Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rate capability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Percolation connectivity, pore size, and gas apparent permeability: Network simulations and comparison to experimental data: Connectivity, Pore Size, and Gas Permeability

We modeled single-phase gas flow through porous media using percolation networks. Gas permeability is different from liquid permeability. The latter is only related to the geometry and topology of the pore space, while the former depends on the specific gas considered and varies with gas pressure. As gas pressure decreases, four flow regimes can be distinguished as viscous flow, slip flow, transition flow, and free molecular diffusion. Here we use a published conductance model presumably capable of predicting the flow rate of an arbitrary gas through a cylindrical pipe in the four regimes. We incorporated this model into pipe network simulations. We considered 3-D simple cubic, body-centered cubic, and face-centered cubic lattices, in which we varied the pipe radius distribution and the bond coordination number. Gas flow was simulated at different gas pressures. The simulation results showed that the gas apparent permeability k app obeys an identical scaling law in all three lattices, k app ~ (z-z c ) β , where the exponent β depends on the width of the pipe radius distribution, z is the mean coordination number, and z c its critical value at the percolation threshold. Surprisingly, (z-z c ) had a very weak effect on the ratio of the apparent gas permeability to the absolute liquid permeability, k app /k abs , suggesting that the Klinkenberg gas slippage correction factor is nearly independent of connectivity. We constructed models of k app and k app /k abs based on the observed power law and tested them by comparison with published experimental data on glass beads and other materials.

58 GEOSCIENCES↗

Results and Limits of Time-Division Multiplexing for the BICEP Array High-Frequency Receivers

Time-division multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high-frequency receivers, observing at 150 GHz and 220/270 GHz, will have 7776 TES detectors tiled on the focal plane. The constraints set by these two receivers required a redesign of the warm readout electronics. The new version of the standard multichannel electronics, developed and built at the University of British Columbia, is presented here for the first time. BICEP Array operates time-division multiplexing readout technology to the limits of its capabilities in terms of multiplexing rate, noise and cross talk, and applies them in rigorously demanding scientific application requiring extreme noise performance and systematic error control. Finally, future experiments like CMB-S4 plan to use TES bolometers with time-division/SQUID-based readout for an even larger number of detectors.

47 OTHER INSTRUMENTATION↗

Early age hydration and application of blended magnesium potassium phosphate cements for reduced corrosion of reactive metals

Highlights: • Magnesium potassium phosphate cements were studied for nuclear waste encapsulation. • The optimised formulation in this study was determined to be 0.24 w/s ratio. • Different reaction kinetics were discovered for the FA/MKPC and BFS/MKPC binders. • Struvite-K was the only crystalline reaction product observed via in-situ SXPD. • Uranium trials revealed MKPC corrosion was reduced compared to a UK nuclear grout. Magnesium potassium phosphate cements (MKPC) were investigated to determine their efficacy towards retardation of reactive uranium metal corrosion. Optimised low-water content, fly ash (FA) and blast furnace slag (BFS) blended MKPC formulations were developed and their fluidity, hydration behaviour, strength and phase assemblage investigated. In-situ time resolved synchrotron powder X-ray diffraction was used to detail the early age (~60 h) phase assemblage development and hydration kinetics, where the inclusion of BFS was observed to delay the formation of struvite-K by ~14 h compared to FA addition (~2 h). All samples set within this period, suggesting the possible formation of a poorly crystalline binding phase prior to struvite-K crystallisation. Long-term corrosion trials using metallic uranium indicated that MKPC systems are capable of limiting uranium corrosion rates (reduced by half), when compared to a UK nuclear industry grout, which highlights their potential application radioactive waste immobilisation.

36 MATERIALS SCIENCE↗

Conductive overbraid of continuous fiber thermoplastic composite tows

Here, to meet the increasing demand for lightweight materials with multifunctional capabilities, a new high-rate manufacturing method and material system, referred to as M-TOW ® (multifunctional-tow) is introduced. Overbraiding is used to incorporate highly conductive wire onto the continuous fiber reinforced tow (M-TOW ® ), offering a solution for integrating thermal and electrical conductivity into hybrid-molded composite structures. The conductivity performance of different wire configurations are compared before and after forming the M TOW ® , measuring electrical conductivities up to 5.5 x 10 5 S / cm and thermal conductivities up to 21 W / mK. Results conclude that the integration of conductive wires into thermoplastic preforms is a viable means of expanding the functionality of lightweight, high strength composite structures.

