Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Transmission electron microscopy of the amorphization of copper indium diselenide by in situ ion irradiation

Copper indium diselenide (CIS), along with its derivatives Cu(In,Ga)(Se,S){sub 2}, is a prime candidate for use in the absorber layers of photovoltaic devices. Due to its ability to resist radiation damage, it is particularly well suited for use in extraterrestrial and other irradiating environments. However, the nature of its radiation hardness is not well understood. In this study, transmission electron microscopy (TEM) with in situ ion irradiation was used to monitor the dynamic microstructural effects of radiation damage on CIS. Samples were bombarded with 400 keV xenon ions to create large numbers of atomic displacements within the thickness of the TEM samples and thus explore the conditions under which, if any, CIS could be amorphized. By observing the impact of heavily damaging radiation in situ--rather than merely the end-state possible in ex situ experiments--at the magnifications allowed by TEM, it was possible to gain an understanding of the atomistic processes at work and the underlying mechanism that give rise to the radiation hardness of CIS. At 200 K and below, it was found that copper-poor samples could be amorphized and copper-rich samples could not. This difference in behavior is linked to the crystallographic phases that are present at different compositions. Amorphization was found to progress via a combination of one- and two-hit processes. The radiation hardness of CIS is discussed in terms of crystallographic structures/defects and the consequences these have for the ability of the material to recover from the effects of displacing radiation.

36 MATERIALS SCIENCE↗

Unattended Monitoring of Uranium Holdup with Scintillating Fibers

This work evaluated the use of scintillating fiber (SciFi) radiation sensors as a cost-effective, unattended monitoring technique for uranium holdup accumulation in reprocessing equipment. With ruggedized packaging and an outer diameter of less than 1 cm, scintillating fibers offer deployment flexibility. Additionally, plastic scintillating fibers coupled with standard optical fibers provide an affordable option to monitor locations kilometers away from a localized control room or data acquisition (DAQ) system. These combinations of characteristics along with their relatively low manufacturing costs make scintillating fibers ideal for installation at key measurement points such as pipes, valves, and filtration systems.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Compact turbidity meter

Proposed monitor that detects back-reflected infrared radiation makes in situ turbidity measurements of lakes, streams, and other bodies of water. Monitor is compact, works well in daylight as at night, and is easily operated in rough seas.

Hirschberg, J. G.↗

Proton Beam Therapy Interference With Implanted Cardiac Pacemakers

Purpose: To investigate the effect of proton beam therapy (PBT) on implanted cardiac pacemaker function. Methods and Materials: After a phantom study confirmed the safety of PBT in patients with cardiac pacemakers, we treated 8 patients with implanted pacemakers using PBT to a total tumor dose of 33-77 gray equivalents (GyE) in dose fractions of 2.2-6.6 GyE. The combined total number of PBT sessions was 127. Although all pulse generators remained outside the treatment field, 4 patients had pacing leads in the radiation field. All patients were monitored by means of electrocardiogram during treatment, and pacemakers were routinely examined before and after PBT. Results: The phantom study showed no effect of neutron scatter on pacemaker generators. In the study, changes in heart rate occurred three times (2.4%) in 2 patients. However, these patients remained completely asymptomatic throughout the PBT course. Conclusions: PBT can result in pacemaker malfunctions that manifest as changes in pulse rate and pulse patterns. Therefore, patients with cardiac pacemakers should be monitored by means of electrocardiogram during PBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mometasone Furoate Effect on Acute Skin Toxicity in Breast Cancer Patients Receiving Radiotherapy: A Phase III Double-Blind, Randomized Trial From the North Central Cancer Treatment Group N06C4

