Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

New Insights to the Sawtooth Oscillation (m/n=1/1 mode) in Hot Plasmas based on High Resolution 2-D Images of Te Fluctuations

Two dimensional (2-D) images of electron temperature fluctuations with high temporal and spatial resolution have been employed to study the sawtooth oscillation (m/n=1/1 mode) in Toroidal EXperiment for Technology Oriented Research (TEXTOR) tokamak plasmas. 2-D imaging data revealed new physics which were not available in previous studies based on the 1-D electron temperature measurement and X-ray tomography. Review of the physics of the sawtooth oscillation is given by comparative studies with prominent theoretical models suggest that a new physics paradigm is needed to describe the reconnection physics of the sawtooth oscillation. The new insights are: A pressure driven instability (not a ballooning mode) leads to the X-point reconnection process. The reconnection process is identified as a random 3-D local reconnection process with a helical structure. The reconnection time scale is similar for different types of sawtooth oscillation ("kink" and tearing type) and is significantly faster than the resistive time scale. Heat flow from the core to the outside of the inversion radius during the reconnection process is highly collective rather than stochastic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intermediate frequency band digitized high dynamic range radiometer system for plasma diagnostics and real-time Tokamak control

An intermediate frequency (IF) band digitizing radiometer system in the 100-200 GHz frequency range has been developed for Tokamak diagnostics and control, and other fields of research which require a high flexibility in frequency resolution combined with a large bandwidth and the retrieval of the full wave information of the mm-wave signals under investigation. The system is based on directly digitizing the IF band after down conversion. The enabling technology consists of a fast multi-giga sample analog to digital converter that has recently become available. Field programmable gate arrays (FPGA) are implemented to accomplish versatile real-time data analysis. A prototype system has been developed and tested and its performance has been compared with conventional electron cyclotron emission (ECE) spectrometer systems. On the TEXTOR Tokamak a proof of principle shows that ECE, together with high power injected and scattered radiation, becomes amenable to measurement by this device. In particular, its capability to measure the phase of coherent signals in the spectrum offers important advantages in diagnostics and control. One case developed in detail employs the FPGA in real-time fast Fourier transform (FFT) and additional signal processing. The major benefit of such a FFT-based system is the real-time trade-off that can be made between frequency and time resolution. For ECE diagnostics this corresponds to a flexible spatial resolution in the plasma, with potential application in smart sensing of plasma instabilities such as the neoclassical tearing mode (NTM) and sawtooth instabilities. The flexible resolution would allow for the measurement of the full mode content of plasma instabilities contained within the system bandwidth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micro- and nano-imaging at the diamond beamline I13L-imaging and coherence

The Diamond Beamline I13L is dedicated to imaging on the micron- and nano-lengthscale, operating in the energy range between 6 and 30 keV. For this purpose two independent stations have been built. The imaging branch is fully operational for micro-tomography and in-line phase contrast imaging with micrometer resolution. Currently a full-field microscope providing 50nm spatial resolution over a field of view of 100 µm is being tested. On the coherence branch, coherent diffraction imaging techniques such as ptychography and coherent X-ray Bragg diffraction are currently developed. The beamline contains a number of unique features. The machine layout has been modified to the so-called mini-beta scheme, providing significantly increased flux from the two canted undulators. New instrumental designs such as a robot arm for the detector in diffraction experiments have been employed. The imaging branch is operated in collaboration with Manchester University, called therefore the Diamond-Manchester Branchline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space-resolved extreme ultraviolet spectrometer for impurity emission profile measurement in Large Helical Device

