Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Dose-Escalation Study of Single-Fraction Stereotactic Body Radiotherapy for Liver Malignancies

Purpose: We performed a Phase I dose-escalation study to explore the feasibility and safety of treating primary and metastatic liver tumors with single-fraction stereotactic body radiotherapy (SBRT). Methods and Materials: Between February 2004 and February 2008, 26 patients were treated for 40 identifiable lesions. Nineteen patients had hepatic metastases, 5 had intrahepatic cholangiocarcinomas, and 2 had recurrent hepatocellular carcinomas. The prescribed radiation dose was escalated from 18 to 30 Gy at 4-Gy increments with a planned maximum dose of 30 Gy. Cumulative incidence functions accounted for competing risks to estimate local failure (LF) incidence over time under the competing risk of death. Results: All patients tolerated the single-fraction SBRT well without developing a dose-limiting toxicity. Nine acute Grade 1 toxicities, one acute Grade 2 toxicity, and two late Grade 2 gastrointestinal toxicities were observed. After a median of 17 months follow-up (range, 2-55 months), the cumulative risk of LF at 12 months was 23%. Fifteen patients have died: 11 treated for liver metastases and 4 with primary liver tumors died. The median survival was 28.6 months, and the 2-year actuarial overall survival was 50.4%. Conclusions: It is feasible and safe to deliver single-fraction, high-dose SBRT to primary or metastatic liver malignancies measuring {<=}5 cm. Moreover, single-fraction SBRT for liver lesions demonstrated promising local tumor control with minimal acute and long-term toxicity. Single-fraction SBRT appears to be a viable nonsurgical option, but further studies are warranted to evaluate both control rates and impact on quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-R-48: Early Prediction of Pathological Response of Locally Advanced Rectal Cancer Using Perfusion CT:A Prospective Clinical Study

Purpose: To prospectively evaluate the tumor vascularity assessed by perfusion CT for prediction of chemo-radiation treatment (CRT) response in locally advanced rectal cancer (LARC). Methods: Eighteen consecutive patients (61.9±8.8 years, from March–June 2015) diagnosed with LARC who underwent 6–8 weeks CRT followed by surgery were included. The pre-treatment perfusion CT was acquired after a 5s delay of contrast agent injection for 45s with 1s interval. A total of 7-cm craniocaudal range covered the tumor region with 3-mm slice thickness. The effective radiation dose is around 15mSv, which is about 1.5 the conventional abdomen/pelvis CT dose. The parametric map of blood flow (BF), blood volume (BV), mean transit time (MTT), permeability (PMB), and maximum intensity map (MIP) were obtained from commercial software (Syngo-CT 2011A, Siemens). An experienced radiation oncologist outlined the tumor based on the pre-operative MR and pathologic residual region, but was blinded with regards to pathological tumor stage. The perfusion parameters were compared to histopathological response quantified by tumor regression grade as good-responder (GR, TRG 0-1) vs. non-good responder (non-GR). Furthermore, the predictive value for pathological complete response (pCR) was also investigated. Results: Both BV (p=0.02) and MTT (P=0.02) was significantly higher and permeambility was lower (p=0.004) in the good responders. The BF was higher in GR group but not statistically significant. Regarding the discrimination of pCR vs non-pCR, the BF was higher in the pCR group (p=0.08) but none of those parameters showed statistically significant differences. Conclusion: BV and MTT can discriminate patients with a favorable response from those that fail to respond well, potentially selecting high-risk patients with resistant tumors that may benefit from an aggressive preoperative treatment approach. However, future studies with more patient data are needed to verify the prognostic value of perfusion CT especially for pCR prediction. This work is supported by the National High-tech R&D program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917), Natural Science Foundation of China (NSFC Grant No. 81201091).

