Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Upper critical solution temperature polymer assemblies via variable temperature liquid phase transmission electron microscopy and liquid resonant soft X-ray scattering

Abstract Here, we study the upper critical solution temperature triggered phase transition of thermally responsive poly(ethylene glycol)- block -poly(ethylene glycol) methyl ether acrylate- co -poly(ethylene glycol) phenyl ether acrylate- block -polystyrene nanoassemblies in isopropanol. To gain mechanistic insight into the organic solution-phase dynamics of the upper critical solution temperature polymer, we leverage variable temperature liquid-cell transmission electron microscopy correlated with variable temperature liquid resonant soft X-ray scattering. Heating above the upper critical solution temperature triggers a reduction in particle size and a morphological transition from a spherical core shell particle with a complex, multiphase core to a micelle with a uniform core and Gaussian polymer chains attached to the surface. These correlated solution phase methods, coupled with mass spectral validation and modeling, provide unique insight into these thermoresponsive materials. Moreover, we detail a generalizable workflow for studying complex, solution-phase nanomaterials via correlative methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mass Spectral Library Quality Assurance by Inter-Library Comparison

A method to discover and correct errors in mass spectral libraries is described. Comparing across a set of highly curated reference libraries compounds that have the same chemical structure quickly identifies entries that are outliers. In cases where three or more entries for the same compound are compared, the outlier as determined by visual inspection was almost always found to contain the error. These errors were either in the spectrum itself or in the chemical descriptors that accompanied it. The method is demonstrated on finding errors in compounds of forensic interest in the NIST/EPA/NIH Mass Spectral Library. The target list of compounds checked was the Scientific Working Group for the Analysis of Seized Drugs (SWGDRUG) mass spectral library. Some examples of errors found are described. A checklist of errors that curators should look for when performing inter-library comparisons is provided. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On Digital Simulation of Multicorrelated Random Processes and Its Applications

Two methods are described to simulate, on a digital computer, a set of correlated, stationary, and Gaussian time series with zero mean from the given matrix of power spectral densities and cross spectral densities. The first method is based upon trigonometric series with random amplitudes and deterministic phase angles. The random amplitudes are generated by using a standard random number generator subroutine. An example is given which corresponds to three components of wind velocities at two different spatial locations for a total of six correlated time series. In the second method, the whole process is carried out using the Fast Fourier Transform approach. This method gives more accurate results and works about twenty times faster for a set of six correlated time series.

Sinha, A. K.↗

Using frequency-domain methods to identify XV-15 aeroelastic modes

The XV-15 Tilt-Rotor wing has six major aeroelastic modes that are close in frequency. To precisely excite individual modes during flight test, dual flaperon exciters with automatic frequency-sweep controls were installed. The resulting structural data were analyzed in the frequency domain (Fourier transformed) with cross spectral and transfer function methods. Modal frequencies and damping were determined by performing curve fits to transfer function magnitude and phase data and to cross spectral magnitude data. Results are given for the XV-15 with its original metal rotor blades. Frequency and damping values are also compared with earlier predictions.

Acree, C. W., Jr.↗

Using frequency-domain methods to identify XV-15 aeroelastic modes

The XV-15 Tilt-Rotor wing has six major aeroelastic modes that are close in frequency. To precisely excite individual modes during flight test, dual flaperon exciters with automatic frequency-sweep controls were installed. The resulting structural data were analyzed in the frequency domain (Fourier transformed) with cross spectral and transfer function methods. Modal frequencies and damping were determined by performing curve fits to transfer function magnitude and phase data and to cross spectral magnitude data. Results are given for the XV-15 with its original metal rotor blades. Frequency and damping values are also compared with earlier predictions.

