Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Modeling the Residual Stresses in Reactive Resins-Based Materials: a Case Study of Photo-Sensitive Composites for Dental Applications

Residual stresses in reactive resins-based composites are associated to the net volumetric contraction (shrinkage) arising during the cross-linking reactions. Depending on the restoration geometry (the ratio of the free surface area to the volume of the cavity) the frozen-in stresses can be as high as the strength of the dental composites. This is the main reason why the effectiveness and then the durability of restorations with composites remains quite lower than those realized with metal alloys based materials. In this paper we first explore the possibility to circumvent the mathematical complexity arising from the determination of residual stresses in reactive systems three-dimensionally constrained. Then, the results of our modeling approach are applied to a series of commercially available composites showing that almost all samples develop residual stresses such that the restoration undergoes failure as soon as it is realized.

36 MATERIALS SCIENCE↗

Horizontal 1 K refrigerator with novel loading mechanism for polarized solid targets

We describe a helium evaporation refrigerator used to cool dynamically polarized proton and deuteron targets for electron-scattering experiments using the CEBAF Large Acceptance Spectrometer CLAS12 at Jefferson Lab. The geometry of the CLAS12 detector systems places severe design and construction constraints on the refrigerator and its ancillary equipment, resulting in a horizontal cryostat with a length of 4 m. The 16 cm 3 target samples, consisting of frozen ammonia (NH 3 or ND 3 ), are loaded at the upstream end of the cryostat and moved to the beam-interaction region using a novel transport mechanism. At this location they are cooled with superfluid helium and polarized via dynamic nuclear polarization at 1 K and 5 T. In this manner samples can be replaced and cooled to 1 K in about 30 minutes without disturbing any elements of the electron beam line or particle detection system. In conclusion, we estimate that this method saved 18 days of valuable beam time over the course of a recent, 88-day long experiment.

Evaporation refrigerator↗

Design of a radial collimator for the SEQUOIA direct geometry chopper spectrometer

The SEQUOIA direct geometry chopper spectrometer at the Spallation Neutron Source is considering acquisition of a radial collimator. We present here Monte-Carlo calculations examining the proposed collimator's performance. Through comparison of calculations with and without sample environments in place, one can determine appropriate parameters to use in the collimator design. The numerical results provide enough detail to determine the angular collimation for the radial collimator.

47 OTHER INSTRUMENTATION↗

Fiber-Coupled Substrate-Integrated Hollow Waveguides: An Innovative Approach to Mid-infrared Remote Gas Sensors

Here, in this study, an innovative approach based on fiberoptically coupled substrate-integrated hollow waveguide (iHWG) gas cells for the analysis of low sample volumes suitable for remote broad- and narrow-band mid-infrared (MIR; 2.5–20 μm) sensing applications is reported. The feasibility of remotely addressing iHWG gas cells, configured in a double-pass geometry via a reflector, by direct coupling to a 7-around-1 mid-infrared fiber bundle is demonstrated, facilitating low-level hydrocarbon gas analysis. For comparison studies, two iHWGs with substrate dimensions of 50 × 50 × 12 mm (L × W × H) and geometric channel lengths of 138 and 58.5 mm, serving as miniature light-guiding gas cells, were fiber-coupled to a Fourier transform infrared spectrometer enabling broadband MIR sensing. In addition to the fundamental feasibility of this concept, the achievable sensitivity toward several gaseous hydrocarbons and the reproducibility of assembling the fiber-iHWG interface were investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deformation T-Cup: A new multi-anvil apparatus for controlled strain-rate deformation experiments at pressures above 18 GPa

