Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Development of computer program NAS3D using Vector processing for geometric nonlinear analysis of structures

An algorithm for vectorized computation of stiffness matrices of an 8 noded isoparametric hexahedron element for geometric nonlinear analysis was developed. This was used in conjunction with the earlier 2-D program GAMNAS to develop the new program NAS3D for geometric nonlinear analysis. A conventional, modified Newton-Raphson process is used for the nonlinear analysis. New schemes for the computation of stiffness and strain energy release rates is presented. The organization the program is explained and some results on four sample problems are given. The study of CPU times showed that savings by a factor of 11 to 13 were achieved when vectorized computation was used for the stiffness instead of the conventional scalar one. Finally, the scheme of inputting data is explained.

Mangalgiri, P. D.↗

Microbial biofilm studies of the environmental control and life support system water recovery test for Space Station Freedom

NASA is developing a water recovery system (WRS) for Space Station Freedom to reclaim human waste water for reuse by astronauts as hygiene or potable water. A water recovery test (WRT) currently in progress investigates the performance of a prototype of the WRS. Analysis of biofilm accumulation, the potential for microbially influenced corrosion (MIC) in the WRT, and studies of iodine disinfection of biofilm are reported. Analysis of WRT components indicated the presence of organic deposits and biofilms in selected tubing. Water samples for the WRT contained acid-producing and sulfate-reducing organisms implicated in corrosion processes. Corrosion of an aluminum alloy was accelerated in the presence of these water samples; however, stainless steel corrosion rates were not accelerated. Biofilm iodine sensitivity tests using an experimental laboratory scale recycled water system containing a microbial check valve (MCV) demonstrated that an iodine concentration of 1 to 2 mg/L was ineffective in eliminating microbial biofilm. For complete disinfection, an initial concentration of 16 mg/L was required, which was gradually reduced by the MCV over 4 to 8 hours to 1 to 2 mg/L. This treatment may be useful in controlling biofilm formation.

Rodgers, E. B.↗

Microbial biofilm studies of the Environmental Control and Life Support System water recovery test for Space Station Freedom

Analysis of biofilm accumulation, studies of iodine disinfection of biofilm, and the potential for microbially influenced corrosion in the water recovery test (WRT) are presented. The analysis of WRT components showed the presence of biofilms and organic deposits in selected tubing. Water samples from the WRT contained sulfate-reducing and acid-producing organisms implicated in corrosion processes. Corrosion of an aluminum alloy was accelerated in the presence of these water samples, but stainless steel corrosion rates were not accelerated.

Obenhuber, D. C.↗

Analysis Of Delays In Simulation Of Flight

Report presents analysis of delays in transport of signals through various subsystems and components of flight-simulation system. Addresses all parts of simulation process and system, from analog-to-digital conversion and sampling of pilot's command input, through multiple sampling rate digital processing via transfer-function mathematical models of responses of simulated aircraft and of simulation system itself, to system output sampled at same rate as pilot's command input.

Mcfarland, R. E.↗

System performance and on-orbit operations of the Crystal Growth Furnace (CGF) on the first United States microgravity laboratory mission

The paper discusses the design, the performance, and on-orbit operations of the Crystal Growth Furnace (CGF) system flown for the first time aboard the Orbiter Columbia on STS-50. Four experiments were carried out: (1) crystal growth of (Hg,Zn)Te by chemical vapor transport, (2) seeded Bridgman growth of Zn-doped CdTe, (3) Bridgman growth of Se-doped GaAs, and (4) crystal growth of (Hg,Zn)Te by directional solidification. The results of a system performance data analysis demonstrate that all the elements of the CGF system functioned flawlessly. Seven out of eight samples carried on board yielded the best possible science return to date, surpassing previous microgravity material processing experiments in space.