3-dimensional reinforcement↗

A machine learning based approach to online electron reconstruction at CLAS12

Online reconstruction is key for monitoring purposes and real time analysis in High Energy and Nuclear Physics experiments. A necessary component of reconstruction algorithms is particle identification that combines information left by a particle passing through several detector components to identify the particle’s type. Of particular interest to electro-production Nuclear Physics experiments such as CLAS12 is electron identification which is used to trigger data recording. A machine learning approach was developed for CLAS12 to reconstruct and identify electrons by combining raw signals at the data acquisition level from several detector components. Here, this approach achieves an electron identification purity above 75% whilst retaining an efficiency close to 100%. The machine learning tools are capable of running at high rates exceeding the data acquisition rates and will allow electron reconstruction in real-time. This work enhances online analyses and monitoring and can contribute to improved triggering at CLAS12. This machine learning driven approach will also be crucial for experiments aiming to transition to streaming readout operations where online reconstruction will be a key component of the data taking paradigm.

Artificial intelligence↗

MeV per Nucleon Ion Irradiation of Nuclear Materials with High Energy Synchrotron X-ray Characterization

The combination of MeV/Nucleon ion irradiation (e.g. 133 MeV Xe) and high energy synchrotron x-ray characterization (e.g. at the Argonne Advanced Photon Source, APS) provides a powerful characterization method to understand radiation effects and to rapidly screen materials for the nuclear reactor environment. Ions in this energy range penetrate ~10 μm into materials. Over this range, the physical interactions vary (electronic stopping, nuclear stopping and added interstitials). Spatially specific x-ray (and TEM and nanoindentation) analysis allow individual quantification of these various effects. Hard x-rays provide the penetration depth needed to analyze even nuclear fuels. Here, this combination of synchrotron x-ray and MeV/Nucleon ion irradiation is demonstrated on U-Mo fuels. A preliminary look at HT-9 steels is also presented. We suggest that a hard x-ray facility with in situ MeV/nucleon irradiation capability would substantially accelerate the rate of discovery for extreme materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and construction of the CMS Outer Tracker for the phase-2 upgrade

The High-Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of 3000–4000 fb −1 over 10 years of operation with the peak instantaneous luminosity reaching about 5–7.5 × 1 0 34 cm −2 s −1 . During Long Shutdown 3, several components of the CMS detector will undergo major improvements, called Phase-2 upgrades, to be able to operate in the challenging environment of the HL-LHC. The current CMS tracker will be replaced. The Phase-2 Outer Tracker (OT) will have increased radiation tolerance, higher granularity, and the capability to handle higher data rates. Moreover, the OT will provide tracking information to the Level-1 trigger for the first time at a hadron collider, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made of modules with two closely-spaced silicon sensors read out by front-end ASICs that can correlate hits in the two sensors to create short track segments, used in the Level-1 track finder. The modules come in two flavors: strip-strip and pixel-strip, containing different sensor configurations and multiple ASICs. This contribution presents the Phase-2 OT, the finalization of the OT module design, and the quality assurance and control procedures used to ensure that the modules fulfill both the specifications from the assembly steps as well as the proper communication among the ASICs.

Zoi, Irene [Fermilab] (ORCID:0000000257389446)↗

Performance measurements of the electromagnetic calorimeter and readout electronics system for the DarkQuest experiment

Here, this paper presents performance measurements of a new readout electronics system based on silicon photomultipliers for the PHENIX electromagnetic calorimeter. Installation of the lead-scintillator Shashlik style calorimeter into the SeaQuest/SpinQuest spectrometer has been proposed to broaden the experiment’s dark sector search program, an upgrade known as DarkQuest. The calorimeter and electronics system were subjected to testing and calibration at the Fermilab Test Beam Facility. Detailed studies of the energy response and resolution, as well as particle identification capabilities, were performed. The background rate in the actual experimental environment was also examined. The system is found to be well-suited for a dark sector search program on the Fermilab 120 GeV proton beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acoustic focusing of microplastics in microfabricated and steel tube devices: An experimental study on the effects from particle size and medium density