A new multi-anvil deformation apparatus, based on the widely used 6-8 split-cylinder, geometry, has been developed which is capable of deformation experiments at pressures in excess of 18 GPa at room temperature. In 6-8 (Kawai-type) devices eight cubic anvils are used to compress the sample assembly. In our new apparatus two of the eight cubes which sit along the split-cylinder axis have been replaced by hexagonal cross section anvils. Combining these anvils hexagonal-anvils with secondary differential actuators incorporated into the load frame, for the first time, enables the 6-8 multi-anvil apparatus to be used for controlled strain-rate deformation experiments to high strains. Testing of the design, both with and without synchrotron-X-rays, has demonstrated the Deformation T-Cup (DT-Cup) is capable of deforming 1–2 mm long samples to over 55% strain at high temperatures and pressures. To date the apparatus has been calibrated to, and deformed at, 18.8 GPa and deformation experiments performed in conjunction with synchrotron X-rays at confining pressures up to 10 GPa at 800 °C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rock-salt structure lithium deuteride formation in liquid lithium with high-concentrations of deuterium: a first-principles molecular dynamics study

Because of lithium's possible use as a first wall material in a fusion reactor, a fundamental understanding of the interactions between liquid lithium (Li) and deuterium (D) is important. Here, we predict structural and dynamical properties of liquid Li samples with high concentrations of D, as derived from first-principles molecular dynamics simulations. Liquid Li samples with four concentrations of inserted D atoms (LiD$_{\beta}$ , $\beta =0.25$ , 0.50, 0.75, and 1.00) are studied at temperatures ranging from 470 to 1143 K. Densities, diffusivities, pair distribution functions, bond angle distribution functions, geometries, and charge transfer between Li and D atoms are calculated and analyzed. The analysis suggests liquid–solid phase transitions can occur at some concentrations and temperatures, forming rock-salt LiD within liquid Li. Finally, we observed the formation of some D 2 molecules at high D concentrations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle size influence on material properties of BaTiO 3 ceramics fabricated using freeze-form extrusion 3D printing

Barium titanate (BaTiO 3 ; BTO) is a well-known lead-free piezoelectric material commonly used for sensors and actuators applications. There are several traditional methods to fabricate bulk BTO ceramics; however, most of those methods have restrictions regarding being able to produce a functional and complex shape for specific application needs. Recently, additive manufacturing techniques such as binder jetting have enabled the fabrication of complex designs of piezoelectric ceramics. However, the density achieved is relatively low thus narrowing their applications. This paper presents the fabrication of high-density BaTiO 3 ceramics using Freeze-form Extrusion Fabrication (FEF). The influence on material properties for different ceramic particle size was assessed. It was found that parts printed using finer BaTiO 3 particle sizes achieved better results in terms of density, piezoelectric, and dielectric properties. For this study, the 100 nm BaTiO 3 samples achieved 85.24% density, a high piezoelectric property of 204.61pC/N and dielectric permittivity of 2551. These results demonstrated the feasibility of using FEF additive manufacturing to fabricate high-quality functional ceramics with designed geometry in a mold-free fashion.

36 MATERIALS SCIENCE↗

Upper critical magnetic field and multiband superconductivity in artificial high-𝑇 𝑐 superlattices of nano quantum wells

Artificial high-T c superlattices (AHTS) composed of quantum building blocks with tunable superconducting critical temperature have been synthesized by engineering their nanoscale geometry using the Bianconi-Perali Valletta (BPV) two-gap superconductivity theory. These quantum heterostructures consist of quantum wells made of superconducting, modulation-doped Mott insulators (S), confined by a metallic (N) potential barrier. The lattice geometry has been carefully engineered to induce the predicted Fano-Feshbach shape resonance between the gaps, near a topological Lifshitz transition. Here, we validate the BPV theory by providing compelling experimental evidence that AHTS samples, at the peak of the superconducting dome, exhibit resonant two-band, two-gap superconductivity. This is demonstrated by measuring the temperature dependence of the upper critical magnetic field, μ 0 H c2 , in samples with superlattice periods 3.3 < d < 5.28 nm and L/d ratios close to the magic value 2/3 (where L is the thickness of the superconducting La 2 CuO 4 layer and d is the superlattice period). Here, the data reveal the predicted upward concavity in H c2 (T) and a characteristic kink in the coherence length as a function of temperature, confirming the predicted two-band superconductivity with Fermi velocity ratio ≈ 0.25 and significant pair-exchange term among the two condensates.

