Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Transport Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Simulation of solar cells with quantum wells and comparison with conventional solar cells

The efficiency of photoconversion in solar cells based on GaAs with InGaAs quantum wells under the AM 1.5 conditions for various levels of base doping has been simulated using the software package Sim-Windows. The results obtained are compared with the efficiency of photoconversion in conventional solar cells. It is shown that solar cells with quantum wells can exhibit a fairly high efficiency of photoconversion in comparison with the photoconversion efficiency of conventional solar cells under the following conditions: (i) the lifetimes of for charge carriers in the quantum wells are longer than those in the barrier material and (ii) the level of doping of the base is not very high. It is established that the maximum efficiency of photoconversion in conventional solar cells is higher than the photoconversion efficiency in solar cells with quantum wells. This efficiency is attained at high doping levels in the base ({approx}3 x 10{sup 18} cm{sup -3} at the parameters used in calculations). This is related to a more intense radiative recombination and also to specific features of screening and charge transport in solar cells with quantum wells at high doping levels. It is shown that, at fairly large values for the degree of concentration of incident radiation, the values for the photoconversion efficiency in solar cells with quantum wells for the low and high levels of doping of the base come closer to each other.

36 MATERIALS SCIENCE↗

A High-Order Low-Order Algorithm with Exponentially Convergent Monte Carlo for Thermal Radiative Transfer

In this paper, we have implemented a new high-order low-order (HOLO) algorithm for solving thermal radiative transfer problems. The low-order (LO) system is based on the spatial and angular moments of the transport equation and a linear-discontinuous finite-element spatial representation, producing equations similar to the standard S 2 equations. The LO solver is fully implicit in time and efficiently resolves the nonlinear temperature dependence at each time step. The high-order (HO) solver utilizes exponentially convergent Monte Carlo (ECMC) to give a globally accurate solution for the angular intensity to a fixed-source pure-absorber transport problem. This global solution is used to compute consistency terms, which require the HO and LO solutions to converge toward the same solution. The use of ECMC allows for the efficient reduction of statistical noise in the Monte Carlo solution, reducing inaccuracies introduced through the LO consistency terms. Finally, we compare results with an implicit Monte Carlo code for one-dimensional gray test problems and demonstrate the efficiency of ECMC over standard Monte Carlo in this HOLO algorithm.

97 MATHEMATICS AND COMPUTING↗

Modeling of plasma beta effects on the island divertor transport in the standard configuration of W7-X

The influence of plasma beta effects on the edge plasma transport in the Wendelstein 7-X standard configuration is studied systematically by using EMC3-EIRENE combined with a 3D equilibrium code named HINT. The magnetic topology changes induced by plasma beta effects are significantly reflected in plasma transport behaviors and heat flux patterns on divertor targets. After validating the modeling strategy by comparisons with experimental data, the extended simulations for high performance plasmas show that the threshold separatrix density for accessing the power detachment is reduced in higher beta plasmas. Compared with the vacuum field case, the impurity radiation distributions with finite beta effects are modified in the magnetic island region. The divertor heat flux is distributed more evenly along the toroidal direction on the strike line at the vertical target. The strike line on the horizontal target moves towards the pumping gap with an increase in the plasma beta. In addition, the different pressure profiles with the same central beta also result in a modified heat flux pattern on the divertor targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Griffin-m

Griffin-m is a MOOSE-based reactor multiphysics application that streamlines the analysis of a variety of nuclear multiphysics simulations, including steady-state and transient radiation transport, core performance, fuel depletion, criticality and decay heat calculations, reprocessing and post-irradiation examination. This streamlining is accomplished via enhanced flexibility of the tools, uniform syntax in the MOOSE framework, dynamic linking of all relevant physics and a single point of execution. The design for flexible multi-physics, multi-radiation, multi-scheme tasks demands and ultimately makes Griffin-m a highly extendable code system. A software quality assurance (SQA) procedure is enforced during Griffin-m development. The Griffin-m version will be the main production version and it includes the MCC3 code, which was originally developed at Argonne National Laboratory to prepare cross sections for fast reactors.