Srinivas, R.↗

Succinonitrile Purification Facility

The Succinonitrile (SCN) Purification Facility provides succinonitrile and succinonitrile alloys to several NRA selected investigations for flight and ground research at various levels of purity. The purification process employed includes both distillation and zone refining. Once the appropriate purification process is completed, samples are characterized to determine the liquidus and/or solidus temperature, which is then related to sample purity. The lab has various methods for measuring these temperatures with accuracies in the milliKelvin to tenths of milliKelvin range. The ultra-pure SCN produced in our facility is indistinguishable from the standard material provided by NIST to well within the stated +/- 1.5mK of the NIST triple point cells. In addition to delivering material to various investigations, our current activities include process improvement, characterization of impurities and triple point cell design and development. The purification process is being evaluated for each of the four vendors to determine the efficacy of each purification step. We are also collecting samples of the remainder from distillation and zone refining for analysis of the constituent impurities. The large triple point cells developed will contain SCN with a melting point of 58.0642 C +/- 1.5mK for use as a calibration standard for Standard Platinum Resistance Thermometers (SPRTs).

Source record↗

A Control Chart Approach for Representing and Mining Data Streams with Shape Based Similarity

The mining of data streams for online condition monitoring is a challenging task in several domains including (electric) power grid system, intelligent manufacturing, and consumer science. Considering a power grid application in which thousands of sensors, called the phasor measurement units, are deployed on the power grid network to continuously collect streams of digital data for real-time situational awareness and system management. Depending on design, each sensor could stream between ten and sixty data samples per second. The myriad of sensory data captured could convey deeper insights about sequence of events in real-time and before major damages are done. However, the timely processing and analysis of these high-velocity and high-volume data streams is a challenge. Hence, a new data processing and transformation approach, based on the concept of control charts, for representing sequence of data streams from sensors is proposed. In addition, an application of the proposed approach for enhancing data mining tasks such as clustering using real-world power grid data streams is presented. The results indicate that the proposed approach is very efficient for data streams storage and manipulation.

big data↗

Assessment and Non-Destructive Evaluation of the Influence of Residual Solvent on a Two-Part Epoxy-Based Adhesive Using Ultrasonics

Polymers are increasingly being used in higher demanding applications due to their ability to tailor the properties of structures while allowing for a weight and cost reduction. Solvents play an important role in the manufacture of polymeric structures since they allow for a reduction in the polymer’s viscosity or assist with the dispersion of fillers into the polymer matrix. However, the incorrect removal of the solvent affects both the physical and chemical properties of polymeric materials. The presence of residual solvent can also negatively affect the curing kinetics and the final quality of polymers. Destructive testing is mainly performed to characterize the properties of these materials. However, this type of testing involves using lab-type equipment that cannot be taken in-field to perform in situ testing and requires a specific sample preparation. Here, a method is presented to non-destructively evaluate the curing process and final viscoelastic properties of polymeric materials using ultrasonics. In this study, changes in longitudinal sound speed were detected during the curing of an aerospace epoxy adhesive as a result of variations in polymer chemistry. To simulate the presence of residual solvent, samples containing different weight percentages of isopropyl alcohol were manufactured and tested using ultrasonics. Thermogravimetric analysis was used to show changes in the decomposition of the adhesive due to the presence of IPA within the polymer structure. Adding 2, 4, and 6 wt.% of IPA decreased the adhesive’s lap shear strength by 40, 58, and 71%, respectively. Ultrasonics were used to show how the solvent influenced the curing process and the final sound speed of the adhesive. Young’s modulus and Poisson’s ratio were determined using both the longitudinal and shear sound speeds of the adhesive. Using ultrasonics has the potential to non-invasively characterize the quality of polymers in both an in-field and manufacturing settings, ensuring their reliability during use in demanding applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lower Temperature Annealing of Vapor Diffused Nb₃Sn for Accelerator Cavities

Nb₃Sn is a next-generation superconducting material for the accelerator cavities with higher critical temperature and superheating field, both twice compared to Nb. It promises superior performance and higher operating temperature than Nb, resulting in significant cost reduction. So far, the Sn vapor diffusion method is the most preferred and successful technique to coat niobium cavities with Nb₃Sn. Although several post-coating techniques (chemical, electrochemical, mechanical) have been explored to improve the surface quality of the coated surface, an effective process has yet to be found. Since there are only a few studies on the post-coating heat treatment at lower temperatures, we annealed Nb₃Sn-coated samples at 800 C - 1000 C to study the effect of heat treatments on surface properties, primarily aimed at removing surface Sn residues. This paper discusses the systematic surface analysis of coated samples after annealing at temperatures between 850 C and 950 C.

