Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Volume-selective magnetic resonance imaging using an adjustable, single-sided, portable sensor

Portable, single-sided NMR sensors can operate under conditions inaccessible to conventional NMR while featuring lower cost, portability, and the ability to analyze arbitrary-sized objects. Such sensors can nondestructively probe the interior of samples by collecting images and measuring relaxation and diffusion constants,and, given careful shimming schemes, even perform chemical analysis. The inherently strong magnetic-field gradients of single-sided sensors developed so far has prevented imaging of materials with high water content, such as biological tissues, over large volumes whereas designs with more homogeneous fields suffer from low field strength and typically cannot probe volumes larger than 10 cm3. We present a design with a continuously adjustable sensitive volume, enabling the effective volume to be enlarged several fold. This process allows for imaging in reasonable times of much bigger objects and opens the door to the possibility of clinical imaging with portable sensors. We demonstrate MRI in axial and saggital planes, at different depths of the sensitive volume and T1-weighted contrast in a tissue sample.

47 OTHER INSTRUMENTATION↗

Common processes drive the thermochemical pretreatment of lignocellulosic biomass

Lignocellulosic biomass, a potentially important renewable organic source of energy and chemical feedstock, resists degradation to glucose in industrial hydrolysis processes and thus requires expensive thermochemical pretreatments. Understanding the mechanism of biomass breakdown during these pretreatments will lead to more efficient use of biomass. By combining multiple probes of structure, sensitive to different length scales, with molecular dynamics simulations, we reveal two fundamental processes responsible for the morphological changes in biomass during steam explosion pretreatment: cellulose dehydration and lignin-hemicellulose phase separation. In conclusion, we further show that the basic driving forces are the same in other leading thermochemical pretreatments, such as dilute acid pretreatment and ammonia fiber expansion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Casting Process Modeling and Validation

Computational simulations of gravity casting for metallic U-Pu-Zr nuclear fuel rods were performed with the free surface flow solver Flow3d. Two different casting apparatus designs were explored for studying the effects on the final cast rod profiles. Experimental data for the casting problem obtained from Idaho National Laboratory (INL) was validated with numerical simulations on one of the designs considered. The volume of the rods cast, length of the rods, and temperature profiles were predicted through the transient casting process and were found to match closely with experimental data. A sensitivity analysis with vent locations, pressure, mesh refinement, and effects of surface tension at the interface were explored. This work serves as a validation benchmark for the casting problem and provides guidelines when performing simulation exercises for modeling casting. This paper also provides the mathematical framework to enabling modeling of the casting process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling for calculation of vanadium oxide film composition in reactive-sputtering process

A modified model describing the changing ratio of vanadium to oxide on the target and substrate as a function of oxygen flow is described. Actually, this ratio is extremely sensitive to the deposition conditions during the vanadium oxide (VO{sub x}) reactive magnetron-sputtering process. The method in this article is an extension of a previously presented Berg's model, where only a single stoichiometry compound layer was taken into consideration. This work deals with reactive magnetron sputtering of vanadium oxide films with different oxygen contents from vanadium metal target. The presence of vanadium mixed oxides at both target and substrate surface produced during reactive-sputtering process are included. It shows that the model can be used for the optimization of film composition with respect to oxygen flow in a stable hysteresis-free reactive-sputtering process. A systematic experimental study of deposition rate of VO{sub x} with respect to target ion current was also made. Compared to experimental results, it was verified that the theoretical calculation from modeling is in good agreement with the experimental counterpart.

36 MATERIALS SCIENCE↗

HIGH-EFFICIENCY AUTONOMOUS LASER ADAPTIVE OPTICS

As new large-scale astronomical surveys greatly increase the number of objects targeted and discoveries made, the requirement for efficient follow-up observations is crucial. Adaptive optics imaging, which compensates for the image-blurring effects of Earth's turbulent atmosphere, is essential for these surveys, but the scarcity, complexity and high demand of current systems limit their availability for following up large numbers of targets. To address this need, we have engineered and implemented Robo-AO, a fully autonomous laser adaptive optics and imaging system that routinely images over 200 objects per night with an acuity 10 times sharper at visible wavelengths than typically possible from the ground. By greatly improving the angular resolution, sensitivity, and efficiency of 1-3 m class telescopes, we have eliminated a major obstacle in the follow-up of the discoveries from current and future large astronomical surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

How sensitive is Hawking radiation to superluminal dispersion relations?

We discuss the Hawking radiation process in a collapse scenario with superluminal dispersion relations. Due to these superluminal modifications, the horizon effectively becomes frequency-dependent. At every moment of the collapse, a critical frequency can be calculated such that frequencies higher than this critical frequency do not couple to the collapsing geometry and hence do not see any horizon. We discuss three important consequences. First, the late-time radiation in general has a lower intensity than in the standard Hawking picture. Second, the thermal output spectrum depends on the surface gravity, thereby effectively exploring the physics inside the black hole. Third, the radiation dies off as time advances.