Purpose: A two-arm, double-blind, randomized trial was performed to evaluate the effect of 0.1% mometasone furoate (MMF) on acute skin-related toxicity in patients undergoing breast or chest wall radiotherapy. Methods and Materials: Patients with ductal carcinoma in situ or invasive breast carcinoma who were undergoing external beam radiotherapy to the breast or chest wall were randomly assigned to apply 0.1% MMF or placebo cream daily. The primary study endpoint was the provider-assessed maximal grade of Common Terminology Criteria for Adverse Events, version 3.0, radiation dermatitis. The secondary endpoints included provider-assessed Common Terminology Criteria for Adverse Events Grade 3 or greater radiation dermatitis and adverse event monitoring. The patient-reported outcome measures included the Skindex-16, the Skin Toxicity Assessment Tool, a Symptom Experience Diary, and a quality-of-life self-assessment. An assessment was performed at baseline, weekly during radiotherapy, and for 2 weeks after radiotherapy. Results: A total of 176 patients were enrolled between September 21, 2007, and December 7, 2007. The provider-assessed primary endpoint showed no difference in the mean maximum grade of radiation dermatitis by treatment arm (1.2 for MMF vs. 1.3 for placebo; p = .18). Common Terminology Criteria for Adverse Events toxicity was greater in the placebo group (p = .04), primarily from pruritus. For the patient-reported outcome measures, the maximum Skindex-16 score for the MMF group showed less itching (p = .008), less irritation (p = .01), less symptom persistence or recurrence (p = .02), and less annoyance with skin problems (p = .04). The group's maximal Skin Toxicity Assessment Tool score showed less burning sensation (p = .02) and less itching (p = .002). Conclusion: Patients receiving daily MMF during radiotherapy might experience reduced acute skin toxicity compared with patients receiving placebo.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SWIFT X-RAY TELESCOPE MONITORING OF FERMI-LAT GAMMA-RAY SOURCES OF INTEREST

We describe a long-term Swift monitoring program of Fermi gamma-ray sources, particularly the 23 gamma-ray ''sources of interest''.We present a systematic analysis of the Swift X-Ray Telescope light curves and hardness ratios of these sources, and we calculate excess variability. We present data for the time interval of 2004 December 22 through 2012 August 31. We describe the analysis methods used to produce these data products, and we discuss the availability of these data in an online repository, which continues to grow from more data on these sources and from a growing list of additional sources. This database should be of use to the broad astronomical community for long-term studies of the variability of these objects and for inclusion in multiwavelength studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Second Cancers After Fractionated Radiotherapy: Stochastic Population Dynamics Effects

When ionizing radiation is used in cancer therapy it can induce second cancers in nearby organs. Mainly due to longer patient survival times, these second cancers have become of increasing concern. Estimating the risk of solid second cancers involves modeling: because of long latency times, available data is usually for older, obsolescent treatment regimens. Moreover, modeling second cancers gives unique insights into human carcinogenesis, since the therapy involves administering well characterized doses of a well studied carcinogen, followed by long-term monitoring. In addition to putative radiation initiation that produces pre-malignant cells, inactivation (i.e. cell killing), and subsequent cell repopulation by proliferation can be important at the doses relevant to second cancer situations. A recent initiation/inactivation/proliferation (IIP) model characterized quantitatively the observed occurrence of second breast and lung cancers, using a deterministic cell population dynamics approach. To analyze ifradiation-initiated pre-malignant clones become extinct before full repopulation can occur, we here give a stochastic version of this I I model. Combining Monte Carlo simulations with standard solutions for time-inhomogeneous birth-death equations, we show that repeated cycles of inactivation and repopulation, as occur during fractionated radiation therapy, can lead to distributions of pre-malignant cells per patient with variance >> mean, even when pre-malignant clones are Poisson-distributed. Thus fewer patients would be affected, but with a higher probability, than a deterministic model, tracking average pre-malignant cell numbers, would predict. Our results are applied to data on breast cancers after radiotherapy for Hodgkin disease. The stochastic IIP analysis, unlike the deterministic one, indicates: a) initiated, pre-malignant cells can have a growth advantage during repopulation, not just during the longer tumor latency period that follows; b) weekend treatment gaps during radiotherapy, apart from decreasing the probability of eradicating the primary cancer, substantially increase the risk of later second cancers.