Ortensi, Javier [Idaho National Laboratory (INL), ↗

Monte Carlo Studies for the Radiation Shielding Design of LCLS-II

Intensive Monte Carlo simulations performed with state-of-the-art computation codes are applied to the radiation shielding design of LCLS-II, which will be the extension of Linac Coherent Light Source (LCLS) at SLAC and will use the middle one-third of SLAC two-mile Linac. This paper describes the Monte Carlo studies of the first and last system where electron beams are involved, namely the LCLS-II Injector and the X-ray Transport and Diagnostics System (XTOD).

43 PARTICLE ACCELERATORS↗

Electron Drift Resonance in the MHD-Coupled Comprehensive Inner Magnetosphere-Ionosphere Model

Relativistic electrons in the outer radiation belt are highly dynamic and respond to interplanetary solar wind structures interacting with the Earth's magnetic field. A known mechanism dictating electron dynamics is the drift-resonant interaction with ultralow frequency (ULF) waves. The present work simulates the ring current and radiation belt electron populations in the bounce-averaged, kinetic Comprehensive Inner Magnetosphere-Ionosphere model coupled with the Block Adaptive Tree Solar Wind Roe-type Upwind Scheme global magnetospheric magnetohydrodynamic (MHD) code using an idealized ULF wave solar wind density driver. ULF waves generated with 10 min periods (at 1.67 mHz frequencies) in the MHD model are characterized and the corresponding energization of electrons and radial transport of electron phase space density is presented. The drift-resonant electron energy is determined in the simulation and is consistent with the electron resonance conditions in dipolar magnetic fields. The present results will be an important component of understanding inner magnetospheric dynamics and how these inner magnetospheric populations interact with ULF waves resulting from interplanetary solar wind structures.

Komar, C. M.↗

Electron transport algorithms in the Integrated Tiger Series (ITS) codes - 25576

We describe the three electron-transport algorithms that have been implemented in the ITS Monte Carlo codes. While the underlying cross-section data is similar, each uses a fundamentally unique method, which at a high level are best characterized as condensed history, multigroup, and single scatter. Through a set of comparisons with experimental data and some comparisons of purely numerical results, we discuss various attributes of each of the algorithms and show some of the defects that can affect results. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-107: An Investigation Into Attenuation Effects On the Energy Spectrum for {sup 137}Cs Using Monte Carlo Techniques

Purpose: The calibration of radiation protection instrumentation including ionization chambers, scintillators, and Geiger Mueller (GM) counters used as survey meters are often done using {sup 137}Cs irradiators. During calibration, irradiators use a combination of attenuators with various thicknesses to modulate the beam to a known air-kerma rate. The variations in energy spectra as a result of these attenuators are not accounted for and may play a role in the energy-dependent response of survey meters. This study uses an experimentally validated irradiator geometry modeled in the MCNP5 transport code to characterize the effects of attenuation on the energy spectrum. Methods: A Hopewell Designs G-10 {sup 137}Cs irradiator with lead attenuators of thicknesses of 0.635, 1.22, 2.22, and 4.32 cm, was used in this study. The irradiator geometry was modeled in MCNP5 and validated by comparing measured and simulated percent depth dose (PDD) and cross-field profiles. Variations in MCNP5 simulated spectra with increasing amounts of attenuation were characterized using the relative intensity of the 662 keV peak and the average energy. Results: Simulated and measured PDDs and profiles agreed within the associated uncertainty. The relative intensity of the 662 keV peak for simulated spectra normalized to the intensity of the unattenuated spectra ranged from 0.16% to 100% based on attenuation thickness. The average energy for simulated spectra for attenuators ranged from 582 keV with no attenuation to 653 keV with 5.54 cm of attenuation. Statistical uncertainty for MCNP5 simulations ranged from 0.11% to 3.69%. Conclusion: This study successfully used MCNP5 to validate a {sup 137}Cs irradiator geometry and characterize variations in energy spectra between different amounts of attenuation. Variations in the average energy of up to 12% were determined through simulations, and future work will aim to determine the effects of these differences on survey meter response and calibration.