60 APPLIED LIFE SCIENCES↗

SU-F-T-649: Dosimetric Evaluation of Non-Coplanar Arc Therapy Using a Novel Rotating Gamma Ray System

Purpose: Stereotactic intra and extra-cranial body radiation therapy has evolved with advances in treatment accuracy, effective radiation dose, and parameters necessary to maximize machine capabilities. Novel gamma systems with a ring type gantry were developed having the ability to perform oblique arcs. The aim of this study is to explore the dosimetric advantages of this new system. Methods: The rotating Gamma system is named CybeRay (Cyber Medical Corp., Xian, China). It has a treatment head of 16 cobalt-60 sources focused to the isocenter, which can rotate 360° on the ring gantry and swing 35° in the superior direction. Treatment plans were generated utilizing our in-house Monte Carlo treatment planning system. A cylindrical phantom was modeled with 2mm voxel size. Dose inside the cylindrical phantom was calculated for coplanar and non-coplanar arcs. Dosimetric differences between CybeRay cobalt beams and CyberKnife 6MV beams were compared in a lung phantom and for previously treated SBRT patients. Results: The full width at half maxima of cross profiles in the S-I direction for the coplanar setup matched the cone sizes, while for the non-coplanar setup, FWHM was larger by 2mm for a 10mm cone and about 5mm for larger cones. In the coronal and sagittal view, coplanar beams showed elliptical shaped isodose lines, while non-coplanar beams showed circular isodose lines. Thus proper selection of the oblique angle and cone size can aid optimal dose matching to the target volume. Comparing a single 5mm cone from CybeRay to that from CyberKnife showed similar penumbra in a lung phantom but CybeRay had significant lower doses beyond lung tissues. Comparable treatment plans were obtained with CybeRay as that from CyberKnife.ConclusionThe noncoplanar multiple source arrangement of CybeRay will be of great clinical benefits for stereotactic intra and extra-cranial radiation therapy.

60 APPLIED LIFE SCIENCES↗

Effective Dose Reduction to Cardiac Structures Using Protons Compared With 3DCRT and IMRT in Mediastinal Hodgkin Lymphoma

Purpose: We investigated the dosimetric impact of proton therapy (PT) on various cardiac subunits in patients with Hodgkin lymphoma (HL). Methods and Materials: From June 2009 through December 2010, 13 patients were enrolled on an institutional review board-approved protocol for consolidative involved-node radiotherapy (INRT) for HL. Three separate treatment plans were developed prospectively by using three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and PT. Cardiac subunits were retrospectively contoured on the 11 patients with intravenous-contrast simulation scans, and the doses were calculated for all treatment plans. A Wilcoxon paired test was performed to evaluate the statistical significance (p < 0.05) of 3DCRT and IMRT compared with PT. Results: The mean heart doses were 21 Gy, 12 Gy, and 8 Gy (relative biologic effectiveness [RBE]) with 3DCRT, IMRT, and PT, respectively. Compared with 3DCRT and IMRT, PT reduced the mean doses to the left and right atria; the left and right ventricles; the aortic, mitral, and tricuspid valves; and the left anterior descending, left circumflex, and right circumflex coronary arteries. Conclusions: Compared with 3DCRT and IMRT, PT reduced the radiation doses to all major cardiac subunits. Limiting the doses to these structures should translate into lower rates of cardiac toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bilateral Arterial Embolization of the Prostate Through a Single Prostatic Artery: A Case Series

Peri-prostatic shunts are frequent during PAE, carrying the risk of non-target embolization of penis/corpus cavernosum or rectum but also the potential advantage to irrigate the contralateral lobe. Sometimes, bilateral embolization is impossible, carrying the risk of limited clinical success. The possibility to reach contralateral prostatic territory from the ipsilateral prostatic artery (PA) and embolize it via peri/intra-prostatic anastomoses could be of interest in this situation. We describe a series of three consecutive patients (among 89 consecutive patients treated by PAE for symptomatic BPH) who underwent successful embolization of both prostatic lobes through catheterization of a PA on only one side. All patients had clinical success after a mean follow-up of 3.3 months. Dosimetry of these three procedures indicates that there may be radiation dose savings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Residual Setup Errors Towards the Heart After Image Guidance Linked With Poorer Survival in Lung Cancer Patients: Do We Need Stricter IGRT Protocols?

Image guided radiation therapy (IGRT) is widely used, but data directly relating set-up errors to patient outcome are scarce. This study investigates the relationship between residual IGRT shifts and overall patient survival and uses the observed relations to identify structures sensitive to radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging of cardiac perfusion of free-breathing small animals using dynamic phase-correlated micro-CT

