Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power system stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Exploration Exercise System (EES) Development

Exploration class missions will be required to have an exercise device that is lightweight, has a small footprint, and is capable of providing enough physical stimulus and exercise variability to be an effective countermeasure against muscle and bone loss that results from the microgravity environment. Exploration exercise device prototypes should be evaluated on the ground and in-orbit for feasibility of use in microgravity for long and short duration exploration missions and efficacy of the device to maintain multi-system health and performance. The European Enhanced Exploration Exercise Device (E4D) was selected as the exploration prototype device to be evaluated on ISS for efficacy and feasibility of use as a single multi-modality device for the exercise system for exploration missions. This effort supports the continued development, testing, and verification of E4D hardware and software, internal NASA integration (Human Health and Performance, ISS Vehicle Office, Engineering, and Flight Operations), and external integration across NASA, ESA, and the Danish Aerospace Company (DAC). Providing a feasibility and acceptability assessment from a physiological efficacy and hardware durability standpoint are critical for informing use and risk associated with use on exploration missions. Clearly defined objectives from end users, stakeholders, and Subject Matter Experts (SMEs) will be tested by crewmembers during acute use sessions and long duration use of the exercise device while on ISS. This effort will include a flight study where crewmembers will be asked to exercise using only the E4D during the duration of their mission and participate in a battery of physiological testing to evaluate the efficacy. Hardware is scheduled to launch in FY25 followed by 2 years of operational use after activation and checkout. A final recommendation will be provided to the Artemis program on acceptability of the device for exploration missions. The E4D needs a vibration isolation stabilization (VIS) system that serves as a platform for the exercise hardware to protect the vehicle from loads imparted during exercise. Exploration forward VIS systems will need to protect the vehicle and provide sufficient stabilization for the exerciser during performance of all critical exercises. These enabling capabilities need to be achieved within exploration vehicle power, thermal, mass, and volume limitations.

Kent Lawrence Kalogera↗

Frequency threshold determination for frequency-responsive load controllers

Systems, methods, and computer media for managing frequency response in a power grid are provided herein. Individual grid-connected electrical devices can be turned on and/or off by corresponding frequency-responsive load controllers when frequency deviations beyond a threshold are detected. Each controller selects, for the corresponding electrical device, a frequency threshold from available frequencies in a frequency range. If the selected frequency falls within a deadband frequency range, then the controller sets the frequency threshold to a frequency outside of the deadband (e.g., to a closest available frequency outside of the deadband). On a system-wide level, this approximates a uniform distribution of frequency thresholds over the entire frequency range, including the deadband, and achieves the proper power-to-frequency relationship for grid stability. A supervisory coordinator can determine the frequency range from which a frequency threshold is selected based on aggregated power information for devices and controllers throughout the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Role of reinforcement learning for risk-based robust control of cyber-physical energy systems

Critical infrastructures such as cyber-physical energy systems (CPS-E) integrate information flow and physical operations that are vulnerable to natural and targeted failures. Safe, secure, and reliable operation and control of CPS-E is critical to ensure societal well-being and economic prosperity. Automated control is key for real-time operations and may be mathematically cast as a sequential decision-making problem under uncertainty. Emergence of data-driven techniques for decision making under uncertainty, such as reinforcement learning (RL), have led to promising advances for addressing sequential decision-making problems for risk-based robust CPS-E control. However, existing research challenges include understanding the applicability of RL methods across diverse CPS-E applications, addressing the effect of risk preferences across multiple RL methods, and development of open-source domain-aware simulation environments for RL experimentation within a CPS-E context. This article systematically analyzes the applicability of four types of RL methods (model-free, model-based, hybrid model-free and model-based, and hierarchical) for risk-based robust CPS-E control. Problem features and solution stability for the RL methods are also discussed. We demonstrate and compare the performance of multiple RL methods under different risk specifications (risk-averse, risk-neutral, and risk-seeking) through the development and application of an open-source simulation environment. Motivating numerical simulation examples include representative single-zone and multizone building control use cases. Finally, six key insights for future research and broader adoption of RL methods are identified, with specific emphasis on problem features, algorithmic explainability, and solution stability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heat exchanger temperature response for duty-cycle transients in the NGNP/HTE.