43 PARTICLE ACCELERATORS↗

Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS

The ability to directly measure uranium isotope ratios on environmental swipes has been achieved through a solution-based microextraction process and represents a significant advancement toward the development of a rapid method to analyze international nuclear safeguard samples. Here, a microextraction probe is lowered and sealed onto the swipe surface, and analytes within the sampling site (~8 mm2) are dissolved and extracted into a flowing solvent of 2% nitric acid (HNO 3 ). The mobilized species are subsequently directed into an inductively coupled plasma-mass spectrometer (ICP-MS) for accurate and precise isotope ratio determination. This work highlights the novelty of the sampling mechanism, particularly with the direct coupling of the microextraction probe to the ICP-MS and measurement of uranium isotope ratios. The preliminary method detection limit for the microextraction-ICP-MS method, utilizing a quadrupole-based MS, was determined to be ~50 pg of 238 U. Additionally, precise and accurate isotope ratio measurements were achieved on uranium reference materials for both the major ( 235 U/ 238 U) and minor ( 234 U/ 238 U and 236 U/ 238 U) ratios. While the present work is focused on directly measuring uranium isotopic systems on swipe surfaces for nuclear safeguards and verification applications, the benefits would extend across many applications in which direct solid sampling is sought for elemental and isotopic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CFD Analysis of RLUOB Zone 1 HEPA Filter Plenum and Testing Manifolds

The purpose of this computational fluid dynamics (CFD) analysis is to ensure that Camfil Farr’s upstream and downstream injection and sampling manifolds can meet or exceed the requirements outlined in the ASME AG-1 1997 a(2000) Code on Nuclear Air and Gas Treatment for the testing of HEPA and adsorbent filters. This paper will present a numerical simulation of airflow in the Radiological Laboratory Utility Office Building (RLUOB) zone 1 HEPA filter plenum and testing manifolds using the commercial CFD software ANSYS FLUENT 2020R1. The CFD analysis focuses on the investigation of the air flow distribution and air-aerosol mixing uniformity. The evaluation was done for all steps of the modeling process: grid generation, physics setup, simulation, and post-processing. The mass flow rate in each section of the zone 1 injection and sampling manifolds is also reported.

42 ENGINEERING↗

Tuning the Magnetic Properties of ZnFe{sub 2}O{sub 4} Nanoparticles Through Partial Doping and Annealing

The aim of this study was to investigate the effect of annealing temperature and cobalt cation (Co{sup 2+}) doping on the magnetic properties of zinc ferrite (ZFO) nanoparticles. The nanoparticles were prepared through sol-gel combustion process with citric acid as the fuel. The obtained nanoparticles were annealed at several temperatures from 300 to 1000 °C for 2 h. Spinel formation was proved by X-ray diffraction (XRD) patterns, and the average crystallite size in all samples was estimated between 22 and 32 nm. It is worthwhile to mention that Fe{sub 2}O{sub 3} and ZnO are detected as the medium phases. Meanwhile, Fe{sub 2}O{sub 3} phase transformation to the other allotropes has happened around 400 °C and was characterized via the simultaneous thermal analysis (STA) and XRD. For higher annealing temperatures, diffusion has gradually been completed and, finally, the single phase of spinel structure was prepared at 1000 °C. In addition, field-emission scanning electron microscopy (FESEM) images revealed that the nanoparticle size after annealing was between 30 and 200 nm for the whole samples. The formation of the spinel phase was considered the most important factor on the magnetic properties of ZFO. Cobalt doping, annealing temperature, and also Fe{sub 2}O{sub 3} phase were the main factors on changing magnetic properties. Paramagnetic nanoparticles with higher coercivity for doped samples rather than un-doped samples have been obtained.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Application of the Uranium–Helium Chronometer to the Analysis of Nuclear Forensic Materials