A space-resolved extreme ultraviolet (EUV) spectrometer working in 60-400 A range has been developed to observe impurity emission profiles in core and edge plasmas of Large Helical Device (LHD). A flat focus is made for plane surface detector by using a varied line spacing holographic grating with an angle of incidence of 87 deg. An excellent spectral resolution of 0.22 A at 200 A is then obtained after careful adjustment of the optical components. In the profile measurement of the LHD plasmas, the toroidal resolution is important as well as the radial resolution because the magnetic surfaces of LHD quickly change when the observation chord is tilted at a slightly different toroidal location. Horizontal dispersion is therefore selected for the present spectrometer. As a result, the toroidal resolution of 75 mm is achieved at the plasma position. An enough radial resolution of 10 mm is also obtained at spatial-resolution slit width of 0.2 mm. In order to measure the full radial profile of LHD plasmas the spectrometer is placed at a distance of {approx}9200 mm away from the plasma center and a backilluminated charge-coupled device with a size of 6.6x26.6 mm{sup 2} is set vertical to the horizontal dispersion. Half of the LHD plasma, i.e., {approx}50 cm, can be measured along the vertical direction at horizontally elongated plasma cross section. A full vertical profile can be obtained by changing the vertical angle of the EUV spectrometer. As an example the full vertical profile of edge C IV (312.4 A) emission is presented. A wavelength interval of 35-65 A can be simultaneously observed, which varies according to the wavelength to be measured. A local emission profile of Fe XX (132.67 A) is also presented after Abel inversion as a typical example of the core EUV emission. Finally, the EUV spectrometer is absolutely calibrated using EUV bremsstrahlung continuum profile in comparison with absolute values of visible bremsstrahlung continuum profile because the bremsstrahlung continuum can be easily detected in high-density discharges of LHD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ABUNDANT CH{sub 3}OH MASERS BUT NO NEW EVIDENCE FOR STAR FORMATION IN GCM0.253+0.016

We present new observations of the quiescent giant molecular cloud GCM0.253+0.016 in the Galactic center, using the upgraded Karl G. Jansky Very Large Array. Observations were made at wavelengths near 1 cm, at the K (24–26 GHz) and Ka (27 and 36 GHz) bands, with velocity resolutions of 1–3 km s{sup −1} and spatial resolutions of ∼0.1 pc, at the assumed 8.4 kpc distance of this cloud. The continuum observations of this cloud are the most sensitive yet made, and reveal previously undetected emission which we attribute primarily to free–free emission from external ionization of the cloud. In addition to the sensitive continuum map, we produce maps of 12 molecular lines: 8 transitions of NH{sub 3}–(1, 1), (2, 2), (3, 3), (4, 4), (5, 5), (6, 6), (7, 7), and (9, 9), as well as the HC{sub 3}N (3–2) and (4–3) lines, and CH{sub 3}OH 4{sub −1}–3{sub 0}, the latter of which is known to be a collisionally excited maser. We identify 148 CH{sub 3}OH 4{sub −1}–3{sub 0} (36.2 GHz) sources, of which 68 have brightness temperatures in excess of the highest temperature measured for this cloud (400 K) and can be confirmed to be masers. The majority of these masers are concentrated in the southernmost part of the cloud. We find that neither these masers nor the continuum emission in this cloud provide strong evidence for ongoing star formation in excess of that previously inferred by the presence of an H{sub 2}O maser.

79 ASTRONOMY AND ASTROPHYSICS↗

An ammonia spectral map of the L1495-B218 filaments in the Taurus molecular cloud. I. Physical properties of filaments and dense cores

We present deep NH{sub 3} observations of the L1495-B218 filaments in the Taurus molecular cloud covering over a 3° angular range using the K-band focal plane array on the 100 m Green Bank Telescope. The L1495-B218 filaments form an interconnected, nearby, large complex extending over 8 pc. We observed NH{sub 3} (1, 1) and (2, 2) with a spectral resolution of 0.038 km s{sup −1} and a spatial resolution of 31″. Most of the ammonia peaks coincide with intensity peaks in dust continuum maps at 350 and 500 μm. We deduced physical properties by fitting a model to the observed spectra. We find gas kinetic temperatures of 8–15 K, velocity dispersions of 0.05–0.25 km s{sup −1}, and NH{sub 3} column densities of 5 × 10{sup 12} to 1 × 10{sup 14} cm{sup −2}. The CSAR algorithm, which is a hybrid of seeded-watershed and binary dendrogram algorithms, identifies a total of 55 NH{sub 3} structures, including 39 leaves and 16 branches. The masses of the NH{sub 3} sources range from 0.05 to 9.5 M{sub ⊙}. The masses of NH{sub 3} leaves are mostly smaller than their corresponding virial mass estimated from their internal and gravitational energies, which suggests that these leaves are gravitationally unbound structures. Nine out of 39 NH{sub 3} leaves are gravitationally bound, and seven out of nine gravitationally bound NH{sub 3} leaves are associated with star formation. We also found that 12 out of 30 gravitationally unbound leaves are pressure confined. Our data suggest that a dense core may form as a pressure-confined structure, evolve to a gravitationally bound core, and undergo collapse to form a protostar.