Control system studies were performed for the Next Generation Nuclear Plant (NGNP) interfaced to the High Temperature Electrolysis (HTE) plant. Temperature change and associated thermal stresses are important factors in determining plant lifetime. In the NGNP the design objective of a 40 year lifetime for the Intermediate Heat Exchanger (IHX) in particular is seen as a challenge. A control system was designed to minimize temperature changes in the IHX and more generally at all high-temperature locations in the plant for duty-cycle transients. In the NGNP this includes structures at the reactor outlet and at the inlet to the turbine. This problem was approached by identifying those high-level factors that determine temperature rates of change. First are the set of duty cycle transients over which the control engineer has little control but which none-the-less must be addressed. Second is the partitioning of the temperature response into a quasi-static component and a transient component. These two components are largely independent of each other and when addressed as such greater understanding of temperature change mechanisms and how to deal with them is achieved. Third is the manner in which energy and mass flow rates are managed. Generally one aims for a temperature distribution that minimizes spatial non-uniformity of thermal expansion in a component with time. This is can be achieved by maintaining a fixed spatial temperature distribution in a component during transients. A general rule of thumb for heat exchangers is to maintain flow rate proportional to thermal power. Additionally the product of instantaneous flow rate and heat capacity should be maintained the same on both sides of the heat exchanger. Fourth inherent mechanisms for stable behavior should not be compromised by active controllers that can introduce new feedback paths and potentially create under-damped response. Applications of these principles to the development of a plant control strategy for the reference NGNP/HTE plant can be found in the body of this report. The outcome is an integrated plant/control system design. The following conclusions are drawn from the analysis: (1) The plant load schedule can be managed to maintain near-constant hot side temperatures over the load range in both the nuclear and chemical plant. (2) The reactor open-loop response is inherently stable resulting mainly from a large Doppler temperature coefficient compared to the other reactivity temperature feedbacks. (3) The typical controller used to manage reactor power production to maintain reactor outlet temperature at a setpoint introduces a feedback path that tends to destabilize reactor power production in the NGNP. (4) A primary loop flow controller that forces primary flow to track PCU flow rate is effective in minimizing spatial temperature differentials within the IHX. (5) Inventory control in both the primary and PCU system during ramp load change transients is an effective means of maintaining high NGNP thermal efficiency while at reduced electric load. (6) Turbine bypass control is an effective means for responding to step changes in generator load when equipment capacity limitations prevent inventory control from being effective. (7) Turbine bypass control is effective in limiting PCU shaft over speed for the loss of generator load upset event. (8) The proposed control strategy is effective in limiting time variation of the differential spatial temperature distribution in the IHX during transients. Essentially the IHX can be made to behave in a manner where each point in the IHX experiences approximately the same temperature rate of change during a transient. (9) The stability of the closed-loop Brayton cycle was found to be sensitive to where one operates on the turbo-machine performance maps. There are competing interests: more stable operation means operating on the curves at points that reduce overall cycle efficiency. Future work should address in greater detail elements that came to light in the course of this work. Specifically: (1) A stability analysis should be performed to identify the phenomena that control reactor outlet temperature stability when operating with the Reactor Outlet Temperature Controller. The goal is to identify a better performing controller. (2) Future simulations should be performed with multiple axial nodes. The single axial node model for the core used in this work gives rise to an initial core reactor outlet temperature perturbation that is a numerical artifact. (3) The tradeoffs referred to above regarding the dependence of Brayton cycle stability and efficiency on performance curve characteristics and use need to be better understood. (4) The role of xenon was neglected in this work and needs to be included in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electro-mechanical Modeling of Wind Turbine and Energy Storage Systems with Enhanced Inertial Response

In this paper, a coordinated control scheme for wind turbine generator (WTG) and supercapacitor energy storage system (ESS) is proposed for temporary frequency supports. Inertial control is designed by using generator torque limit considering the security of WTG system, while ESS releases its energy to compensate the sudden active power deficit during the recovery process of turbine rotor. WTG is modeled using the fatigue, aerodynamic, structure, turbulence (FAST) code, which identifies the mechanical loadings of the turbine and addresses electro-mechanical interactions in the wind energy system. A damping controller is augmented to the inertial control to suppress severe mechanical oscillations in the shaft and tower of the turbine during frequency supports. Furthermore, the result of small-signal stability analysis shows that the WTG-ESS tends to improve the stability of the whole multi-energy power grid. The major contributions of this paper will be validated by utilizing the proposed control method that combines the grid support capability and maintaining the integrity of structural design of the turbine for normal operations.