Sachs, Rainer K.↗

Impact of the Revised 10 CFR 835 on the Neutron Dose Rates at LLNL

In June 2007, 10 CFR 835 [1] was revised to include new radiation weighting factors for neutrons, updated dosimetric models, and dose terms consistent with the newer ICRP recommendations. A significant aspect of the revised 10 CFR 835 is the adoption of the recommendations outlined in ICRP-60 [2]. The recommended new quantities demand a review of much of the basic data used in protection against exposure to sources of ionizing radiation. The International Commission on Radiation Units and Measurements has defined a number of quantities for use in personnel and area monitoring [3,4,5] including the ambient dose equivalent H*(d) to be used for area monitoring and instrument calibrations. These quantities are used in ICRP-60 and ICRP-74. This report deals only with the changes in the ambient dose equivalent and ambient dose rate equivalent for neutrons as a result of the implementation of the revised 10 CFR 835. In the report, the terms neutron dose and neutron dose rate will be used for convenience for ambient neutron dose and ambient neutron dose rate unless otherwise stated. This report provides a qualitative and quantitative estimate of how much the neutron dose rates at LLNL will change with the implementation of the revised 10 CFR 835. Neutron spectra and dose rates from selected locations at the LLNL were measured with a high resolution spectroscopic neutron dose rate system (ROSPEC) as well as with a standard neutron rem meter (a.k.a., a remball). The spectra obtained at these locations compare well with the spectra from the Radiation Calibration Laboratory's (RCL) bare californium source that is currently used to calibrate neutron dose rate instruments. The measurements obtained from the high resolution neutron spectrometer and dose meter ROSPEC and the NRD dose meter compare within the range of {+-}25%. When the new radiation weighting factors are adopted with the implementation of the revised 10 CFR 835, the measured dose rates will increase by up to 22%. The health physicists should consider this increase for any areas that have dose rates near a posting limit, such as near the 100 mrem/hr for a high radiation area, as this increase in measured dose rate may result in some changes to postings and consequent radiological controls.

61 RADIATION PROTECTION AND DOSIMETRY↗

Opportunities and challenges for structural health monitoring of radioactive waste systems and structures

Radioactive waste systems and structures (RWSS) are safety-critical facilities in need of monitoring over prolonged periods of time. Structural health monitoring (SHM) is an emerging technology that aims at monitoring the state of a structure through the use of networks of permanently mounted sensors. SHM technologies have been developed primarily within the aerospace and civil engineering communities. This paper addresses the issue of transitioning the SHM concept to the monitoring of RWSS and evaluates the opportunities and challenges associated with this process. Guided wave SHM technologies utilizing structurally-mounted piezoelectric wafer active sensors (PWAS) have a wide range of applications based on both propagating-wave and standing-wave methodologies. Hence, opportunities exist for transitioning these SHM technologies into RWSS monitoring. However, there exist certain special operational conditions specific to RWSS such as: radiation field, caustic environments, marine environments, and chemical, mechanical and thermal stressors. In order to address the high discharge of used nuclear fuel (UNF) and the limited space in the storage pools the U.S. the Department of Energy (DOE) has adopted a 'Strategy for the Management and Disposal of Used Nuclear Fuel and High-Level Radioactive Waste' (January 2013). This strategy endorses the key principles that underpin the Blue Ribbon Commission's on America's Nuclear Future recommendations to develop a sustainable program for deploying an integrated system capable of transporting, storing, and disposing of UNF and high-level radioactive waste from civilian nuclear power generation, defense, national security, and other activities. This will require research to develop monitoring, diagnosis, and prognosis tools that can aid to establish a strong technical basis for extended storage and transportation of UNF. Monitoring of such structures is critical for assuring the safety and security of the nation's spent nuclear fuel until a national policy for closure of the nuclear fuel cycle is defined and implemented. In addition, such tools can provide invaluable and timely information for verification of the predicted mechanical performance of RWSS (e.g. concrete or steel barriers) during off-normal occurrence and accident events such as the tsunami and earthquake event that affected Fukushima Daiichi nuclear power plant. The ability to verify the conditions, health, and degradation behavior of RWSS over time by applying nondestructive testing (NDT) as well as development of nondestructive evaluation (NDE) tools for new degradation processes will become challenging. The paper discusses some of the challenges associated to verification and diagnosis for RWSS and identifies SHM technologies which are more readily available for transitioning into RWSS applications. Fundamental research objectives that should be considered for the transition of SHM technologies (e.g., radiation hardened piezoelectric materials) for RWSS applications are discussed. The paper ends with summary, conclusions, and suggestions for further work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solid-State Transformation of Uranyl Peroxide Materials through High-Level Irradiation