79 ASTRONOMY AND ASTROPHYSICS↗

Fabrication of sub-12 nm thick silicon nanowires by processing scanning probe lithography masks

Silicon nanowires are key elements to fabricate very sensitive mechanical and electronic devices. We provide a method to fabricate sub-12 nm silicon nanowires in thickness by combining oxidation scanning probe lithography and anisotropic dry etching. Extremely thin oxide masks (0.3–1.1 nm) are transferred into nanowires of 2–12 nm in thickness. The width ratio between the mask and the silicon nanowire is close to one which implies that the nanowire width is controlled by the feature size of the nanolithography. This method enables the fabrication of very small single silicon nanowires with cross-sections below 100 nm{sup 2}. Those values are the smallest obtained with a top-down lithography method.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Nanorods and nanoparticles of titanium dioxide and their use in dye sensitized solar cells

Mesoporous TiO{sub 2} nanorods/nanorods were successfully synthesized by hydrothermal process at 170 °C for 72 hr. The powder X-ray diffraction pattern shows large fraction of anatase phase with good crystalline behavior of the prepared materials. The specific surface area and pore volume of the synthesized material are about 84.83 m{sup 2}/g and 0.1316 cc/g respectively. The morphological results show that the TiO{sub 2} nanorods had diameter of ~ 25 nm and the length of ~ 80 nm. The nanoparticles have 20 nm in size. The current-voltage curve shows that the synthesized TiO{sub 2} nanostructure results in 36.7 % higher solar cell efficiency than commercial P25.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cold-Season Precipitation Sensitivity to Microphysical Parameterizations: Hydrologic Evaluations Leveraging Snow Lidar Datasets

Abstract Cloud microphysical processes are an important facet of atmospheric modeling, as they can control the initiation and rates of snowfall. Thus, parameterizations of these processes have important implications for modeling seasonal snow accumulation. We conduct experiments with the Weather Research and Forecasting (WRF V4.3.3) Model using three different microphysics parameterizations, including a sophisticated new scheme (ISHMAEL). Simulations are conducted for two cold seasons (2018 and 2019) centered on the Colorado Rockies’ ∼750-km 2 East River watershed. Precipitation efficiencies are quantified using a drying-ratio mass budget approach and point evaluations are performed against three NRCS SNOTEL stations. Precipitation and meteorological outputs from each are used to force a land surface model (Noah-MP) so that peak snow accumulation can be compared against airborne snow lidar products. We find that microphysical parameterization choice alone has a modest impact on total precipitation on the order of ±3% watershed-wide, and as high as 15% for certain regions, similar to other studies comparing the same parameterizations. Precipitation biases evaluated against SNOTEL are 15% ± 13%. WRF Noah-MP configurations produced snow water equivalents with good correlations with airborne lidar products at a 1-km spatial resolution: Pearson’s r values of 0.9, RMSEs between 8 and 17 cm, and percent biases of 3%–15%. Noah-MP with precipitation from the PRISM geostatistical precipitation product leads to a peak SWE underestimation of 32% in both years examined, and a weaker spatial correlation than the WRF configurations. We fall short of identifying a clearly superior microphysical parameterization but conclude that snow lidar is a valuable nontraditional indicator of model performance.

54 ENVIRONMENTAL SCIENCES↗

Effects of Cloud Liquid-Phase Microphysical Processes in Mixed-Phase Cumuli Over the Tibetan Plateau

Numerical simulations often overpredict precipitation over the Tibetan Plateau (TP). To examine the factors causing precipitation overprediction, different parameterizations of liquid-phase microphysical processes (accretion, autoconversion, and entrainment-mixing) are implemented into the Morrison microphysics scheme to simulate a TP precipitation event in summer with the Weather Research and Forecasting (WRF) model. The general spatial distribution and temporal trend of precipitation are captured by all simulations, but the precipitation rate is overpredicted. The results from sensitivity experiments suggest that compared to other examined liquid-phase processes, the accretion process is more important in precipitation simulation over the TP region. Further investigation with the Heidke skill scores reveals that accretion parameterization that takes into account the raindrop size produces the most accurate results in terms of the total surface precipitation. This parameterization suppresses spurious accretion and does not produce liquid-phase precipitation until cloud droplets are big enough. Here, it is also confirmed that increasing the model resolution can reduce precipitation overprediction. Results from the case study are confirmed by the use of a one-month simulation.

54 ENVIRONMENTAL SCIENCES↗

Medically relevant ElectroNeedle technology development.