17 WIND ENERGY↗

Development of a super high speed motor-generator and controller

To develop a super high speed motor-generator, it is essential to deal with magnetic analysis, dynamic analysis, and experimental evaluation of the heart of the MTG (Microturbine Generator) system, the motor-generator. An amorphous core is applied to a stator core for reduction of iron loss at high speed, and the motor-generator is analyzed with considerations focused on magnetic losses and the statistical optimum design. The performance of the amorphous core is validated by the analysis and experiment by back-to-back tests considering the AC load. Rotor dynamics is performed for dynamic stability at high speed using transient analysis orbit diagrams and compared with the experimental results. The simulation results of the generator are compared with the experiment. Also a super high speed controller of the MTG system is developed using a sensorless algorithm, power stack, gate driver, digital signal processing, analog circuit, and radiation heat design. Based on these results, a high speed motor-generator and controller are successfully developed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tilt-proprotor perspective

The general tilt-proprotor concept is discussed, and a more detailed look at the XV-15 aircraft is taken. The special features of the two-engine system, engine control system, and flight control system are mentioned. The main objectives of the XV-15 program are to (1) verify rotor/pylon/wing/dynamic stability and aircraft performance over a representative operational envelope, (2) assess the handling qualities and establish a safe operating envelope, and (3) investigate gust sensitivity, effects of downwash, and hover operation. With regard to rotor/pylon stability, one challenge is to be able to predict a parameter's value and then build hardware to match. The analytical program has gained some respect through aeroelastic and full-scale XV-3 demonstrations. Special concern centers around the thrust and power management system when flying at high speed when very small changes in rotor collective pitch represent large changes in thrust and power. Demonstration of the system awaits wind-tunnel and flight testing.

Few, D. D.↗

Techno-economic analysis of the impact of dynamic electricity prices on solar penetration in a smart grid environment with distributed energy storage

This study investigates the technical and economic feasibility of using high levels of solar energy penetration up to 400 MW into a smart grid system of 60,000 smart houses. A novel non-cooperative Stackelberg game is introduced that incorporates the profitability of the supply-side and helps in solving problems related to overgeneration and photovoltaic curtailment. The non-cooperative game is intended to find the optimal dynamic prices that would leverage distributed storage through the demand-side to stabilize the power grid operation. Ten cases are studied with five photovoltaic plant sizes and two battery designs. Here, a novel quantitative analysis of high levels of solar penetration as a percentage of the total electricity demand is introduced to evaluate the technical feasibility of the studied cases. To evaluate the economic viability of the proposed smart grid system, four metrics were used: the levelized cost of energy, the levelized cost of storage, the payback period, and the net present value. Two out of ten studied cases were concluded to be the most promising cases, one with a solar photovoltaic plant size of 200 MW and the other with 300 MW. The case with 300 MW solar plant is preferred as it paves the way for more solar energy deployment with a solar penetration percentage up to 67.78%. This case had a payback period of 10.72 years and a net present value of $\$51.44$ M for the solar plant and a payback period of 12.06 years and a net present value of $\$40.75$ M for the demand-side.

14 SOLAR ENERGY↗

Analytical Approach for Estimating Preliminary Mass of ARES I Crew Launch Vehicle Upper Stage Structural Components