Radiochronometers are used to constrain the manufacturing and processing history of actinide materials for nuclear forensic investigations. This paper describes here U–He ages and He diffusion kinetics obtained from a metallic, highly enriched uranium sample. The average U–He age is 8% older than the known casting date, which indicates that excess He is present and is likely due to incomplete degassing of pre-existing He during the casting process. Although the U–He age is older than expected, the accuracy is comparable to other chronometers that have been applied to this material. Diffusion kinetics obtained from the uranium metal indicate that He is quantitatively retained under plausible storage conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Combined XRD/XRF Instrument for Lunar Resource Assessment

Robotic surface missions to the Moon should be capable of measuring mineral as well as chemical abundances in regolith samples. Although much is already known about the lunar regolith, our data are far from comprehensive. Most of the regolith samples returned to Earth for analysis had lost the upper surface, or it was intermixed with deeper regolith. This upper surface is the part of the regolith most recently exposed to the solar wind; as such it will be important to resource assessment. In addition, it may be far easier to mine and process the uppermost few centimeters of regolith over a broad area than to engage in deep excavation of a smaller area. The most direct means of analyzing the regolith surface will be by studies in situ. In addition, the analysis of the impact-origin regolith surfaces, the Fe-rich glasses of mare pyroclastic deposits, are of resource interest, but are inadequately known; none of the extensive surface-exposed pyroclastic deposits of the Moon have been systematically sampled, although we know something about such deposits from the Apollo 17 site. Because of the potential importance of pyroclastic deposits, methods to quantify glass as well as mineral abundances will be important to resource evaluation. Combined x ray diffraction (XRD) and x ray fluorescence (XRF) analysis will address many resource characterization problems on the Moon. XRF methods are valuable for obtaining full major-element abundances with high precision. Such data, collected in parallel with quantitative mineralogy, permit unambiguous determination of both mineral and chemical abundances where concentrations are high enough to be of resource grade. Collection of both XRD and XRF data from a single sample provides simultaneous chemical and mineralogic information. These data can be used to correlate quantitative chemistry and mineralogy as a set of simultaneous linear equations, the solution of which can lead to full characterization of the sample. The use of Rietveld methods for XRD data analysis can provide a powerful tool for quantitative mineralogy and for obtaining crystallographic data on complex minerals.

Vaniman, D. T.↗

Extreme-Scale Distribution-Based Data Analysis

Scientists overview and identify regions of interest by transforming data into compact information descriptors that characterize simulation results and allow detailed analysis on demand. Among many existing feature descriptors, statistical information derived from data samples is a promising approach to taming the big data avalanche because data distributionscomputed from a population can compactly describe the presence and characteristics of salient data features with minimal data movement. The ability to computationally summarize and process data using distributions also provides an efficient and representative capture of information that can adjust to size and resource constraints, with the added benefit that uncertainty associated with results can be quantified and communicated. In this project, we have developed a distribution-based data analysis and visualization framework for optimizing in situ processing and analysis of extreme-scale scientific data.

