Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

SHM of wind turbine blades using piezoelectric active-sensors

This paper presents a variety of structural health monitoring (SHM) techniques, based on the use of piezoelectric active-sensors, used to determine the structural integrity of wind turbine blades. Specifically, Lamb wave propagations, frequency response functions, and time series based methods are utilized to estimate the condition of wind turbine blades. For experiments, a 1m section of a 9m CX100 blade is used. Overall, these three methods yielded a sufficient damage detection capability to warrant further investigation into field deployment. A full-scale fatigue test of a CX-100 wind turbine blade is also conducted. This paper summarizes considerations needed to design such SHM systems, experimental procedures and results, and practical implementation issues that can be used as guidelines for future investigations.

17 WIND ENERGY↗

Development of in situ thickness sensor for vapor diffused Nb3Sn films

Fermilab is one of the leaders in development of vapor diffused Nb3Sn films inside niobium cavities. This material has a higher critical temperature (Tc) than niobium, enabling cavity operation at 4.2 K. This higher operational temperature significantly reduces the infrastructure required for cooling compared to 2 K systems, making superconducting radio-frequency (SRF) technology more accessible. Current deposition methods have relied on iterative testing to determine nominal film thickness, a process that can be time-consuming and imprecise. To address this, we are developing a sensor to measure the thickness of Nb3Sn thin film in situ during vapor diffusion. Our design involves the resistance measurement of a thin film of niobium. During coating, the change in resistance reflects the conversion of the film to Nb3Sn, which allows simple integration with the current furnace infrastructure. This sensor would allow real time measurement of the thickness, allowing for increased precision in future depositions.

Howard, K. [Unlisted] (ORCID:0000000325613308)↗

High-density Schottky barrier IRCCD sensors for remote sensing applications

It is pointed out that the ambitious goals envisaged for the next generation of space-borne sensors challenge the state-of-the-art in solid-state imaging technology. Studies are being conducted with the aim to provide focal plane array technology suitable for use in future Multispectral Linear Array (MLA) earth resource instruments. An important new technology for IR-image sensors involves the use of monolithic Schottky barrier infrared charge-coupled device arrays. This technology is suitable for earth sensing applications in which moderate quantum efficiency and intermediate operating temperatures are required. This IR sensor can be fabricated by using standard integrated circuit (IC) processing techniques, and it is possible to employ commercial IC grade silicon. For this reason, it is feasible to construct Schottky barrier area and line arrays with large numbers of elements and high-density designs. A Pd2Si Schottky barrier sensor for multispectral imaging in the 1 to 3.5 micron band is under development.

Elabd, H.↗

Field intercomparison of a novel optical sensor for formaldehyde quantification

A one-week in situ intercomparison campaign was completed on the Rice University campus for measuring HCHO using three different techniques, including a novel optical sensor based on difference frequency generation (DFG) operating at room temperature. Two chemical derivatization methods, 2,4-dinitrophenylhydrazine (DNPH) and o-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA), were deployed during the daylight hours for three- to four-hour time-integrated samples. A real-time optical sensor based on laser absorption spectroscopy was operated simultaneously, including nighttime hours. This tunable spectroscopic source based on difference frequency mixing of two fiber-amplified diode lasers in periodically poled LiNb03 (PPLN) was operated at 3.5315 micrometers (2831.64 cm 1) to access a strong HCHO ro-vibrational transition free of interferences from other species. The results showed a bias of -1.7 and -1.2 ppbv and a gross error of 2.6 and 1.5 ppbv for DNPH and PFBHA measurements, respectively, compared with DFG measurements. These results validate the DFG sensor for time-resolved measurements of HCHO in urban areas.

NASA Discipline Life Sciences Technologies↗

An evaluation of EREP (Skylab) and ERTS imagery for integrated natural resources survey

The author has identified the following significant results. An experimental procedure has been devised and is being tested for natural resource surveys to cope with the problems of interpreting and processing the large quantities of data provided by Skylab and ERTS. Some basic aspects of orbital imagery such as scale, the role of repetitive coverage, and types of sensors are being examined in relation to integrated surveys of natural resources and regional development planning. Extrapolation away from known ground conditions, a fundamental technique for mapping resources, becomes very effective when used on orbital imagery supported by field mapping. Meaningful boundary delimitations can be made on orbital images using various image enhancement techniques. To meet the needs of many developing countries, this investigation into the use of satellite imagery for integrated resource surveys involves the analysis of the images by means of standard visual photointerpretation methods.