The contamination of aquatic systems with microplastics is becoming a severe threat to living organisms. Microplastics found in the environment consist of a wide range of particle sizes thus give rise to several challenges to current purification methods. Acoustic focusing has been utilized as a particle concentrating method in biological and non-biological applications. In this study, we investigate the feasibility of using acoustic focusing technology to isolate microplastics in aqueous samples and find that a two-stage mechanism is essential to concentrate microplastics of wide size ranges of the same material. We demonstrate for the first time experimentally that when the particle size is comparable to the resonance wavelength, they deviate from typical pressure nodal focusing and show pressure antinodal focusing. Further, we have expanded microplastics isolation beyond microfluidic systems and demonstrate their extraction capabilities relatively at higher flow rates using microplastics of polystyrene, polyethylene, and polymethyl methacrylate ranging from 6 µm to 300 µm diameter and in devices fabricated with cylindrical steel tubes. We could extract 70% of microplastics smaller than 180 µm and 82% of microplastics greater than 180 µm in diameter from an aqueous sample at a flow rate of 12 mL/min. In conclusion, we demonstrate that small microplastics focus on acoustic pressure nodes regardless of the medium density. However, focusing of large microplastics of the same material depends on the medium density.

42 ENGINEERING↗

Performance of a Silicon-Drift Detector in 200kV TEM Environments

Silicon-drift detectors for energy-dispersive spectroscopy have gained increasing acceptance in the field principally because of their outstanding capabilities for high count-rate performance coupled with excellent resolution [1,2]. Improvements in design in the last few years have overcome some early disadvantages of the SDD in comparison to Si(Li) detectors, which have dominated the field for nearly 4 decades. Amongst these are detection efficiency in the low-energy regime, and a dropoff in detection efficiency at higher energies above 10keV. The former disadvantage has been largely overcome by generational design improvements to minimize the effective dead layer at the entrance window, so that present detectors provide better performance in the low-energy regime than Si(Li) detectors. In the latter case, higher energy peak detection performance has been improved by increasing the thickness of the detector. This is important primarily for the use of the SDD in a TEM environment, where very high count rates are not encountered due to the thin sample geometry. Also of importance for incorporation of an SDD into a TEM column is the lack of need for liquid nitrogen, since the SDD is chilled by a thermoelectric cooler. This is an advantage for SEM and microprobe operation also, but high-resolution TEMs (particularly aberration-corrected instruments) are more sensitive to vibration than SEMs or microprobes, so the much reduced form factor of an air-cooled SDD relative to a Si(Li) detector with a large LN2 dewar is desirable for use on the TEM. We have recently tested two Bruker C

200kV TEM↗

Nanostructured Metal Hydrides for Hydrogen Storage

Knowledge and foundational understanding of phenomena associated with the behavior of materials at the nanoscale is one of the key scientific challenges toward a sustainable energy future. Size reduction from bulk to the nanoscale leads to a variety of exciting and anomalous phenomena due to enhanced surface-to-volume ratio, reduced transport length, and tunable nanointerfaces. Nanostructured metal hydrides are an important class of materials with significant potential for energy storage applications. Hydrogen storage in nanoscale metal hydrides has been recognized as a potentially transformative technology, and the field is now growing steadily due to the ability to tune the material properties more independently and drastically compared to those of their bulk counterparts. The numerous advantages of nanostructured metal hydrides compared to bulk include improved reversibility, altered heats of hydrogen absorption/desorption, nanointerfacial reaction pathways with faster rates, and new surface states capable of activating chemical bonds. This review aims to summarize the progress to date in the area of nanostructured metal hydrides and intends to understand and explain the underpinnings of the innovative concepts and strategies developed over the past decade to tune the thermodynamics and kinetics of hydrogen storage reactions. Furthermore, these recent achievements have the potential to propel further the prospects of tuning the hydride properties at nanoscale, with several promising directions and strategies that could lead to the next generation of solid-state materials for hydrogen storage applications.