79 ASTRONOMY AND ASTROPHYSICS↗

Hard x-ray nanobeam characterization by coherent diffraction microscopy

We have carried out a ptychographic scanning coherent diffraction imaging experiment on a test object in order to characterize the hard x-ray nanobeam in a scanning x-ray microscope. In addition to a high resolution image of the test object, a detailed quantitative picture of the complex wave field in the nanofocus is obtained with high spatial resolution and dynamic range. Both are the result of high statistics due to the large number of diffraction patterns. The method yields a complete description of the focus, is robust against inaccuracies in sample positioning, and requires no particular shape or prior knowledge of the test object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast x-ray microdiffraction techniques for studying irreversible transformations in materials.

A pair of techniques have been developed for performing time-resolved X-ray microdiffraction on irreversible phase transformations. In one technique capillary optics are used to focus a high-flux broad-spectrum X-ray beam to a 60 {micro}m spot size and a fast pixel array detector is used to achieve temporal resolution of 55 {micro}s. In the second technique the X-rays are focused with Kirkpatrick-Baez mirrors to achieve a spatial resolution better than 10 {micro}m and a fast shutter is used to provide temporal resolution better than 20 {micro}s while recording the diffraction pattern on a (relatively slow) X-ray CCD camera. Example data from experiments are presented where these techniques are used to study self-propagating high-temperature synthesis reactions in metal laminate foils.

43 PARTICLE ACCELERATORS↗

Daily, 30 m Resolution NDSI Data for the East River Watershed, CO for 2000-2020

This dataset contains daily Normalized Difference Snow Index (NDSI) values at 30 m spatial resolution for the East River watershed in Colorado, USA. The temporal range of these data includes water years 2001-2020. These data were created using the Spatial and Temporal Adaptive Reflectance Fusion Model (STARFM). This model fuses low spatial and high temporal resolution data from MODIS (500 m, daily) with high spatial and low temporal resolution data from Landsat (30 m, 16 days) to create a 30m synthetic daily snow product. This product allows for the analysis of historical snow covered area trends in the East River Watershed at fine spatiotemporal resolutions where it was not available previously. This research was performed as a part of the Department of Energy’s Subsurface Biogeochemical Research Program with the primary intent of better understanding the timing and spatial patterns of water delivery to the Critical Zone in mountain watersheds. Each .zip file contains one "water year" of data (October 1 - September 30; i.e., water year 2010 starts October 1, 2010 and ends September 30, 2011). Each zip file contains the following: STARFM daily Normalized Difference Snow Index (NDSI) fusion data files in GeoTiff format with one layer for each day between Landsat data acquisition dates (i.e., for dates of Landsat acquisition, the Landsat image is included for that date). The study area is located in an area of Landsat path overlap, so Landsat dates acquisitions are every 7-9 days. Landsat NDSI files containing the high spatial (30m), low temporal (7-9 days due to Landsat path overlap) resolution data used as input to STARFM in GeoTiff format with one layer for each day. Dates for which no Landsat data were obtained are included as NoData layers. MODIS NDSI files containing the high temporal (daily), low spatial (500m) resolution data used as input to STARFM in GeoTiff format with one layer for each day. Please note the MODIS data were resampled to 30m pixels for input into the STARFM model. The data have a scale factor of 10,000 and a no data value of -32767. The projection of all datasets is WGS 84 (EPSG: 4326), which has a latitude/longitude based degree resolution of 0.0002694946 X 0.0002694946, and approximates to the 30 m spatial resolution mentioned above. The Layer Index files in .csv format. They contain information for each layer in the above GeoTiff files regarding the corresponding date for each layer, the fraction of pixels in the image that contain valid data (missing data is due to either cloud cover or poor data quality; these values are not percent snow cover). Dates of Landsat overpass are indicated in these files. If no Landsat data were able to be obtained due to cloud cover or lack of Landsat Tier 1 data available on Google Earth Engine, this is also noted.