The solid-state transformation of sodium uranyl triperoxide (Na 4 (UO 2 )(O 2 ) 3 ·9H 2 O, NaUT) to sodium uranyl tricarbonate (Na 4 (UO 2 )(CO 3 ) 3 ) by radiolysis was observed for the first time. The exposure of NaUT to 3 MGy gamma irradiation resulted in partial breakdown of the peroxides forming a mixed peroxide and carbonate species. The effects of He-ion irradiation on NaUT were also investigated up to 225 MGy using both hydrated argon and dry argon. The complete conversion to the uranyl tricarbonate phase by 56 MGy was done using hydrated argon, while dry argon did not fully convert showing the importance of water in the system. He-ion irradiated NaUT samples all convert to the tricarbonate phase with time in air post radiation exposure. This transition was monitored via Raman spectroscopy, infrared spectroscopy (IR), and powder X-ray diffraction (PXRD) to further confirm the identity of the final product as the sodium uranyl tricarbonate, čejkaite. Furthermore, this transformation outlines a mechanism for the mobility of uranyl in natural environments and in the Hanford tanks.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

V899 MON: AN OUTBURSTING PROTOSTAR WITH A PECULIAR LIGHT CURVE, AND ITS TRANSITION PHASES

We present a detailed study of V899 Mon (a new member in the FUors/EXors family of young low-mass stars undergoing outburst), based on our long-term monitoring of the source starting from 2009 November to 2015 April. Our optical and near-infrared photometric and spectroscopic monitoring recorded the source transitioning from its first outburst to a short-duration quiescence phase (<1 yr), and then returning to a second outburst. We report here the evolution of the outflows from the inner region of the disk as the accretion rate evolved in various epochs. Our high-resolution (R ∼ 37,000) optical spectrum could resolve interesting clumpy structures in the outflow traced by various lines. Change in far-infrared flux was also detected between two outburst epochs. Based on our observations, we constrained various stellar and envelope parameters of V899 Mon, as well as the kinematics of its accretion and outflow. The photometric and spectroscopic properties of this source fall between classical FUors and EXors. Our investigation of V899 Mon hints at instability associated with magnetospheric accretion being the physical cause of the sudden short-duration pause of the outburst in 2011. It is also a good candidate to explain similar short-duration pauses in outbursts of some other FUors/EXors sources.

79 ASTRONOMY AND ASTROPHYSICS↗

[Limb Scattering Data Analysis]

The primary purpose of this grant was to support analysis of the limb scattering data taken during the 1997 flight of the SOLSE (Shuttle Ozone Limb Sounding Experiment) and LORE (Limb Ozone Retrieval Experiment) instruments. Work was done to assess the performance of the retrieval algorithms for cloudy and clear sky cases in preparation for a poster presentation. The nadir-viewing data were also compared to coincident GOME (Global Ozone Monitoring Experiment) data and to radiative transfer calculations. An algorithm similar to the TOMS (Total Ozone Mapping Spectrometer) ozone retrieval algorithm was developed to infer the ozone column amount from the SOLSE nadir data. Comparison with coincident TOMS ozone column data confirmed that column ozone could be derived successfully from SOLSE nadir radiances, and also revealed significant changes in the SOLSE wavelength resolution and absolute radiometric calibration that were subsequently confirmed by comparing the post-flight instrument characterization to the pre-flight characterization, indicating a potentially useful method for monitoring instrument behavior in-flight.