Vangenderen, J. L.↗

Nanosensors-Cellphone Integration for Extended Chemical Sensing Network

This poster is to present the development of a cellphone sensor network for extended chemical sensing. The nanosensors using carbon nanotubes and other nanostructures are used with low power and high sensitivity for chemical detection. The sensing module has been miniaturized to a small size that can plug in or clip on to a smartphone. The chemical information detected by the nanosensors are acquired by a smartphone and transmitted via cellphone 3g or WiFi network to an internet server. The whole integrated sensing system from sensor to cellphone to a cloud will provide an extended chemical sensing network that can cover nation wide and even cover global wide for early warning of a hazardous event.

Li, Jing↗

An investigation for the development of an integrated optical data preprocessor

The successful fabrication and demonstration of an integrated optical circuit designed to perform a parallel processing operation by utilizing holographic subtraction to simultaneously compare N analog signal voltages with N predetermined reference voltages is summarized. The device alleviates transmission, storage and processing loads of satellite data systems by performing, at the sensor site, some preprocessing of data taken by remote sensors. Major accomplishments in the fabrication of integrated optics components include: (1) fabrication of the first LiNbO3 waveguide geodesic lens; (2) development of techniques for polishing TIR mirrors on LiNbO3 waveguides; (3) fabrication of high efficiency metal-over-photoresist gratings for waveguide beam splitters; (4) demonstration of high S/N holographic subtraction using waveguide holograms; and (5) development of alignment techniques for fabrication of integrated optics circuits. Important developments made in integrated optics are the discovery and suggested use of holographic self-subtraction in LiNbO3, development of a mathematical description of the operating modes of the preprocessor, and the development of theories for diffraction efficiency and beam quality of two dimensional beam defined gratings.

Verber, C. M.↗

Integrated-optical approaches to matrix multiplication

The solution of matrix equations is essential to carrying out a large variety of control algorithms and to reducing certain types of data such as the output of a multispectral sensor array. Optical techniques and, in particular, integrated-optical circuits (IOC's) can provide compact, low-power devices for performing the mitrix multiplications necessary for the solution of these problems. A specific IOC for performing vector-matrix multiplication and several approaches to the design of IOC's for matrix-matrix multiplication will be discussed.

Verber, C. M.↗

A Single Chip CMOS APS Digital Camera

A complete programmable digital camera-on-a-chip based on low power active pixel sensor technology is implemented as a single CMOS integrated circuit.

imaging sensor camera-on-a-chip digital camera↗

NASA Tech Briefs, November 2011

The topics include: 1) Flight Test Results from the Rake Airflow Gage Experiment on the F-15B; 2) Telemetry and Science Data Software System; 3) CropEx Web-Based Agricultural Monitoring and Decision Support; 4) High-Performance Data Analysis Tools for Sun-Earth Connection Missions; 5) Experiment in Onboard Synthetic Aperture Radar Data Processing; 6) Microfabrication of a High-Throughput Nanochannel Delivery/Filtration System; 7) Improved Design and Fabrication of Hydrated-Salt Pills; 8) Monolithic Flexure Pre-Stressed Ultrasonic Horns; 9) Cryogenic Quenching Process for Electronic Part Screening; 10) Broadband Via-Less Microwave Crossover Using Microstrip-CPW Transitions; 11) Wheel-Based Ice Sensors for Road Vehicles; 12) G-DYN Multibody Dynamics Engine; 13) Multibody Simulation Software Testbed for Small-Body Exploration and Sampling; 14) Propulsive Reaction Control System Model; 15) Licklider Transmission Protocol Implementation; 16) Core Recursive Hierarchical Image Segmentation; 17) Two-Stage Centrifugal Fan; 18) Combined Structural and Trajectory Control of Variable-Geometry Planetary Entry Systems; 19) Pressure Regulator With Internal Ejector Circulation Pump, Flow and Pressure Measurement Porting, and Fuel Cell System Integration Options; 20) Temperature-Sensitive Coating Sensor Based on Hematite; 21) Standardization of a Volumetric Displacement Measurement for Two-Body Abrasion Scratch Test Data Analysis; 22) Detection of Carbon Monoxide Using Polymer-Carbon Composite Films; 23) Substituted Quaternary Ammonium Salts Improve Low-Temperature Performance of Double-Layer Capacitors; 24) Sustainably Sourced, Thermally Resistant, Radiation Hard Biopolymer; 25) Integrated Lens Antennas for Multi-Pixel Receivers; 26) 180-GHz Interferometric Imager; 27) Maturation of Structural Health Management Systems for Solid Rocket Motors; 28) Validating Phasing and Geometry of Large Focal Plane Arrays; 29) Transverse Pupil Shifts for Adaptive Optics Non-Common Path Calibration; 30) Qualification of Fiber Optic Cables for Martian Extreme Temperature Environments; 31) Solid-State Spectral Light Source System; 32) Multiple-Event, Single-Photon Counting Imaging Sensor; 33) Surface Modeling to Support Small-Body Spacecraft Exploration and Proximity Operations; and 34) Achieving Exact and Constant Turnaround Ratio in a DDS-Based Coherent Transponder.

