation, leak integrity and prevention, and mitigation of contamination migration, Seventeen of these recommendations were used to develop the basis for the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order, which is also known as the Tri-Party Agreement. The change package identified two phases of work for SST integrity. The initial phase has been focused on efforts to envelope the integrity of the tanks. The initial phase was divided into two primary areas of investigation: structural integrity and leak integrity. If necessary based on the outcome from the initial work, a second phase would be focused on further definition of the integrity of the concrete and liners. Combined these two phases are designed to support the formal integrity assessment of the Hanford SSTs in 2018 by Independent Qualified Registered Engineer. The work to further define the DOE's understanding of the structural integrity SSTs involves preparing a modern Analysis of Record using a finite element analysis program. Structural analyses of the SSTs have been conducted since 1957, but these analyses used analog calculation, less rigorous models, or focused on individual structures. As such, an integrated understanding of all of the SSTs has not been developed to modern expectations. In support of this effort, other milestones will address the visual inspection of the tank concrete and the collection of concrete core samples from the tanks for analysis of current mechanics properties. The work on the liner leak integrity has examined the leaks from 23 tanks with liner failures. Individual leak assessments are being developed for each tank to identify the leak cause and location. Also a common cause study is being performed to take the data from individual tanks to look for trends in the failure. Supporting this work is an assessment of the leak rate from tanks at both Hanford and the Savannah River Site and a new method to locate leak sites in tank liner using ionic conductivity. A separate activity is being conducted to examine the propensity for corrosion in select single shell tanks with aggressive waste layers. The work for these two main efforts will provide the basis for the phase two planning. If the margins identified aren't sufficient to ensure the integrity through the life of the mission, phase two would focus on activities to further enhance the understanding of tank integrity. Also coincident with any phase-two work would be the integrity analysis for the tanks, which would be complete in 2018. With delays in the completion of waste treatment facilities at Hanford, greater reliance on safe, continued storage of waste in the single shell tanks is increased in importance. The goal of integrity assessment would provide basis to continue SST activities till the end of the treatment mission.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Biolink Implantable Telemetry System

Most biotelemetry applications deal with the moderated data rates of biological signals. Few people have studied the problem of transcutaneous data transmission at the rates required by NASA's Life Sciences-Advanced BioTelemetry System (LS-ABTS). Implanted telemetry eliminate the problems associated with wire breaking the skin, and permits experiments with awake and unrestrained subjects. Our goal is to build a low-power 174-216MHz Radio Frequency (RF) transmitter suitable for short range biosensor and implantable use. The BioLink Implantable Telemetry System (BITS) is composed of three major units: an Analog Data Module (ADM), a Telemetry Transmitter Module (TTM), and a Command Receiver Module (CRM). BioLink incorporates novel low-power techniques to implement a monolithic digital RF transmitter operating at 100kbps, using quadrature phase shift keying (QPSK) modulation in the 174-216MHz ISM band. As the ADM will be specific for each application, we focused on solving the problems associated with a monolithic implementation of the TTM and CRM, and this is the emphasis of this report. A system architecture based on a Frequency-Locked Loop (FLL) Frequency Synthesizer is presented, and a novel differential frequency that eliminates the need for a frequency divider is also shown. A self sizing phase modulation scheme suitable for low power implementation was also developed. A full system-level simulation of the FLL was performed and loop filter parameters were determined. The implantable antenna has been designed, simulated and constructed. An implant package compatible with the ABTS requirements is also being proposed. Extensive work performed at 200MHz in 0.5um complementary metal oxide semiconductors (CMOS) showed the feasibility of integrating the RF transmitter circuits in a single chip. The Hajimiri phase noise model was used to optimize the Voltage Controlled Oscillator (VCO) for minimum power consumption. Two test chips were fabricated in a 0.5pm, 3V CMOS process. Measured phase noise for a 1.5mW, 200MHz ring oscillator VCO is -80dBc/Hz at 100KHZ offset, showing good agreement with the theory. We also propose a novel superregenerative receiver architecture for implementing the command receiver. The superregenerative receiver's simplicity, low cost, and low power consumption has made it the receiver of choice for short-distance data communications, remote control and home automation. We present the design of a superregenerative AM receiver implemented in a 0.5um CMOS technology that operates at 433.92MHz and dissipates only 300uW. Further work entails detailed transistor-level design of the FLL and superregenerative receiver and a monolithic implementation of an implantable transceiver in 0.5um CMOS technology.

