IDC Re-Engineering Phase 2 Iteration E1 Use Cases version 1.1.
This document contains 21 use cases generated from the model contained in Rational Software Architect.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This document contains 21 use cases generated from the model contained in Rational Software Architect.
This document contains 21 use cases generated from the model contained in Rational Software Architect.
The creation of a handheld unit to utilize the Cristallini method of uranium hexafluoride sampling requires the identification and qualification of suitable substrate materials. These materials will need to quickly and completely react with the process gas, resist vapor locking under vacuum, while being relatively inexpensive and homogeneous. Two forms of powdered alumina have been chosen for a head-to-head comparison during upcoming uranium hexafluoride tests. Both materials have shown ideal uptake characteristics during tungsten hexafluoride tests with a high loading capacity and no measureable breakthrough. They have also been shown to work well at vacuums below 10 Torr, are commercially available and inexpensive. In addition, two possible hydrogen fluoride trapping materials, sodium fluoride and saturated calcium carbonate, have been identified for further testing.
The goal of the NEAMS neutronics effort is to develop a neutronics toolkit for use on sodium-cooled fast reactors (SFRs) which can be extended to other reactor types. The neutronics toolkit includes the high-fidelity deterministic neutron transport code PROTEUS and many supporting tools such as a cross section generation code MC 2 -3, a cross section library generation code, alternative cross section generation tools, mesh generation and conversion utilities, and an automated regression test tool. The FY16 effort for NEAMS neutronics focused on supporting the release of the SHARP toolkit and existing and new users, continuing to develop PROTEUS functions necessary for performance improvement as well as the SHARP release, verifying PROTEUS against available existing benchmark problems, and developing new benchmark problems as needed. The FY16 research effort was focused on further updates of PROTEUS-SN and PROTEUS-MOCEX and cross section generation capabilities as needed.
Frequently our most basic research experiments stimulate solutions for some of the most intractable national security problems, such as nuclear weapons stewardship, homeland security, intelligence and information analysis, and nuclear and alternative energy. This publication highlights our talented and creative staff who deliver solutions to these complex scientific and technological challenges by conducting cutting-edge multidisciplinary physical science research.
A partially loaded dry storage cask was imaged using cosmic ray muons. Since the cask is large relative to the size of the muon tracking detectors, the instruments were placed at nine different positions around the cask to record data covering the entire fuel basket. We show that this technique can detect the removal of a single fuel assembly from the center of the cask.
In the United States, spent nuclear fuel (SNF) is safely and securely stored in spent fuel pools and dry storage casks. The available capacity in spent fuel pools across the nuclear fleet has nearly reached a steady state value. The excess SNF continues to be loaded in dry storage casks. Fuel is expected to remain in dry storage for periods beyond the initial dry cask certification period of 20 years. Recent licensing renewals have approved an additional 40 years. This report identifies the current requirements and evaluation techniques associated with the safeguards and security of SNF dry cask storage. A set of knowledge gaps is identified in the current approaches. Finally, this roadmap identifies known knowledge gaps and provides a research path to deliver the tools and models needed to close the gaps and allow the optimization of the security and safeguards approaches for an interim spent fuel facility over the lifetime of the storage site.
Magnetic Microcalorimeters (MMCs) are gamma-ray detectors with an energy resolution 10x higher than high-purity germanium detectors. They can increase the accuracy of non-destructive analysis of nuclear materials, enable the detection of new isotopes (e.g. Pu-242 of U-236), and improve nuclear data in cases where Ge detectors are limited by line overlap. MMCs consist of a magnetic sensor operated at temperatures below 50 mK, and they infer gamma-ray energies from the change in magnetization due to the temperature increase after gamma-ray absorption. The goal of this project is to further increase the energy resolution and sensitivity of MMC gamma detectors.
Research was carried out investigating the feasibility of using a regional distance seismic waveform moment tensor inverse procedure to estimate source parameters of nuclear explosions and to use the source inversion results to develop a source-type discrimination capability. The results of the research indicate that it is possible to robustly determine the seismic moment tensor of nuclear explosions, and when compared to natural seismicity in the context of the a Hudson et al. (1989) source-type diagram they are found to separate from populations of earthquakes and underground cavity collapse seismic sources.
This report provides an overview of the scenarios used in strategic futures workshops conducted at Sandia on September 21 and 29, 2016. The workshops, designed and facilitated by analysts in Center 100, used scenarios to enable thought leaders to think collectively about the changing aspects of global nuclear security and the potential implications for the US Government and Sandia National Laboratories.
Sandia National Laboratories has prepared a project development plan that proposes how the parties interested in the IDC Re-Engineering system will coordinate its development, testing and transition to operations.
A joint effort has been initiated by Los Alamos National Laboratory (LANL), Oak Ridge National Laboratory (ORNL), Savanah River National Laboratory (SRNL), Pacific Northwest National Laboratory (PNNL), sponsored by the National Nuclear Security Administration’s (NNSA’s) office of Proliferation Detection, to develop and validate a flexible framework for simulating effluents and emissions from spent fuel reprocessing facilities. These effluents and emissions can be measured by various on-site and/or off-site means, and then the inverse problem can ideally be solved through modeling and simulation to estimate characteristics of facility operation such as the nuclear material production rate. The flexible framework called Facility Modeling Toolkit focused on the forward modeling of PUREX reprocessing facility operating conditions from fuel storage and chopping to effluent and emission measurements.