Heterostructures↗

Dissociation dynamics of the water dication following one-photon double ionization. I. Theory

The measurement of the triple differential cross section in the body frame for double photoionization of a molecule can be made in principle by detecting the ionic fragments and the two photoelectrons in coincidence - but only if the dynamics and geometry of dissociation of the doubly charged molecular ion are known. A classical trajectory study of the nine lowest states of the water dication is presented using high quality ab initio potential-energy surfaces. Sampling from a semiclassical initial distribution of positions and momenta is used to approximate ionization from the Frank-Condon region of the ground vibrational state of neutral H 2 O. Excellent agreement in comparison with preliminary experimental momentum imaging measurements of double photoionization of water show that eight dication states can be unambiguously identified in the experiment with the aid of theory. In conclusion, the theoretical trajectory results allow body frame measurements of double photoionization to yield all eight states even though the usual assumption of direct dissociation, the "axial recoil" approximation, breaks down for three of the dication electronic states seen in the experiment.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-CAMPUS-T-02: Exploring Radiation Acoustics CT Dosimeter Design Aspects for Proton Therapy

Purpose: Investigate the design aspects and imaging dose capabilities of the Radiation Acoustics Computed Tomography (RA CT) dosimeter for Proton induced acoustics, with the objective to characterize a pulsed pencil proton beam. The focus includes scanner geometry, transducer array, and transducer bandwidth on image quality. Methods: The geometry of the dosimeter is a cylindrical water phantom (length 40cm, radius 15cm) with 71 ultrasound transducers placed along the length and end of the cylinder to achieve a weighted set of projections with spherical sampling. A 3D filtered backprojection algorithm was used to reconstruct the dosimetric images and compared to MC dose distribution. First, 3D Monte Carlo (MC) Dose distributions for proton beam energies (range of 12cm, 16cm, 20cm, and 27cm) were used to simulate the acoustic pressure signal within this scanner for a pulsed proton beam of 1.8x107 protons, with a pulse width of 1 microsecond and a rise time of 0.1 microseconds. Dose comparison within the Bragg peak and distal edge were compared to MC analysis, where the integrated Gaussian was used to locate the 50% dose of the distal edge. To evaluate spatial fidelity, a set of point sources within the scanner field of view (15×15×15cm3) were simulated implementing a low-pass bandwidth response function (0 to 1MHz) equivalent to a multiple frequency transducer array, and the FWHM of the point-spread-function determined. Results: From the reconstructed images, RACT and MC range values are within 0.5mm, and the average variation of the dose within the Bragg peak are within 2%. The spatial resolution tracked with transducer bandwidth and projection angle sampling, and can be kept at 1.5mm. Conclusion: This design is ready for fabrication to start acquiring measurements. The 15 cm FOV is an optimum size for imaging dosimetry. Currently, simulations comparing transducer sensitivity, bandwidth, and proton beam parameters are being evaluated to assess signal-to-noise.

07 ISOTOPE AND RADIATION SOURCES↗

Size-scaling of tensile failure stress in boron carbide

Weibull strength-size-scaling in a rotary-ground, hot-pressed boron carbide is described when strength test coupons sampled effective areas from the very small (~ 0.001 square millimeters) to the very large (~ 40,000 square millimeters). Equibiaxial flexure and Hertzian testing were used for the strength testing. Characteristic strengths for several different specimen geometries are analyzed as a function of effective area. Characteristic strength was found to substantially increase with decreased effective area, and exhibited a bilinear relationship. Machining damage limited strength as measured with equibiaxial flexure testing for effective areas greater than ~ 1 mm2 and microstructural-scale flaws limited strength for effective areas less than 0.1 mm2 for the Hertzian testing. The selections of a ceramic strength to account for ballistically-induced tile deflection and to account for expanding cavity modeling are considered in context with the measured strength-size-scaling.