Betancourt-Zamora, Rafael J.↗

Methodology for the Incorporation of Passive Component Aging Modeling into the RAVEN/ RELAP-7 Environment

Passive system, structure and components (SSCs) will degrade over their operation life and this degradation may cause to reduction in the safety margins of a nuclear power plant. In traditional probabilistic risk assessment (PRA) using the event-tree/fault-tree methodology, passive SSC failure rates are generally based on generic plant failure data and the true state of a specific plant is not reflected realistically. To address aging effects of passive SSCs in the traditional PRA methodology [1] does consider physics based models that account for the operating conditions in the plant, however, [1] does not include effects of surveillance/inspection. This paper represents an overall methodology for the incorporation of aging modeling of passive components into the RAVEN/RELAP-7 environment which provides a framework for performing dynamic PRA. Dynamic PRA allows consideration of both epistemic and aleatory uncertainties (including those associated with maintenance activities) in a consistent phenomenological and probabilistic framework and is often needed when there is complex process/hardware/software/firmware/ human interaction [2]. Dynamic PRA has gained attention recently due to difficulties in the traditional PRA modeling of aging effects of passive components using physics based models and also in the modeling of digital instrumentation and control systems. RAVEN (Reactor Analysis and Virtual control Environment) [3] is a software package under development at the Idaho National Laboratory (INL) as an online control logic driver and post-processing tool. It is coupled to the plant transient code RELAP-7 (Reactor Excursion and Leak Analysis Program) also currently under development at INL [3], as well as RELAP 5 [4]. The overall methodology aims to: • Address multiple aging mechanisms involving large number of components in a computational feasible manner where sequencing of events is conditioned on the physical conditions predicted in a simulation environment such as RELAP-7. • Identify the risk-significant passive components, their failure modes and anticipated rates of degradation • Incorporate surveillance and maintenance activities and their effects into the plant state and into component aging progress. • Asses aging affects in a dynamic simulation environment 1. C. L. SMITH, V. N. SHAH, T. KAO, G. APOSTOLAKIS, “Incorporating Ageing Effects into Probabilistic Risk Assessment –A Feasibility Study Utilizing Reliability Physics Models,” NUREG/CR-5632, USNRC, (2001). 2. T. ALDEMIR, “A Survey of Dynamic Methodologies for Probabilistic Safety Assessment of Nuclear Power Plants, Annals of Nuclear Energy, 52, 113-124, (2013). 3. C. RABITI, A. ALFONSI, J. COGLIATI, D. MANDELLI and R. KINOSHITA “Reactor Analysis and Virtual Control Environment (RAVEN) FY12 Report,” INL/EXT-12-27351, (2012). 4. D. ANDERS et.al, "RELAP-7 Level 2 Milestone Report: Demonstration of a Steady State Single Phase PWR Simulation with RELAP-7," INL/EXT-12-25924, (2012).

97 MATHEMATICS AND COMPUTING↗

Experimentally informed structure optimization of amorphous TiO 2 films grown by atomic layer deposition