Loughman, Robert↗

Solid-state transformation of uranyl peroxide materials through high-level irradiation

The solid-state transformation of sodium uranyl triperoxide (Na 4 (UO 2 )(O 2 ) 3 ∙9H 2 O, NaUT) to sodium uranyl tricarbonate (Na 4 (UO 2 )(CO 3 ) 3 ) by radiolysis has been observed for the first time. The exposure of NaUT to 3 MGy gamma irradiation resulted in partial breakdown of the peroxides forming a mixed peroxide and carbonate species. The effects of He ion irradiation on NaUT was also investigated up to 225 MGy using both hydrated argon and dry argon. The complete conversion to the uranyl tricarbonate phase by 56 MGy using hydrated argon, while dry argon did not fully convert showing the importance of water in the system. He-ion irradiated NaUT samples all convert to the tricarbonate phase with time in air post radiation exposure. This transition was monitored via Raman spectroscopy, infrared spectroscopy (IR), and powder X-ray diffraction (PXRD) to further confirm the identity of the final product as the sodium uranyl tricarbonate, čejkaite. This transformation outlines a mechanism for the mobility of uranyl in natural environments and in the Hanford tanks.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Accuracy of an infrared marker-based patient positioning system (ExacTrac®) for stereotactic body radiotherapy in localizing the planned isocenter using fiducial markers

Stereotactic Body Radiation Therapy (SBRT) requires a controlled immobilization and position monitoring of patient and target. The purpose of this work is to analyze the performance of the imaging system ExacTrac® (ETX) using infrared and fiducial markers. Materials and methods: In order to assure the accuracy of isocenter localization, a Quality Assurance procedure was applied using an infrared marker-based positioning system. Scans were acquired of an inhouse-agar gel and solid water phantom with infrared spheres. In the inner part of the phantom, three reference markers were delineated as reference and one pellet was place internally; which was assigned as the isocenter. The iPlan® RT Dose treatment planning system. Images were exported to the ETX console. Images were acquired with the ETX to check the correctness of the isocenter placement. Adjustments were made in 6D the reference markers were used to fuse the images. Couch shifts were registered. The procedure was repeated for verification purposes. Results: The data recorded of the verifications in translational and rotational movements showed averaged 3D spatial uncertainties of 0.31 ± 0.42 mm respectively 0.82° ± 0.46° in the phantom and the first correction of these uncertainties were of 1.51 ± 1.14 mm respectively and 1.37° ± 0.61°. Conclusions: This study shows a high accuracy and repeatability in positioning the selected isocenter. The ETX-system for verifying the treatment isocenter position has the ability to monitor the tracing position of interest, making it possible to be used for SBRT positioning within uncertainty ≤1mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On Comparing the Quality of Head and Neck Imrt Plans Delivered with Two Different Linear Accelerator Manufacturers

The purpose of this work was to determine whether 2 different types of linear accelerators manufacturers with similar MLC leaf widths deliver equivalent IMRT distributions for head and neck radiotherapy patients. In this study, plans delivered with Siemens linacs were re-optimized with an Elekta linac and vice versa. To test for significance, paired t-tests were computed to examine differences in target and normal tissue doses and monitor units. Dose distributions, dose-volume histograms, and dose to targets and normal tissues were found to be equivalent irrespective of the linac type. However, approximately 15% more monitor units were delivered when planned on the Elekta machine (p < 0.002). Both linear accelerators provide plans of comparable dosimetric quality; however, Elekta machines deliver slightly more monitor units than Siemens machines. This increase is likely due differences in geometric properties of the machine head designs, as modeled in the treatment planning system.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fermi/GAMMA-RAY BURST MONITOR OBSERVATIONS OF SGR J0501+4516 BURSTS