Purpose:Mouse models of cardiac diseases have proven to be a valuable tool in preclinical research. The high cardiac and respiratory rates of free breathing mice prohibit conventional in vivo cardiac perfusion studies using computed tomography even if gating methods are applied. This makes a sacrification of the animals unavoidable and only allows for the application of ex vivo methods. Methods: To overcome this issue the authors propose a low dose scan protocol and an associated reconstruction algorithm that allows for in vivo imaging of cardiac perfusion and associated processes that are retrospectively synchronized to the respiratory and cardiac motion of the animal. The scan protocol consists of repetitive injections of contrast media within several consecutive scans while the ECG, respiratory motion, and timestamp of contrast injection are recorded and synchronized to the acquired projections. The iterative reconstruction algorithm employs a six-dimensional edge-preserving filter to provide low-noise, motion artifact-free images of the animal examined using the authors' low dose scan protocol. Results: The reconstructions obtained show that the complete temporal bolus evolution can be visualized and quantified in any desired combination of cardiac and respiratory phase including reperfusion phases. The proposed reconstruction method thereby keeps the administered radiation dose at a minimum and thus reduces metabolic inference to the animal allowing for longitudinal studies. Conclusions: The authors' low dose scan protocol and phase-correlated dynamic reconstruction algorithm allow for an easy and effective way to visualize phase-correlated perfusion processes in routine laboratory studies using free-breathing mice.

60 APPLIED LIFE SCIENCES↗

Effective Dose and Effective Risk from Post–Single Photon Emission Computed Tomography Imaging of the Lumbar Spine

Planar bone scans play an important role in the staging and monitoring of malignancy and metastases. Metastases in the lumbar spine are associated with significant morbidity; therefore, accurate diagnosis is essential. Supplementary imaging after planar bone scans is often required to characterize lesions; however, this is associated with additional radiation dose. This article provides information on the comparative effective dose and effective risk from supplementary lumbar spine radiographs, low-dose computed tomography (LDCT), and diagnostic CT (DCT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In vivo assessment of magnesium status in human body using accelerator-based neutron activation measurement of hands: A pilot study

Magnesium (Mg) is an element essential for many enzymatic reactions in the human body. Various human and animal studies suggest that changes in Mg status are linked to diseases such as cardiac arrhythmia, coronary heart disease, hypertension, premenstrual syndrome, and diabetes mellitus. Thus, knowledge of Mg levels in the human body is needed. A direct measurement of human blood serum, which contains only 0.3% of the total body Mg, is generally used to infer information about the status of Mg in the body. However, in many clinical situations, Mg stored in large levels, for example in bones, muscles, and soft tissues, needs to be monitored either to evaluate the efficacy of a treatment or to study the progression of diseases associated with the deficiency of total body Mg. This work presents a feasibility study of a noninvasive, in vivo neutron activation analysis (IVNAA) technique using the {sup 26}Mg(n,{gamma}){sup 27}Mg reaction to measure Mg levels in human hands. The technique employs the McMaster University high beam current Tandetron accelerator hand irradiation facility and an array of eight NaI (T1) detectors arranged in a 4{pi} geometry for delayed counting of the 0.844 and 1.014 MeV gamma rays emitted when {sup 27}Mg decays in the irradiated hand. Mg determination in humans using IVNAA of hands has been demonstrated to be feasible, with effective doses as low as one-quarter of those delivered in chest x rays. The overall experimental uncertainty in the measurements is estimated to be approximately 5% (1{sigma}). The results are found to be in the range of the in vitro measurements reported for other cortical bones collected from different sites of the human skeleton, which confirms that this technique mainly provides a measure of the amount of Mg in hand bones. The average concentration of Mg determined in human hands is 10.96{+-}1.25 ({+-}1 SD) mg Mg/g Ca. The coefficient of variation (11%) observed in this study is comparable with or lower than several studies using in vitro measurements reported in the literature and therefore allows for a quantitative intersubject comparison, even if to a limited extent. The features of the developed technique such as its simplicity, rapidity, accuracy, robustness, noninvasive nature, and very effective use of radiation doses, present the technique as a viable diagnostic tool available for trial in a clinical environment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pediatric organ dose measurements in axial and helical multislice CT