ElectroNeedles technology was developed as part of an earlier Grand Challenge effort on Bio-Micro Fuel Cell project. During this earlier work, the fabrication of the ElectroNeedles was accomplished along with proof-of-concept work on several electrochemically active analytes such as glucose, quinone and ferricyanide. Additionally, earlier work demonstrated technology potential in the field of immunosensors by specifically detecting Troponin, a cardiac biomarker. The current work focused upon fabrication process reproducibility of the ElectroNeedles and then using the devices to sensitively detect p-cresol, a biomarker for kidney failure or nephrotoxicity. Valuable lessons were learned regarding fabrication assurance and quality. The detection of p-cresol was accomplished by electrochemistry as well as using fluorescence to benchmark ElectroNeedles performance. Results from these studies will serve as a guide for the future fabrication processes involving ElectroNeedles as well as provide the groundwork necessary to expand technology applications. One paper has been accepted for publication acknowledging LDRD funding (K. E. Achyuthan et al, Comb. Chem. & HTS, 2008). We are exploring the scope for a second paper describing the applications potential of this technology.

30 DIRECT ENERGY CONVERSION↗

(U) Average Scattering Angle Cosine Sensitivities

The Evaluated Nuclear Data File (ENDF) provides covariances of the average scattering angle cosine $\overline{μ}$ for 117 nuclides, and the NJOY nuclear data processing code can process these covariances. To propagate them to the uncertainty of a response due to uncertainties in $\overline{μ}$ requires sensitivities of the response with respect to $\overline{μ}$. This report uses NJOY’s definition of $\overline{μ}$ and derives a relationship between the sensitivity of a response to $\overline{μ}$ and the sensitivity of the response to the anisotropic P 1 elastic scattering cross section. This relationship has been implemented in the multigroup neutron sensitivity code SENSMG, which relies on the discrete ordinates code PARTISN for the neutron transport calculations. Kodeli has also calculated sensitivities with respect to $\overline{μ}$ and associated uncertainties. However, the formal derivation of this paper shows that the definition of the sensitivity with respect to $\overline{μ}$ is ambiguous because there are multiple ways to change $\overline{μ}$ by changing scattering cross sections. Here we derive two such ways. Both are implemented in SENSMG. This report is organized as follows. Section II discusses $\overline{μ}$ and its significance. Section III presents the equations used for the sensitivity of a response with respect to $\overline{μ}$, and Section IV discusses how to compute these sensitivities with SENSMG and MCNP6.3. Section V is a fast-spectrum test problem, and Sec. VI is a thermal-spectrum problem. Section VII is a summary. The example problem inputs are listed in the appendix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-sensitivity high-throughput chip based biosensor array for multiplexed detection of heavy metals

Heavy metal ions released into the environment from industrial processes lead to various health hazards. We propose an on-chip label-free detection approach that allows high-sensitivity and high-throughput detection of heavy metals. The sensing device consists of 2-dimensional photonic crystal microcavities that are combined by multimode interferometer to form a sensor array. Here, we experimentally demonstrate the detection of cadmium-chelate conjugate with concentration as low as 5 parts-per-billion (ppb).

42 ENGINEERING↗

High-Temperature Fe-Based Fischer–Tropsch Synthesis: Experimentally Validated Kinetic Models Implemented at Pellet and Reactor Scales

Pellet- and reactor-scale models for Fischer–Tropsch synthesis (FTS) with a Fe–K/silica catalyst were developed to investigate the sensitivity of the hydrocarbon products and carbon dioxide selectivity to process conditions and feed composition at high temperature (350–400 °C), moderate pressure (1–10 bar), and a range of H 2 /CO ratios (3–1). The major objective of this paper is to develop, validate, and evaluate a high-temperature FTS model that is then used to assess the feasibility of process integration with syngas production. Since there is limited kinetic data available, in literature at these conditions, bench-scale reactor tests were conducted to obtain operational data for parameter fitting of kinetic expressions used in the model. This resulting kinetic model demonstrated agreement with the experimental data with an R 2 of 0.97 to the testing data set and, thus, was feasible to apply at pellet and reactor scales. Here, multiple pellet sizes were modeled to detail the role of transport limitations as the sphere’s diameter approached and exceeded 1 mm. Application of the reactor model indicated that hydrocarbon selectivity depended strongly on temperature, whereas the ratio of olefin to paraffin products decreased with increasing temperature, pressure, and H 2 /CO ratio. Product selectivity was not sensitive to the conversion of carbon monoxide. Furthermore, the roles of the pressure and H 2 /CO ratio were closely coupled. At a H 2 /CO ratio of 3, only slight variations in selectivity occurred over a pressure range of 1–20 bar, whereas at a ratio of 1, selectivity could vary by as much as 30% over the same pressure range. At pressures below 5 bar and temperatures above 350 °C, minimal selectivity to heavy hydrocarbons (C 12+ ) is obtained, and selectivity to midrange products (C 5–11 ) rapidly declined as pressure dropped below 5 bar, which indicated that an operational pressure of at least 5 bar is needed to achieve reasonable yields in this temperature range. These results, while tentative, provide guidelines for further experimentation and evaluation of integrated FTS processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of Sample Geometry and Loading Rate onTensile Ductility of TRIP800 Steel