Source record↗

The responses of rising or falling spherical wind sensors to atmospheric wind perturbations.

Analysis of the responses of rising or falling spherical wind sensors to atmospheric wind perturbations on the wind profile in the vertical, using Fourier transform techniques. The linearized equations of motion of a sensor that is subject to drag and gravitational body forces are developed by perturbing a sensor about an equilibrium uniform motion with wind fluctuations which have vertical variations. The wind environment and sensor velocities are decomposed with stochastic Fourier-Stieltjes integrals, and the linearized equations of motion are used to derive the response functions and phase angles of the sensor motions. The results of the analysis are used to analyze the response properties of the Jimsphere balloon wind sensor. It is shown that, in general, the transfer functions associated with the horizontal sensor motions are smaller than the transfer functions associated with the vertical sensor motions in the omega times T product range from zero to infinity, omega being the wind perturbation frequency and T a time constant of the system. Thus, the sensor is more responsive to vertical than to horizontal air motions.

Fichtl, G. H.↗

A Multi-Sensor Approach To Estimation of Tropospheric Delays

We will discuss techniques for optima1 integration of atmospheric measurements from collocated GPS receiver, pointed WVR, and a barometer, capitalizing on the unique strength of each sensor, and minimizing the impact of the sensor's weaknesses. The goal is to improve our ability to estimate line of sight (LOS) total atmospheric delay, which is required in support of certain high precision applications, such as radio science, and deep space navigation. The benefits from improved atmospheric sensing extend to many other applications such as geodesy and time transfer.

optical integration↗

MAC Europe 1991 campaign: AIRSAR/AVIRIS data integration for agricultural test site classification

During summer 1991, multi-sensor data were acquired over the Italian test site 'Otrepo Pavese', an agricultural flat area in Northern Italy. This area has been the Telespazio pilot test site for experimental activities related to agriculture applications. The aim of the investigation described in the following paper is to assess the amount of information contained in the AIRSAR (Airborne Synthetic Aperture Radar) and AVIRIS (Airborne Visible/Infrared Imaging Spectrometer) data, and to evaluate classification results obtained from each sensor data separately and from the combined dataset. All classifications are examined by means of the resulting confusion matrices and Khat coefficients. Improvements of the classification results obtained by using the integrated dataset are finally evaluated.

Sangiovanni, S.↗

Development of in situ thickness sensor for vapor diffused Nb3Sn films

Fermilab is one of the leaders in development of vapor diffused Nb3Sn films inside niobium cavities. This material has a higher critical temperature (Tc) than niobium, enabling cavity operation at 4.2 K. This higher operational temperature significantly reduces the infrastructure required for cooling compared to 2 K systems, making superconducting radio-frequency (SRF) technology more accessible. Current deposition methods have relied on iterative testing to determine nominal film thickness, a process that can be time-consuming and imprecise. To address this, we are developing a sensor to measure the thickness of Nb3Sn thin film in situ during vapor diffusion. Our design involves a four-point resistance measurement of a thin film of niobium, inside the coating region. During coating, the change in resistance reflects the conversion of the film from Nb to Nb3Sn, which allows simple integration with the current furnace infrastructure. This sensor would allow real time measurement of the Nb3Sn film thickness, allowing for increased precision in future depositions for cavity applications.