An anthropomorphic pediatric phantom (5-yr-old equivalent) was used to determine organ doses at specific surface and internal locations resulting from computed tomography (CT) scans. This phantom contains four different tissue-equivalent materials: Soft tissue, bone, brain, and lung. It was imaged on a 64-channel CT scanner with three head protocols (one contiguous axial scan and two helical scans [pitch=0.516 and 0.984]) and four chest protocols (one contiguous axial scan and three helical scans [pitch=0.516, 0.984, and 1.375]). Effective mA s [=(tube currentxrotation time)/pitch] was kept nearly constant at 200 effective mA s for head and 290 effective mA s for chest protocols. Dose measurements were acquired using thermoluminescent dosimeter powder in capsules placed at locations internal to the phantom and on the phantom surface. The organs of interest were the brain, both eyes, thyroid, sternum, both breasts, and both lungs. The organ dose measurements from helical scans were lower than for contiguous axial scans by 0% to 25% even after adjusting for equivalent effective mA s. There was no significant difference (p>0.05) in organ dose values between the 0.516 and 0.984 pitch values for both head and chest scans. The chest organ dose measurements obtained at a pitch of 1.375 were significantly higher than the dose values obtained at the other helical pitches used for chest scans (p<0.05). This difference was attributed to the automatic selection of the large focal spot due to a higher tube current value. These findings suggest that there may be a previously unsuspected radiation dose benefit associated with the use of helical scan mode during computed tomography scanning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Low-Dose Hyperradiosensitivity: Is There a Place for Future Investigation in Clinical Settings?

Background and Purpose: In vitro radiation doses of below 0.5 Gy have been shown to be more effective than higher doses per unit dose in killing clonogenic cells of many epithelial tumor cell lines. This phenomenon is known as low-dose hyperradiosensitivity. Preclinical studies have now suggested that there is synergism between chemotherapy and low-dose fractionated radiotherapy (LD-FRT). To test the clinical efficacy of this approach, we prospectively evaluated concurrent palliative chemotherapy and LD-FRT in patients with various types of epithelial tumors. Methods and Materials: Patients suffering from relapses or metastases of epithelial tumors were scheduled to receive concurrent LD-FRT (two fractions of 0.4 Gy per day) and chemotherapy. Radiologic assessments were performed after three cycles of chemotherapy plus LD-FRT. Results: Between June 2006 and October 2007, 12 patients with lung cancer, 7 patients with head-and-neck tumors, 2 patients with breast cancer, and 1 patient with esophageal carcinoma, for a total patient population of 22, underwent concomitant LD-FRT and chemotherapy. All patients but 3 (86%) had received previous treatments for their cancer. The median total dose of LD-FRT delivered was 800 cGy (range, 320-1280 cGy). The overall response rate was 45% (42% in previously treated patients). Grade 3-4 hematologic toxicities (Radiation Therapy Oncology Group ratings) were observed in 2 patients. At a median follow-up of 6.5 months, however, no local toxicity was observed. Conclusion: In our experience, concurrent LD-FRT and chemotherapy was well tolerated. Because the response rate seems promising, prospective Phase II studies of the strategy are now under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spot Scanning Proton Therapy for Malignancies of the Base of Skull: Treatment Planning, Acute Toxicities, and Preliminary Clinical Outcomes

Purpose: To describe treatment planning techniques and early clinical outcomes in patients treated with spot scanning proton therapy for chordoma or chondrosarcoma of the skull base. Methods and Materials: From June 2010 through August 2011, 15 patients were treated with spot scanning proton therapy for chordoma (n=10) or chondrosarcoma (n=5) at a single institution. Toxicity was prospectively evaluated and scored weekly and at all follow-up visits according to Common Terminology Criteria for Adverse Events, version 3.0. Treatment planning techniques and dosimetric data were recorded and compared with those of passive scattering plans created with clinically applicable dose constraints. Results: Ten patients were treated with single-field-optimized scanning beam plans and 5 with multifield-optimized intensity modulated proton therapy. All but 2 patients received a simultaneous integrated boost as well. The mean prescribed radiation doses were 69.8 Gy (relative biological effectiveness [RBE]; range, 68-70 Gy [RBE]) for chordoma and 68.4 Gy (RBE) (range, 66-70) for chondrosarcoma. In comparison with passive scattering plans, spot scanning plans demonstrated improved high-dose conformality and sparing of temporal lobes and brainstem. Clinically, the most common acute toxicities included fatigue (grade 2 for 2 patients, grade 1 for 8 patients) and nausea (grade 2 for 2 patients, grade 1 for 6 patients). No toxicities of grades 3 to 5 were recorded. At a median follow-up time of 27 months (range, 13-42 months), 1 patient had experienced local recurrence and a second developed distant metastatic disease. Two patients had magnetic resonance imaging-documented temporal lobe changes, and a third patient developed facial numbness. No other subacute or late effects were recorded. Conclusions: In comparison to passive scattering, treatment plans for spot scanning proton therapy displayed improved high-dose conformality. Clinically, the treatment was well tolerated, and with short-term follow-up, disease control rates and toxicity profiles were favorable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Capstone Depleted Uranium Aerosol Biokinetics, Concentrations, and Doses