07 ISOTOPE AND RADIATION SOURCES↗

AN AB INITIO MODEL FOR COSMIC-RAY MODULATION

A proper understanding of the effects of turbulence on the diffusion and drift of cosmic rays (CRs) is of vital importance for a better understanding of CR modulation in the heliosphere. This study presents an ab initio model for CR modulation, incorporating for the first time the results yielded by a two-component turbulence transport model. This model is solved for solar minimum heliospheric conditions, utilizing boundary values chosen so that model results are in reasonable agreement with spacecraft observations of turbulence quantities in the solar ecliptic plane and along the out-of-ecliptic trajectory of the Ulysses spacecraft. These results are employed as inputs for modeled slab and two-dimensional (2D) turbulence energy spectra. The modeled 2D spectrum is chosen based on physical considerations, with a drop-off at the very lowest wavenumbers. There currently exist no models or observations for the wavenumber where this drop-off occurs, and it is considered to be the only free parameter in this study. The modeled spectra are used as inputs for parallel mean free path expressions based on those derived from quasi-linear theory and perpendicular mean free paths from extended nonlinear guiding center theory. Furthermore, the effects of turbulence on CR drifts are modeled in a self-consistent way, also employing a recently developed model for wavy current sheet drift. The resulting diffusion and drift coefficients are applied to the study of galactic CR protons and antiprotons using a 3D, steady-state CR modulation code, and sample solutions in fair to good agreement with multiple spacecraft observations are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 05: Not all geometries are equivalent for magnetic field Fano cavity tests

The coupling of MRI and radiation treatment systems for the application of magnetic resonance guided radiation therapy necessitates a reliable magnetic field capable Monte Carlo (MC) code. In addition to the influence of the magnetic field on dose distributions, the question of proper calibration has arisen due to the several percent variation of ion chamber and solid state detector responses in magnetic fields when compared to the 0 T case (Reynolds et al., Med Phys, 2013). In the absence of a magnetic field, EGSnrc has been shown to pass the Fano cavity test (a rigorous benchmarking tool of MC codes) at the 0.1 % level (Kawrakow, Med.Phys, 2000), and similar results should be required of magnetic field capable MC algorithms. To properly test such developing MC codes, the Fano cavity theorem has been adapted to function in a magnetic field (Bouchard et al., PMB, 2015). In this work, the Fano cavity test is applied in a slab and ion-chamber-like geometries to test the transport options of an implemented magnetic field algorithm in EGSnrc. Results show that the deviation of the MC dose from the expected Fano cavity theory value is highly sensitive to the choice of geometry, and the ion chamber geometry appears to pass the test more easily than larger slab geometries. As magnetic field MC codes begin to be used for dose simulations and correction factor calculations, care must be taken to apply the most rigorous Fano test geometries to ensure reliability of such algorithms.

60 APPLIED LIFE SCIENCES↗

Experimental study of the hydrodynamic trajectory of an x-ray-heated gold plasma

Hydrodynamic processes of radiation-ablated high-Z plasmas have great influence on the x-ray radiation transport both in a high-Z tube with low-Z foam filling and in a low-Z filling indirect drive cavity. Using the intense x-ray radiation to heat a low-Z foam-tamped high-Z gold plate from a half cavity, the hydrodynamic moving process of the x-ray-ablated gold plasma has been studied by an imaging method with Ti He-alpha line emission as the backlighter source. The hydrodynamic trajectory of the x-ray-heated gold plasma was obtained and the average trajectory velocity of (36.5+-1.2) km/s was derived. The experimental trajectory was compared with the simulations using the one-dimensional (1D) RDMG [P. Gu et al., Sci. China, Ser. G 48, 345 (2005)] and two-dimensional (2D) LARED-R [K. Lan et al., Laser Part. Beams 23, 275 (2005)] codes separately. It is shown that the 2D LARED-R code simulated the measured plasma trajectory much better than the 1D RDMG code due to the fact that the lateral x-ray radiation loss was taken into account in the 2D LARED-R but not in the 1D RDMG simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of microstructures in radiation fields using a coupled binary-collision Monte Carlo phase field approach

The simulation of radiation effects in materials broadly falls into two categories. At short time and length scales lies the modeling of primary radiation damage, such as point defect creation, energy deposition, and ballistic mixing. This is followed by the modeling at longer time scales of thermally activated microstructure evolution and defect reactions, such as recombination, clustering, and coarsening. The binary collision Monte Carlo method is an established, numerically efficient method for the computation of primary radiation damage. Conversely, the phase field method is a state of the art method for microstructure evolution on longer time and length scales. Here we present a concurrent coupling of these two methods, overcoming the difference between the discrete object Monte Carlo paradigm for primary radiation damage and the continuum field variable approach for microstructure evolution. The coupling is bidirectional, in which the microstructure evolution in the MOOSE finite element frame- work provides the spatial scattering data set for the charged particle trans- port and receives point defect, mass transport, and heat source terms from the simulated collision cascades that contribute to the field variable evolution. The concurrent coupling scheme is implemented in the code Magpie and demonstrated by investigating patterning for a model irradiated immiscible binary alloy. The results from the coupled binary collision Monte Carlo/phase field simulations reproduce the results of analytical models for phase separation, phase mixing, and patterning, supporting the approach and indicating its utility for modeling real materials systems.