Howard, K. [Chicago U.] (ORCID:0000000325613308)↗

Blockchain Empowered Provenance Framework for Sensor Identity Management and Data Flow Security in Fossil-based Power Plants

The overall goals of this project are divided into 3 important phases. First, a peer-to-peer SCADA network is to be established where identity profile of sensors from fossil-power plants will be stored in an immutable manner in order to verify data flow integrity in real time. Second, it is aimed to develop a Blockchain-based provenance platform to audit equipment operations along with data and process integrity violations. In this phase, various operational rules will be incorporated in the ledger on behalf of the operating sensor so its abnormal use can be easily detected. In addition, it is aimed to achieve provenance when the rate of transactions is exceedingly high, thus enabling to design a scalable provenance scheme that can work in real time when number of data collecting points or sensor units increase in fossil-based power plants. Finally, a working testbed will be developed to integrate the Blockchain platform with sensor-based fossil power plant comprising of Remote Terminal Units (RTU) and SCADA devices. Using multiple Raspberry-PIs mimicking the role of RTUs that are interfaced with multiple sensors devices will be deployed to serve as a critical component of fossil power plant and the performance metrics such as throughput, latency, bootstrapping time, etc., will be evaluated on the testbed.

20 FOSSIL-FUELED POWER PLANTS↗

Testing, Calibration, and UxS Integration of the Kromek GR1 Plus CZT Gamma Spectrometer

Collecting radiation measurements can be a hazardous task, especially in the presence of highly active sources. Various scenarios necessitate source search, classification, and quantification, often with limited or no a priori information. Activities such as disaster mitigation, emergency response, environmental monitoring, and site remediation may involve dangerous radioactive sources. In these situations, there is a pressing need for remote monitoring capabilities that protect human operators from potential harm and enhance adherence to the principle of “As Low as Reasonably Achievable” (ALARA) for radiation doses. The first step toward achieving remote radiation measurement capabilities is the remote operation of a radiation sensor. Once this milestone is reached, the next challenge is to integrate this remote sensing capability into suitable actuation agents, collectively referred to as uncrewed systems (UxS). These systems include familiar platforms such as robotic quadrupeds, aerial multirotor vehicles, and ground vehicles, any of which may be teleoperated, act autonomously, or utilize a combination of both. A critical factor in achieving remote radiation sensing is the availability of data from the appropriate sensor. Many commercially available radiation sensors have closed-source documentation for their communication protocols. Typical end-user products are often self-contained, handheld devices designed for manual measurement scenarios. While there are commercial off-the-shelf (COTS) integrations of radiation sensors with UxS available for purchase, these solutions are typically tailored for specific use cases and may not meet the requirements of different applications. This paper discusses efforts to remotely acquire radiation measurements from a small form-factor CZT gamma spectrometer. Sandia National Laboratories has successfully demonstrated the initial capability to integrate low size, weight, and power (SWaP) gamma spectroscopy into various UxS, alongside co-located GPS data logging and sensor calibration and qualification. With remote gamma spectroscopy achieved, the stage is set for UxS integration of this capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparisons of Artemis I and Wind Tunnel Buffet Environments and Induced Structural Responses

This paper presents comparisons of buffet forcing functions (BFFs) and associated structural responses for the Space Launch System from two data sources: 1) Artemis I (AR01) Developmental Flight Instrumentation (DFI) and 2) transonic wind-tunnel (WT) tests. Failures of DFI sensors prevented the development of a complete set of flight-based BFFs, where each BFF is based on azimuthal integration over 360-degrees of unsteady pressures acquired by sensor rings placed at many longitudinal stations along the vehicle. Instead, a set of equivalent flight- and WT-based BFFs was developed based on functional DFI and WT sensors that share the same locations. Root-mean-square (rms) levels of equivalent BFFs from flight and WT data are in-family for most of the cardinal Mach numbers. However, at stations downstream of the booster forward attachment (FA) protuberance, the rms of flight-based BFFs exceed their WT counterparts. Strikingly, vortex-shedding off the FA protuberance occurs at lower frequencies during flight than in WT experiments. This frequency shift propagates onto the spectrum of flight-measured vs. WT-based structural responses. Aside from vortex-shedding frequency mismatch, a generally good agreement between AR01 and WT-based responses is an indirect indication that WT buffet environments are fairly well representative of their AR01 counterpart.

transonic buffet↗