36 MATERIALS SCIENCE↗

Development of a Tender-Energy Microprobe for Geosciences at NSLS and NSLS-II

This funding is to develop a new Synchrotron user facility for microbeam X-ray absorption spectroscopy (XAS) and quantitative X-ray fluorescence (XRF) imaging, at the National Synchrotron Light Source (NSLS) and NSLS-II. It includes design, purchase of components, and construction of the microprobe endstation and controls. Initial development, commissioning, and application is ongoing at NSLS Beamline X15B, with planned transition in 2014-15 to the NSLS-II TES (Tender-Energy Spatially Resolved X-ray Absorption Spectroscopy) beamline. It is optimized for the “tender” energy range of 1-5 keV, reaching up to 8 keV. Thus it uniquely covers the K absorption edges of critical elements Mg, Al, Si, P, S, Cl, and Ca, and can reach up to Co. A stable, high-flux microbeam focus, user-tunable from ~50 to ~5 microns, has been achieved using two-stage achromatic focusing. Existing beamline optics collimate, monochromate, and macro-focus the X-ray beam to ~1 mm at a secondary source aperture (SSA). Beam from the SSA is then re-focused by a pair of mirrors in KB geometry to the microbeam scale. Size of the microbeam is tunable, at the expense of flux, by adjusting the size of the SSA as a virtual source. The new experimental endstation consists of 1) a sample chamber operable as a radiation enclosure with helium atmosphere to facilitate measurements in this energy range, 2) the KB microfocusing optics, 3) a sample-positioning stage for raster-scanning and positioning the sample, 4) X-ray fluorescence detectors, an existing Ge detector for low-signal sensitivity and a new Si detector for high count rates, 5) an optical camera for viewing samples and locating target locations, 6) beam intensity monitors and diagnostics, and 7) controls and data acquisition system. An important aspect of this project is the added capability for fast, on-the-fly scanning of the monochromator (energy), required for fast XAS and advanced XAS imaging. This instrument will be available for initial PI and Co-I measurements, and for General Users to apply for beamtime to use, at NSLS X15B for the remaining operation of NSLS, to September 30, 2014. Phase two of this project will transition this facility, both the primary optics and the endstation, to NSLS-II after NSLS ceases operation. While this transition itself is beyond the scope of the current grant, preparation and planning for it is included.

58 GEOSCIENCES↗

Humin to Human: Organic carbon, sediment, and water fluxes along river corridors in a changing world

This is a presentation with slides on What does it mean to be human? ...humin?; River flow and Hydrographs; Snake River altered hydrograph (Marston et al., 2005); Carbon dynamics are important in rivers; Rivers and streams as carbon sink; Reservoirs for organic carbon; Study sites in Colorado; River morphology; Soil sample collection; Surveys at RMNP; Soil organic carbon content at RMNP; Abandoned channels and Cutoffs; East River channel migration and erosion; Linking hydrology to floodplain sediment flux; Impact of Extreme Floods on Floodplain Sediment; Channel Geometry: RMNP; Beavers dams and multithread channels; Geomorphology and carbon in N. St. Vrain Creek; Geomorphology and carbon along the East River; Geomorphology and carbon in N. St. Vrain Creek; San Marcos River, etc.