One of the principal goals of the Capstone Depleted Uranium (DU) Aerosol Study was to quantify and characterize DU aerosols generated inside armored vehicles by perforation with a DU penetrator. This study consequently produced a database in which the DU aerosol source terms were specified both physically and chemically for a variety of penetrator-impact geometries and conditions. These source terms were used to calculate radiation doses and uranium concentrations for various scenarios as part of the Capstone DU Human Health Risk Assessment (HHRA). This paper describes the scenario-related biokinetics of uranium, and summarizes intakes, chemical concentrations to the organs, and E(50) and HT(50) for organs and tissues based on exposure scenarios for personnel in vehicles at the time of perforation as well as for first responders. For a given exposure scenario (duration time and breathing rates), the range of DU intakes among the target vehicles and shots was not large, about a factor of 10, with the lowest being from a ventilated operational Abrams tank and the highest being for an unventilated Abrams with DU penetrator perforating DU armor. The ranges of committed effective doses were more scenario-dependent than were intakes. For example, the largest range, a factor of 20, was shown for scenario A, a 1-min exposure, whereas, the range was only a factor of two for the first-responder scenario (E). In general, the committed effective doses were found to be in the tens of mSv. The risks ascribed to these doses are discussed separately.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiscale deformable registration for dual-energy x-ray imaging

Dual-energy (DE) imaging of the chest improves the conspicuity of subtle lung nodules through the removal of overlying anatomical noise. Recent work has shown double-shot DE imaging (i.e., successive acquisition of low- and high-energy projections) to provide detective quantum efficiency, spectral separation (and therefore contrast), and radiation dose superior to single-shot DE imaging configurations (e.g., with a CR cassette). However, the temporal separation between high-energy (HE) and low-energy (LE) image acquisition can result in motion artifacts in the DE images, reducing image quality and diminishing diagnostic performance. This has motivated the development of a deformable registration technique that aligns the HE image onto the LE image before DE decomposition. The algorithm reported here operates in multiple passes at progressively smaller scales and increasing resolution. The first pass addresses large-scale motion by means of mutual information optimization, while successive passes (2-4) correct misregistration at finer scales by means of normalized cross correlation. Evaluation of registration performance in 129 patients imaged using an experimental DE imaging prototype demonstrated a statistically significant improvement in image alignment. Specific to the cardiac region, the registration algorithm was found to outperform a simple cardiac-gating system designed to trigger both HE and LE exposures during diastole. Modulation transfer function (MTF) analysis reveals additional advantages in DE image quality in terms of noise reduction and edge enhancement. This algorithm could offer an important tool in enhancing DE image quality and potentially improving diagnostic performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Problems with Estimating Annual Mean Indoor Radon Concentrations

Radon and its progeny in dwellings is responsible for the majority of the total radiation dose among the general population. The indoor radon concentration varies considerably during the daytime, individual days, seasons and even years. It is affected by many factors such as ventilation, soil concentration, quality of house insulation and others.The annual mean value of the radon concentration in buildings is important in order to estimate the effective dose to inhabitants. However, it is not always possible to perform radon measurements over a period of one year. Thus estimates based on short-term continuous measurements are suggested.We analyse hourly radon measurements obtained from one uninhabited rural house in Teleci in the Czech Republic. We study the behaviour of the radon concentration with time and its relationship to meteorological variables such as outdoor temperature, wind speed or pressure. Further we discuss various estimates of the annual mean radon concentration and their properties.

54 ENVIRONMENTAL SCIENCES↗

TU-D-209-04: How Useful Are Indirect Dose Metrics for Estimating Peak Skin Dose in Interventional Cardiology?