36 MATERIALS SCIENCE↗

FIRST NEW SOLAR MODELS WITH OPAS OPACITY TABLES

Stellar seismology appears more and more as a powerful tool for a better determination of the fundamental properties of solar-type stars. However, the particular case of the Sun is still challenging. For about a decade now, the helioseismic sound-speed determination has continued to disagree with the standard solar model (SSM) prediction, questioning the reliability of this model. One of the sources of uncertainty could be in the treatment of the transport of radiation from the solar core to the surface. In this Letter, we use the new OPAS opacity tables, recently available for solar modeling, to address this issue. We discuss first the peculiarities of these tables, then we quantify their impact on the solar sound-speed and density profiles using the reduced OPAS tables taken on the grids of the OPAL ones. We use the two evolution codes, Modules for Experiments in Stellar Astrophysics and Code Liégeois d’Evolution Stellaire, that led to similar conclusions in the solar radiative zone. In comparison to commonly used OPAL opacity tables, the new solar models are computed for the most recent photospheric composition with OPAS tables and present improvements to the location of the base of the convective zone and to the description of the solar radiative zone in comparison to the helioseismic observations, even if the differences in the Rosseland mean opacity do not exceed 6%. We finally carry out a comparison to a solar model computed with the OP opacity tables.

79 ASTRONOMY AND ASTROPHYSICS↗

Changes in dose with segmentation of breast tissues in Monte Carlo calculations for low-energy brachytherapy

Purpose: To investigate the use of various breast tissue segmentation models in Monte Carlo dose calculations for low-energy brachytherapy. Methods: The EGSnrc user-code BrachyDose is used to perform Monte Carlo simulations of a breast brachytherapy treatment using TheraSeed Pd-103 seeds with various breast tissue segmentation models. Models used include a phantom where voxels are randomly assigned to be gland or adipose (randomly segmented), a phantom where a single tissue of averaged gland and adipose is present (averaged tissue), and a realistically segmented phantom created from previously published numerical phantoms. Radiation transport in averaged tissue while scoring in gland along with other combinations is investigated. The inclusion of calcifications in the breast is also studied in averaged tissue and randomly segmented phantoms. Results: In randomly segmented and averaged tissue phantoms, the photon energy fluence is approximately the same; however, differences occur in the dose volume histograms (DVHs) as a result of scoring in the different tissues (gland and adipose versus averaged tissue), whose mass energy absorption coefficients differ by 30%. A realistically segmented phantom is shown to significantly change the photon energy fluence compared to that in averaged tissue or randomly segmented phantoms. Despite this, resulting DVHs for the entire treatment volume agree reasonably because fluence differences are compensated by dose scoring differences. DVHs for the dose to only the gland voxels in a realistically segmented phantom do not agree with those for dose to gland in an averaged tissue phantom. Calcifications affect photon energy fluence to such a degree that the differences in fluence are not compensated for (as they are in the no calcification case) by dose scoring in averaged tissue phantoms. Conclusions: For low-energy brachytherapy, if photon transport and dose scoring both occur in an averaged tissue, the resulting DVH for the entire treatment volume is reasonably accurate because inaccuracies in photon energy fluence are compensated for by inaccuracies in localized dose scoring. If dose to fibroglandular tissue in the breast is of interest, then the inaccurate photon energy fluence calculated in an averaged tissue phantom will result in inaccurate DVHs and average doses for those tissues. Including calcifications necessitates the use of proper tissue segmentation.