54 ENVIRONMENTAL SCIENCES↗

5.5 Hybrid Additively Manufactured Tooling for Large Composite Structures

This program sought to lower tooling costs for tightly toleranced, large composite aerostructures by using large format additive manufacturing (LFAM). LFAM tooling has the potential to lower tooling costs, but the large and unpredictable thermal expansion of polymer-based tooling did not previously allow for the production of large structures made with high performance resins requiring 350 deg F cures. Geometric tolerance issues and demolding concerns continued to arise. The proposed approach for this work was to print a thin shell via additive manufacturing that would be used as a scaffold for a conventional tooling prepreg. The prepreg would be laminated and cured onto both sides of the shell, creating a tool with a sandwich construction. The cured prepreg would then be machined and serve as the tooling surface. In addition to providing a clean, pit-free surface, the prepreg stiffness and low thermal expansion would physically restrain the AM shell and prevent it from expanding during thermal cycling, thus preventing any geometric mismatch between the nominal and actual part dimensions. A stair-step approach was taken to prove out this approach. Coupon level testing was done to ensure a good bond was possible between the AM shell and the tooling prepreg. These samples were also used to determine the amount of prepreg needed to achieve the desired coefficient of thermal expansion (CTE). The project team than progressed to a subscale tool measuring two feet in length. The geometry used was a C-section spar from Airbus’ Wing of Tomorrow program. A hybrid tool, using the AM shell and tooling prepreg, was made, and a composite part was fabricated with the tool. Dimensional scans of the tool and part indicated that the desired CTE was achieved with the tool. A second tooling approach was taken to reduce risk. In this approach, a subscale tool of the same geometry as previously mentioned was created, but the tool was entirely constructed of the tooling prepreg. AM was used to print a “master” that was then used to fabricate the tool by creating a splash off of the master using tooling prepreg. The innovation was that the master was not machined, but rather, was used right off the printer after a small amount of surface preparation. Removing this machining step was thought to make this approach economically viable when compared to conventional master fabrication. As before, the tool was used to fabricate a part and tested for dimensional accuracy. For the conclusion of the program, a ten-foot tool was created using the hybrid tool approach. The geometry also came from the Airbus C-section spar previously mentioned. Some difficulty arose in accurately predicting the geometry of the tool after laminating the tooling prepreg, resulting in multiple material additions and a tool geometry change. A part was fabricated in an autoclave using the tool. A cost savings of almost 50% was achieved on the subscale tool in both the hybrid and master-style tool, but the savings dropped considerably as the tool length increased in the full-scale tool. Given the less than expected cost savings and added complexity of the tool construction, it is suggested that the master-style tool is best for immediate commercialization for larger tools (although it may be appropriate for smaller, table-top size tools). Since its construction is very similar to conventionally made composite tooling, there already exists a broad supply chain for building the tool, and project partner Additive Engineering Solutions (AES) is well acquainted with the design and build of the AM master needed.

36 MATERIALS SCIENCE↗

Miniature Instrumentation for SIPR (Subsurface Ice PRobe)

Ice coring has proved to be a valuable scientific tool for determining climate history on Earth. The goal of the SIPR project is to develop a simple extraterrestrial ice sampling method of comparable value to coring. The SIPR probe works by melting its way through glacial ice, pumping the melt water to the surface for analysis as it descends hundreds of meters. The specific geometry of the probe, along with size and power constraints, requires creative diagnostic instrumentation. A thin, vertically strung heated filament will provide continuous-level monitoring of water in down-hole containers. The filament has an appreciable temperature coefficient to resistance (TCR), so as water cools the wire, its resistance decreases. At a constant electrical current, the voltage across the filament varies linearly with water level.

Ostmo, Karl P.↗

Convective Heat Transfer Scaling of Ignition Delay and Burning Rate with Heat Flux and Stretch Rate in the Equivalent Low Stretch Apparatus

To better evaluate the buoyant contributions to the convective cooling (or heating) inherent in normal-gravity material flammability test methods, we derive a convective heat transfer correlation that can be used to account for the forced convective stretch effects on the net radiant heat flux for both ignition delay time and burning rate. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone heater to minimize buoyant effects while at the same time providing a forced stagnation flow on the sample, which ignites and burns as a ceiling fire. Ignition delay and burning rate data is correlated with incident heat flux and convective heat transfer and compared to results from other test methods and fuel geometries using similarity to determine the equivalent stretch rates and thus convective cooling (or heating) rates for those geometries. With this correlation methodology, buoyant effects inherent in normal gravity material flammability test methods can be estimated, to better apply the test results to low stretch environments relevant to spacecraft material selection.