08 HYDROGEN↗

Multi-component background learning automates signal detection for spectroscopic data

Abstract Automated experimentation has yielded data acquisition rates that supersede human processing capabilities. Artificial Intelligence offers new possibilities for automating data interpretation to generate large, high-quality datasets. Background subtraction is a long-standing challenge, particularly in settings where multiple sources of the background signal coexist, and automatic extraction of signals of interest from measured signals accelerates data interpretation. Herein, we present an unsupervised probabilistic learning approach that analyzes large data collections to identify multiple background sources and establish the probability that any given data point contains a signal of interest. The approach is demonstrated on X-ray diffraction and Raman spectroscopy data and is suitable to any type of data where the signal of interest is a positive addition to the background signals. While the model can incorporate prior knowledge, it does not require knowledge of the signals since the shapes of the background signals, the noise levels, and the signal of interest are simultaneously learned via a probabilistic matrix factorization framework. Automated identification of interpretable signals by unsupervised probabilistic learning avoids the injection of human bias and expedites signal extraction in large datasets, a transformative capability with many applications in the physical sciences and beyond.

Ament, Sebastian E.↗

Photosynthetic responses to light levels in drought-tolerant novel peanut (Arachis hypogaea L) genotypes

Abstract Drought is a significant abiotic stressor that reduces peanut production because it alters photosynthetic activity and impacts crop growth. Therefore, developing drought-tolerant peanut genotypes capable of maintaining higher photosynthetic rates (A) under stress is crucial. This study assessed changes in photosynthetic and chlorophyll fluorescence responses to light (photosynthetic photon flux density, PPFD) in newly bred drought-tolerant peanut genotypes. Ten genotypes [NM-3, NM-5, NM-6, NM-23, NM-69, NM-70, NM-74, NM-77, V-C, and C-76–16] were evaluated under full irrigation (FC 100 ) and deficit irrigation (FC 50 ) in a split-plot design with four replications in a greenhouse. Under high PPFD levels, genotype NM-5 with deficit irrigation exhibited significantly higherA, stomatal conductance (gs), quantum efficiency of photosystem II (ΦPSII), and electron transport rate (ETR) by 40–59%, 135–525%, 31–212%, and 31–102%, respectively, than check varieties (V-C and C-76–16) and other genotypes. The NM-74 and NM-77 genotypes also performed well under deficit irrigations but with slightly lowerA,gs, ΦPSII, and ETR. Genotypes NM-5, NM-23, NM-74, and NM-77 exhibited significantly higher quantum efficiency of photosystem II (Fv’/Fm’) and photochemical quenching (qP) with higher light intensities in the daily cycle under deficit irrigation. The decline in ETR at the same PPFD levels in NM-3, NM 69, NM-70, and C-76–16 indicated photoinhibition or saturation of the photosynthetic apparatus compared to other genotypes. Concurrently, FC 100 irrigation level minimizes photoinhibition, enhancingA,gs, ΦPSII, and ETR in the genotypes than FC 50 . Therefore, we conclude that NM-5, NM-74, and NM-77 genotypes can perform better under water deficit environments. As such, chlorophyll fluorescence parameters Fv’/Fm’ and qP can be considered for selective breeding to enhance photosynthetic efficiencies.

Science & Technology - Other Topics↗

Perspective on One Decade of Laser Propulsion Research at Air Force Research Laboratory

The Air Force Laser Propulsion Program spanned nearly 10-years and included about 35-weeks of experimental research with the Pulsed Laser Vulnerability Test System of the High Energy Laser Systems Test Facility at White Sands Missile Range, New Mexico, WSMR/HELSTF/PLVTS. PLVTS is a pulsed CO2 laser that produces up to 10 kW of power in {approx}10 cm{sup 2} spot at wavelength of 10.6 microns. The laser is capable of a pulse repetition rate up to 25 Hz, with pulse durations of about 20 microseconds. During the program basic research was conducted on the production of propulsion thrust from laser energy through heating of air and ablation of various candidate rocket propellant fuels. Flight tests with an ablation fuel (Delrin) and air were accomplished with a model Laser Lightcraft vehicle that was optimized for propulsion by the PLVTS at its maximum power output, 10 kW at 25 Hz, 400 J/pulse. Altitudes exceeding 200-feet were achieved with ablation fuels. The most recent contributions to the technology included development of a mini-thruster standard for testing of chemically enhanced fuels and theoretical calculations on the performance of formulations containing ammonium nitrate and Delrin. Results of these calculations will also be reported here.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High repetition rate plasma mirror device for attosecond science