We present our temporal and spectral analyses of 29 bursts from SGR J0501+4516, detected with the gamma-ray burst monitor on board the Fermi Gamma-ray Space Telescope during 13 days of the source's activation in 2008 (August 22- September 3). We find that the T{sub 90} durations of the bursts can be fit with a log-normal distribution with a mean value of {approx}123 ms. We also estimate for the first time event durations of soft gamma repeater (SGR) bursts in photon space (i.e., using their deconvolved spectra) and find that these are very similar to the T{sub 90} values estimated in count space (following a log-normal distribution with a mean value of {approx}124 ms). We fit the time-integrated spectra for each burst and the time-resolved spectra of the five brightest bursts with several models. We find that a single power law with an exponential cutoff model fits all 29 bursts well, while 18 of the events can also be fit with two blackbody functions. We expand on the physical interpretation of these two models and we compare their parameters and discuss their evolution. We show that the time-integrated and time-resolved spectra reveal that E{sub peak} decreases with energy flux (and fluence) to a minimum of {approx}30 keV at F = 8.7 x 10{sup -6} erg cm{sup -2} s{sup -1}, increasing steadily afterward. Two more sources exhibit a similar trend: SGRs J1550-5418 and 1806-20. The isotropic luminosity, L{sub iso}, corresponding to these flux values is roughly similar for all sources (0.4-1.5 x 10{sup 40} erg s{sup -1}).

79 ASTRONOMY AND ASTROPHYSICS↗

Space Weather Nowcasting of Atmospheric Ionizing Radiation for Aviation Safety

There is a growing concern for the health and safety of commercial aircrew and passengers due to their exposure to ionizing radiation with high linear energy transfer (LET), particularly at high latitudes. The International Commission of Radiobiological Protection (ICRP), the EPA, and the FAA consider the crews of commercial aircraft as radiation workers. During solar energetic particle (SEP) events, radiation exposure can exceed annual limits, and the number of serious health effects is expected to be quite high if precautions are not taken. There is a need for a capability to monitor the real-time, global background radiations levels, from galactic cosmic rays (GCR), at commercial airline altitudes and to provide analytical input for airline operations decisions for altering flight paths and altitudes for the mitigation and reduction of radiation exposure levels during a SEP event. The Nowcast of Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS) model is new initiative to provide a global, real-time radiation dosimetry package for archiving and assessing the biologically harmful radiation exposure levels at commercial airline altitudes. The NAIRAS model brings to bear the best available suite of Sun-Earth observations and models for simulating the atmospheric ionizing radiation environment. Observations are utilized from ground (neutron monitors), from the atmosphere (the METO analysis), and from space (NASA/ACE and NOAA/GOES). Atmospheric observations provide the overhead shielding information and the ground- and space-based observations provide boundary conditions on the GCR and SEP energy flux distributions for transport and dosimetry simulations. Dose rates are calculated using the parametric AIR (Atmospheric Ionizing Radiation) model and the physics-based HZETRN (High Charge and Energy Transport) code. Empirical models of the near-Earth radiation environment (GCR/SEP energy flux distributions and geomagnetic cut-off rigidity) are benchmarked against the physics-based CMIT (Coupled Magnetosphere- Ionosphere-Thermosphere) and SEP-trajectory models.

Mertens, Christopher J.↗

Radius constraints from high-speed photometry of 20 low-mass white dwarf binaries

We carry out high-speed photometry on 20 of the shortest-period, detached white dwarf binaries known and discover systems with eclipses, ellipsoidal variations (due to tidal deformations of the visible white dwarf), and Doppler beaming. All of the binaries contain low-mass white dwarfs with orbital periods of less than four hr. Our observations identify the first eight tidally distorted white dwarfs, four of which are reported for the first time here. We use these observations to place empirical constraints on the mass-radius relationship for extremely low-mass (≤0.30 M {sub ☉}) white dwarfs. We also detect Doppler beaming in several of these binaries, which confirms their high-amplitude radial-velocity variability. All of these systems are strong sources of gravitational radiation, and long-term monitoring of those that display ellipsoidal variations can be used to detect spin-up of the tidal bulge due to orbital decay.

79 ASTRONOMY AND ASTROPHYSICS↗