Acree, C. W., Jr.↗

Improved motional Stark effect signal processing using fast Fourier transform spectral analysis

A Fast Fourier Transform (FFT) based method has been developed, which improves the frequency response of the Motional Stark Effect (MSE) system by about a factor of 10 over the conventional analog lock-in method. The method uses fits to rigorously derived analytic expressions for the FFT spectral components of the MSE signal to accurately obtain the amplitudes and phases of the 2f1 and 2f2 photo-elastic modulator (PEM) frequencies that encode the polarization angle. Since no frequency filtering is used in the FFT method, the frequency response is limited by fundamental measurement properties: the frequency response of the detector, photon statistics, sample rate, and the ability to resolve the spectral components. In contrast, the frequency response of the analog lock-in is limited by a low pass filter with a cutoff of around 500 Hz. In the case of the DIII-D MSE system, the output of the photo-multiplier tube detector was sampled at 500 kHz and FFTs with as few as 100 points were used to obtain the amplitudes of the 2f1 and 2f2 PEM frequency components. This corresponds to a frequency response of 5 kHz, about ten times faster than the analog lock-in amplifier system. Details of the FFT method will be presented and compared to those of the analog lock-in system.

Makowski, M. A.↗

Highly accurate spectral retardance characterization of a liquid crystal retarder including Fabry-Perot interference effects

Multiple-beam Fabry-Perot (FP) interferences occur in liquid crystal retarders (LCR) devoid of an antireflective coating. In this work, a highly accurate method to obtain the spectral retardance of such devices is presented. On the basis of a simple model of the LCR that includes FP effects and by using a voltage transfer function, we show how the FP features in the transmission spectrum can be used to accurately retrieve the ordinary and extraordinary spectral phase delays, and the voltage dependence of the latter. As a consequence, the modulation characteristics of the device are fully determined with high accuracy by means of a few off-state physical parameters which are wavelength-dependent, and a single voltage transfer function that is valid within the spectral range of characterization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

OPTICAL MICROVARIABILITY IN QUASARS: SPECTRAL VARIABILITY

We present a method that we developed to discern where the optical microvariability (OM) in quasars originates: in the accretion disk (related to thermal processes) or in the jet (related to non-thermal processes). Analyzing nearly simultaneous observations in three different optical bands of continuum emission, we are able to determine the origin of several isolated OM events. In particular, our method indicates that from nine events reported by RamIrez et al., three of them are consistent with a thermal origin, three with non-thermal, and three cannot be discerned. The implications for the emission models of OM are briefly discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser measurement of the spectral extinction coefficients of fluorescent, highly absorbing liquids

A conceptual method is developed to deduce rapidly the spectral extinction coefficient of fluorescent, highly absorbing liquids, such as crude or refined petroleum oils. The technique offers the advantage of only requiring one laser wavelength and a single experimental assembly and execution for any specific fluorescent liquid. The liquid is inserted into an extremely thin wedge-shaped cavity for stimulation by a laser from one side and flurescence measurement on the other side by a monochromator system. For each arbitrarily selected extinction wavelength, the wedge is driven slowly to increasing thicknesses until the fluorescence extinguishes. The fluorescence as a function of wedge thickness permits a determination of the extinction coefficient using an included theoretical model. When the monochromator is set to the laser emission wavelength, the extinction coefficient is determined using the usual on-wavelength signal extinction procedure.

Hoge, F. E.↗

Satellite estimation of spectral UVB irradiance using TOMS derived total ozone and UV reflectivity

A method for satellite remote sensing of spectral UVB radiation incident at the earth's surface for snow and/or ice free areas has been developed. Measurements of total ozone and UV reflectively from the Nimbus-7 Total Ozone Mapping Spectrometer (TOMS) instrument have been applied to this technique. Comparison of satellite estimates with ground based measurements of spectral UVB irradiance show differences which are comparable to differences between near simultaneous measurements made with two or more ground based co-located instruments.

Eck, T. F.↗

Multiscale spectral nanoscopy

A system and method for non-invasively tracking a particle in a sample is disclosed. The system includes a 2-photon or confocal laser scanning microscope (LSM) and a particle-holding device coupled to a stage with X-Y and Z position control. The system also includes a tracking module having a tracking excitation laser, X-Y and Z radiation-gathering components configured to detect deviations of the particle in an X-Y and Z directions. The system also includes a processor coupled to the X-Y and Z radiation gathering components, generate control signals configured to drive the stage X-Y and Z position controls to track the movement of the particle. The system may also include a synchronization module configured to generate LSM pixels stamped with stage position and a processing module configured to generate a 3D image showing the 3D trajectory of a particle using the LSM pixels stamped with stage position.