Purpose: The purpose of this study was to determine if a relationship between indirect dose metrics and PSD could be established for fluoroscopically-guided interventional cardiology procedures. Methods: PSD were measured directly using XR-RV3 radiochromic film for 94 consecutive fluoroscopically guided interventional cardiology procedures performed at two sites. Procedures were both diagnostic and therapeutic in nature. Radiation dose structured reports (RDSR) were collected for each procedure and used to calculate indirect estimates of PSD which were compared to the measured PSD. Reference air kerma (Ka,r) was also compared to the measured PSD. Pearson’s correlation coefficient was calculated for each metric and metrics were compared to measured PSD using a two-tailed t-test. Data were log transformed prior to statistical analysis. Results: Both Ka,r and the calculated PSD were closely correlated with measured PSD at each sites (Ka,r: 0.92 and 0.86, indirect PSD: 0.91 and 0.88). At one site, neither Ka,r nor indirect PSD was significantly different from the measured PSD (p = 0.22 and p=0.054, respectively), while at the second site both Ka,r and indirect PSD were significantly higher than measured PSD (p<0.0001 and p<0.0001, respectively). In almost all cases, both Ka,r and indirect PSD overestimated the true PSD. Conclusions: The use of a range of gantry angles and table positions, along with variation in procedural imaging requirements, limits the utility of indirect dose metrics for predicting PSD for interventional cardiology procedures. A. Kyle Jones and Alexander S. Pasciak are owners of Fluoroscopic Safety, LLC.

60 APPLIED LIFE SCIENCES↗

SU-E-J-87: Ventilation Weighting Effect On Mean Doses of Both Side Lungs for Patients with Advanced Stage Lung Cancer

Purpose: To study ventilation weighting effect on radiation doses to both side lungs for patients with advanced stage lung cancer. Methods: Fourteen patients with advanced stage lung cancer were included in this retrospective study. Proprietary software was developed to calculate the lung ventilation map based on 4DCT images acquired for radiation therapy. Two phases of inhale (0%) and exhale (50%) were used for the lung ventilation calculations. For each patient, the CT images were resampled to the same dose calculation resolution of 3mmx3mmx3mm. The ventilation distribution was then normalized by the mean value of the ventilation. The ventilation weighted dose was calculated by applying linearly weighted ventilation to the dose of each pixel. The lung contours were automatically delineated from patient CT image with lung window, excluding the tumor and high density tissues. For contralateral and ipsilateral lungs, the mean lung doses from the original plan and ventilation weighted mean lung doses were compared using two tail t-Test. Results: The average of mean dose was 6.1 ±3.8Gy for the contralateral lungs, and 26.2 ± 14.0Gy for the ipsilateral lungs. The average of ventilation weighted dose was 6.3± 3.8Gy for the contralateral lungs and 24.6 ± 13.1Gy for the ipsilateral lungs. The statistics analysis shows the significance of the mean dose increase (p<0.015) for the contralateral lungs and decrease (p<0.005) for the ipsilateral lungs. Conclusion: Ventilation weighted doses were greater than the un-weighted doses for contralateral lungs and smaller for ipsilateral lungs. This Result may be helpful to understand the radiation dosimetric effect on the lung function and provide planning guidance for patients with advance stage lung cancer.

60 APPLIED LIFE SCIENCES↗

Semiconductor Nanoparticles as Energy Mediators for Photosensitizer-Enhanced Radiotherapy

Purpose: It has been proposed that quantum dots (QDs) can be used to excite conjugated photosensitizers and produce cytotoxic singlet oxygen. To study the potential of using such a conjugate synergistically with radiotherapy to enhance cell killing, we investigated the energy transfer from megavoltage (MV) X-rays to a photosensitizer using QDs as the mediator and quantitated the enhancement in cell killing. Methods and Materials: The photon emission efficiency of QDs on excitation by 6-MV X-rays was measured using dose rates of 100-600 cGy/min. A QD-Photofrin conjugate was synthesized by formation of an amide bond. The role of Foerster resonance energy transfer in the energy transferred to the Photofrin was determined by measuring the degree of quenching at different QD/Photofrin molar ratios. The enhancement of H460 human lung carcinoma cell killing by radiation in the presence of the conjugates was studied using a clonogenic survival assay. Results: The number of visible photons generated from QDs excited by 6-MV X-rays was linearly proportional to the radiation dose rate. The Foerster resonance energy transfer efficiency approached 100% as the number of Photofrin molecules conjugated to the QDs increased. The combination of the conjugate with radiation resulted in significantly lower H460 cell survival in clonogenic assays compared with radiation alone. Conclusion: The novel QD-Photofrin conjugate shows promise as a mediator for enhanced cell killing through a linear and highly efficient energy transfer from X-rays to Photofrin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