EARTH SCIENCE > CRYOSPHERE > SNOW/ICE↗

Low-Altitude Unmanned Aerial Vehicles as a Tool for the Remediation of Radiologically Contaminated Environments - 16257

Following the events at the Fukushima Daiichi Nuclear Power Plant (FDNPP) in March 2011, significant quantities of radioactive material were released into the local Japanese as well as the wider global environment. At the fifth anniversary of the incident, much work and expense is still being dedicated to the remediation of a large area of eastern Japan, contaminated primarily with radio-caesium. Due to the complex topography of the geographical area of Japan effected, it is important to understand contaminant evolution/migration at the greatest possible resolution - previous methods have lacked this. An increase in the spatial resolution of radiation mapping over other previous methods has been achieved through the deployment of an unmanned aerial vehicle (UAV). The platform used during this work combined a low-altitude multi-rotor UAV with a lightweight radiation mapping system to achieve sub-meter resolution. Using this system it was possible to measure the distribution of radionuclide contamination at a number of sites within the Fukushima Prefecture region of Japan. Unlike ground-based surveys conducted on foot by humans that attain a comparable resolution, such a system eliminates the potentially significant dose that would otherwise be received, as well as the influence of shielding on results. In addition to providing a rapid and high resolution response to radiological incidents, such monitoring technology has the potential to be a powerful tool in post-operational clean-out (POCO) at nuclear sites undergoing decommissioning worldwide. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Super-resolution quantum interference pattern of a distributed object

Classically, the spatial resolution of the image of an object is usually determined by the Rayleigh criterion. However, quantum properties of light have been exploited to form images with resolutions exceeding this criterion and beating the standard quantum limit, which allow high measurement sensitivity. We found that it is possible to super-resolve a distributed object made of two parts that are spatially separated but when superposed over each other form an object. A coincidence interference pattern of a nonlocal two-photon system with periodicity proportional to {lambda}/2 was measured even when each photon, with wavelength of {lambda}, has been scattered by different parts of an object, none of them being the object itself.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SOLAR CYCLE VARIATION OF THE INTER-NETWORK MAGNETIC FIELD

The solar inter-network magnetic field is the weakest component of solar magnetism, but it contributes most of the solar surface magnetic flux. The study of its origin has been constrained by the inadequate tempospatial resolution and sensitivity of polarization observations. With dramatic advances in spatial resolution and detecting sensitivity, the solar spectropolarimetry provided by the Solar Optical Telescope on board Hinode in an interval from the solar minimum to maximum of cycle 24 opens an unprecedented opportunity to study the cyclic behavior of the solar inter-network magnetic field. More than 1000 Hinode magnetograms observed from 2007 January to 2014 August are selected in the study. It has been found that there is a very slight correlation between sunspot number and magnetic field at the inter-network flux spectrum. From solar minimum to maximum of cycle 24, the flux density of the solar inter-network field is invariant, at 10 ± 1 G. The observations suggest that the inter-network magnetic field does not arise from flux diffusion or flux recycling of solar active regions, thereby indicating the existence of a local small-scale dynamo. Combining the full-disk magnetograms observed by the Solar and Heliospheric Observatory/Michelson Doppler Imager and the Solar Dynamics Observatory/Helioseismic and Magnetic Imager in the same period, we find that the area ratio of the inter-network region to the full disk of the Sun apparently decreases from solar minimum to maximum but always exceeds 60%, even in the phase of solar maximum.

79 ASTRONOMY AND ASTROPHYSICS↗

Hard x-ray response of pixellated CdZnTe detectors

In recent years, the development of cadmium zinc telluride (CdZnTe) detectors for x-ray and gamma ray spectrometry has grown rapidly. The good room temperature performance and the high spatial resolution of pixellated CdZnTe detectors make them very attractive in space-borne x-ray astronomy, mainly as focal plane detectors for the new generation of hard x-ray focusing telescopes. In this work, we investigated on the spectroscopic performance of two pixellated CdZnTe detectors coupled with a custom low noise and low power readout application specific integrated circuit (ASIC). The detectors (10x10x1 and 10x10x2 mm{sup 3} single crystals) have an anode layout based on an array of 256 pixels with a geometric pitch of 0.5 mm. The ASIC, fabricated in 0.8 mum BiCMOS technology, is equipped with eight independent channels (preamplifier and shaper) and characterized by low power consumption (0.5 mW/channel) and low noise (150-500 electrons rms). The spectroscopic results point out the good energy resolution of both detectors at room temperature [5.8% full width at half maximum (FWHM) at 59.5 keV for the 1 mm thick detector; 5.5% FWHM at 59.5 keV for the 2 mm thick detector) and low tailing in the measured spectra, confirming the single charge carrier sensing properties of the CdZnTe detectors equipped with a pixellated anode layout. Temperature measurements show optimum performance of the system (detector and electronics) at T=10 deg.C and performance degradation at lower temperatures. The detectors and the ASIC were developed by our collaboration as two small focal plane detector prototypes for hard x-ray multilayer telescopes operating in the 20-70 keV energy range.