In January 2004, President Bush gave the National Aeronautics and Space Administration (NASA) a vision for Space Exploration by setting our sight on a bold new path to go back to the Moon, then to Mars and beyond. In response to this vision, NASA started the Constellation Program, which is a new exploration launch vehicle program. The primary mission for the Constellation Program is to carry out a series of human expeditions ranging from Low Earth Orbit to the surface of Mars and beyond for the purposes of conducting human exploration of space, as specified by the Vision for Space Exploration (VSE). The intent is that the information and technology developed by this program will provide the foundation for broader exploration activities as our operational experience grows. The ARES I Crew Launch Vehicle (CLV) has been designated as the launch vehicle that will be developed as a "first step" to facilitate the aforementioned human expeditions. The CLV Project is broken into four major elements: First Stage, Upper Stage Engine, Upper Stage (US), and the Crew Exploration Vehicle (CEV). NASA's Marshall Space Flight Center (MSFC) is responsible for the design of the CLV and has the prime responsibility to design the upper stage of the vehicle. The US is the second propulsive stage of the CLV and provides CEV insertion into low Earth orbit (LEO) after separation from the First Stage of the Crew Launch Vehicle. The fully integrated Upper Stage is a mix of modified existing heritage hardware (J-2X Engine) and new development (primary structure, subsystems, and avionics). The Upper Stage assembly is a structurally stabilized cylindrical structure, which is powered by a single J-2X engine which is developed as a separate Element of the CLV. The primary structure includes the load bearing liquid hydrogen (LH2) and liquid oxygen (LOX) propellant tanks, a Forward Skirt, the Intertank structure, the Aft Skirt and the Thrust Structure. A Systems Tunnel, which carries fluid and electrical power functions to other Elements of the CLV, is included as secondary structure. The MSFC has an overall responsibility for the integrated US element as well as structural design an thermal control of the fuel tanks, intertank, interstage, avionics, main propulsion system, Reaction Control System (RCS) for both the Upper Stage and the First Stage. MSFC's Spacecraft and Vehicle Department, Structural and Analysis Design Division is developing a set of predicted mass of these elements. This paper details the methodology, criterion and tools used for the preliminary mass predictions of the upper stage structural assembly components. In general, weight of the cylindrical barrel sections are estimated using the commercial code Hypersizer, whereas, weight of the domes are developed using classical solutions. HyperSizer is software that performs automated structural analysis and sizing optimization based on aerospace methods for strength, stability, and stiffness. Analysis methods range from closed form, traditional hand calculations repeated every day in industry to more advanced panel buckling algorithms. Margin-of-safety reporting for every potential failure provides the engineer with a powerful insight into the structural problem. Optimization capabilities include finding minimum weight panel or beam concepts, material selections, cross sectional dimensions, thicknesses, and lay-ups from a library of 40 different stiffened and sandwich designs and a database of composite, metallic, honeycomb, and foam materials. Multiple different concepts (orthogrid, isogrid, and skin stiffener) were run for multiple loading combinations of ascent design load with and with out tank pressure as well as proof pressure condition. Subsequently, selected optimized concept obtained from Hypersizer runs was translated into a computer aid design (CAD) model to account for the wall thickness tolerance, weld land etc for developing the most probable weight of the components. The flow diram summarizes the analysis steps used in developing these predicted mass.

Aggarwal, Pravin↗

Control Design of Series-connected PV-powered Grid-forming Converters via Singular Perturbation

We report modular architectures that consist of several series-connected dc-ac converters have been a focal point of recent innovations in transformerless medium-voltage applications. In this paper, we consider an architecture consisting of dc-ac modules containing a quadruple active bridge dc-dc converter, which generates three floating dc links that feed grid-side dc-ac inverters. Practical implementation of such a converter module in PV systems requires a variety of controllers that collectively achieve maximum power point tracking, dc-link regulation, and ac-side power control. Design of such multi-loop systems is generally quite challenging due to the potential for destabilizing interactions among loops. Here we propose a design approach where singular perturbation theory is used to decompose the timescales at which each control loop operates and provides a systematic framework for parametric selection. Our approach also ensures system stability of multiple modules with identical controls connected in series across a grid. The paper concludes with experimental results of three 1000 W series-connected converter modules across a stiff grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TRANSIT TIMING OBSERVATIONS FROM KEPLER. II. CONFIRMATION OF TWO MULTIPLANET SYSTEMS VIA A NON-PARAMETRIC CORRELATION ANALYSIS

We present a new method for confirming transiting planets based on the combination of transit timing variations (TTVs) and dynamical stability. Correlated TTVs provide evidence that the pair of bodies is in the same physical system. Orbital stability provides upper limits for the masses of the transiting companions that are in the planetary regime. This paper describes a non-parametric technique for quantifying the statistical significance of TTVs based on the correlation of two TTV data sets. We apply this method to an analysis of the TTVs of two stars with multiple transiting planet candidates identified by Kepler. We confirm four transiting planets in two multiple-planet systems based on their TTVs and the constraints imposed by dynamical stability. An additional three candidates in these same systems are not confirmed as planets, but are likely to be validated as real planets once further observations and analyses are possible. If all were confirmed, these systems would be near 4:6:9 and 2:4:6:9 period commensurabilities. Our results demonstrate that TTVs provide a powerful tool for confirming transiting planets, including low-mass planets and planets around faint stars for which Doppler follow-up is not practical with existing facilities. Continued Kepler observations will dramatically improve the constraints on the planet masses and orbits and provide sensitivity for detecting additional non-transiting planets. If Kepler observations were extended to eight years, then a similar analysis could likely confirm systems with multiple closely spaced, small transiting planets in or near the habitable zone of solar-type stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Paralleling of LLC Resonant Converters

The LLC resonant converter is a popular, variable switching frequency DC-DC converter that may be controlled using two methods: charge and frequency control. In this paper, the application of LLC resonant converters to input-parallel, output-parallel system is studied. In this respect, the models of output-port I-V characteristics and small-signal output impedance of the charge controlled LLC converter are proposed. In addition, a mathematical framework is developed for droop-based paralleled DC-DC systems. Here, it distinctly identifies the output DC voltage and circulating current modes of stability, even in systems comprising of non-identical converters.