61 RADIATION PROTECTION AND DOSIMETRY↗

MPI + OpenACC: Accelerating radiation transport mini-application, minisweep, on heterogeneous systems

According to the article, architectures are rapidly evolving, and exascale machines are expected to offer billion-way concurrency. We need to rethink algorithms, languages and programming models among other components in order to migrate large scale applications and explore parallelism on these machines. Although directive-based programming models allow programmers to worry less about programming and more about science, expressing complex parallel patterns in these models can be a daunting task especially when the goal is to match the performance that the hardware platforms can offer. One such pattern is wavefront. This paper extensively studies a wavefront-based miniapplication for Denovo, a production code for nuclear reactor modeling. We parallelize the Koch–Baker–Alcouffe (KBA) parallel-wavefront sweep algorithm in the main kernel of Minisweep (the miniapplication) using CUDA 9.0, OpenMP 4.0 (SIMD) and OpenACC 2.6. Our OpenACC implementation running on NVIDIA’s next-generation Volta GPU boasts an 85.06x speedup over serial code, which is larger than CUDA’s 83.72x speedup over the same serial implementation. We also explore the scalability of our solution using MPI to decompose our simulation domain, allowing us to run on many nodes and accelerators present in state-of-the-art HPC systems. Our parallelization effort across platforms also motivated us to define an abstract parallelism model that is architecture independent, with a goal of creating software abstractions that can be used by applications employing the wavefront sweep motif.

Computer Science↗

Dosimetric accuracy of a deterministic radiation transport based {sup 192}Ir brachytherapy treatment planning system. Part III. Comparison to Monte Carlo simulation in voxelized anatomical computational models

Purpose: To compare TG43-based and Acuros deterministic radiation transport-based calculations of the BrachyVision treatment planning system (TPS) with corresponding Monte Carlo (MC) simulation results in heterogeneous patient geometries, in order to validate Acuros and quantify the accuracy improvement it marks relative to TG43. Methods: Dosimetric comparisons in the form of isodose lines, percentage dose difference maps, and dose volume histogram results were performed for two voxelized mathematical models resembling an esophageal and a breast brachytherapy patient, as well as an actual breast brachytherapy patient model. The mathematical models were converted to digital imaging and communications in medicine (DICOM) image series for input to the TPS. The MCNP5 v.1.40 general-purpose simulation code input files for each model were prepared using information derived from the corresponding DICOM RT exports from the TPS. Results: Comparisons of MC and TG43 results in all models showed significant differences, as reported previously in the literature and expected from the inability of the TG43 based algorithm to account for heterogeneities and model specific scatter conditions. A close agreement was observed between MC and Acuros results in all models except for a limited number of points that lay in the penumbra of perfectly shaped structures in the esophageal model, or at distances very close to the catheters in all models. Conclusions: Acuros marks a significant dosimetry improvement relative to TG43. The assessment of the clinical significance of this accuracy improvement requires further work. Mathematical patient equivalent models and models prepared from actual patient CT series are useful complementary tools in the methodology outlined in this series of works for the benchmarking of any advanced dose calculation algorithm beyond TG43.

60 APPLIED LIFE SCIENCES↗

IMPROVED COMPUTATIONAL NEUTRONICS METHODS AND VALIDATION PROTOCOLS FOR THE ADVANCED TEST REACTOR

The Idaho National Laboratory (INL) is in the process of modernizing the various reactor physics modeling and simulation tools used to support operation and safety assurance of the Advanced Test Reactor (ATR). Key accomplishments so far have encompassed both computational as well as experimental work. A new suite of stochastic and deterministic transport theory based reactor physics codes and their supporting nuclear data libraries (HELIOS, KENO6/SCALE, NEWT/SCALE, ATTILA, and an extended implementation of MCNP5) has been installed at the INL. Corresponding models of the ATR and ATRC are now operational with all five codes, demonstrating the basic feasibility of the new code packages for their intended purpose. Of particular importance, a set of as-run core depletion HELIOS calculations for all ATR cycles since August 2009 was successfully completed during 2011. This demonstration supported a decision late in the year to proceed with the phased incorporation of the HELIOS methodology into the ATR fuel cycle management process beginning in 2012. On the experimental side of the project, new hardware was fabricated, measurement protocols were finalized, and the first four of six planned physics code validation experiments based on neutron activation spectrometry were conducted at the ATRC facility. Data analysis for the first three experiments, focused on characterization of the neutron spectrum in one of the ATR flux traps, has been completed. The six experiments will ultimately form the basis for a flexible, easily-repeatable ATR physics code validation protocol that is consistent with applicable ASTM standards.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