Olson, Sandra↗

Quantification of Uncertainties and Correlations in Criticality Experiments With SCALE

Uncertainties in benchmark keff values due to uncertainties in individual components, such as geometry and material compositions, are rigorously quantified and documented in evaluations provided in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). Correlations between the uncertainties may affect not only the overall uncertainty for a series of benchmarks but also the magnitude of computational biases and bias uncertainties quantified by validation methods. The impact of the correlations in experimental uncertainties is especially important in the use of advanced validation methods such as Generalized Linear Least Squares (GLLS), as implemented in the SCALE TSURFER code. In a recent study, it was demonstrated that biases computed with GLLS procedures vary by as much as 75%, depending on the selection of the experimental uncertainty correlation value. of the >4000 benchmarks documented in the IHECSBE; experimental correlation data are only available in the DICE database tool for ~60 benchmarks. Additional data are available in DICE to identify the potential for correlations between evaluations, but the values of correlations are not quantified. The new Sampler module of SCALE provides stochastic capabilities to quantify uncertainties and correlations in keff or any other measured value for one or more benchmark experiments due to uncertainties in individual sources of uncertainty, such as geometry and material composition. The values for individual parameters in the input model are randomly modified within the reported uncertainty, and a distribution function and a series of perturbed keff values are obtained. Where sufficient samples are made, the distribution of the perturbed keff values is used to determine the uncertainty in the keff due to uncertainties in the input parameters. In cases where the same uncertainty parameters influence multiple experiments, such as where the same fissile solution or fuel rods are used for many critical measurements, the simultaneous perturbation of an uncertain parameter for multiple cases provides the correlation in keff uncertainties between the different configurations. The parametric uncertainty capabilities of Sampler for a single system are demonstrated for a benchmark exercise from the Organization for Economic Cooperation and Development (OECD) Nuclear Energy Agency (NEA) Working Party on Nuclear Criticality Safety (WPNCS) Expert Group on Uncertainty Analysis for Criticality Safety Assessment (UACSA) Phase II benchmark. Sampler is further applied to quantify correlations among benchmarks from a series of highly enriched uranium (HEU) solution (SOL) thermal spectrum (THERM) systems, through the analysis of the 10 cases from HEU-SOL-THERM-001 from the IHECSBE.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Neutron and Gamma Dose in the Irradiation Cell of Texas A and M University Research Reactor

The Monte Carlo N-Particle (MCNP) code was used to develop a three dimensional computational model of the Texas A and M University Nuclear Science Center Reactor (NSCR) operating against the irradiation (dry cell) at steady state thermal power of 1 MW. The geometry of the NSCR core and the dry cell were modeled in detail. NSCR is used for a wide variety of experiments that utilizes the dry cell for neutron as well as gamma irradiation of samples. Information on the neutron and gamma radiation environment inside the dry cell is required to facilitate irradiation of samples. This paper presents the computed neutron flux, neutron and gamma dose rate, and foil reaction rates in the dry cell, obtained through MCNP5 simulations of the NSCR core. The neutron flux was measured using foil activation method and the reaction rates obtained from {sup 197}Au(n,{gamma}){sup 198}Au and {sup 54}Fe(n,p){sup 54}Mn were compared with the model and they showed agreement within {approx} 20%. The gamma dose rate at selected locations inside the dry cell was measured using radiochromic films and the results indicate slightly higher dose rates than predicted from the model. This is because the model calculated only prompt gamma dose rates during reactor operation while the radiochromic films measured gammas from activation products and fission product decayed gammas. The model was also used to calculate the neutron energy spectra for the energy range from 0.001 eV- 20 MeV. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