42 ENGINEERING↗

Modeling and Feedback Compensator Design for Power-Hardware-in-the-Loop System for Medium-Voltage Grid-Connected Power Converters

Hardware-in-the-loop (HIL) evaluation is a method in which the test subject is split into a physical part and a simulated part, and these parts are connected with interfaces to form a combined physical-numerical system. Power-hardware-in-the-loop (PHIL) systems, where actual hardware is connected to a real-time model, can exhibit issues of instability, inaccuracy and errors when operating in a closed-loop. The challenges of generating a PHIL setup are that, first, because of the limited dynamic response of the different parts of the system, the test results might be inaccurate, and, second, because of the high frequency noise introduced by the sensors to the closed-loop system, it can be difficult to design a compensator for the real-time emulator response, while stabilizing the closed-loop system at the same time. In this paper, different parts of a PHIL system are characterized, and the feedback compensator system design is proposed for the stable operation of the closed-loop PHIL system. The issues as observed in a PHIL system without any compensator are demonstrated using experimental results, and the effectiveness of a first order phase lead compensator is validated.

compensator design↗

Strategies to improve phase-stability of ultrafast swept source optical coherence tomography for single shot imaging of transient mechanical waves at 16 kHz frame rate

We present single-shot phase-sensitive imaging of propagating mechanical waves within tissue, enabled by an ultrafast optical coherence tomography (OCT) system powered by a 1.628 MHz Fourier domain mode-locked (FDML) swept laser source. We propose a practical strategy for phase-sensitive measurement by comparing the phases between adjacent OCT B-scans, where the B-scan contains a number of A-scans equaling an integer number of FDML buffers. With this approach, we show that micro-strain fields can be mapped with ∼3.0 nm sensitivity at ∼16 000 fps. The system's capabilities are demonstrated on porcine cornea by imaging mechanical wave propagation launched by a pulsed UV laser beam, promising non-contact, real-time, and high-resolution optical coherence elastography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of Synthesis Gas Concentration, Composition, and Operational Time on Tubular Solid Oxide Fuel Cell Performance

There is tremendous potential to utilize the exhaust gases and heat already present within combustion chambers to generate electrical power via solid oxide fuel cells (SOFCs). Variations in system design have been investigated as well as thorough examinations into the impacts of environmental conditions and fuel composition/concentration on SOFC performance. In an attempt to isolate the impacts of carbon monoxide and hydrogen concentration ratios within the exhaust stream, this work utilizes multi-temperature performance analyses with simulated methane combustion exhaust as fuel combined with dilute hydrogen baseline tests. These comparisons reveal the impacts of the complex reaction pathways carbon monoxide participates in when used as an SOFC fuel. Despite these complexities, performance reductions as a result of the presence of carbon monoxide are low when compared to similarly dilute hydrogen as a fuel. This provides further motivation for the continued development of SOFC-CHP systems. Stability testing performed over 80 h reveals the need for careful control of the operating environment as well as signs of carbon deposition. As a result of gas flow disruption, impacts of anode oxidation that may normally not hinder power production become significant factors in addition to coarsening of the anode material. Thermal management and strategies to minimize these impacts are a topic of future research.

54 ENVIRONMENTAL SCIENCES↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters: Preprint

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Performance Testing of a High Temperature Linear Alternator for Stirling Convertors

The NASA Glenn Research Center has conducted performance testing of a high temperature linear alternator (HTLA) in support of Stirling power convertor development for potential future Radioisotope Power Systems (RPS). The high temperature linear alternator is a modified version of that used in Sunpower's Advanced Stirling Convertor (ASC), and is capable of operation at temperatures up to 200 deg. Increasing the temperature capability of the linear alternator could expand the mission set of future Stirling RPS designs. High temperature Neodymium-Iron-Boron (Nd-Fe-B) magnets were selected for the HTLA application, and were fully characterized and tested prior to use. Higher temperature epoxy for alternator assembly was also selected and tested for thermal stability and strength. A characterization test was performed on the HTLA to measure its performance at various amplitudes, loads, and temperatures. HTLA endurance testing at 200 deg is currently underway.

Radioisotope Power System↗