Amorphous titanium dioxide TiO 2 (a-TiO 2 ) has been widely studied, particularly as a protective coating layer on semiconductors to prevent corrosion and promote electron–hole conduction in photoelectrochemical reactions. The stability and longevity of a-TiO 2 is strongly affected by the thickness and structural heterogeneity, implying that understanding the structure properties of a-TiO 2 is crucial for improving the performance. This study characterized the structural and electronic properties of a-TiO 2 thin films (~17 nm) grown on Si by atomic layer deposition (ALD). Fluctuation spectra V(k) and angular correlation functions were determined with 4-dimensional scanning transmission electron microscopy (4D-STEM), which revealed the distinctive medium-range ordering in the a-TiO 2 film. A realistic atomic model of a-TiO 2 was established guided by the medium-range ordering and the previously reported short-range ordering of a-TiO 2 film, as well as the interatomic potential. The structure was optimized by the StructOpt code using a genetic algorithm that simultaneously minimizes energy and maximizes the match to experimental short- and medium-range ordering. The StructOpt a-TiO 2 model presents improved agreements with the medium-range ordering and the k-space location of the dominant 2-fold angular correlations compared with a traditional melt-quenched model. The electronic structure of the StructOpt a-TiO 2 model was studied by ab initio calculations and compared to the crystalline phases and experimental results. Finally, this work uncovered the medium-range ordering in a-TiO 2 thin films and provided a realistic a-TiO 2 structure model for further investigation of structure–property relationships and materials design. In addition, the improved multi-objective optimization package StructOpt was provided for structure determination of complex materials guided by experiments and simulations.

36 MATERIALS SCIENCE↗

Jake Garn Mission Simulator and Training Facility, Building 5, Historical Documentation

In response to President George W. Bush's announcement in January 2004 that the Space Shuttle Program (SSP) would end in 2010, the National Aeronautics and Space Administration (NASA) completed a nation-wide historical survey and evaluation of NASA-owned facilities and properties (real property assets) at all its Centers and component facilities. The buildings and structures which supported the SSP were inventoried and assessed as per the criteria of eligibility for listing in the National Register of Historic Places (NRHP) in the context of this program. This study was performed in compliance with Section 110 of the National Historic Preservation Act (NHPA) of 1966 (Public Law 89-665), as amended; the National Environmental Policy Act (NEPA) of 1969 (Public Law 91-190); Executive Order (EO) 11593: Protection and Enhancement of the Cultural Environment; EO 13287, Preserve America, and other relevant legislation. As part of this nation-wide study, in September 2006, historical survey and evaluation of NASA-owned and managed facilities at was conducted by NASA's Lyndon B. Johnson Space Center (JSC) in Houston, Texas. The results of this study are presented in a report entitled, "Survey and Evaluation of NASA-owned Historic Facilities and Properties in the Context of the U.S. Space Shuttle Program, Lyndon B. Johnson Space Center, Houston, Texas," prepared in November 2007 by NASA JSC's contractor, Archaeological Consultants, Inc. As a result of this survey, the Jake Gam Mission Simulator and Training Facility (Building 5) was determined eligible for listing in the NRHP, with concurrence by the Texas State Historic Preservation Officer (SHPO). The survey concluded that Building 5 is eligible for the NRHP under Criteria A and C in the context of the U.S. Space Shuttle program (1969-2010). Because it has achieved significance within the past 50 years, Criteria Consideration G applies. At the time of this documentation, Building 5 was still used to support the SSP as an astronaut training facility. This documentation package precedes any undertaking as defined by Section 106 of the NHPA, as amended, and implemented in 36 CFR Part 800, as NASA JSC has decided to proactively pursue efforts to mitigate the potential adverse affects of any future modifications to the facility. It includes a historical summary of the Space Shuttle program; the history of JSC in relation to the SSP; a narrative of the history of Building 5 and how it supported the SSP; and a physical description of the structure. In addition, photographs documenting the construction and historical use of Building 5 in support of the SSP, as well as photographs of the facility documenting the existing conditions, special technological features, and engineering details, are included. A contact sheet printed on archival paper, and an electronic copy of the work product on CD, are also provided.

Slovinac, Trish↗

Benchmark Calculation for Surry Unit 1 Cycles 1-3 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

The benchmark calculations were performed for Surry Unit 1 cycles 1–3 to validate the SCALE 6.3/Polaris–Purdue Advanced Reactor Core Simulator (PARCS) v3.4.2 with the ENDF/B–VII.1 56–group library by comparing the simulated results with the measured data. The benchmark results will be used to evaluate uncertainties of the SCALE/Polaris–PARCS code package for pressurized water reactor physics analysis for key nuclear parameters such as reactivity, control bank worth, temperature coefficients, and pin and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS, and PARCS. Additional details are provided for the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used in evaluating uncertainties with other benchmark results for key nuclear parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