The effects of sample geometry and loading rate on the tensile ductility of a commercial grade Transformation Induced Plasticity (TRIP) steel are examined in this paper. Quasistatic tensile tests were performed for the 1.2mm gauge TRIP800 steel sheets with two geometries: sub-sized ASTM E-8 and a custom designed miniature tensile sample. Sample geometry effects on post-uniform elongation are discussed together with other experimental data reported in the open literature. Further discussions on the effects of sample geometry are cast in the context of mesh-size dependent ductility in finite element-based engineering simulations. The quasi-static tensile curve for the miniature sample is then compared with the split Hopkinson bar results at the loading rates of 1700-S-1 and 2650-S-1 with the same sample design. In contrary to the typical strain rate sensitivity results for mild steel where the dynamic strength increase at high strain rate usually occurs at the price of ductility reduction, our results show that the TRIP800 under examination has positive strain rate sensitivity on both strength and ductility. Images of the deformation process captured by high speed camera together with scanning electron microscopy (SEM) near the fracture zone are also used to elucidate the different deformation modes at different loading rates.

36 MATERIALS SCIENCE↗

Optimised Post-Exposure Image Sharpening Code for L3-CCD Detectors

As light from celestial bodies traverses Earth's atmosphere, the wavefronts are distorted by atmospheric turbulence, thereby lowering the angular resolution of ground-based imaging. Rapid time-series imaging enables Post-Exposure Image Sharpening (PEIS) techniques, which employ shift-and-add frame registration to remove the tip-tilt component of the wavefront error--as well as telescope wobble, thus benefiting all observations. Further resolution gains are possible by selecting only frames with the best instantaneous seeing--a technique sometimes calling 'Lucky Imaging'. We implemented these techniques in the 1990s, with the TRIFFID imaging photon-counting camera, and its associated data reduction software. The software was originally written for time-tagged photon-list data formats, recorded by detectors such as the MAMA. This paper describes our deep re-structuring of the software to handle the 2-d FITS images produced by Low Light Level CCD (L3-CCD) cameras, which have sufficient time-series resolution (>30 Hz) for PEIS. As before, our code can perform straight frame co-addition, use composite reference stars, perform PEIS under several different algorithms to determine the tip/tilt shifts, store 'quality' and shift information for each frame, perform frame selection, and generate exposure-maps for photometric correction. In addition, new code modules apply all 'static' calibrations (bias subtraction, dark subtraction and flat-fielding) to the frames immediately prior to the other algorithms. A unique feature of our PEIS/Lucky Imaging code is the use of bidirectional wiener-filtering. Coupled with the far higher sensitivity of the L3-CCD over the previous TRIFFID detectors, much fainter reference stars and much narrower time windows can be used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-201-03: Coded Aperture Gamma-Ray Imaging Using Pixelated Semiconductor Detectors

Purpose: Improved localization of gamma-ray emissions from radiotracers is essential to the progress of nuclear medicine. Polaris is a portable, room-temperature operated gamma-ray imaging spectrometer composed of two 3×3 arrays of thick CdZnTe (CZT) detectors, which detect gammas between 30keV and 3MeV with energy resolution of <1% FWHM at 662keV. Compton imaging is used to map out source distributions in 4-pi space; however, is only effective above 300keV where Compton scatter is dominant. This work extends imaging to photoelectric energies (<300keV) using coded aperture imaging (CAI), which is essential for localization of Tc-99m (140keV). Methods: CAI, similar to the pinhole camera, relies on an attenuating mask, with open/closed elements, placed between the source and position-sensitive detectors. Partial attenuation of the source results in a “shadow” or count distribution that closely matches a portion of the mask pattern. Ideally, each source direction corresponds to a unique count distribution. Using backprojection reconstruction, the source direction is determined within the field of view. The knowledge of 3D position of interaction results in improved image quality. Results: Using a single array of detectors, a coded aperture mask, and multiple Co-57 (122keV) point sources, image reconstruction is performed in real-time, on an event-by-event basis, resulting in images with an angular resolution of ∼6 degrees. Although material nonuniformities contribute to image degradation, the superposition of images from individual detectors results in improved SNR. CAI was integrated with Compton imaging for a seamless transition between energy regimes. Conclusion: For the first time, CAI has been applied to thick, 3D position sensitive CZT detectors. Real-time, combined CAI and Compton imaging is performed using two 3×3 detector arrays, resulting in a source distribution in space. This system has been commercialized by H3D, Inc. and is being acquired for various applications worldwide, including proton therapy imaging R&D.

60 APPLIED LIFE SCIENCES↗