97 MATHEMATICS AND COMPUTING↗

Sensitivity analysis, surrogate modeling, and optimization of pebble-bed reactors considering normal and accident conditions

This research provides a valuable tool that streamlines the optimization process while significantly increasing its accuracy. This study creates a robust framework for reactor design optimization by incorporating comprehensive modeling using the Comprehensive Reactor Analysis Bundle, or BlueCRAB, within the Multiphysics Object-Oriented Simulation Environment (MOOSE). BlueCRAB is the United States Nuclear Regulatory Commission's code suite for non-light water reactor analysis and includes the Griffin, Pronghorn, and Bison applications. This not only improves the efficiency of the optimization process but also enhances the reliability of the results. Such a tool is essential for advancing the state-of-the-art in pebble-bed reactor technology and is critical for achieving the goals of Generation IV reactors, which aim for safe, sustainable, and economically viable nuclear energy solutions. This work presents and applies this workflow on pebble-bed reactors while considering both normal and off-normal conditions. A representative gas-cooled pebble-bed reactor at equilibrium core conditions serves as the nominal design specification for normal operation and is based on previous research. The depressurized loss-of-forced-cooling accident is deployed for off-normal conditions in this work. After defining design-related parameters and quantities of interest regarding reactor safety and performance, this multiphysics model is sampled using the MOOSE stochastic tools module. The result is a comprehensive dataset of configurations, enabling sensitivity analysis and the generation of surrogate models. Subsequently, the dataset and surrogate models are employed in two optimization studies aimed at maximizing fuel utilization and economic profit while adhering to safety and operational constraints. Performing the optimization process with fuel utilization as the metric leads to an improvement of approximately 10%, compared to engineering-judgment-based nominal conditions. The optimization on economic profit leads to an estimated increase of ~300 million USD over the lifetime of the reactor.

97 MATHEMATICS AND COMPUTING↗

Automated instant labeling chemistry workflow for real-time monitoring of monoclonal antibody N -glycosylation

With the transition toward continuous bioprocessing, process analytical technology (PAT) is becoming necessary for rapid and reliable in-process monitoring during biotherapeutics manufacturing. Bioprocess 4.0 is looking to build end-to-end bioprocesses that include PAT-enabled real-time process control. This is especially important for drug product quality attributes that can change during bioprocessing, such as protein N-glycosylation, a critical quality attribute for most monoclonal antibody (mAb) therapeutics. Glycosylation of mAbs is known to influence their efficacy as therapeutics and is regulated for a majority of mAb products on the market today. Currently, there is no method to truly measure N-glycosylation using on-line PAT, hence making it impractical to design upstream process control strategies. We recently described the N-GLYcanyzer workflow: an integrated PAT unit that measures mAb N-glycosylation within 3 hours of automated sampling from a bioreactor. Here, we integrated Agilent's Instant Procainamide (InstantPC) based chemistry workflow into the N-GLYcanyzer PAT unit to allow for nearly 10× faster near real-time analysis of mAb glycoforms. Furthermore, our methodology is explained in detail to allow for replication of the PAT workflow as well as present a case study demonstrating the use of this PAT to autonomously monitor a mammalian cell perfusion process at the bench scale to gain increased knowledge of mAb glycosylation dynamics during continuous biologics manufacturing using Chinese hamster ovary (CHO) cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wet-chemical etching of FIB lift-out TEM lamellae for damage-free analysis of 3-D nanostructures

Reducing ion beam damage from the focused ion beam (FIB) during fabrication of cross sections is a well-known challenge for materials characterization, especially cross sectional characterization of nanostructures. To address this, a new method has been developed for cross section fabrication enabling high resolution transmission electron microscopy (TEM) analysis of 3-D nanostructures free of surrounding material and free of damage detectable by TEM analysis. Before FIB processing, nanopillars are encapsulated in a sacrificial oxide which acts as a protective layer during FIB milling. Furthermore, the cross sectional TEM lamella containing the nanopillars is then mounted and thinned with some modifications to conventional FIB sample preparation that provide stability for the lamella during the following wet-chemical dip etch. The wet-chemical etch of the TEM lamella removes the sacrificial oxide layer, freeing the nanopillars from any material that would obscure TEM imaging. Both high resolution TEM and aberration corrected scanning TEM images of Si/SiGe pillars with diameters down to 30 nm demonstrate the successful application of this approach.

3-d nanostructure analysis↗