This document only provides a cursory summary of the “Iran Deal” where all stipulations are not listed.
The National Nuclear Security Administration’s Office of Nuclear Smuggling Detection and Deterrence (NSDD) has facilitated the installation of more than 3,500 radiation portal monitors (RPMs) at 606 sites in 56 countries worldwide. This collection of RPMs represents the world’s largest network of radiation detectors and provides one element in the defense-in-depth approach that supports the Global Nuclear Detection Architecture. These systems support NSDD’s mission to build partner country capability to deter, detect, and interdict the illicit transport of radiological and fissile material through strategic points of entry and exit at seaports, airports, and border crossings. NSDD works collaboratively with partner countries and international organizations to optimize the operation of these RPMs. The large amount of data provided by NSDD partner countries highlights the close cooperation and partnerships NSDD has built with 56 countries around the world. Thirty-seven of these countries shared at least some RPM-related data with NSDD in fiscal year 2016. This significant level of data sharing is a key element that distinguishes the NSDD office as unique among nuclear nonproliferation programs and initiatives: NSDD can provide specific, objective, data-driven decisions and support for sustaining the radiation detection systems it helped deploy. This data analysis report summarizes and aggregates the RPM data provided to the NSDD office for analysis and review in fiscal year 2016. The data can be used to describe RPM performance and characterize the wide diversity of NSDD deployment sites. For example, NSDD deploys detector systems across sites with natural background radiation levels that can vary by a factor of approximately six from site to site. Some lanes have few occupancies, whereas others have approximately 8,000 occupancies per day and the different types of cargo that travel through a site can result in site-wide alarm rates that range from near 0% at some sites to above 3% at others. Based on the data received, the global average uptime for NSDD RPMs was above 96% for fiscal year 2016. NSDD takes all of these factors into account in making recommendations to partner countries on how to most effectively manage and maintain site operations. NSDD utilizes reports and other information products created by data analysts to efficiently allocate the resources needed to detect and ultimately interdict illicit nuclear and radiological material.
No abstract provided.
Antineutrinos are highly penetrating particles emitted by the fission process in operating nuclear power and research reactors. Their rate of emission and energy spectrum can provide useful information about reactor operations, including the existence of the reactor, its power level, and the fissile mass inventories in the core. Because the signal cannot be attenuated or masked, this information can be gathered at long standoff outside the core. Building on our group’s successful experimental demonstrations of plutonium content monitoring at 25 meters from a reactor core, the goal of this project is to demonstrate detectors for reactor monitoring and discovery detectors at increasing standoffs, out to a practical limit of about 1000 kilometers. Our two main goals for FY16 and 17 are: 1) design a detector capable of monitoring nuclear reactor operations at 25 kilometer standoff, and 2) engage in a cooperative effort to monitor a former plutonium production reactor in India (at close range).
Cerium oxide (CeO2) dust is recommended as a surrogate for plutonium oxide (PuO2) in airborne release fraction experiments. The total range of applicable particle sizes for PuO2 extends from 0.0032 μm (the diameter of a single PuO2 molecule) to 10 μm (the defined upper boundary for respirable particles). For particulates with a physical particle diameter of 1.0 μm, the corresponding aerodynamic diameters for CeO2 and PuO2 are 2.7 μm and 3.4 μm, respectively. Cascade impactor air samplers are capable of measuring the size distributions of CeO2 or PuO2 particulates. In this document, the aerodynamic diameters for CeO2 and PuO2 were calculated for seven different physical diameters (0.0032, 0.02, 0.11, 0.27, 1.0, 3.2, and 10 μm). For cascade impactor measurements, CeO2 and PuO2 particulates with the same physical diameter would be collected onto the same or adjacent collection substrates. The difference between the aerodynamic diameter of CeO2 and PuO2 particles (that have the same physical diameter) is 39% of the resolution of a twelve-stage MSP Inc. 125 cascade impactor, and 34% for an eight-stage Andersen impactor. An approach is given to calculate the committed effective dose (CED) coefficient for PuO2 aerosol particles, compared to a corresponding aerodynamic diameter of CeO2 particles. With this approach, use of CeO2 as a surrogate for PuO2 material would follow a direct conversion based on a molar equivalent. In addition to the analytical information developed for this document, several US national labs have published articles about the use of CeO2 as a PuO2 surrogate. Different physical and chemical aspects were considered by these investigators, including thermal properties, ceramic formulations, cold pressing, sintering, molecular reactions, and mass loss in high temperature gas flows. All of those US national lab studies recommended the use of CeO2 as a surrogate material for PuO2.
Presenting along with Introductory Nonproliferation Teaching and Learning Module to provide an intro to working at LANL at Utah State on February 21, 2017.