36 MATERIALS SCIENCE↗

Electron cyclotron emission diagnostic for ITER

Electron temperature measurements and electron thermal transport inferences will be critical to the nonactive and deuterium phases of ITER operation and will take on added importance during the alpha heating phase. The diagnostic must meet stringent criteria on spatial coverage and spatial resolution during full field operation. During the early phases of operation, it must operate equally well at half field. The key to the diagnostic is the front end design. It consists of a quasioptical antenna and a pair of calibration sources. The radial resolution of the diagnostic is less than 0.06 m. The spatial coverage extends at least from the core to the separatrix with first harmonic O-mode being used for the core and second harmonic X-mode being used for the pedestal. The instrumentation used for the core measurement at full field can be used for detection at half field by changing the detected polarization. Intermediate fields are accessible. The electron cyclotron emission systems require in situ calibration, which is provided by a novel hot calibration source. The critical component for the hot calibration source, the emissive surface, has been successfully tested. A prototype hot calibration source has been designed, making use of extensive thermal and mechanical modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Negative Ions for Emerging Interdisciplinary Applications

In many applications related to ion beam-materials interactions negative ions are particularly desirable due to its merit to yield a very low surface charge-up voltage, {approx} a few volts, for both electrically isolated surfaces and insulators. Some important applications pertaining to ion beam-material interactions include surface analysis by secondary ion mass spectrometry (SIMS), voltage-contrast microscopy for semiconductor device inspection, materials processing, and ion beam lithography. These applications primarily require vacuum environments. On the other hand, a distinct area of activities constitutes formation of ions and ion transport in ambient environmental conditions, i.e., at atmospheric pressures. In this context, ion mobility spectrometry (IMS) is an important analytical device that uses negative ions and operates at ambient conditions. IMS is widely used in both physical and biological sciences including monitoring environmental conditions, security screening and disease detection. This article highlights several critical issues related to the ionization sources and ion transport in IMS. Additionally, the critical issues related to ion sources, transport and focusing are discussed in the context of SIMS with sub-micrometer spatial resolution.

36 MATERIALS SCIENCE↗

High speed automated microtomography of nuclear emulsions and recent application

The development of high-speed automatic scanning systems was the key-factor for massive and successful emulsions application for big neutrino experiments like OPERA. The emulsion detector simplicity, the unprecedented sub-micron spatial resolution and the unique ability to provide intrinsically 3-dimensional spatial information make it a perfect device for short-living particles study, where the event topology should be precisely reconstructed in a 10-100 um scale vertex region. Recently the exceptional technological progress in image processing and automation together with intensive R&D done by Italian and Japanese microscopy groups permit to increase the scanning speed to unbelievable few years ago m{sup 2}/day scale and so greatly extend the range of the possible applications for emulsion-based detectors to other fields like: medical imaging, directional dark matter search, nuclear physics, geological and industrial applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic ultramicroscopy of laser-induced flows in colloidal solutions of plasmon-resonance particles

A method is proposed for visualisation of the velocity fields of colloidal plasmon-resonance nanoparticles moving in a laser beam. The method uses the particle image velocimetry for processing ultramicroscopic images. Particles in a thick layer of colloidal solution are illuminated by a slit laser ultramicroscopic source with a large numerical aperture providing a high contrast of particle images and visualisation of the transverse velocity distribution in laser-induced flows with a high spatial resolution. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fibreoptic distributed temperature sensor with spectral filtration by directional fibre couplers

We demonstrate a Raman-based all-fibre temperature sensor utilising a pulsed erbium fibre laser. The sensor is made of a standard single-mode telecom fibre, SMF-28, and includes a number of directional couplers as band-pass filters. The temperature profile along a 7-km fibreoptic line is measured with an accuracy of 2{sup o}C and a spatial resolution of 10 m. In data processing, we take into account the difference in attenuation between the spectral components of the backscatter signal. (optical fibres and fibreoptic sensors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