42 ENGINEERING↗

Serial segment method for measuring remnant

For tracking tasks where a sum of sine waves forcing function is used it is often difficult and/or expensive to obtain the pilot's remnant in the vicinity of the sine waves. For the case where each sine wave has at least four times an integer number of cycle per run length, this paper illustrates the serial segments method for measuring remnant power spectral density in a frequency band centered on each sine wave. This method can be implemented on digital, hybrid, or analog Fourier coefficient analyzers, and is particularly advantageous on the latter since properties of Fourier coefficients are exploited to yield both a remnant measure and an improved estimate of the correlated component.

Magdaleno, R. E.↗

On the determination of atmospheric minor gases by the method of vanishing partial derivatives with application to CO2

We present a general method for the determination of minor gases in the troposphere from high spectral resolution observations. In this method, we make use of a general property of the total differential of multi-variable functions to separate the contributions of each individual minor gas. We have applied this method to derive the mixing ratio of carbon dioxide in the mid-troposphere using data from the Atmospheric Infrared Sounder (AIRS) currently flying on the NASA Aqua Mission. We compare our results to the aircraft flask CO2 measurements obtained by H. Matsueda et al. over the western Pacific and demonstrate skill in tracking the measured 5 ppmv seasonal variation with an accuracy of 0.43 +/- 1.20 ppmv.

Atmospheric Infrared Sounder (AIRS)↗

Coupling detergent lysis/clean-up methodology with intact protein fractionation for enhanced proteome characterization

The expanding use of surfactants for proteome sample preparations has prompted the need to systematically optimize the application and removal of these MS-deleterious agents prior to proteome measurements. Here we compare four different detergent clean-up methods (Trichloroacetic acid (TCA) precipitation, Chloroform/Methanol/Water (CMW) extraction, commercial detergent removal spin column method (DRS) and filter-aided sample preparation(FASP)) with respect to varying amounts of protein biomass in the samples, and provide efficiency benchmarks with respect to protein, peptide, and spectral identifications for each method. Our results show that for protein limited samples, FASP outperforms the other three clean-up methods, while at high protein amount all the methods are comparable. This information was used in a dual strategy of comparing molecular weight based fractionated and unfractionated lysates from three increasingly complex samples (Escherichia coli, a five microbial isolate mixture, and a natural microbial community groundwater sample), which were all lysed with SDS and cleaned up using FASP. The two approaches complemented each other by enhancing the number of protein identifications by 8%-25% across the three samples and provided broad pathway coverage.

FASP↗

Enhancing the Resistance of Spectral Characteristics of Interference Coatings to Deviation in Parameters of Layers Entering into Their Composition

A new method of enhancing the resistance of spectral characteristics of interference coatings to deviations in parameters of layers entering into their composition is presented. The spectral characteristic that can be obtained using this method for the energy transmittance (or reflectance) of an experimentally manufactured coating is maximally close to the characteristic of the synthesized coating. A way to use several samples for monitoring the thickness of layers during the process of their formation with the aim to reduce the deviation of optical layers during manufacturing of interference coatings is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma effects on the spontaneous emission of synchrotron radiation from weakly relativistic electrons

A method for computing the spectral emissivity of spontaneous synchrotron radiation is discussed. The Klimontovich (1967) formalism in plasma kinetic theory is adopted in which an ensemble average of the microscopically emitted power is considered. The present method clarifies the meaning of the random phase approximation which is imposed in several existing theories of synchrotron radiation. Both the effects of dielectric polarization and two-particle correlations are included in the present discussion. The theory is applied to the case of a plasma in thermal equilibrium, for which it is shown that the effect of pair correlations on the emissivity vanishes. On the other hand, the effect of dielectric polarization is studied numerically for a wide range of parameters.

Freund, H. P.↗