This report describes an active solid target positioning device for driving plasma mirrors with high repetition rate ultra-high intensity lasers. The position of the solid target surface with respect to the laser focus is optically monitored and mechanically controlled on the nm scale to ensure reproducible interaction conditions for each shot at arbitrary repetition rate. We demonstrate the target capabilities by driving high-order harmonic generation from plasma mirrors produced on glass targets with a near-relativistic intensity few-cycle pulse laser system operating at 1 kHz. During experiments, residual target surface motion can be actively stabilized down to 47 nm (root mean square), which ensures sub-300-as relative temporal stability of the plasma mirror as a secondary source of coherent attosecond extreme ultraviolet radiation in pump-probe experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel continuous simulated tempering and its applications in large-scale molecular simulations

In this paper, we introduce a parallel continuous simulated tempering (PCST) method for enhanced sampling in studying large complex systems. It mainly inherits the continuous simulated tempering (CST) method in our previous studies [C. Zhang and J. Ma, J. Chem. Phys. 130, 194112 (2009); C. Zhang and J. Ma, J. Chem. Phys. 132, 244101 (2010)], while adopts the spirit of parallel tempering (PT), or replica exchange method, by employing multiple copies with different temperature distributions. Differing from conventional PT methods, despite the large stride of total temperature range, the PCST method requires very few copies of simulations, typically 2–3 copies, yet it is still capable of maintaining a high rate of exchange between neighboring copies. Furthermore, in PCST method, the size of the system does not dramatically affect the number of copy needed because the exchange rate is independent of total potential energy, thus providing an enormous advantage over conventional PT methods in studying very large systems. The sampling efficiency of PCST was tested in two-dimensional Ising model, Lennard-Jones liquid and all-atom folding simulation of a small globular protein trp-cage in explicit solvent. The results demonstrate that the PCST method significantly improves sampling efficiency compared with other methods and it is particularly effective in simulating systems with long relaxation time or correlation time. We expect the PCST method to be a good alternative to parallel tempering methods in simulating large systems such as phase transition and dynamics of macromolecules in explicit solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Variable location channels to improve efficiency and precision for direct ∇ T e measurements and high spatial resolution T e -profile measurements using electron cyclotron emission

Electron cyclotron emission (ECE) diagnostics that use variable location channels based on yttrium iron garnet (YIG) bandpass filters improve the precision and the efficiency of measurements of electron temperature (T e ) profiles and fluctuations (δT e ). These variable frequency filters were substituted for fixed frequency filters in the intermediate frequency section to achieve the required higher resolution over a target radial range, just before the experiment. In this paper, we present the proof-of-principle for high temporal resolution measurement of the electron temperature gradient, via real-time slewing of a YIG filter for relocation of an ECE channel during a long pulse. The key component is the application of YIG tunable filters with their narrow bandwidth and capability for a high slew rate of their center frequency. This application permits fast relocation of the ECE channels for direct measurement of the gradient and close spacing of channels to investigate the magnetic island’s dynamic behavior.

47 OTHER INSTRUMENTATION↗

Extreme ultraviolet time- and angle-resolved photoemission setup with 21.5 meV resolution using high-order harmonic generation from a turn-key Yb:KGW amplifier

Characterizing and controlling electronic properties of quantum materials require direct measurements of nonequilibrium electronic band structures over large regions of momentum space. Here, we demonstrate an experimental apparatus for time- and angle-resolved photoemission spectroscopy using high-order harmonic probe pulses generated by a robust, moderately high power (20 W) Yb:KGW amplifier with a tunable repetition rate between 50 and 150 kHz. By driving high-order harmonic generation (HHG) with the second harmonic of the fundamental 1025 nm laser pulses, we show that single-harmonic probe pulses at 21.8 eV photon energy can be effectively isolated without the use of a monochromator. The on-target photon flux can reach 5 × 1010 photons/s at 50 kHz, and the time resolution is measured to be 320 fs. The relatively long pulse duration of the Yb-driven HHG source allows us to reach an excellent energy resolution of 21.5 meV, which is achieved by suppressing the space-charge broadening using a low photon flux of 1.5 × 108 photons/s at a higher repetition rate of 150 kHz. The capabilities of the setup are demonstrated through measurements in the topological semimetal ZrSiS and the topological insulator Sb2−xGdxTe3.

Liu, Yangyang↗